HomeMy WebLinkAboutBCE 087 - Energy Certificate4469 EVERGREEN TRL
!J fT 1'a RN FWATJ I =111r11'1
CARMEL, IN 46074
Builder: PULTE HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 415.0 CFM @ 25Pa
Total Duct Leakage 553.0 CFM i@ 25Pa
Heating Furnace • Natural Gas • 93 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.7 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
3122119 at 11:49 AM
Ekotrope RATER - Version 3.1.0.2136
20091ECC compliance results calculated using Ekotrope RATER's energy arrd code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.