Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E201a
m VOLTAGE DROP SCHEDULE DEMOLITION SYMBOLS: 120 VOLT BRANCH CIRCUITS U' TO 10 AMPS X = INDICATES EASTIN5 DEVICE TO REMAIN. TOTAL WIRE LENGTH (FEET) WIRE SIZE (Al XR INDICATES EXI51IN5 DEVICE TO BE REMOVED, �"I I 4� ;J� / K1 L , it M , jNl 1146=1% ALL CONDUIT AND Ml BALK TO 4 _ 100 #112 PANEL OR POINT OF COMMON USAbE. 101' 150' MIO j IS' 240' ae XRL = INDICATES EXI5n%DEVICE TO BE REMOVM 20 380' a6 AND RELOCATED, EMEND EXISTING WIRING OR REHIRE AS SHOVN ON DRAYIINK. 1 120 VOLT BRANCH CIRCUITS UP TO 14 AMPS XNL INDICATES WIN LOCATION OF RELOCATED TOTAL WIRE LENGTH (FEET) WIRE SIZE (Al IX15TN6 DEVICE. COINCIDES WITH'XRL'. j 11 -5' a12 XRW = INDICATES EXISTING DEVICE TO BE REWORKED. ib INS al0 REWORK AS 5FOAN OR REPLACE EXISTING II6' _ TES' a8 DEVICE Ill NEN AND REHIRE AS INDICATED. 166' 2R0' a6 )ORE) = INDICATES EXI5TIN6 DEVICE TO BE DISCONNECTED AND ALL CONDUIT AND WIRING TO _ MINIMUM BRANCH CIRCUIT WIRING D all AYI6. SCHEDULE ABOVE. BE REMOVED _ _ _ _—_—_—_—_—_—_ _—_—_—_—_—_—_—_—_ _— _—_—_—_—_—_—_—_� SHALL INCREASE WIRE SIZE BASED ON SLFEDULE ABOVE. CTX = INDI6ATE5 CONNECT TO EXISTING OIRCUIT(S) V J. J. JIII STOCK ROOM B' Fi 5 1 i❑ ILtJ I I11 T---T---T___T___T___ iLUI I_ I u II 1 t � Ir { { v�vvv#vvv#vvv Y, I I II I -' -I-rl DEPARTMENT �� FyFy Fti IL J 7C l ❑ L I WINE AND BEER li I I i lilt 113 li li Ir+y j--�- IL yT---yT---yT---yT_yT___11jT IL,J ---T -T -T -T -T -Tf" Ilfr� 4_-1___ L I I T-,-L' WINE AND BEER I SERVICE oil - J j 114 ---' -11 R1 I Q;:--A r-, 1L_J OFFICE 131 23 H I, ik�IwlLl CUSTOMER SERVICE I_I �x1M�L.�jT.' 21 !31,Ell I- :I^I l IITI' l In T` r FRO OFFICE Y Y , 1 , L L J L I 1. J 1 VESTIBULE 126 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camlel R1 SALES ------- AREA 116 L_______, � I� I j I I j I I j l l j I I I I I I I I I I I I I I j I I j I I j I I I I I I I I I I I I I I I I j I I j I I j I I I I I I I I I I I j I I I I I I I I I I I I I I I I I I I I I I jI j I I I I j I I j I I J I I I I I I I I I I I I I I I I ' I I I ' I I I I I j ' I ' I I I I I L___. 1771 L___. 