Loading...
HomeMy WebLinkAboutSPP100.0e'�STOEFFELWERTH B ® =r' ALWAYS ON 7965 East 106th Street, Fishers, IN 46038-2505 phone: 317.849.5935 fax: 317.849.5942 T.C.= 755.97 AS BUILT — 39.00 (SLAB) (RH) o o —-------� STORM SEWER 8.00 A O 3/4" WATER CONNECTION 758.20 D • SANITARY MANHOLE a6 in N 57.2 ''Tv O 1.0' u7 15' D.&U.E. BUILDING LINE R.A.E. 57.2 15.16' 57.OAB SONC. o MH PEDESTRIAN ACCESS EASEMENT 12.67 p DRAINAGE, UTILITY & SANITARY 0 SEWER EASEMENT COVERED o 57.2 10-) PATIO 55.6AB LOT 54 O 0' MINIMUM SIDE YARD EXIST. HSE. 0 15.16' 18.2' 6' MINIMUM REAR YARD LOT 52 PROP. HSE. 6"S.C.. AS BUIL 205'± 10' B.L. L MH 10' D.U.&S.S.E. 26 7 mw 56.2A6 T.C.= 758.49 AS BUILT 1 5'SW MODEL=SOHO n F.F.ELEV.=758.53 _ SUB—SURFACE DRAIN (SLAB) (RH) o SANITARY SEWER .6 STORM SEWER 8.00 WATER MAIN GAR. 3/4" WATER CONNECTION 758.20 SWALE • SANITARY MANHOLE o p N 0 ''Tv O 1.0' u7 0.3 ' BUILDING LINE R.A.E. 57.2 u 16' 57.OAB SONC. o MH PEDESTRIAN ACCESS EASEMENT P RCH DRIVE �0 724 DRAINAGE, UTILITY & SANITARY 0 SEWER EASEMENT T.C.= 757.23 MINIMUM FINISHED FLOOR 3'SW AS BUILT MINIMUM LOWEST ADJACENT 55.6AB 41.00 JA ES DEAN DRIVE M p 56.47 Ln 56.75 W W W- 5'SW JOB ID GLEG2.53 CONTROL# 87043 PYA 14261 JAMES DEAN DRIVE CARMEL, IN 46033 1" = 20' LOT AREA: 3,610 Sq. Ft. M.F.F.-758.0 M.L.A.G.=757.3 LEGEND: XX.X PROPOSED GRADE PER PLAN XX.XAB AS BUILT GRADE — S.S.D. — _ SUB—SURFACE DRAIN =_80040474 _ - SANITARY SEWER N/A f Sq. Ft. STORM SEWER W WATER MAIN W 3/4" WATER CONNECTION 0 0 o SWALE • SANITARY MANHOLE 4) STORM MANHOLE ■ CURB INLET ''Tv FIRE HYDRANT D.&U.E. DRAINAGE & UTILITY EASEMENT B.L. BUILDING LINE R.A.E. RECIPROCAL ACCESS EASEMENT I.E.E. INGRESS/EGRESS EASEMENT P.A.E. PEDESTRIAN ACCESS EASEMENT D.U.&S.S.E. DRAINAGE, UTILITY & SANITARY SEWER EASEMENT M.F.F. MINIMUM FINISHED FLOOR M.L.A.G. MINIMUM LOWEST ADJACENT GRADE BENCHMARK TOP OF CASTING = 758.49 SOD: 1,599 t Sq. Ft. =_80040474 _ - SEEDING: N/A f Sq. Ft. = = CONC. DRIVEWAY: 536 ± Sq. Ft. STATE OF PRIVATE WALK: 30 ± Sq. Ft. ALL UNDERGROUND SEWERS AND UTILITIES SHOWN ARE PLOTTED BY SCALE FROM ��-9�••"'••. NDIANP: � �Q��♦ i -y • ••••••'•!4 O PUBLIC WALK: 125 f Sq. Ft. "RECORD DRAWINGS" FURNISHED BY ENGINEER. S'U Rv `♦♦O♦♦ LOT 53 ......,...... ���� THE GROVE AT THELEGACY SECTION TWO INST. #2018030350 NOTE: THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL P.C. 5, SLIDE 852 BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATION REPORT. C.O.C. #2018032617, 2018045272, 2018013393 04/11/19 CCN ZONING: PUD `. 0' MINIMUM SIDE YARD 6' MINIMUM BETWEEN STRUCTURE 6' MINIMUM REAR YARD IGwwcallseforey I;alt before you dig.