Loading...
HomeMy WebLinkAboutI36743383.J1990155416023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). April 15,2019 Johnson, Andrew Pages or sheets covered by this seal: I36743383 thru I36743428 My license renewal date for the state of Indiana is July 31, 2020. J19901554 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: JACKSON'S GRANT 69 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743383 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-AnwgXcI2bZFd4P5BXXBzgEumbdIWJaiwI5S4e_zQUe? Scale = 1:14.5 1 2 3 4 7 6 8 9 10 11 5 2x4 2x4 2x4 2x4 Special Special Special Special 4-9-12 4-9-0 -2-8-7 2-8-7 4-9-12 4-9-12 0-10-142-4-23.58 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.64 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7=405/0-6-5, 5=131/Mechanical Max Horz 7=66(LC 4) Max Uplift 7=-81(LC 7), 5=-5(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-347/100 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15 lb down and 24 lb up at 1-7-15, and 38 lb down and 12 lb up at 3-0-7 on top chord, and at 1-7-15, and 5 lb down and 8 lb up at 3-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 11=7(B) April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743384 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ezU2kyJgMtNUhZgN4FiCCRR3I1gI2zr4XlBdBRzQUe_ Scale: 1/4"=1'Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 4x6 3x4 22-0-0 22-0-0 -1-2-8 1-2-8 11-0-0 11-0-0 22-0-0 11-0-0 23-2-8 1-2-8 0-10-148-2-140-10-148.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.06 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.01 0.00 (loc) 17 17 18 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 322 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 22-0-0. (lb) - Max Horz 33=-147(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 33, 18, 28, 29, 30, 31, 32, 23, 22, 21, 20, 19 Max Grav All reactions 250 lb or less at joint(s) 33, 18, 25, 27, 28, 29, 30, 31, 32, 24, 23, 22, 21, 20, 19 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-2-8 to 1-9-8, Exterior(2) 1-9-8 to 11-0-0, Corner(3) 11-0-0 to 14-0-0, Exterior(2) 14-0-0 to 23-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 18, 28, 29, 30, 31, 32, 23, 22, 21, 20, 19. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE02 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743385 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-692RyIKI7AVLJjFaeyDRlfzBGRtqnNRDmPxAitzQUdz Scale = 1:42.7Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 8 7 6 25 26 27 5 28 3x6 8x8 5x6 5x8 3x6 3x4 3x6 3x6 3x6 3x6 2-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 17-6-8 1-2-7 2-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 17-6-8 1-2-7 2-1-09-4-80-8-91-4-00-0-92-1-210.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.62 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.29 0.10 (loc) 4-6 4-6 5 l/defl >999 >724 n/a L/d 240 180 n/a PLATES MT20 Weight: 255 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x10 SP No.1 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=743/0-3-8, 5=765/0-3-8 Max Horz 8=-160(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-712/35, 1-2=-1198/65, 2-3=-822/74, 3-4=-769/53, 4-5=-346/26 BOT CHORD 6-7=-22/901, 4-6=0/546 WEBS 1-7=-9/909, 2-6=-370/117, 3-6=0/410 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 8-9-0, Exterior(2) 8-9-0 to 11-9-0, Interior(1) 11-9-0 to 17-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Bearing at joint(s) 8, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE03 Truss Type GABLE Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743386 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-aMcp9eKxuUdCxtqmCglgHsWIhrChWuKM?3gkEJzQUdy Scale = 1:59.5Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 3x8 3x6 3x6 3x6 10-0-8 10-0-8 1-10-1410-3-510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.59 0.58 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 199 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 8-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10, 8-11 REACTIONS. All bearings 10-0-8. (lb) - Max Horz 18=271(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 11, 12, 13, 14, 15, 16 except 18=-462(LC 7), 10=-104(LC 8), 17=-663(LC 6) Max Grav All reactions 250 lb or less at joint(s) 10, 11, 12, 13, 14, 15, 16 except 18=795(LC 6), 17=437(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-18=-763/235, 1-2=-750/232, 2-3=-417/129, 3-4=-356/110, 4-5=-316/99, 5-6=-270/85 WEBS 2-17=-177/511 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-1-12 to 3-4-8, Exterior(2) 3-4-8 to 9-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 12, 13, 14, 15, 16 except (jt=lb) 18=462, 10=104, 17=663. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE04 Truss Type Monopitch Supported Gable Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743387 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-2Y9BN_LZfol3Y1PymNGvq43anEgnFNhWDjQHmlzQUdx Scale = 1:17.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 5 4 2x4 2x4 2x4 2x4 -1-2-8 1-2-8 2-0-0 2-0-0 1-1-52-9-510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 5=182/2-0-0, 4=36/2-0-0 Max Horz 5=76(LC 6) Max Uplift 5=-28(LC 9), 4=-39(LC 6) Max Grav 5=182(LC 1), 4=46(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE05 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743388 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-WkjZaKMBQ5twAA_9J4n9NHbgaew8_hAfSN9qJCzQUdw Scale = 1:46.3Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 10 9 8 7 6 25 26 27 3x6 4x6 3x6 5x6 5x6 3x6 3x8 3x6 2-1-21-7-22-9-10 2-9-10 9-9-0 6-11-6 16-4-1 6-7-1 18-6-8 2-2-7 2-9-10 2-9-10 9-9-0 6-11-6 16-4-1 6-7-1 18-6-8 2-2-7 2-1-010-2-82-4-90-6-01-7-210.