HomeMy WebLinkAboutR101AG\:% OF Cqq� J_l long �� /ND A P 1111111101101 arm -no PIT SCHEDULE NO. QTY- L x W x D (inches) MODEL CO/NR TYPE LINER V/N 01 24x24x18 ADL 1 V - V 02 -- 24x24x24 ADL Y - Y RELEASED FOR CONSTRUCTION ; Y Subject to compliance with all regulations Y - Y of State and Local Codes - Y City of Car nel - V SED FOR NEW CASE LAYOUT E NEW DIAMOND PLATE LID note. 05/03/1 Q (ISTING PIT LID AND BACKFILL On - BEER GOOIER 7U0 x]•-4• (IX,NC) o,. C19G B B19G (IX NQ EEVN n (EXNC) ED O B38-KITCHEN COOLER I6'd' x 36-6" NEEMOD) C53-KITCHEN )E PREP (202_ E2' MOP (E17 IK IN (NEW) 59 CEO CASES C53 CASE CONTROLLER CONTROLLER 22'-6'x Il0' ®(EX,NC) CIX LbIW of (rx,Nn 03 - DELl COOLER CK f31-PREP 13-0'SHIED EC MODS COOLER ODENE) 13'E^ x v'-0^ `,5 (EX,NO Nq IX.Nn [33 RAW MEAT COOLER 11'-6"x 10'SEE 'EEx (Ex,rvcl BIB - PREP OCR FREEZER 4'm 2 3-6'•x 12'.6 o X CIE RESTAURANT BUST COOLER CHILLER T (EUC) 0 13 e I �C1Bf� 0 BT-sFAFooO Y fRE¢ER '� e EX NO) B36-SEAFODD GOOIER aX (E NC) ICE e RED - PERT EE IDS COOLER R y^ 39'-0^x20.-0^ R y^ C49 SEAFOOD PREP (430 SF) (EYNq 0SF) (E IX x B35-8' I B34. &'HER SVC DEEPER 1 �i SEAFOODYYY SEAFOOD NEXOQ (EANC) y " 2 Ea ax (] w 0 �� O Z C C29-AMTEMN CGS SERVICE MEAT PREP (345 SF) (EXHC) EASE T� EnX eEvx C \MEAT PREP P u (6209F)(ECNC) m e Ul-MEAT PREP (690 sF)(Ex,xQ cCx OO 0 ICE MEAT(IX,NC)- CIX O "26- 24' OHM FRESH MEAT (EX,N(O— I'owlz+(2)ow¢ {�B4 8'awlz+(z)ow¢ TEMP MEAT(EX,NC) I DWL TEMP MEAT(IX,NC]_ ca Q O ax DOPE j C11-24'+(2) ENDS �( �PROOUCE[ROPED (EX,NQ� B ` �: ELI 1 < < z ca cw nd � o� r �9 4040 I LJI ww100 O (rvEw) ® CA3. PRODUCE COOLER wx-vo 16'-6•x 36'-6" NEW) (NEW) NOTES,® H CS2-PRODUCE P ) WK-IW O NO: 835. 24' OHM FRESH O H cIX CIO 16'+(2) ENDS rFRODUCE ISONND O)SNQ­1 ® rCOX ax c o 5 LN H FRESH MEAT 0 o I z z El x x 0 0 I I H- o o H I Q7-8 DOOR INE CASE(EX,NQ� H Z Z 7 OF x I <s C O ERurr Lozzs COOPER IRREGUEXCNC) SO OF £ £ IMA �Tli *°�� ET DIS'�TRIC�T s REFRIGERATION LEGEND: Z� ISOLATION BALL VALVE Rw ELECTRONIC EVAPORATOR PRESSURE REGULATOR (EEPR) EVAPORATOR PRESSURE REGULATOR (ERR) SOLENOID VALVE H CHECK VALVE 3-WAY VALVE THERMAL EXPANSION VALVE ANGLE PURGE VALVE # NEW REFRIGERATION PIT BOX REFERENCE SCHEDULE FOR PIT #, MODEL. EXISTING REFRIGERATION PIT BOX sl REFRIGERATION CASE TEMPERATURE SENSOR FURNISHED AND INSTALLED BY OEM. WIRED PULLED BY EC. TERMINATIONS BY RC_ REFRIGERATIONCOOLERIFREEZER(BOX PROBE) 53 TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC. TERMINATIONS BY RC. REFRIGERATION COOLEWFREEZER (BULLET TYPE) s9 TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC. TERMINATION BY RC. REFRIGERATION CASE TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRED PULLED BY EC. TERMINATIONS BY RC. s% EXISTING TEMPERATURE SENSOR TO REMAIN OEM INSTALLED & WIRED CASE TEMPERATURE SENSOR, Fl I/O BOARDS AND SOLENOID VALVES PER CASE. F2 OEM INSTALLED & WIRED CASE TEMPERATURE SENSOR, INPUT BOARD, ESR BOARD AND CDS