7(1 I' ❑ I CHECKOUT „7 u Y v RECEIVING AREA Ell 11 ,I ,I ,I II' lir 111 I I u,' y --- -- --I--------------------- STAIR N0.51HIPPA 110 I STORAGE CAGE li __li y___II it ME 6 it Ii' '___ _ nr- _ _ _ _ _ _—_—_---, 8, �J'I II II y II 1 II, II II II II EST OM L__aLL�LaLj II STOCK I---' I ROOM'. a PRINTER } YT' Ifr Tel 1 iO - CORRIDOR JIIT X, GROCERY 105 f II IL�I I� FREEZER i I �I I: nn�gg 1}�I I.:� 75cG LIQUOR ®� STORAGE �j III � III III III III III III 111 - min �IElm min wl DAIRY COOLER .s; RMACY II L1J',_, ITING u 04A �_ CURBSIDE STORAGE o 551 R3/ - - I GENERAL NOTES: AI ALL CIRCUIT5 51 ON DRAWUO ARE FOR REFERENCE ONLY. EL. S TO FIELD VERIFY NUMBER OF 5PARE CIRCUIT BREAKERS AND SPACES IN EXI51P% PANELS AND RE5E FOR TEN CIRCUITS 5EIVAIN ON DRAWING. EL. 15 TO VERIFY LOADS ON PANELS AFTER DEMO OF EXISTING CIRCUITS AND ADDING NEXT CIRCUITS TO PANELS DO NOT EXCEED THE RATING OF THE PANEL AND SERVILE FEEDER PROVIDE NEW CIRCUIT BREAKERS OR REUSE EXISTING IN PANI MATCH PANEL TYPES AND UL RATIN65. B) ALL OUTLETS, ARE TO BE PROVIDED WTH PANEL AND CIRCUIT NUMBER VF516NATION ON COVERPLATE. C) EL. SHALL PROVIDE TfPB'RITTEN DIRECTORIES FOR ALL MODIFIED PANELS INDICATING NEW HORK COMPLETED. D) EL. SHALL FIELD VERIFY ALL EXISTING CIRCUITS 940M TO BE REU.,ED HAVE AMPLE LOAD CAPACITY FOR WORK INDICATED. EL. SHALL VERIFY THAT EXI5TI16 CONDITION5 ARE A5 SHOWN ON DRAYUN65. IF A DISCREPANCY EXISTS THAT HILL AFFECT THE Ill IT SHALL IMKPIATELY BE BROU6W TO THE ATTENTION OF THE OK ER AND ENGINEER E) ALL PANELS ARE EXI5TIN6 UNLESS NOTED OTIERIll F) CONTRACTOR MAY OPTION TO RUSE )l MEN EEA5IBLE WHERE EOJIPMENT 15 BEING REMfNID AND REPLACED IN THE SAME LOCATION. IF MIRING 15 IN ACCEPTABLE CONDITION IT MAY BE USED TO REFEED NEW OR RELOCATED EGUIPMEW 6) ALL CONIIT5 ARE TO BE PAINTED TO MATCH 9URROUIDINE, FINISHES (SEE ARCHITECTURAL PLANS). U ALL WIRING IN LOW WALLS TO BE IN RACEWAY. U HNERE RECEPTACLES AND DATA OUTLETS ARE INSTALLED ON MILLWORK SUCH A5 COUNTERS. CABINETS ETC., CONCEAL ALL CONDUITS, MO CABLE, 6 DATA CABLRI6 IN TOE SPACE OF MILLWORK OR HIDDEN CHASE BBNND MILLWORK TO MINIMIZE EXPOSURE OF CONDUIT AND LABLINK. -0 ALL 15A Al 20A RECEPTACLES LOCATED IN PREP AREAS ARE TO BE GFC PROTECTED, WITH THE EXCEPTION OF THOSE THAT ARE DE516HATW A5 1.6. TH05E RECEPTACLES 5HALL BE PROTECTED BY 6FL1 CIRCUIT BREAKERS. K) ALL CONDUITS ARE TO BE RUN AS H16H AS POSSIBLE TFROUSEOUT SALES AREA AND ANY AREAS THAT ARE OPEN TO PUBLIC VHEW ALL CONDUITS, MNOH ARE TO BE SUPPORTED FROM THE STRUCTURE ABOVE, SHALL BE SUPPORTED FROM TOP CORD OF STRUCTURAL JOIST ONLY. NO CONDUITS SHALL OF 9UFPORTED FROM BOTTOM CORD OF JOISTS OR ROOF DECK. ADDITIONALLY, NO