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.45 0.63 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.18 0.10 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 279 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 10=730/0-3-8, 6=730/0-3-8 Max Horz 10=184(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-704/71, 1-2=-1225/146, 2-3=-733/89, 3-4=-724/102, 4-5=-853/71, 5-6=-712/49 BOT CHORD 8-9=-150/929, 7-8=-83/673 WEBS 1-9=-77/950, 2-9=-79/254, 2-8=-499/187, 3-8=-3/458, 4-8=-266/119, 5-7=-67/697 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 18-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 10, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE06 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743389 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?wHxngNpBP0noKZLtoIOvV8mP2B5j3Nph1vOrezQUdv Scale = 1:58.2 Sheet Front Right Option 9-2-8 1 Ply 7/16OSB8 1 2 3 4 5 6 13 12 11 109 8 22 23 24 7 3x8 4x6 8x10 5x6 3x6 3x6 10x10 4x10 5x12 5x6 3x6 3x6 11-8-82-1-112-9-10 2-9-10 9-9-0 6-11-6 14-5-3 4-8-3 18-7-8 4-2-5 20-11-14 2-4-6 27-10-0 6-10-2 2-9-10 2-9-10 8-1-3 5-3-9 9-9-0 1-7-13 14-5-3 4-8-3 20-11-14 6-6-10 27-10-0 6-10-2 32-1-8 4-3-8 2-0-46-2-1410-1-120-8-111-1-20-3-52-1-210.00 12 3.00 12 10.00 12 Plate Offsets (X,Y)-- [5:0-5-0,0-7-8], [10:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.82 0.79 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.51 -1.30 0.56 (loc) 6-8 6-8 7 l/defl >752 >294 n/a L/d 240 180 n/a PLATES MT20 Weight: 274 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x10 SP No.1, 5-7: 2x10 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 *Except* 6-10: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 5-9, 4-11 REACTIONS. (lb/size) 13=1273/0-3-8, 7=1275/0-3-8 Max Horz 13=-180(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-1247/31, 1-2=-2242/79, 2-3=-1611/87, 3-4=-1572/109, 4-5=-2833/85, 5-6=-4715/81 BOT CHORD 11-12=-44/1702, 9-11=0/2732, 8-9=-19/4658, 6-8=-24/4650 WEBS 1-12=-28/1736, 2-12=0/350, 4-9=0/662, 5-9=-2030/43, 5-8=0/304, 3-11=-17/1563, 4-11=-2039/85, 2-11=-594/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 31-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 13, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE07 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743390 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?wHxngNpBP0noKZLtoIOvV8mP2B5j3Nph1vOrezQUdv Scale = 1:58.2 Sheet Back Right Option 9-2-8 1 Ply 7/16OSB8 1 2 3 4 5 6 13 12 11 109 8 22 23 24 7 3x8 4x6 8x10 5x6 3x6 3x6 10x10 4x10 5x12 5x6 3x6 3x6 11-8-82-1-112-9-10 2-9-10 9-9-0 6-11-6 14-5-3 4-8-3 18-7-8 4-2-5 20-11-14 2-4-6 27-10-0 6-10-2 2-9-10 2-9-10 8-1-3 5-3-9 9-9-0 1-7-13 14-5-3 4-8-3 20-11-14 6-6-10 27-10-0 6-10-2 32-1-8 4-3-8 2-0-46-2-1410-1-120-8-111-1-20-3-52-1-210.00 12 3.00 12 10.00 12 Plate Offsets (X,Y)-- [5:0-5-0,0-7-8], [10:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.82 0.79 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.51 -1.30 0.56 (loc) 6-8 6-8 7 l/defl >752 >294 n/a L/d 240 180 n/a PLATES MT20 Weight: 274 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x10 SP No.1, 5-7: 2x10 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 *Except* 6-10: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 5-9, 4-11 REACTIONS. (lb/size) 13=1273/0-3-8, 7=1275/0-3-8 Max Horz 13=-180(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-1247/31, 1-2=-2242/79, 2-3=-1611/87, 3-4=-1572/109, 4-5=-2833/85, 5-6=-4715/81 BOT CHORD 11-12=-44/1702, 9-11=0/2732, 8-9=-19/4658, 6-8=-24/4650 WEBS 1-12=-28/1736, 2-12=0/350, 4-9=0/662, 5-9=-2030/43, 5-8=0/304, 3-11=-17/1563, 4-11=-2039/85, 2-11=-594/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 31-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 13, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE08 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743391 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:09 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-T7rK?0NRxj8ePU8XRVpdSih04SeFSbzyvhexN4zQUdu Scale = 1:52.0Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 13 12 11 10 9 8 7 32 33 34 3x6 4x6 3x6 5x6 3x6 3x6 4x8 6x8 6x8 3x6 2-9-10 2-9-10 9-9-0 6-11-6 12-3-0 2-6-0 15-10-12 3-7-12 19-10-0 3-11-4 2-9-10 2-9-10 9-9-0 6-11-6 12-3-0 2-6-0 15-10-12 3-7-12 19-10-0 3-11-4 2-1-010-2-811-2-82-9-101-0-03-1-23-1-210.00 12 10.00 12 Plate Offsets (X,Y)-- [10:0-6-0,0-3-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.35 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.04 (loc) 11-12 11-12 7 l/defl >999 >816 n/a L/d 240 180 n/a PLATES MT20 Weight: 326 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 13=451/0-3-8, 7=226/0-3-8, 10=887/0-3-8 Max Horz 13=203(LC 8) Max Uplift 13=-3(LC 9), 7=-13(LC 9) Max Grav 13=451(LC 1), 7=238(LC 14), 10=887(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-427/30, 1-2=-751/76, 2-3=-279/81, 5-6=-268/4 BOT CHORD 12-13=-259/232, 11-12=-177/567, 4-10=-696/49 WEBS 1-12=-24/587, 2-11=-483/170, 4-11=0/439, 5-10=-275/81 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 19-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 13, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 7. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE09 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743392 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-xJPiCLO3i0GV1ejk?DKs_wD9ws?mBAk68LOVwXzQUdt Scale = 1:56.7 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 3x4 3x6 3x4 3x4 -1-2-8 1-2-8 9-11-8 9-11-8 1-1-59-4-1410.00 12 Plate Offsets (X,Y)-- [9:0-0-11,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.62 0.26 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 173 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 9-10: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10 REACTIONS. All bearings 9-11-8. (lb) - Max Horz 17=261(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 17, 10, 11, 12, 13, 14 except 16=-172(LC 6) Max Grav All reactions 250 lb or less at joint(s) 10, 11, 12, 13, 14, 15, 16 except 17=271(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-17=-331/65, 2-3=-480/146, 3-4=-328/102, 4-5=-310/97, 5-6=-262/83 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-2-8 to 1-11-8, Exterior(2) 1-11-8 to 9-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 10, 11, 12, 13, 14 except (jt=lb) 16=172. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE10 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743393 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PVz4QhPhTKOMfoHwYws5X7mOgFE4wZKFN?72SzzQUds Scale = 1:59.9Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 8 7 6 26 27 28 29 4x6 3x4 3x8 3x4 4x6 5x6 5-4-15 5-4-15 5-7-4 0-2-5 15-3-4 9-8-0 -1-2-8 1-2-8 5-4-15 5-4-15 10-2-6 4-9-6 15-3-4 5-0-14 0-7-42-10-511-0-1410-9-60-3-811-0-145.