Loading...
HomeMy WebLinkAboutR101Bz cAs ca CONT OTER fl <CE CCE CCl ­-6RELH BEVY{ ER EX,NC R1 GROCERY ( ) FREEZER FREEZER (3 O O O 33^E x 16-D^ # � IX,uC) C w"aea 0 n n I L u u 0 0 < a ® ® o ® o M- PRODUCE f� E COOLER - I6'6"x36'fi" ll-15 WORS AL FROZEN f00n (IX,NC 1fi13000R5 RL wrc 21R (NEMC (NEW) NOTES. H H 0 0 H HH C52 PRODUCE O A142DRS PREP(207 SF) (NEW) RLI/c AIR -3DRS Aa. ROSS NOTES.� wxaea tNC RI1/c (Ex,Ng r �( Rcl/E (Ex,Ng r (NER)I I NE CASE (E%NC)7 ® ® �® 8E5- 24' DIM FRESH MEAT(Ex,NC)1l4 24' OHM FRESH MEAT RX,NCJ_ ti cIXt3 ® t5 O i H H H 0 0AS - ERAS p R B23-16'BMD SERVICE I �{ RLFR02N WERY(EX,NC) JRANERY(IX,NgI ] O O ®ISOI cIX s w o F- G RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carelel DATE: 05/03/19 II H 2If 'III 'III 'III -GR'III 1♦ �� Siva S¢.n i i l L C III III III III III III �LuW As-3DRs (EX,NC) RLGC(IX,NC) CIX 0 7-7 ��T A2 -30RS RLGC(EXMC) 0 +2 J< ®O Ale - CURBVDE FREEZER 1216" x 9'-0" (NEW) NOTES® A3e-CURBSmE ax EEV% (EYNP Aal-(1/2)WRY COOLER 11W x 6E'tl' (IX,NC) 8 (Ex,NQ ARM -(V2) DNRY CODER 11W x 69'-0" (ESNC) EEV% lExrvCl G H so O PIT SCHEDULE N0. QTY. L x W x D (inches) MODEL COVER Y/N TYPE FIB. GLASS LINER Y/N l� -- 24x24x18 ADL Y - Y Q2 24x24x24 ADL Y - Y Q3 -- 24x36x24 ADL Y ® -- 24x24x18 APO Y QS 24x24x24 APOY 4YY 24x36x24 APO Y 36x36X24 ADL Y ® -- EXISTING, REUSE PH TO BE REUSED FOR NEW CASE LAYOUT 0 - EXISTING,ABANDON GC TO PROVIDE NEW DIAMOND PLATE LID ® - EXISTING, REMOVE GC TO REMOVE EXISTING PIT LID AND BACKFILL REFRIGERATION LEGEND: Z� ISOLATION BALL VALVE Rw ELECTRONIC EVAPORATOR PRESSURE REGULATOR (EEPR) EVAPORATOR PRESSURE REGULATOR (ERR) SOLENOID VALVE H CHECK VALVE 3-WAY VALVE THERMAL EXPANSION VALVE ANGLE PURGE VALVE # NEW REFRIGERATION PIT BOX REFERENCE SCHEDULE FOR PIT #, MODEL. EXISTING REFRIGERATION PIT BOX s1 REFRIGERATION CASE TEMPERATURE SENSOR FURNISHED AND INSTALLED BY OEM. WIRED PULLED BY EC. TERMINATIONS BY RC. REFRIGERATION COOLERIFREEZER(BOX PROBE) 53 TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC. TERMINATIONS BY RC. REFRIGERATION COOLEWFREEZER (BULLET TYPE) se TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC. TERMINATION BY RC. REFRIGERATION CASE TEMPERATURE SENSOR FURNISHED AND INSTALLED BY RC. WIRED PULLED BY EC. TERMINATIONS BY RC. s% EXISTING TEMPERATURE SENSOR TO REMAIN OEM INSTALLED & WIRED CASE TEMPERATURE SENSOR, Fl I/O BOARDS AND SOLENOID VALVES PER CASE. F2 OEM INSTALLED & WIRED CASE TEMPERATURE SENSOR, INPUT BOARD, ESR BOARD AND CDS VALVE. REFRIGERATION CASE DEFROST TERMINATION SENSOR FURNISHED On AND INSTALLED BY OEM. WIRE PULLED BV EC TERMINATIONS BY RC. OREFRIGERATION CASE (COOLER/FREEZER) DEFROST TERMINATION °T2 SENSOR FURNISHED AND INSTALLED BY RC. WIRE PULLED BY EC. TERMINATIONS BY RC. 5C SELF CONTAINED