VALVE. REFRIGERATION CASE DEFROST TERMINATION SENSOR FURNISHED On AND INSTALLED BY OEM. WIRE PULLED BY EC. TERMINATIONS BY RC. OREFRIGERATION CASE (COOLER/FREEZER) DEFROST TERMINATION DT2 SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC_ TERMINATIONSBY RC- 5C SELF CONTAINED REFRIGERATION DISPLAY CASES ® EXISTING DANFOSS AKCC5S0 CASE CONTROLLER WITH EEV. CC1 DANFOSS AKCC550 CASE CONTROLLER. OEM INSTALLED. DANFOSS AKCC550 CASE CONTROLLER ENCLOSURE. RC TO FURNISH CC2 AND INSTALL ON OUTSIDE OF COOLER/FREEZER IN A SERVICABLE LOCATION. COORDINATE WITH EC FOR RS-485 COMMUNICATION NETWORK WIRING MODIFICATIONS. FIELD VERIFY. EEV( EXISTING ELECTRONIC EXPANSION VALVE. EEv FIELD WIRED ELECTRONIC EXPANSION VALVE. RE EMS REMOTE ENCLOSURE. REFERENCE R-501 FOR I/O POINTS. PARASENSE LEAK DETECTION CHANNEL I.D. Lox REFERENCE R-201 FOR CHANNEL I.D. #. SUCTION / RETURN LINE LIQUID / SUPPLY LINE - — — - NEW 8" PVC UNDERGROUND REFRIGERATION LINE CONDUIT. ---- EXISTING 8" PVC UNDERGROUND REFRIGERATION LINE CONDUIT. ---- EXISTING UNDERGROUND TRENCH AD RISER GENERAL NOTES A. REFRIGERATION INSTALLATION SHALL BE PERFORMED IN CONFORMANCE OF GIANT EAGLE SPECIFICATIONS SECTION 240000, 2010 ASHRAE HANDBOOK, and OEM INSTALLATION MANUALS. B. REFRIGERATION CONTRACTOR TO COORDINATE PIPE ROUTING REFRIGERATION EQUIPMENT PLACEMENT WITH WORK OF OTHER TRADES. C. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL NEW REFRIGERATION PIPING AND HANGERS IN ACCORDANCE TO GIANT EAGLE PIPING PRACTICES. D. REFRIGERATION RISERS TO BE MADE AT DESIGNATED LOCATIONS AND COORDINATED WITH GIANT EAGLE INC. FOR RISER INDICATED NEAR A COLUMN LINE, RISE AS CLOSE AS POSSIBLE TO THAT COLUMN LINE. FOR RISERS AT A COLUMN SEE R301, DETAIL 12 E. OVERHEAD REFRIGERATION LINES MUST NOT RUN UNDER SKYLIGHTS. COORDINATE OVERHEAD RUNS WITH SKYLIGHTS F. INSTALL PIPE HIGH POINTS AS CLOSE AS POSSIBLE TO BOTTOM OF JOISTS G- REFRIGERATION CONTRACTOR IS TO COORDINATE PLACEMENT OF REFRIGERATION PITS & COVERS. PIT LOCATIONS ON THIS PLAN ARE STRICTLY DIAGRAMMATICAL GENERAL CONTRACTOR TO FURNISH & INSTALL. REFRIGERATION CONTRACTOR TO SEAL PIT COVERS IN PREP AREA AT COMPLETION OF INSTALLATION. H. REFRIGERATION CONTRACTOR IS RESPONSIBLE TO RECEIVE, SET, AND INSTALL GIANT EAGLE PROVIDED REFRIGERATED DISPLAY CASES INCLUDING SELF CONTAINED UNITS AND WALK-IN COOLERIFREEZER PANELS AS PER T-1. I. REFRIGERATION CONTRACTOR TO PROVIDE, COORDINATE, SET, AND LEVEL EQUIPMENT SUPPORT RAILS AND PIPE PORTALS FOR ROOF TOP REFRIGERATION EQUIPMENT AS PER STRUCTURAL DRAWINGS. GC AND ROOFING CONTRACTOR RESPONSIBLE FOR FINAL INSFALLATION. J. SEE R401/R402/RSOl/R502 FOR ADDITIONAL INFORMATION ON BMS AND SENSORS. REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR PROGRAMMING OF BRIE K. REFRIGERATION CONTRACTOR TO REMOVE ALL ABANDONED, UNUSED REFRIGERATION PIPING, HANGERS, SUPPORTS, COMPRESSOR RACK, AND CONDENSERS. L COORDINATE DISPOSITION OF REMOVED