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-1,0-5-11], [2:0-0-0,0-0-1], [5:0-0-11,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.64 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.48 -0.00 (loc) 6-7 6-7 6 l/defl >562 >248 n/a L/d 240 180 n/a PLATES MT20 Weight: 266 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 5-6: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 9-10: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6 REACTIONS. All bearings 5-7-4 except (jt=length) 6=0-1-8. (lb) - Max Horz 2=299(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2 except 8=-511(LC 1), 6=-102(LC 6) Max Grav All reactions 250 lb or less at joint(s) except 2=281(LC 1), 7=1232(LC 1), 7=1232(LC 1), 8=510(LC 1), 6=429(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-7=-310/117 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 15-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 8=511, 6=102. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss GE11 Truss Type GABLE Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743394 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-tiXSd1QKEeWDHys66eNK4LIZTfg1f4VOcftb_PzQUdr Scale = 1:57.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 3x4 3x6 3x4 3x8 13-11-12 13-11-12 -1-2-8 1-2-8 5-4-15 5-4-15 13-11-12 8-6-13 0-7-42-10-510-0-05.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-1,0-5-11], [2:0-0-0,0-0-1], [12:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.30 0.28 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.01 0.02 0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 213 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 10-13: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-12, 10-13 REACTIONS. All bearings 13-11-12. (lb) - Max Horz 2=269(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19 Max Grav All reactions 250 lb or less at joint(s) 12, 2, 13, 14, 15, 16, 17, 18 except 19=392(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-391/119, 3-4=-317/95, 4-5=-303/93, 5-6=-352/117, 6-7=-298/98, 7-8=-255/85 WEBS 3-19=-273/146 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-2-8 to 1-9-8, Exterior(2) 1-9-8 to 13-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 2, 13, 14, 15, 16, 17, 18, 19. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J01 Truss Type Jack-Open Qty 4 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743395 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Lu5qrNQy?xe3u5RIgLuZcYrmZ34rOYQYqJc9WrzQUdq Scale = 1:14.9 1 2 5 6 3 4 2x4 2x4 2-2-8 2-2-8 -1-2-8 1-2-8 2-2-8 2-2-8 0-10-142-4-91-11-52-4-98.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.15 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=189/0-3-8, 3=38/Mechanical, 4=14/Mechanical Max Horz 5=75(LC 9) Max Uplift 5=-14(LC 9), 3=-18(LC 9) Max Grav 5=189(LC 1), 3=38(LC 1), 4=36(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J02 Truss Type Jack-Open Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743396 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:13 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Lu5qrNQy?xe3u5RIgLuZcYrnv33NOYQYqJc9WrzQUdq Scale = 1:10.2 1 2 5 3 4 2x4 2-10-13 2-10-13 -1-2-8 1-2-8 2-10-13 2-10-13 0-6-11-5-101-1-71-5-114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=60/Mechanical, 2=209/0-3-8, 4=27/Mechanical Max Horz 2=33(LC 9) Max Uplift 3=-13(LC 9), 2=-32(LC 9) Max Grav 3=60(LC 1), 2=209(LC 1), 4=54(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 2-10-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J03 Truss Type Jack-Open Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743397 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-p4eD2jRamFmwWF0VE3Po9mOxRTQM7?gh3zMi3IzQUdp Scale = 1:12.1 1 2 5 3 42x4 2x4 1-4-11 1-4-11 -1-2-8 1-2-8 1-4-11 1-4-11 0-10-141-10-01-4-131-10-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.14 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=175/0-3-8, 3=3/Mechanical, 4=2/Mechanical Max Horz 5=63(LC 9) Max Uplift 5=-21(LC 9), 3=-11(LC 6), 4=-3(LC 9) Max Grav 5=175(LC 1), 3=9(LC 7), 4=20(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J04 Truss Type MONO TRUSS Qty 3 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743398 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-p4eD2jRamFmwWF0VE3Po9mOxqTPi7?gh3zMi3IzQUdp Scale = 1:17.0 1 2 3 5 4 2x4 2x4 2x4 2x4 -1-2-8 1-2-8 2-0-0 2-0-0 1-1-52-9-52-5-130-3-82-9-510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.18 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 5=182/0-3-8, 4=36/0-1-8 Max Horz 5=76(LC 6) Max Uplift 5=-28(LC 9), 4=-39(LC 6) Max Grav 5=182(LC 1), 4=46(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J05 Truss Type MONO TRUSS Qty 19 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743399 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IHCbG3SCXZun8Pbhnmw1hzw3DtjjsMErId5GbkzQUdo Scale = 1:55.0 1 2 3 6 5 4 7 8 3x6 3x4 3x6 3x4 2x4 5x6 5-0-4 5-0-4 10-0-8 5-0-4 5-0-4 5-0-4 10-0-8 5-0-4 1-7-61-10-1410-3-50-3-89-11-130-3-810-3-510.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.33 0.21 0.43 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.04 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-9-15 oc bracing. WEBS 1 Row at midpt 3-4 REACTIONS. (lb/size) 6=390/0-1-8, 4=390/0-1-8 Max Horz 6=271(LC 6) Max Uplift 4=-99(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-340/74, 1-6=-347/72 BOT CHORD 5-6=-437/164 WEBS 2-4=-305/170, 1-5=-20/251 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss J07 Truss Type Jack-Closed Qty 5 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743400 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IHCbG3SCXZun8Pbhnmw1hzw1jtf0sNzrId5GbkzQUdo Scale = 1:31.0 1 2 3 4 5 7 6 8 9 5x12 3x4 3x63x42x4 6-11-15 6-11-15 14-0-0 7-0-1 -1-2-8 1-2-8 6-11-15 6-11-15 14-0-0 7-0-1 0-6-15-2-14.00 12 Plate Offsets (X,Y)-- [4:0-0-0,0-1-12], [4:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.49 0.45 0.38 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.17 0.02 (loc) 6-7 2-7 6 l/defl >999 >956 n/a L/d 240 180 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS. (lb/size) 6=544/Mechanical, 2=634/0-3-8 Max Horz 2=137(LC 6) Max Uplift 2=-22(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1006/30 BOT CHORD 2-7=-116/887, 6-7=-116/887 WEBS 3-7=0/322, 3-6=-924/76 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 13-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss M01 Truss Type MONO TRUSS Qty 6 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743401 