REFRIGERATION DISPLAY CASES ® EXISTING DANFOSS AKCC5S0 CASE CONTROLLER WITH EEV. CCI DANFOSS AKCC550 CASE CONTROLLER. OEM INSTALLED. DANFOSS AKCC550 CASE CONTROLLER ENCLOSURE. RC TO FURNISH CC2 AND INSTALL ON OUTSIDE OF COOLER/FREEZER IN A SERVICABLE LOCATION. COORDINATE WITH EC FOR RS-485 COMMUNICATION NETWORK WIRING MODIFICATIONS. FIELD VERIFY. EEVx EXISTING ELECTRONIC EXPANSION VALVE. EER FIELD WIRED ELECTRONIC EXPANSION VALVE. RE EMS REMOTE ENCLOSURE. REFERENCE R-501 FOR I/O POINTS. PARASENSE LEAK DETECTION CHANNEL I.D. L0A REFERENCE R-201 FOR CHANNEL I.D. #. SUCTION / RETURN LINE LIQUID / SUPPLY LINE - — — - NEW 8" PVC UNDERGROUND REFRIGERATION LINE CONDUIT. ---- EXISTING 8" PVC UNDERGROUND REFRIGERATION LINE CONDUIT. ---- EXISTING UNDERGROUND TRENCH RISER GENERAL NOTES A. REFRIGERATION INSTALLATION SHALL BE PERFORMED IN CONFORMANCE OF GIANT EAGLE SPECIFICATIONS SECTION 240000, 2010 ASHRAE HANDBOOK, and OEM INSTALLATION MANUALS. B. REFRIGERATION CONTRACTOR TO COORDINATE PIPE ROUTING REFRIGERATION EQUIPMENT PLACEMENT WITH WORK OF OTHER TRADES. C. REFRIGERATION CONTRACTOR TO PROVIDE AND INSTALL NEW REFRIGERATION PIPING AND HANGERS IN ACCORDANCE TO GIANT EAGLE PIPING PRACTICES. D. REFRIGERATION RISERS TO BE MADE AT DESIGNATED LOCATIONS AND COORDINATED WITH GIANT EAGLE INC. FOR RISER INDICATED NEAR A COLUMN LINE, RISE AS CLOSE AS POSSIBLE TO THAT COLUMN LINE. FOR RISERS AT A COLUMN SEE R301, DETAIL 12 E. OVERHEAD REFRIGERATION LINES MUST NOT RUN UNDER SKYLIGHTS. COORDINATE OVERHEAD RUNS WITH SKYLIGHTS F. INSTALL PIPE HIGH POINTS AS CLOSE AS POSSIBLE TO BOTTOM OF JOISTS G. REFRIGERATION CONTRACTOR IS TO COORDINATE PLACEMENT OF REFRIGERATION POTS & COVERS. PIT LOCATIONS ON THIS PLAN ARE STRICTLY DIAGRAMMATICAL GENERAL CONTRACTOR TO FURNISH & INSTALL. REFRIGERATION CONTRACTOR TO SEAL PIT COVERS IN PREP AREA AT COMPLETION OF INSTALLATION. H. REFRIGERATION CONTRACTOR IS RESPONSIBLE TO RECEIVE, SET, AND INSTALL GIANT EAGLE PROVIDED REFRIGERATED DISPLAY CASES INCLUDING SELF CONTAINED UNITS AND WALK-IN COOLERIFREEZER PANELS AS PER T-1. I. REFRIGERATION CONTRACTOR TO PROVIDE, COORDINATE, SET, AND LEVEL EQUIPMENT SUPPORT RAILS AND PIPE PORTALS FOR ROOF TOP REFRIGERATION EQUIPMENT AS PER STRUCTURAL DRAWINGS. GC AND ROOFING CONTRACTOR RESPONSIBLE FOR FINAL INSFALLATION. J. SEE R401/R402/R501/R502 FOR ADDITIONAL INFORMATION ON BINS AND SENSORS. REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR PROGRAMMING OF BRIE K. REFRIGERATION CONTRACTOR TO REMOVE ALL ABANDONED, UNUSED REFRIGERATION PIPING, HANGERS, SUPPORTS, COMPRESSOR RACK, AND CONDENSERS. L COORDINATE DISPOSITION OF REMOVED EQUIPMENT WITH GIANT EAGLE- M. GC TO PROVIDE OPENING FOR ALL REFRIGERATION LINES TO COMPRESSOR ROOM, CONDENSORS AND CASES. KEY