HomeMy WebLinkAboutS301GENERAL NOTES DESIGN LIVE LOADS DL-1 FLOOR LIVE LOADS SLAB ON GRADE .......................... 250 PSF DL-2 ROOF LIVE LOADS BASIC ROOF LIVE LOAD .................... 30 PSF DLJ ROOF SNOW LOADS GROUND SNOW LOAD ...................... 20 PSF FLAT ROOF SNOW LOAD .................... 20 PSF SNOW EXPOSURE FACTOR ..................... 1.0 SNOW LOAD IMPORTANCE FACTOR ............. 1.0 THERMAL FACTOR ..... ......... ........ 1.0 ALL SNOW LOADS ARE APPLIED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE AND ASCE 7-10. DL4 WIND LOADS ULTIMATE DESIGN WIND SPEED ............ 115 MPH NOMINAL DESIGN WIND SPEED .............. 90 MPH RISK CATEGORY ................................ II EXPOSURE CATEGORY .......................... B INTERNAL PRESSURE COEFFICIENT ............. 0.18 ALL WIND LOADS ARE APPLIED IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE AND ASCE 7-10. CAST -IN -PLACE CONCRETE C-1 ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) OF THE AMERICAN CONCRETE INSTITUTE. C-2 MINIMUM Pc REQUIRED AT 28 DAYS: INTERIOR SLABS ....................... 4000 PSI C-3 ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE(144 PCF±) WITH ALL CEMENT CONFORMING TO ASTM C150, TYPE I. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR FOOTINGS AND 3/4' FOR WALLS AND SLABS, CONFORMING TO ASTM C33. C4 REINFORCEMENT DEFORMED BARS ................. ASTM A615, GRADE 60 WELDED WIRE REINFORCEMENT ............. ASTM A1064 C-5 ALL LEVELING GROUT SHALL BE NON-METALLIC SHRINK -RESISTANT GROUT COMPLYING WITH ASTM C1107, AND SHALL HAVE A MINIMUM Pc OF 5000 PSI. C-6 MINIMUM CONCRETE COVER FOR REINFORCING STEEL SLABS AND WALLS ..... ... .. 3/4" BEAMS . .... .. .. 1-1/2" CONCRETE EXPOSED TO WEATHER #5 BARS AND SMALLER ..................... 1-1/2' BARS LARGER THAN #5........................ 2" CONCRETE IN CONTACT WITH EARTH ................ 3" ALL WELDED WIRE REINFORCEMENT IS TO BE PLACED 1-1/2" FROM TOP OF SLABS. C-7 CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CONCRETE OPENINGS AND/OR PENETRATIONS REQUIRED FOR OTHER TRADES PRIOR TO PLACING CONCRETE. CE CONDUITS OR PIPES EMBEDDED IN SLABS SHALL NOT HAVE AN OUTSIDE DIMENSION LARGER THAN 1/3 THE SLAB THICKNESS AND SHALL BE SPACED NO CLOSER THAN 3 DIAMETERS ON CENTER. ALUMINUM CONDUITS SHALL NOT BE EMBEDDED IN CONCRETE. A-1 ALL EXPANSION ANCHORS SHALL BE 'HILTI KWIK-BOLT III' (AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC.) OR AN APPROVED EQUAL, MEETING THE REQUIREMENTS OF FEDERAL SPECIFICATION FF-S-325, GROUP II, TYPE 4, CLASS 1. A-2 ALL ANCHOR SPACING, EMBEDMENT, EDGE DISTANCE, AND INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REFER TO SECTIONS AND DETAILS ON THE