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-mTmzTPTqIs0elZAtLTRGEBT6lG1Pbrc_WHrp7AzQUdn Scale = 1:56.7 1 2 3 4 6 5 7 8 3x4 4x6 2x4 4x6 6x6 9-11-8 9-11-8 -1-2-8 1-2-8 4-8-10 4-8-10 9-11-8 5-2-14 1-1-59-4-149-1-60-3-89-4-1410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.86 0.38 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.63 0.00 (loc) 5-6 5-6 5 l/defl >458 >184 n/a L/d 240 180 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 4-5: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS. (lb/size) 6=474/0-3-8, 5=381/0-1-8 Max Horz 6=261(LC 8) Max Uplift 6=-7(LC 9), 5=-78(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-320/73, 2-6=-311/121 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 9-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss M02 Truss Type MONO TRUSS Qty 7 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743402 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-EfKLglUS3A8VNjl4vByVnO0TCgRUKMQ7lxaMfdzQUdm Scale = 1:9.4 1 2 3 4 3x8 2x4 2x4 1-8-4 1-8-4 -1-2-8 1-2-8 1-8-4 1-8-4 0-7-41-3-111-0-30-3-81-3-115.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-1], [2:0-0-1,0-5-11], [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.11 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 2 2 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=165/0-3-8, 4=30/0-1-8 Max Horz 2=29(LC 6) Max Uplift 2=-38(LC 9), 4=-2(LC 6) Max Grav 2=165(LC 1), 4=35(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss PB01 Truss Type Piggyback Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743403 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:17 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-EfKLglUS3A8VNjl4vByVnO0TqgSnKM37lxaMfdzQUdm Scale = 1:11.7 1 2 3 4 5 6 4x6 2x4 2x42x4 5-7-10 5-7-10 2-9-13 2-9-13 5-7-10 2-9-13 0-4-71-9-10-1-80-4-70-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.05 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=121/4-1-12, 4=121/4-1-12, 6=142/4-1-12 Max Horz 2=-27(LC 7) Max Uplift 2=-20(LC 9), 4=-20(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss PB02 Truss Type Piggyback Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743404 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-isuju5U4qUGM?tKGTuUkJcYf54nO3pVH_bKwC3zQUdl Scale = 1:11.7 1 2 3 4 5 6 4x6 2x4 2x42x4 5-7-10 5-7-10 2-9-13 2-9-13 5-7-10 2-9-13 0-4-71-9-10-1-80-4-70-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.03 0.02 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 4 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=121/4-1-12, 4=121/4-1-12, 6=142/4-1-12 Max Horz 2=-27(LC 7) Max Uplift 2=-20(LC 9), 4=-20(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss PBE01 Truss Type Piggyback Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743405 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-isuju5U4qUGM?tKGTuUkJcYf54nO3pVH_bKwC3zQUdl Scale = 1:11.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 4x6 2x4 2x42x4 5-7-10 5-7-10 2-9-13 2-9-13 5-7-10 2-9-13 0-4-71-9-10-1-80-4-70-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.03 0.02 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 4 5 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=121/4-1-12, 4=121/4-1-12, 6=142/4-1-12 Max Horz 2=-27(LC 7) Max Uplift 2=-20(LC 9), 4=-20(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T01 Truss Type Common Qty 4 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743406 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-A2S65QVjbnODc0vS0c?zsp5e7UwCo4HQDF3TkVzQUdk Scale = 1:46.9 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 4x6 3x8 3x8 4x64x6 3x4 3x8 3x8 3x4 11-0-0 11-0-0 22-0-0 11-0-0 -1-2-8 1-2-8 5-7-12 5-7-12 11-0-0 5-4-4 16-4-4 5-4-4 22-0-0 5-7-12 23-2-8 1-2-8 0-10-148-2-140-10-148.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.88 0.81 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.69 0.04 (loc) 8-9 8-9 8 l/defl >960 >379 n/a L/d 240 180 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=950/0-3-8, 8=950/0-3-8 Max Horz 11=-147(LC 7) Max Uplift 11=-20(LC 9), 8=-20(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-430/45, 3-4=-854/82, 4-5=-854/82, 5-6=-430/45, 2-11=-431/92, 6-8=-431/92 BOT CHORD 9-11=0/816, 8-9=0/816 WEBS 4-9=0/577, 5-9=-260/123, 3-9=-260/123, 3-11=-680/47, 5-8=-680/46 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0, Interior(1) 14-0-0 to 23-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T02 Truss Type COMMON Qty 8 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743407 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eE0UJmWLM5W4EATfaJWCO1eptuGRXWuaRvp1GyzQUdj Scale = 1:46.8 1 2 3 4 5 6 10 9 8 7 11 12 13 14 3x4 4x6 3x8 3x8 4x64x6 3x8 3x8 3x4 11-0-0 11-0-0 22-0-0 11-0-0 5-7-12 5-7-12 11-0-0 5-4-4 16-4-4 5-4-4 22-0-0 5-7-12 23-2-8 1-2-8 0-10-148-2-140-10-148.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.78 0.88 0.85 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.27 -0.69 0.04 (loc) 7-8 7-8 7 l/defl >960 >379 n/a L/d 240 180 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=866/0-3-8, 7=952/0-3-8 Max Horz 10=-144(LC 7) Max Uplift 7=-21(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-406/30, 2-3=-860/86, 3-4=-858/82, 4-5=-431/46, 1-10=-326/45, 5-7=-431/92 BOT CHORD 8-10=0/830, 7-8=0/820 WEBS 3-8=-3/579, 4-8=-260/124, 2-8=-273/125, 2-10=-714/58, 4-7=-684/47 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-0-0, Exterior(2) 11-0-0 to 14-0-0, Interior(1) 14-0-0 to 23-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T03 Truss Type Roof Special Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743408 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eE0UJmWLM5W4EATfaJWCO1ewEuKaXcOaRvp1GyzQUdj Scale: 1/4"=1' 1 2 3 4 8 7 6 9 10 11 5 12 2x4 3x6 8x8 5x6 5x8 3x6 3x4 2-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 17-6-8 1-2-7 2-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 17-6-8 1-2-7 2-1-09-4-80-8-91-4-00-0-92-1-210.