NOTES I]1 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL SUCTION LINE ISOLATION BALL VALVE AND LIQUID LINE ISOLATION BALL VALVE IN THE BRANCH LINES OF EACH CIRCUIT OVERHEAD. REFERENCE LOOP SCHEMATICS ON R-201- [21 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL EEPR, SUCTION LINE ISOLATION BALL VALVE AND LIQUID LINE ISOLATION BALL VALVE IN THE BRANCH LINES OF EACH CIRCUIT ON TOP OF CASE, UNDER CASE OR ON TOP OF COOLER/FREEZER. 0 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL EEPR/EPR VALVE AT RACK OR FOR FOR PROPOSED REFRIGERATION SYSTEM. 0 REFRIGERATION LINES TO RUN UNDERGROUND AND TRAP IN PIT AT RISER LOCATION. REFRIGERATION RISERS RUN IN THE WALUOR EXPOSED. COORDINATE WITH PLUMBING AND ELECTRICAL TRADES FOR LOCATION. REFERENCE DETAIL #11/R-302. © REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD ON TOP OF CASE(S), TRAP AT RISER LOCATION , RISE EXPOSED AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. REFERENCE DETAIL #12/R-301. © REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD ON TOP OF CASE(S), TRAP AT RISER LOCATION , RISE IN WALL AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. REFERENCE DETAIL #12/R-301. EZI REFRIGERATION LINES FROM CASE(S) TIE INTO MANIFOLD UNDER CASE(S), TRAP AT RISER LOCATION , RISE EXPOSED AND RUN OVERHEAD TO MAIN LOOP, RACK OR HDR. M INDIVIDUAL SUCTION LINES RUN TO RACK. LIQUID LINES RUN TO RECEIVER OR LIQUID LOOP. I]9 INSTALL DOUBLE SUCTION RISER. 10 TOP FEED ELECTRICAL. TOP FEED REFRIGERATION. 01 BOTTOM FEED ELECTRICAL. BOTTOM FEED REFRIGERATION. 12 REFRIGERATION RISERS RUN IN WALL/BULKHEAD. 13 RC TO PROVIDE INTERMEDIATE TRAP FOR SUCTION RISERS EXCEEDING 15'. 14INSTALL NEW EVAPORATOR COILS PROVIDED BY REFRIGERATION CONTRACTOR. REFERENCE DETAILS #8, #9 & #10/R-301. 15 REFRIGERATION CONTRACTOR SHALL FURNISH AND INSTALL LIQUID LINE ISOLATION BALL VALVE IN BRANCH LINES OF EACH CIRCUIT OVERHEAD. 16 REFRIGERATION PIPING ENCLOSURE. GC TO PROVIDE AND INSTALL. REFERENCE MECHANICAL DRAWINGS FOR ENCLOSURE DETAILS. ll I/O BOARDS AND SOLENOID VALVES ARE FACTORY INSTALLED PER CASE. IB RC TO PROVIDE AND INSTALL NEW TXV VALVE. UTRO BOARDS, TEMP SENSOR, SOLENOID VALVES AND EEPR VALVE ARE FACTORY INSTALLED PER ISLAND. O -•--•• ''1' 's UAlt REV. LOG REVISIONS 44 •.�p18Tf,�'-l�•.� NO. N0. 4 FoL 4 NO : O? 11500379,• DWG. TITLE REFRIGERATION PLAN M1 FS• A •; Gx a° PROJECT GIANT EAGLE #6550 LOCATION THE BRIDGES ISSUED FOR CONSTRUCTION -- 116 STREET & SPRING MILL ROAD ISSUED FOR BID 04/19/19 OWNER CARMEL, IN ISSUED FOR PERMIT 04/19/19 DATE ISSUED FOR REDLINE 04/03/19 ISSUED FOR 60 % FAZIO 3AWNEY '-0" D�wN� KICK OFF MEETING -- BMH 300 S. MAIN STREET, PITTSBURGH, PA 15215 (412) 782-6338 DESIGNED fir FINAL APPROVED PLAN FAZIOMECHANICAL.COM BMH T