DRAWINGS FOR ADDITIONAL INFORMATION. LIGHT GAGE STEEL STUDS LS-1 ALL LIGHT GAGE STEEL FRAMING WORK SHALL MEET THE REQUIREMENTS OF THE "DESIGN OF COLD FORMED STRUCTURAL STEEL MEMBERS" OF THE AMERICAN IRON AND STEEL INSTITUTE (AISI), 2012 EDITION. LS-2 ALL 16 GAGE STEEL STUDS SHALL BE GALVANIZED, AND SHALL BE FORMED FROM STEEL THAT MEETS THE REQUIREMENTS OF ASTM A 653, GRADE A, WITH A MINIMUM YIELD STRENGTH OF 50,000 PSI. LS-3 PROVIDE STUD BRIDGING IN COMPLIANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER, BUT DO NOT EXCEED 5'-0" VERTICAL SPACING BETWEEN ROWS OF BRIDGING. LS4 PROVIDE DOUBLE STUDS ON BOTH SIDES OF ALL WALL OPENINGS EXCEEDING 16' IN WIDTH. LS-5 PROVIDE RIGID CONNECTION CLIPS AT BASE OF ALL LOW WALL STUDS. ALL RIGID CONNECTIONS SHALL BE CLARK DIETRICH MOMENT CLIPS, OR AN APPROVED EQUAL WITH THE FOLLOWING MINIMUM PROPERTIES: F1(SHEAR)................................... 1903 lbs F2 (TENSION) ................................. 3417 Ibs MOMENT .................................. 5763 in-lbs LS46 FASTEN RIGID CONNECTIONS TO STUDS WITH A MINIMUM OF(6)#12 SCREWS. FASTEN TO CONCRETE SLAB WITH (1) 1/2" DIAMETER HILTI KWIK BOLT III IN EACH CLIP (21/4' MINIMUM EMBEDMENT). MISCELLANEOUS Z-1 VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION OF ANY STRUCTURAL COMPONENTS. IMMEDIATELY NOTIFY THE ENGINEER AND ARCHITECT OF ANY DISCREPANCIES FOUND DURING FIELD VERIFICATION. Z-2 ALL STRUCTURAL WORK SHALL CONFORM TO INFORMATION SHOWN ON THE STRUCTURAL DRAWINGS. HOWEVER, THE ARCHITECTURAL DRAWINGS SHALL GOVERN ALL DIMENSIONS. Z-3 USE EXTREME CAUTION DURING THE DEMOLITION OF EXISTING STRUCTURES. DEMOLITION AND EXCAVATION SHALL BE CARRIED OUT BY METHODS THAT W ILL NOT AFFECT THE INTEGRITY OF EXISTING STRUCTURES TO REMAIN. PROVIDE SHORING AND BRACING WHERE REQUIRED. PCF-1 SUBMIT MANUFACTURER'S PRODUCT DATA SHEETS ON ALL PRODUCTS TO BE USED FOR THE WORK. SUBMIT DESCRIPTION FOR PROTECTION OF SURROUNDING AREAS, SURFACE PREPARATION, APPLICATION, AND FINAL CLEANING. PCF-2 AGGREGATE EXPOSURE: MOTTLED SALT -AND -PEPPER FINE AGGREGATE EXPOSURE TO MATCH EXISTING. PCF-3 SPECULAR GLOSS/ REFLECTIONS CRITERIA ACCORDING TO ASTM D523: a. SPECIFIED OVERALL GLOSS VALUE (SOGV) ............ 40 b. MINIMUM LOCAL GLOSS VALUE (MLGV) ................ 30 c. GLOSS MEASUREMENT TO BE TAKEN INDEPENDENT OF AMBIENT LIGHTING AND WITHIN A SEALED MEASUREMENT WINDOW LOCATED BENEATH THE TEST UNIT. d. TEST SPECULAR GLOSS/ REFLECTANCE AT TURNOVER. PCF-0 DURABILITY CRITERIA: a. ABRASION RESISTANCE: ASTM C779 - UP TO 400% INCREASE IN ABRASION RESISTANCE. In. IMPACT STRENGTH: ASTM C805 - UP TO 21 % INCREASE IN IMPACT STRENGTH. G. ULTRA VIOLET LIGHT AND WATER SPRAY: ASTM G23-18 - NO