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.62 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.29 0.10 (loc) 4-6 4-6 5 l/defl >999 >724 n/a L/d 240 180 n/a PLATES MT20 Weight: 98 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x10 SP No.1 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=743/0-3-8, 5=765/0-3-8 Max Horz 8=-160(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-712/35, 1-2=-1198/65, 2-3=-822/74, 3-4=-769/53, 4-5=-346/26 BOT CHORD 6-7=-22/901, 4-6=0/546 WEBS 1-7=-9/909, 2-6=-370/117, 3-6=0/410 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 8-9-0, Exterior(2) 8-9-0 to 11-9-0, Interior(1) 11-9-0 to 17-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 8, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T04 Truss Type Piggyback Base Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743409 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-6RZsW6Xz7PexsK2r811RxEA0gHhtG0QjgZYaoOzQUdi Scale = 1:70.3 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 9 18 19 20 21 22 23 6x8 5x8 3x4 3x6 5x6 4x6 3x4 3x4 3x4 5x6 4x6 5x8 3x4 5x8 3x6 8-5-9 8-5-9 16-7-11 8-2-1 19-1-4 2-5-9 22-3-5 3-2-1 30-5-7 8-2-1 38-11-0 8-5-9 -1-2-8 1-2-8 8-5-9 8-5-9 16-7-11 8-2-1 22-3-5 5-7-10 30-5-7 8-2-1 38-11-0 8-5-9 40-1-8 1-2-8 0-10-1412-0-00-10-1412-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-3-0,0-3-4], [4:0-4-0,0-1-9], [5:0-4-0,0-1-9], [6:0-3-0,0-3-4], [7:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.65 0.55 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.26 0.03 (loc) 10-12 9-10 9 l/defl >999 >895 n/a L/d 240 180 n/a PLATES MT20 Weight: 207 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,6-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-11 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 4-13, 5-13, 6-12 REACTIONS. (lb/size) 17=717/0-3-8, 13=2044/0-3-8, 9=752/0-3-8 Max Horz 17=-220(LC 7) Max Uplift 17=-28(LC 9), 9=-28(LC 9) Max Grav 17=762(LC 13), 13=2044(LC 1), 9=792(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-793/62, 4-5=0/312, 6-7=-843/63, 2-17=-697/110, 7-9=-727/109 BOT CHORD 16-17=-141/395, 14-16=-60/553, 10-12=0/594, 9-10=-59/397 WEBS 3-16=0/362, 3-14=-734/113, 4-14=0/605, 4-13=-1076/38, 5-13=-1049/39, 5-12=0/600, 6-12=-731/112, 6-10=0/360 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=39ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 2-8-3, Interior(1) 2-8-3 to 16-7-11, Exterior(2) 16-7-11 to 27-9-6, Interior(1) 27-9-6 to 40-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T05 Truss Type Roof Special Qty 5 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743410 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ad7EkSXbuimoTUd1ikYgUSjCuh?Z?VQtvCI7LqzQUdh Scale = 1:57.1 1 2 3 4 8 7 6 9 10 11 5 12 2x4 3x6 8x8 5x6 5x8 3x6 3x49-4-82-1-21-7-22-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 18-6-8 2-2-7 2-9-10 2-9-10 8-9-0 5-11-5 16-4-1 7-7-1 18-6-8 2-2-7 2-1-09-4-89-7-60-2-150-8-90-8-150-10-92-4-110.00 12 10.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.62 0.65 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.41 0.22 (loc) 4-6 4-6 5 l/defl >999 >531 n/a L/d 240 180 n/a PLATES MT20 Weight: 103 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x10 SP No.1 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=787/0-3-8, 5=807/0-3-8 Max Horz 8=-167(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-756/20, 1-2=-1273/39, 2-3=-896/67, 3-4=-815/49, 4-5=-437/41 BOT CHORD 6-7=0/957, 4-6=0/605 WEBS 1-7=0/965, 2-6=-368/102, 3-6=0/415 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 8-9-0, Exterior(2) 8-9-0 to 11-9-0, Interior(1) 11-9-0 to 18-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 8, 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T06 Truss Type Roof Special Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743411 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-3phcxoYDe0uf5eCDFR3v0fGNN5P9kxE07s1htGzQUdg Scale = 1:62.0 1 2 3 4 8 7 6 5 9 10 11 2x4 3x6 4x6 4x6 5x6 2x4 3x6 3x8 2-9-10 2-9-10 9-9-0 6-11-6 16-6-8 6-9-8 2-9-10 2-9-10 9-9-0 6-11-6 16-6-8 6-9-8 2-1-010-2-82-5-72-1-210.00 12 10.00 12 Plate Offsets (X,Y)-- [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.64 0.43 0.62 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.17 0.05 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 8=650/0-3-8, 5=650/0-3-8 Max Horz 8=169(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-625/94, 1-2=-1084/183, 2-3=-604/83, 3-4=-593/89, 4-5=-593/80 BOT CHORD 6-7=-217/821 WEBS 1-7=-104/841, 2-6=-493/218, 3-6=0/330, 4-6=-8/311 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 16-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T07 Truss Type ROOF SPECIAL Qty 6 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743412 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-3phcxoYDe0uf5eCDFR3v0fGKc5Jcks507s1htGzQUdg Scale = 1:66.4 1 2 3 4 5 6 13 12 11 10 9 8 14 15 16 7 2x4 3x8 4x6 8x10 5x6 3x6 3x6 3x6 10x10 2x44x10 5x12 2-9-10 2-9-10 9-9-0 6-11-6 14-5-3 4-8-3 20-11-14 6-6-10 27-10-0 6-10-2 2-9-10 2-9-10 9-9-0 6-11-6 14-5-3 4-8-3 20-11-14 6-6-10 27-10-0 6-10-2 32-1-8 4-3-8 2-0-46-2-1410-1-120-8-111-1-20-3-52-1-210.00 12 3.00 12 10.00 12 Plate Offsets (X,Y)-- [5:0-5-0,0-7-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.82 0.79 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.51 -1.30 0.56 (loc) 6-8 6-8 7 l/defl >752 >294 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x10 SP No.1, 5-7: 2x10 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 *Except* 6-10: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 5-9, 4-11 REACTIONS. (lb/size) 13=1273/0-3-8, 7=1275/0-3-8 Max Horz 13=-180(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-1247/31, 1-2=-2242/79, 2-3=-1611/87, 3-4=-1572/109, 4-5=-2833/85, 5-6=-4715/81 BOT CHORD 11-12=-44/1702, 9-11=0/2732, 8-9=-19/4658, 6-8=-24/4650 WEBS 1-12=-28/1736, 2-12=0/350, 4-9=0/662, 5-9=-2030/43, 5-8=0/304, 3-11=-17/1563, 4-11=-2039/85, 2-11=-594/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 31-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 13, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T08 Truss Type Jack-Closed Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743413 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-X?F?88ZrPK1WjonQp9a8ZtoaRVj7TRC9MWnEPjzQUdf Scale = 1:31.0 1 2 3 4 5 7 6 8 9 5x12 3x4 3x63x42x4 6-11-15 6-11-15 14-0-0 7-0-1 -1-2-8 1-2-8 6-11-15 6-11-15 14-0-0 7-0-1 0-6-15-2-14.00 12 Plate Offsets (X,Y)-- [4:0-0-0,0-1-12], [4:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.49 0.45 0.38 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.17 0.02 (loc) 6-7 2-7 6 l/defl >999 >956 n/a L/d 240 180 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS. (lb/size) 6=544/Mechanical, 2=634/0-3-8 Max Horz 2=137(LC 6) Max Uplift 2=-22(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1006/30 BOT CHORD 2-7=-116/887, 6-7=-116/887 WEBS 3-7=0/322, 3-6=-924/76 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 13-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T09 Truss Type Half Hip Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743414 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?CpNMUaTAd9NKxMcNs6N54Ln?v0QCuqJbAWnx9zQUde Scale = 1:26.5 1 2 3 4 5 7 6 8 9 10 11 4x6 2x44x6 2x4 3x12 3x4 10-3-8 10-3-8 14-0-0 3-8-8 -1-2-8 1-2-8 5-3-7 5-3-7 10-3-8 5-0-1 14-0-0 3-8-8 0-6-13-9-73-11-33-9-74.