CONDUITS SHALL BE MOUNTED ABOVE THE BOTTOM OF THE TOP CORD OF THE JOIST. IN NO CASE SHALL CONVUIT5 BE ROUTED BETVEEN ROOF DECK AND TOP CORD Ol YJIST. NO FLEX CONDUIT OR MC CAELE TO BE UJ® THROWHOIR SALES AREA AND ANi AREAS ARE OPEN TO RELIC VIEW ULEf NOTED OTERWISE ON PLANE.. U ALL CUTLETS IN TILE WALLS IN FREE AREAS K5T BE INSTALLED PER NOTES ON DRFNNNG EOOI. M) SEE DRAYUN6 E001 FOR ECUIPFEFT SCHEDULE. AREAS THAT ARE OPEN TO RELIC VIEW ULLE55 NOTED I BRANCH CIRCUITING OTIERWSE ON PLANS. GENERAL NOTES: A) ON 20 AMP, I POLE CIRCUITS, HOMERUG 5NALL BE 2 a10 AY15 H END IN 3/4' CONDUIT MINIMUM. INCREASE WIRE 511E PER VOLTAGE DROP TABLE. B) ON 20 AMP, I POLE ISOLATED 6RLURD CIRCUITS, HOMERW5 5HALL BE 2 010 All ♦ 6ND ♦ 150L. &ND IN 3/4- CONDUIT MINIMUM. INCREASE WIRE SIZE PER VOLTAGE DROP TABLE. C) ALL CIRCUITS SHALL HAVE INDMDJAL NEUTRAL CONDUCTORS C49NTIH06 FROM PANEL. SHARED NEUIRAL5 ARE NOT PERMIT W CODED NOTES: Oj ALL EXISTING DEVICES, EMIRMEW,, AND FIRE ALARM DEVICES IN THI5 AREA ARE FA511W TO REMAIN, U.NO. MAINTAIN EXISTING CIRCUITS. IF CIRCUITS ARE ENCOUNTERED Ill MUST REMAIN BUT HAVE NOT BEEN ADDFT55W BY THIS DB16K EL. MUST IMMEDIATELY BRING TO THE ATIEMION OF THE E1 INEER_ O2 EL. TO FIELD COORDINATE WITH R.C. FOR FIELD MODIFICATIONS ON COMMUNICATION N,EIYORK TO REMOTE BICLOBIRE AND ALL EMS WIRING FOR REMOTE ENCLOSURE. O 2 a12 a all &ND. - 3/4'6 FOR EVAPORATOR PU R05T CIRCUIT 5HOYN TO BREAKER / CONTACTOR IN REMOTE ENCLOSURE 111. ® 3 all • a12 END. - 3/4'C FOR EVAPORATOR FAN CIRCUIT SHOHN TROUGH CONTACTOR / RELAY IN REMOTE BLLOFHRE 01. l EL. TO INSTALL ONE CONTINUOUS L0 6TH OF NEAT TAPE (12OV) FASTED TO DRAIN LINE AND INSULATE WITH 1/2' ARMAFLEX (NEAT TAPE AND ARMAFLEX SUPPLIED BY REFRI6BRATION CONTRACTOR) WRAP 2 FEET OF FEAT TAPE AROUND EACH FOOT OF PIPE. © EL. TO COORDINATE LOCATION OF ALL EQUIPMENT IN FREEZAULOOLER PRESSURE 5WITCN, SOLENOID, PRESSURE RELIEF, NEAT TRALE DOOR HEATER ETLJ HITH REFRI6ERATION CONTRACTOR AND WIRE A5 REWIRED. O7 ELECTRICAL CONTRACTOR TO PROVIDE WEATHER PROOF DISCONNECT AT ALL COOLERAREEZER EVAPORATOR COILS. DISCONNECT FOR 120V EQUIPMENT TO BE MOTOR RATED T06GLE 5WITCH NO THERMAL OVERLOAD REQUIRED). OS FREEZER DOOR ALARM. REFER TO REFRIGERATION DRAWINGS FOR WIRING DETAIL AND ADDITIONAL. INFORMATION FREEZER EVAP AND LIGHTING SHALL 13E CONTROLLED HITH DOOR ALARM MOUNTED ON FREEZER EXTERIOR PROVIDE ALL Hil PER WIRING DIAGRAMS. O9 PROVIDE LOW VOLTAGE HIRING FOR DOOR ALARM SIGNAL AND FREEZER SENSOR WIWN6 TO REMOTE ENCLOSURE ABOVE CVR85IDE COOLER AS DIRECTED BY REFRIGERATION CONTRACTOR. 