ADVERSE EFFECT TO ULTRA VIOLET AND WATER SPRAY. PCF-5 SLIP RESISTANCE CRITERIA: a. STATIC COEFFICIENT OF FRICTION: ANSI B101.1 - MEET OR EXCEED 0.6 WET FOR FLATAREAS. In. TEST SLIP RESISTANCE AT TURNOVER. PCF46 PENETRATING HARDENER/ DENSIFIER: CLEAR LIQUID REACTIVE LITHIUM -SILICATE BASED. a. CONSOLDECK 2320 LITHIUM DENSIFIER, OR APPROVED EQUAL. PCF-7 JOINT FILLER: HI -TECH SYSTEMS HT-PE65, HT-PE85, OR APPROVED EQUAL TO MATCH EXISTING. PCF-8 CRACK AND SPALL REPAIR PRODUCT: HI -TECH SYSTEMS SPALL TX3 OR APPROVED EQUAL TO MATCH EXISTING. PCF-9 EXAMINE FLOOR SUBSTRATES TO RECEIVE POLISHED CONCRETE FLOOR SYSTEM. DO NOT BEGIN SURFACE PREPARATION OR INSTALLATION UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED AND APPROVED. PCF-10 PROTECT SURROUNDING AREAS AND ADJACENT SURFACES FROM DUST, CONTACT W ITH OVERSPRAY OF DENSIFIER AND CONTACT WITH JOINT FILLER, CRACK, OR SPALL REPAIR MATERIALS. PCF-11 SURFACE PREPARATION PRODUCTS SHALL INCLUDE THE FOLLOWING: CONSOLIDECK WAX & CURE REMOVER CONSOLDECK CLEANER/DEGREASER CONSOLDECK CONCRETE FLOOR RESTORER CONSOLDECK OIL AND GREASE STAIN REMOVER PCF-12 CLEAN DIRT, DUST, OIL, GREASE AND OTHER CONTAMINANTS FROM SURFACES THAT INTERFERE WITH PENETRATION OR PERFORMANCE OF SPECIFIED PRODUCT. USE APPROPRIATE CONCRETE CLEANERS APPROVED BY THE CONCRETE SURFACE TREATMENT MANUFACTURER WHERE NECESSARY. RINSE THOROUGHLY USING PRESSURE WATER SPRAY TO REMOVE CLEANER RESIDUES. ALLOW SURFACES TO DRY COMPLETELY BEFORE APPLICATION OF PRODUCT. PCF-13 INSTALL JOINT FILLER IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, UNLESS JOINTS ARE TO BE FILLED AFTER GRINDING AND POLISHING. PCF-14 CONTRACTOR SHALL POLISH AND APPLY DENSIFIER, CRACK AND SPALL REPAIRS AND GROUT COATS IN ACCORDANCE WITH APPROVED POLISHED CONCRETE FLOOR PROCEDURE SUBMITTAL, AND SHALL ACHIEVE SPECIFIED APPEARANCE AND DURABILITY REQUIREMENTS. PCF-15 PROTECT COMPLETED POLISHED CONCRETE FLOOR SYSTEM FROM DAMAGE UNTIL SUBSTANTIAL COMPLETION. PCF-16 REPAIR DAMAGED AREAS OF COMPLETED POLISHED CONCRETE FLOOR SYSTEM TO SATISFACTION OF CONSTRUCTION REPRESENTATIVE. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel (� �v Gla#1dAaA�+L. W/ (5) SCREWS BOX HEADER WITH WEB STIFFENERS (SEE SCHEDULE AND DETAIL'C') HEADERATTACHMENT (SEE SCHEDULE) REMOVE FLANGE OF VERTICAL TRACK AT INTERSECTION WITH HORIZONTAL TRACK W/ (5) SCREWS JAMB STUDS ATTACHED WITH TRACK (SEE SCHEDULE FOR NUMBER OF STUDS AND DETAIL -B-) TYPICAL BOXED HEADER CONNECTION SCALE: NOT TO SCALE LIGHT GAGE HEADER SCHEDULE MAXIMUM MEMBER TRACK FULLHEIGHT HEADER MARK ATTACHMENT OPENING SIZE SIZE STUDS DETAIL H1 1 6-0' 1 (2)600S162-54 I 60OT125-54 I (2)600S162-54 A NOTES: 1. USE THIS SCHEDULE TO SIZE HEADERS