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.70 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.68 0.02 (loc) 2-7 2-7 6 l/defl >627 >244 n/a L/d 240 180 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-15 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 6=544/Mechanical, 2=634/0-3-8 Max Horz 2=100(LC 8) Max Uplift 6=-2(LC 6), 2=-24(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1001/92, 3-4=-551/31, 4-5=-480/42, 5-6=-551/74 BOT CHORD 2-7=-212/906 WEBS 3-7=-460/147, 5-7=-62/651 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 10-3-8, Exterior(2) 10-3-8 to 13-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T10 Truss Type Roof Special Qty 3 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743415 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?CpNMUaTAd9NKxMcNs6N54Ll2v5?CqwJbAWnx9zQUde Scale = 1:65.0 1 2 3 4 5 6 13 12 11 10 9 8 7 14 15 16 2x4 3x6 4x6 3x6 2x4 5x6 3x6 2x4 3x6 4x8 6x8 6x8 3x6 2-9-10 2-9-10 9-9-0 6-11-6 12-3-0 2-6-0 15-10-12 3-7-12 19-10-0 3-11-4 2-9-10 2-9-10 9-9-0 6-11-6 12-3-0 2-6-0 15-10-12 3-7-12 19-10-0 3-11-4 2-1-010-2-811-2-82-9-101-0-03-1-23-1-210.00 12 10.00 12 Plate Offsets (X,Y)-- [10:0-6-0,0-3-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.35 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.04 (loc) 11-12 11-12 7 l/defl >999 >816 n/a L/d 240 180 n/a PLATES MT20 Weight: 107 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 13=451/0-3-8, 7=226/0-3-8, 10=887/0-3-8 Max Horz 13=203(LC 8) Max Uplift 13=-3(LC 9), 7=-13(LC 9) Max Grav 13=451(LC 1), 7=238(LC 14), 10=887(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-427/30, 1-2=-751/76, 2-3=-279/81, 5-6=-268/4 BOT CHORD 12-13=-259/232, 11-12=-177/567, 4-10=-696/49 WEBS 1-12=-24/587, 2-11=-483/170, 4-11=0/439, 5-10=-275/81 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-1-12 to 2-11-6, Interior(1) 2-11-6 to 9-9-0, Exterior(2) 9-9-0 to 12-9-0, Interior(1) 12-9-0 to 19-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 13, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 7. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T11 Truss Type Roof Special Qty 2 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743416 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-TONlZqb6xxHDy5xoxadceIuxjIOpxMtSqqGLUbzQUdd Scale = 1:67.9 1 2 3 4 5 6 9 8 7 10 11 12 13 4x6 3x4 3x8 2x4 3x4 3x4 5x6 5-4-15 5-4-15 7-5-8 2-0-9 7-7-4 0-1-12 15-3-4 7-8-0 -1-2-8 1-2-8 5-4-15 5-4-15 10-2-6 4-9-6 15-3-4 5-0-14 17-3-4 2-0-0 0-7-42-10-512-8-1410-9-60-3-812-8-145.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-0-1,0-5-11], [2:0-0-0,0-0-1], [5:0-0-11,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.56 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.26 -0.00 (loc) 7-8 7-8 7 l/defl >859 >360 n/a L/d 240 180 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-7: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-7 REACTIONS. (lb/size) 2=348/0-3-8, 8=708/0-3-8, 7=470/0-1-8 Max Horz 2=349(LC 6) Max Uplift 2=-8(LC 5), 7=-206(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-290/49, 3-4=-264/125, 4-5=-252/91, 5-7=-277/200 WEBS 3-8=-253/53 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 17-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 7=206. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss T12 Truss Type Roof Special Qty 3 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743417 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-xax7nAbkiFP4aFW?UH8rAVQ5Liougr4c2U?u02zQUdc Scale = 1:59.1 1 2 3 4 7 6 5 8 9 3x6 3x8 2x4 4x8 2x4 5x6 5-4-15 5-4-15 7-5-8 2-0-9 7-7-4 0-1-12 13-11-12 6-4-8 -1-2-8 1-2-8 5-4-15 5-4-15 13-11-12 8-6-13 0-7-42-10-510-0-09-8-80-3-810-0-05.00 12 10.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-1], [2:0-0-1,0-5-11], [2:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.45 0.32 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.11 0.00 (loc) 5-6 5-6 6 l/defl >999 >681 n/a L/d 240 180 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-7,3-6: 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS. (lb/size) 2=408/0-3-8, 6=493/0-3-8, 5=275/0-1-8 Max Horz 2=269(LC 8) Max Uplift 2=-13(LC 9), 5=-80(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-404/42 BOT CHORD 2-7=-148/312, 6-7=-149/309 WEBS 3-6=-514/87 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 13-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss TG01 Truss Type GABLE Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743418 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-qMAecXeEmTvW2spmj7CnLLbnYJ3OcUnBz6z69pzQUdY Scale = 1:77.2Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 971 72 73 74 75 76 77 78 79 5x8 5x8 8x8 8x8 5x6 6x6 4x8 4x6 4x6 5x6 4x6 8x8 3x4 3x4 3x4 3x4 3x4 8x8 Special Special Special Special Special Special Special Special 8-5-9 8-5-9 16-7-11 8-2-1 19-1-4 2-5-9 22-3-5 3-2-1 30-5-7 8-2-1 38-11-0 8-5-9 -1-2-8 1-2-8 8-5-9 8-5-9 16-7-11 8-2-1 22-3-5 5-7-10 30-5-7 8-2-1 38-11-0 8-5-9 40-1-8 1-2-8 0-10-1412-0-00-10-1412-0-08.