EQUIPMENT WITH GIANT EAGLE- M. GC TO PROVIDE OPENING FOR ALL REFRIGERATION LINES TO COMPRESSOR ROOM, CONDENSORS AND CASES. KEY NOTES O REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL SUCTION LINE ISOLATION BALL VALVE AND LIQUID LINE ISOLATION BALL VALVE IN THE BRANCH LINES OF EACH CIRCUIT OVERHEAD. REFERENCE LOOP SCHEMATICS ON R-201. O REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL EEPR, SUCTION LINE ISOLATION BALL VALVE AND LIQUID LINE ISOLATION BALL VALVE IN THE BRANCH LINES OF EACH CIRCUIT ON TOP OF CASE, UNDER CASE OR ON TOP OF COOLER/FREEZER. 03 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL EEPR/EPR VALVE AT RACK OR FOR FOR PROPOSED REFRIGERATION SYSTEM. 0 REFRIGERATION LINES TO RUN UNDERGROUND AND TRAP IN PIT AT RISER LOCATION. REFRIGERATION RISERS RUN IN THE WALL/OR EXPOSED. COORDINATE WITH PLUMBING AND ELECTRICAL TRADES FOR LOCATION. REFERENCE DETAIL #11/R-302. © REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD ON TOP OF CASE(S), TRAP AT RISER LOCATION , RISE EXPOSED AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. REFERENCE DETAIL #12/R-301. © REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD ON TOP OF CASE(S), TRAP AT RISER LOCATION , RISE IN WALL AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. REFERENCE DETAIL #12/R-301. Q REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD UNDER CASE(S), TRAP AT RISER LOCATION , RISE EXPOSED AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. O INDIVIDUAL SUCTION LINES RUN TO RACK, LIQUID LINES RUN TO RECEIVER OR LIQUID LOOP. O INSTALL DOUBLE SUCTION RISER, 10 TOP FEED ELECTRICAL. TOP FEED REFRIGERATION. 01 BOTTOM FEED ELECTRICAL. BOTTOM FEED REFRIGERATION. 12 REFRIGERATION RISERS RUN IN WALL/BULKHEAD. 13 RC TO PROVIDE INTERMEDIATE TRAP FOR SUCTION RISERS EXCEEDING 15'. 14INSTALL NEW EVAPORATOR COILS PROVIDED BY REFRIGERATION CONTRACTOR. REFERENCE DETAILS #8, #9 & #10/R-301. 15 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL LIQUID LINE ISOLATION BALL VALVE IN BRANCH LINES OF EACH CIRCUIT OVERHEAD. 16 REFRIGERATION PIPING ENCLOSURE. GC TO PROVIDE AND INSTALL. REFERENCE MECHANICAL DRAWINGS FOR ENCLOSURE DETAILS. ll I/O BOARDS AND SOLENOID VALVES ARE FACTORY INSTALLED PER CASE. IB RC TO PROVIDE AND INSTALL NEW TXV VALVE. ®I/O BOARDS, TEMP SENSOR, SOLENOID VALVES AND EEPR VALVE ARE FACTORY INSTALLED PER ISLAND. O ^• '�' 's VAIt REV. LOG REVISIONS 44 •.�p18Tf,t'-l�•.� N0. N0. P Fo I S CI f No. : o? 11500371 °COG-mLE REFRIGERATION PLAN F8• IA•; Gx F PROJECT ONAL GIANT EAGLE #6550 •,,,, EN,,+`• Bw W,w LOCATION THE BRIDGES ISSUED FOR CONSTRUCTION 116 STREET & SPRING MILL ROAD ISSUED FOR BID 04/19/19 OWNER CARMEL, IN ISSUED FOR PERMIT 04/19/19 DATE ISSUED FOR REDLINE 04/03/19 MAR ISSUED FOR 60 %DRAWF/\Z 10 BMH 1'-0" KICK OFF MEETING -- 300 S. MAIN STREET, PITTSBURGH, PA 15215 (412) 782-6338 DESIGNED FINAL APPROVED PLAN FAZIOMECHANICAL.COM BMH UTM