DEPICTED ON THE STRUCTURAL PLANS. CLARK DEITRICH RIGID CONNECTION CLIP MC975 W/ 1/2" DIA. HILTI KW IK BOLT 3 EXPANSION ANCHOR 6", 16 GAGE LT. GA. MTL STUDS @ 16" O.C. EXIST. CONC. SLAB ON GRADE TYPICAL 6" LOW WALL CONSTRUCTION DETAIL SCALE: 3/4" - V-0" SECTION OF RUNNER TRACK FOR ATTACHMENT OF HEADER TO FULL HEIGHT OF STUD DETAIL"A" (HEADER ATTACHMENT) TOOLED EDGE '.E REINFORCING PREFORMED KEYED JOINT WELDED WIRE REINFORCING :LAB-ONGRADE CONCRETE SLAB -ON -GRADE 4 L 6 IER VAPOR BARRIER GRAVEL COMPACTED GRAVEL TYPICAL SLAB -ON -GRADE CONSTRUCTION TYPICAL SLAB -ON -GRADE CONSTRUCTION JOINT SINGLE TRACK TO MATCH JAMB STUD SIZE AND GAGE SCALE: NO SCALE SCALE: NO SCALE OF STUDS NOTE: REFER TO THE GEOTECHNICAL REPORT FOR ADDITIONAL INFORMATION REGARDING THE SUBGRADE PREPARATION. FULL HEIGHT STUDS (SEE SCHEDULE) DETAIL "B" (JAMB STUDS) CAP TRACK SAW CUT, 1/8"x3/4"DEEP CUT ALTERNATE WIRES DISCONTINUOUS CONTROL W/MASTIC SEALANT AT TOP BELOW JOINT JOINT (SEE PLAN) OR INSERT PREMOULDED CONTROL WEB STIFFINERS STRIP DURING POUR WELDED WIRE REINFORCING (SEE PLAIN) AT END BEARINGS '' LIGHT GAGE STEEL CONCRETE SLAB -ON -GRADE JOISTS PER SCHEDULE BASE TRACK a4 (2) #4 BARS 6 x 3'-0" LONG 1 (TYPICAL UNCH (TYPICAL) DETAIL"C" o VAPOR BARRIER (TYPICAL LIGHT GAGE HEADER) COMPACTED GRAVEL TYPICAL SLAB -ON -GRADE REINFORCEMENT TYPICAL SLAB -ON -GRADE CONTROL JOINT AT DISCONTINUOUS CONTROL JOINT SCALE: NO SCALE SCALE: NO SCALE CONC. SLAB -ON -GRADE (SEE PLAN) #3 DOWELS @ 24" 1 VAPOR BARRIER (DRILL & EPDXY GROUT 9INTO EXIST. SLAB) COMPACTED GRANULAR SUBBASE MATERIAL 1'-6- 9. 1' 3- WELDED WIRE REINFORCEMENT EXIST. COR/ SLAB -ON -GRADE TO REMAIN V #3 DOWELS @ 24" O.C. DRILL & EPDXY GROUT INTO EXIST. SLAB -ON -GRADE (9" MIN. EMBED.) T 9• 1 _3• #4 @ 16" O.C. EXIST. CONC. .B TO REMAIN it#4 BARS CONT. #3 DOWELS @ 24" O.C. DRILL& EPDXY GROUT INTO EXIST. SLAB -ON -GRADE '4 (9" MIN. EMBED.) , TYPICAL SLAB -ON -GRADE REPLACEMENT TIE-IN DETAILS SCALE: NO SCALE ```50 \p R I r' -z �pryi Q`t• ?�G\B7EgfQ ye, e No. PE11500090 •; .o STATE OF Q' rX -o DATE REV. SPCR REVISIONS BY NO. NO. DWG. TITLE GENERAL NOTES AND TYPICAL DETAILS PROJECT GIANT EAGLE MARKET DISTRICT #6550 LOCATION THE BRIDGES DEVELOPMENT e ISSUED FOR CONSTRUCTION — 11505 ILLINOIS STREET CARMEL, IN 46032 ISSUED FOR BID 04-03-19 OWNER GIANT EAGLE, INC. ISSUED FOR PERMIT 04-03-19 mm 04 03 19 PawEcr No v P6550 v' ISSUED FOR REDLINE REVIEW — Taylor Structural Engineers, Inc. ISSUED FOR 50 % — 2275 Swallow Hill Road, Building 100 scaE aHEU an TSEPhone: Pittsburgh, Pennsylvania 15220 (412)722-0880 3/41=1-011 2 KICK OFF MEETING — Pax: eallo..:57032 TSEFax Project No.: -08 S301 3 na.,mw FINAL APPROVED PLAN — BPB p DATE: 05/03/19