10 M54 REMOTE ENCLOSURE LOCATED ABOVE GUREINDE COOLER HITH BREAKERS / CONTALTORS PROVIDED BY RL. FOR FREEZER EVAPORATOR Al DEFF 05T 3 a12 ♦ a12 SHP. - 3/416 TO PANEL IS, CIRCUIT II (20/2). 11 SINGLE CHAMFER POVER POLE UP FOR POVER TO 6ONDOL.AS (TYPICAL). 12 EL. To PROVIDE POINER CONNECTIONS To LED U 5hTIN6 THAT 15 PRE-116TALLED WITH SHELVING / 6ONDOLA PROVIDE ALL HARDWARE AND LABOR RECURRED 13 N3H LOCATION FOR RELOCATED EUIPMFIT. EL. TO VERIFY EX15TIN6 POVER REOIIREMFTS IN FIELD AND EXTEND EX15T1% CONDUIT AND FEEDER TO EMIPMENT NEN LOCATION, OR PROVIDE NEW FEEDER, AND PROVIDE WIN DEVICE. 14 EL. GULL RELOCATE EXISTING TEMPERATURE SENSOR TO NEH LOCATION SNIONNI AS 'XNL' AND EXTEND HIRING. 15 MEN LOCATION FOR NE111 ELECTRICAL PANEL. EXTEND ALL A550LIATED Clia TS REQUIRED TO REMAIN ACTIVE INCLUSIVE OF ALL I l6, CONDUIT, BOl ETC. FEEDERS K5T BE EMENDED TO N3H PANEL N5', A5 51O1 ON DRAWING. ALL PAL BOXES REQUIRED TO ACCOMMODATE THIS REROUTING METHOD 5FIALL BE LOCATED IN ACCESSIBLE LOCATIONS ABOVE THE PARTITION WALL HEIGHT. 16 AREA FOR NEY LOCATIONS OF RROCATD OR NEW EONDOLAS / 51ELVINO. EL. TO MAINTAIN EXI5n% CIRCUITS FOR LI6W5 AND DEVICES ON 6ODOLA5. I I In I I IIII I I I - - - - - - - �-��_.3, O� gy�"O�y`+bL19s,,Ie,�A;.NN°w;.•9Pm�.?„•S°�p!„N.T•,1�.A80x".1Ln'.Ap NO6R°P6FF.7.A0,OCb3m'Ve't `oR• y°'SPa s DATE RE0V. . S0 REVISIONS TDAV.TNFNEW POWER FLOOR PLAN 0.P117FlhwAs S. TE PROJECT GRANT EAGLE MARKET DISTRICT # 655B0Y 04-03-19 uum ISSUED FOR CONSTRUCTION - LOCATION THE BRIDGES DEVELOPMENT • 11505 ILLINOIS STREET ISSUED FOR BID 04-03-19 CARMEL, IN 46032 ISSUED FOR REDLINE REVIEW _ OWNER GIANT EAGLE, INC. McNally 6NOttlg InowpM NATE MCGwaEG*rvo. NEW POWER FLOOR PLAN ISSUED FOR PERMIT 04-03-19 04-03-19 ,19112 SCALE: 3/3211.I.-�. Mc &A ARP ISSUED FOR 50 °k - G`"` "ro 1 \ ��� Consulting,iR Engineers out, laeo AS NOTED CDLL CLEARANCES VFAIFY KICK OFF MEETING zwmemeryaeghl zm M,..x �, ALLCLEARANCES IN AND WarrPhonenN16.H6g4696-4e118 E 001A DIMENSIONS IN FIELD FINAL APPROVED PLAN - Emil ililil heeoe-fa.l vazosseTn CLG fnall: mall@,rchenryaso,0inmm N • 13 'XNL' 6' SC. ` �I SBGi RTIFB VEST A191��� RE alfP' /Noll I (20/]) 6°3 v/ilG°,C'j matl — — URI l: UJ)UJ/ 1.7