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-3-0], [4:0-6-4,0-2-4], [5:0-6-4,0-2-4], [6:0-2-12,0-3-0], [9:0-2-5,0-1-8], [9:0-3-8,0-2-12], [11:0-4-0,0-4-8], [14:0-3-8,0-2-0], [15:0-0-0,0-2-12], [16:0-3-0,0-3-12], [17:0-2-12,0-0-0], [17:0-4-0,0-7-0], [30:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.43 0.67 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.29 0.02 (loc) 14-16 14-16 9 l/defl >999 >796 n/a L/d 240 180 n/a PLATES MT20 Weight: 1353 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E *Except* 11-15: 2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-16,6-10,2-16,7-10: 2x4 SPF-S Stud, 2-17,7-9: 2x6 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 21-22,26-27,50-51: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 4-13 REACTIONS. (lb/size) 17=2666/0-3-8, 13=4530/0-3-8 (req. 0-3-9), 9=536/0-3-8 Max Horz 17=-220(LC 15) Max Uplift 9=-100(LC 17) Max Grav 17=2705(LC 11), 13=4530(LC 1), 9=572(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2986/0, 3-4=-294/75, 4-5=0/641, 5-6=0/557, 6-7=-490/155, 2-17=-1981/0, 7-9=-515/143 BOT CHORD 16-17=-113/1479, 14-16=0/2386, 12-13=-382/73, 10-12=-24/301, 9-10=-39/376 WEBS 3-16=0/2650, 3-14=-2818/0, 4-14=0/3104, 4-13=-3517/0, 5-13=-1083/0, 5-12=0/433, 6-12=-765/75, 6-10=0/389, 2-16=0/897 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=39ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) WARNING: Required bearing size at joint(s) 13 greater than input bearing size. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. Continued on page 2 April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss TG01 Truss Type GABLE Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743418 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:31 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-qMAecXeEmTvW2spmj7CnLLbnYJ3OcUnBz6z69pzQUdY NOTES- 13) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 552 lb down and 62 lb up at 2-3-4, 524 lb down and 14 lb up at 4-7-4, 524 lb down at 6-7-4, 524 lb down at 8-5-8, 524 lb down at 10-5-8, 524 lb down at 12-5-8, and 524 lb down at 14-5-8, and 524 lb down at 16-5-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 5-7=-60, 7-8=-60, 16-17=-20, 16-75=-60, 75-79=-20, 10-79=-60, 9-10=-20 Concentrated Loads (lb) Vert: 16=-524(F) 71=-552(F) 72=-524(F) 73=-524(F) 74=-524(F) 76=-524(F) 77=-524(F) 78=-524(F) 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss TG02 Truss Type Half Hip Girder Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743419 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-qMAecXeEmTvW2spmj7CnLLbegJ8hca9Bz6z69pzQUdY Scale = 1:25.5 1 2 3 4 6 5 7 8 9 10 11 12 13 14 4x10 3x8 4x63x6 2x4 Special Special Special Special Special Special Special Special Special 5-7-8 5-7-8 14-0-0 8-4-8 -1-2-8 1-2-8 5-7-8 5-7-8 14-0-0 8-4-8 0-6-12-4-94.00 12 Plate Offsets (X,Y)-- [3:0-5-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 1.00 0.33 0.50 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.13 0.02 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-3 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 3-5 REACTIONS. (lb/size) 5=572/Mechanical, 2=680/0-3-8 Max Horz 2=59(LC 4) Max Uplift 5=-50(LC 4), 2=-48(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1223/72, 4-5=-250/80 BOT CHORD 2-6=-84/1100, 5-6=-79/1116 WEBS 3-6=0/349, 3-5=-1008/40 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 40 lb down and 27 lb up at 6-0-12, 43 lb down and 27 lb up at 8-0-12, and 43 lb down and 27 lb up at 10-0-12, and 43 lb down and 27 lb up at 12-0-12 on top chord, and 86 lb down and 32 lb up at 5-7-8, 4 lb down and 3 lb up at 6-0-12, 4 lb down and 3 lb up at 8-0-12, and 4 lb down and 3 lb up at 10-0-12, and 4 lb down and 3 lb up at 12-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 6=-83(B) 12=3(B) 13=3(B) 14=3(B) April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743420 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IYk0qtfsXn1Ng0OyHqk0tZ7xtjMJLw8LCmjfhFzQUdX Scale = 1:74.0 1 2 3 4 5 6 7 8 15 14 13 12 11 10 916 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 5x8 5x8 5x8 3x4 3x4 4x8 5x6 3x12 4x6 4x6 4x6 5x6 3x12 5x8 3x4 3x4 4x8 8-5-9 8-5-9 16-7-11 8-2-1 19-1-4 2-5-9 22-3-5 3-2-1 30-5-7 8-2-1 38-11-0 8-5-9 8-5-9 8-5-9 16-7-11 8-2-1 22-3-5 5-7-10 30-5-7 8-2-1 38-11-0 8-5-9 0-10-1412-0-00-10-1412-0-08.00 12 Plate Offsets (X,Y)-- [1:0-4-15,0-1-4], [3:0-3-0,0-3-0], [4:0-6-4,0-2-4], [5:0-6-4,0-2-4], [6:0-3-0,0-3-0], [8:0-4-15,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.46 0.88 0.96 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.27 0.04 (loc) 1-15 1-15 8 l/defl >999 >844 n/a L/d 240 180 n/a PLATES MT20 Weight: 436 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-15,6-9: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 5-0-10, Right 2x4 SPF-S Stud 5-0-10 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (10-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 5-12 REACTIONS. (lb/size) 1=2184/0-3-8, 12=6424/0-3-8 (req. 0-5-1), 8=2065/0-3-8 Max Horz 1=-197(LC 5) Max Grav 1=2185(LC 11), 12=6424(LC 1), 8=2065(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2199/0, 3-4=0/402, 4-5=0/837, 5-6=-62/323, 6-8=-2356/0 BOT CHORD 1-15=0/1716, 13-15=0/1727, 12-13=-268/42, 9-11=0/1853, 8-9=0/1842 WEBS 3-15=0/2235, 3-13=-2424/0, 4-13=0/2378, 4-12=-3007/0, 5-12=-3047/0, 5-11=0/2484, 6-11=-2387/0, 6-9=0/2205 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=39ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) WARNING: Required bearing size at joint(s) 12 greater than input bearing size. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-8=-60, 1-18=-20, 18-22=-60, 22-28=-20, 28-32=-60, 8-32=-20 Continued on page 2 April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss TG03 Truss Type Piggyback Base Girder Qty 1 Ply 2 JACKSON'S GRANT 69 Job Reference (optional) I36743420 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:32 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IYk0qtfsXn1Ng0OyHqk0tZ7xtjMJLw8LCmjfhFzQUdX LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 13=-370 12=-370 10=-370 16=-371 17=-370 18=-370 19=-370 20=-370 21=-370 23=-370 24=-370 25=-370 26=-370 27=-370 29=-370 30=-370 31=-370 33=-370 34=-370 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V01 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743421 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-mkIO1DgVI59EIAz8rYFFQmg9u7ts4WmURQSDEhzQUdW Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 3x4 4x6 3x4 3x4 3x4 3x4 31-4-6 31-4-6 31-4-12 0-0-6 15-8-6 15-8-6 31-4-12 15-8-6 0-0-410-5-90-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.32 0.15 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-4,8-11: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 6-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS. All bearings 31-4-0. (lb) - Max Horz 1=-168(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 18, 19, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=415(LC 1), 17=510(LC 13), 18=399(LC 1), 19=310(LC 13), 14=510(LC 14), 13=399(LC 1), 12=310(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-258/107, 7-14=-258/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=31ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-8-6, Interior(1) 3-8-6 to 15-8-6, Exterior(2) 15-8-6 to 18-10-0, Interior(1) 18-10-0 to 30-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 18, 19, 14, 13, 12. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V02 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743422 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ExsnFZh73OH5vKYLPFmUz_DKMXDbp?Pef4Cmm8zQUdV Scale = 1:55.8 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 3x4 4x6 3x4 3x4 26-4-6 26-4-6 26-4-12 0-0-6 13-2-6 13-2-6 26-4-12 13-2-6 0-0-48-9-90-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.27 0.19 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 4-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11 REACTIONS. All bearings 26-4-0. (lb) - Max Horz 1=-136(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 11=426(LC 1), 12=480(LC 13), 13=441(LC 1), 9=480(LC 14), 8=441(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-291/118, 6-8=-291/118 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=26ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 13-2-6, Exterior(2) 13-2-6 to 16-2-6, Interior(1) 16-2-6 to 25-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V03 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743423 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-i7Q9SvilqiPyXU7XyzHjVBlSwwSEYT3nukxJIazQUdU Scale = 1:47.4 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-6 0-0-6 21-4-12 21-4-6 10-8-6 10-8-6 21-4-12 10-8-6 0-0-47-1-90-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.47 0.61 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 65 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 21-4-0. (lb) - Max Horz 1=109(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=332(LC 1), 9=598(LC 13), 6=597(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-382/149, 4-6=-386/150 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 10-8-6, Exterior(2) 10-8-6 to 13-8-6, Interior(1) 13-8-6 to 20-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V04 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743424 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-i7Q9SvilqiPyXU7XyzHjVBlXbwZnYU9nukxJIazQUdU Scale = 1:34.9 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 0-0-6 0-0-6 16-4-12 16-4-6 8-2-6 8-2-6 16-4-12 8-2-6 0-0-45-5-90-0-48.00 12 Plate Offsets (X,Y)-- [7:0-0-0,0-1-12], [7:0-3-0,0-1-4], [8:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.19 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 16-4-0. (lb) - Max Horz 1=-82(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=366(LC 13), 6=366(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-274/112, 4-6=-276/112 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 8-2-6, Exterior(2) 8-2-6 to 11-2-6, Interior(1) 11-2-6 to 15-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V05 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743425 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-AJzXgEiNb0Xp9eijWgoy2PIdxKtEHxcw7Ohtq0zQUdT Scale = 1:24.7 1 2 3 4 5 6 7 8 3x6 4x6 3x62x4 0-0-6 0-0-6 11-4-12 11-4-6 5-8-6 5-8-6 11-4-12 5-8-6 0-0-43-9-90-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.46 0.30 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=205/11-4-0, 3=205/11-4-0, 4=424/11-4-0 Max Horz 1=-55(LC 7) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-264/59 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 5-8-6, Exterior(2) 5-8-6 to 8-8-6, Interior(1) 8-8-6 to 10-10-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V06 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743426 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-AJzXgEiNb0Xp9eijWgoy2PIh9KnkHy7w7Ohtq0zQUdT Scale = 1:15.6 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 6-4-12 6-4-6 3-2-6 3-2-6 6-4-12 3-2-6 0-0-42-1-90-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.25 0.66 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=217/6-4-0, 3=217/6-4-0 Max Horz 1=29(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V08 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743427 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eWXvtaj?LJfgmnHw4OJBacrmuk9Y0PN4L2QQNSzQUdS Scale = 1:18.2 1 2 3 4 5 3x6 3x8 3x4 10-1-7 10-1-7 0-0-43-4-84.00 12 Plate Offsets (X,Y)-- [2:0-3-14,Edge], [3:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.64 0.49 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=361/10-1-7, 3=361/10-1-7 Max Horz 1=84(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-11-5 to 3-11-5, Interior(1) 3-11-5 to 9-11-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19901554 Truss V09 Truss Type Valley Qty 1 Ply 1 JACKSON'S GRANT 69 Job Reference (optional) I36743428 8.220 s Nov 16 2018 MiTek Industries, Inc. Mon Apr 15 11:17:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eWXvtaj?LJfgmnHw4OJBacriVk8g0PN4L2QQNSzQUdS Scale = 1:14.0 1 2 3 4 5 2x4 2x4 2x4 6-1-7 6-1-7 0-0-42-0-84.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.85 0.55 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=201/6-1-7, 3=201/6-1-7 Max Horz 1=47(LC 6) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-11-5 to 3-11-5, Interior(1) 3-11-5 to 5-11-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 15,2019 04/17/19 William Hohlt PRODUCT CODE APPROVALS LATERAL BRACING LOCATION Indicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the platewidth measured perpendicularto slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside" 16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS.W4 - 6 W3-6W3 -7 W2-7W1-7C1-8 C5-6C6-7C7-8 C4-5 C3-4C2-3C1-2 TOP CHORD TOP CHORD 8 7 6 54321 BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates therequired direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1" 4/3PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes* Plate location details available in MiTek 20/20 software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8 WEBS Trusses are designed for wind loads in the plane of thetruss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1section 6.3 These truss designs rely on lumber valuesestablished by others.dimensions shown in ft-in-sixteenths 04/17/19 William Hohlt