Loading...
HomeMy WebLinkAboutE100.0TO LIGHT ABOVE FAN, VENT TO EXT. TO LIGHT ABOVE DED. DED. FAN/LIGHT, VENT \PTO EXT. FAN, VENT \PTO EXT. WP\PGFI \A1;1'-10{\H0.750000x;\S3#4;}"\A1;4'-6" \A1;4'-1" \A1;1'-0" \A1;2{\H0.750000x;\S1#4;}"\A1;5'-2" \A1;3'-6{\H0.750000x;\S1#4;}" 3S 220V GFI SGFI WP/GFI3S R S SSGFI GFI GFI S S S RS S S 3S R3S3S S S R RR R RR WP/GFI S 3S3S R 3S 3S 3S 3S 3S R R R TV TV PH S/C GDOGDO RR S3S 3S DWRGFISDISPS GFI GFI GFIGFIGFIGFIGFIPH GFI SGFISSS R S 3SR R \pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACLES INTENDED TO SERVE THE COUNTER TOP SURFACES OF A WET BAR THAT ARE LOCATED WITHIN 6'-0" OF THE OUTSIDE EDGE OF THE WET BAR SINK\P - LESS THAN 25'-0" FROM THE AIR CONDITIONING UNIT\P\P3. PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN, DINING AND PANTRY AREAS LIMITED TO ONLY THE REQUIRED WALL AND COUNTERTOP OUTLETS, AND THE REFRIGERATOR.\P\P4. REQUIRED LAUNDRY RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P\P5. REQUIRED BATHROOM RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL NOT INCLUDE ANY OTHER LIGHTS, FANS, OR ANY OTHER RECEPTACLES.\P \P6. ARC-FAULT CIRCUIT INTERRUPTION PROTECTIONS SHALL BE PROVIDED FOR ALL CIRCUITS SUPPLYING POWER TO BEDROOMS.\P\P7. ALL ELECTRICAL OUTLETS SHALL BE PLACED AT 15" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS NOTED IN THE FOLLOWING NOTES OR ON PLANS.\P\P8. ALL ELECTRICAL OUTLETS AT KITCHEN COUNTERS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\P9. ALL ELECTRICAL OUTLETS AT BATHROOMS SHALL BE PLACED AT 44" TO CENTER OF OUTLET ABOVE FINISHED FLOOR AT 36" HIGH COUNTERS, AND 40" ABOVE FINISHED FLOOR AT 32" HIGH COUNTERS, UNLESS OTHERWISE NOTED ON PLANS.\P\P10. ALL SWITCHES SHALL BE PLACED AT 38" TO CENTER OF SWITCH ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\P11. ALL WALL MOUNTED LIGHT FIXTURES SHALL BE SET AT A HEIGHT OF 66" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED ON PLANS.\P\ptz;\P12. SMOKE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER R314.4. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER R314.4. INSTALLATION SHALL MEET NFPA 72-70. SMOKE DETECTORS SHALL BE LOCATED ON EACH FLOOR LEVEL IN THE VICINITY OF ALL BEDROOM ENTRANCE DOORS AND WITHIN EACH BEDROOM.\P\pt1;\P13. CARBON MONOXIDE DETECTORS TO BE SUPPLIED BY THE HOUSE WIRING SYSTEM, HAVE BATTERY BACKUP AND EMIT A SIGNAL WHEN BATTERIES ARE LOW PER R314.4. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS PER R314.4. A CARBON MONOXIDE ALARM IS REQUIRED OUTSIDE EACH SLEEPING AREA AND/OR IN THE IMMODERATE VICINITY OF SLEEPING AREAS AS REQUIRED PER R315. DETECTORS SHALL COMPLY WITH UL2034-2008.\P\P14. LIGHTING IN CLOTHES CLOSETS SHALL BE FULLY ENCLOSED AND INSTALLED PER N.E.C. 410.16. FIXTURES MAY NE LOCATED ONLY WHERE THERE ARE THE FOLLOWING MINIMUM CLEARANCES TO THE NEAREST POINT OF STORAGE SPACE:\P\pa0.83333; - SURFACE MOUNTED INCANDESCENT FIXTURES: 12" MINIMUM\P - SURFACE MOUNTED FLUORESCENT FIXTURES AND RECESSED FIXTURES: 6" MINIMUM.\P\P15. NO PARTS OF HANGING FIXTURES, TRACK LIGHTING, AND CEILING PADDLE FANS SHALL BE INSTALLED WITHIN 3'-0" HORIZONTALLY OF A BATHTUB, MEASURED FROM THE OUTSIDE EDGE OF THE TUB AND 8'-0" VERTICALLY FROM THE TOP OF THE TUB RIM.\P\pa0.25,tz;\P16. RECEPTACLES SHALL NOT BE INSTALLED WITHIN A TUB OR A SHOWER ENCLOSURE.\P\pt1;\P17. GROUNDING: RECEPTACLE OUTLETS FOR RANGES AND CLOTHES DRYER MUST BE A 3-POLE WITH GROUND TYPE.\P\P18. INTERSYSTEM BONDING TERMINAL SHALL BE PROVIDED FOR GROUNDING COMMUNICATION SYSTEMS (CABLE TV & SATELLITE DISHES).\P\P19. GROUNDING AND BONDING OF METAL PIPING SYSTEMS SHALL MEET THE REQUIREMENTS OF THE N.E.C. SECTION 250.104. \P\P20. MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND PLACEMENT.\P\P21. VERIFY LOCATION OF ALL RECEPTACLES FOR APPLIANCES WITH MANUFACTURER SPECIFICATIONS.\P\P22. ALL CONVENIENCE OUTLETS WITH SWITCHES TO BE SWITCH AT TOP ONLY.\P\P23. ELECTRICAL CONTRACTOR SHALL VERIFY SPACE REQUIRED FOR METER INSTALLATION BEFORE CONSTRUCTION AND SHALL NOTIFY GENERAL CONTRACTOR OF ANY DISCREPANCIES.\P\P24. LIGHT FIXTURES ABOVE WHIRLPOOL, TUBS AND SHOWERS SHALL BE G.F.I. (SEC. 680.22.B.4, NEC)}UTILITY NOTES Electrical Schedule TableSymbolType Additional NotesS/CS PC R 220VDW GFIPHTVWP/GFISDISPS3S DETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT-CEILING-PULLCHAINLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - DISPOSALSWITCH - LIGHTSWITCH - THREE WAY UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL) 50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIOR CAT 5ERG-6FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0"Indiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Suzette Schuette3/30/2015 GARAGE RIGHT 3007-Turin TBD LOT 23 04/18/2019 PLOTTED: April 19, 2019 / Annie Lee / 3007-IN-MEPP.DWG First FloorElectrical Plan6.10 05/01/19 Mike Sheeks