HomeMy WebLinkAboutCLAY CORNER 33 - CC033 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 33
CC033 (AS DESIGNED)
CLAY CORNER 33
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S935
5142
5390
$1,466
5571
50
$2,037
Requirements
C-M,
Energy Solutions
As designed
S788
S122
S390
$1,300
S571
SO
$1,870
C4405.3 Performance-based compliance passes by 11.4%
402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 11.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
3114/19 at 9:04 AM
Ekotrope RATER - Version 3.1.0.2131
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
AUri Pi
1567 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 126.0 CFM @ 25Pa
Total Duct Leakage 168.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 3114119 at 9:04 AM
Ekotrope RATER - Version 3.1.0.2131
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1567 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL(B)
Community: CLAY CORNER 33 Builder
LENNAR HOMES
CC033 (AS DESIGNED)
CLAY CORNER 33
General Building Information
Conditioned Area (sq ft) 2,105
Conditioned Volume (cubic ft) 18,945
Insulated Shell Area (sq ft) 6,118
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,195 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (1,728 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
None Present
Roof
Energy Code Inspection Checklist
Property Organization
1567 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL(B)
Community: CLAY CORNER 33 Builder
LENNAR HOMES
CC033 (AS DESIGNED)
CLAY CORNER 33
Name: SECOND (2,105 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
inspection Status
Results are projected
E] Name: FRONT (72 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
E] Name: BACK (54 s.f.), U:0.310, SHGC: 0.32, Orientation: EAST
El Name: LEFT SIDE (54 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
El Name: LEFT SIDE GD (18 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
El Name: RIGHT SIDE (56 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
M Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 33
CC033 (AS DESIGNED)
CLAY CORNER 33
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,895 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 126.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 168.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
3
Project Notes
Building Summary
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 33
CC033 [AS DESIGNED]
CLAY CORNER 33
Genera?Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Model
Community
Climate Zone
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
4
1
2;105
Yes
18;945
1
Single family detached
CHARTWELL(B)
CLAY CORNER 33
5A
Basement Wall
None Present
Basement Wall Library List
None Present
Slab
C-M,
Energy Solutions
1P
Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 2'down
212 On Grade
0
0 2,105.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library List "s
w
1qr
Name Wall Construction Type
Slap Completely Underslalb
Insulation
Perimeter Insulation Perfineterinsufation R
R -value
Insulated.
Width [ft]
Depth [Pt] Value
IR-10, 2'down Wood Frame / Other
No
0
2 1 D
0.00
Framed Floor Im
None Present
1
Building Summary
Property
Organization
1567 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL[B]
Wall Library List
Community: CLAY CORNER 33
Builder
LENNAR HOMES
CC033 [AS DESIGNED]
CLAY CORNER 33
Framed Floor Library
Rim Joist
Rim Joist Library List _
None Present
Name
Library Type
CONDIAMB 2X4 G1 R-13 BATT, R-3.0
CONDIGAR
G1 R-13 Gar Walls
Wall Library List
—Am
Name
G1 R-13 BATT, R-3.0
G1 R-13 Gar Walls
Glazing
Name Lit1rary Type
Wall Assignment
BACK 11-.31, SHGG.32
CONDIAMB 2X4
FRONT 111-.31, SHGG29
CONDIAMB 2X4
1512 1512
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Calor Surface Area Location
Medium 1.728.0 sq. fl. Exposed Exterior
Medium 180.0 sq. fl. Unconditioned, attached garage
❑ 0 ❑ East 54.0 sq. tt
❑ 0 0 West 72.0 sq. fl -
Building Summary
Property Organization
Inspection Status
C-MEnergy
Solutions
1567 JENSEN DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL[B]
Community: CLAY CORNER 33 Builder
LENNAR HOMES
CC033 [AS DESIGNED]
CLAY CORNER 33
Name Library type Wall Assignment Basement Wall Overhang Depth Overhang Ft To
Overhan Ft To
Orientation
Surface Area
Assignment
Top
Bottom
LEFT SIDE U-.31, SHGC-.32 CONDIAMB 2X4
0 0
0
North
54.0 sq. tt
LEFT SIDE GD U-.31, SHGG.32 CONDIAMB 2X4
0 0
0
North
18.0 sq. R
RIGHT SIDE U-.31, SHGG.32 CONDIAMB 2X4
0 0
0
South
56.0 sq. fl -
Glazing
Glazing LibraryList
Name Shg c U -factor
U-.31, SHGC-29 0.29 0.310
U-.31, SHGC-.32 0.32 0.310
T
Skylight
None Present
Skylight Library List
Opaque Door
Name Library Type Wall Assignment Basement Wall
Assign ment
FRONT Steel Door CONDIAMB 2704
GARAGE Steel Door CONDIGAR
Opaque Door Library List
Name U -factor
Steel Door 0.182
Emlttance Solar Surface Color Surface Area Location
Absorptance
0.9 0.75 Medium 24.0 sq_ ft Exposed Exterior
0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior
9
Building Summary
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 33
CC033 [AS DESIGNED]
CLAY CORNER 33
Roof Insulation
Name
Library Typ
SECOND
R-38 Blown. GR1
Roof Insulation Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
irea Gtay or ConCrete Root
P.f.] 'riles
2,105 No
Name Has Radiant Barrier
IR-38 Blown, GR1 No
Whale House Infiltration
Infiltration Measurement Type
6 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
38265
4
C-M,
Energy Solutions
it
Medium 2,105.0 sq. ft Attic
■
Lighting
°I Interior Fluorescent °I Interior LED Lighting °I Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent °I Garage LED Lighting
Lighting Lighting Lighting
0 100 0 100 C 100
Onsite Generation
None Present
4
Building Summary
Property
Organization
1567 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL(B)
92.1 AFUE
Community: CLAY CORNER 33
Builder
Use default EAE
LENNAR HOMES
CC033 [AS DESIGNED]
1,247
CLAY CORNER 33
Onsite Generation Library List
None
Solar Generation
Solar Generation Library List
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
Air conditioner CA13NA060 0% 1001 0%
Fuel4red air 9125A6012OS24 100% 0% 0%
distribution
Water Heating RE350" 0% 0% 100%
Equipment Type: 912SA6012OS24
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
112
Use default EAE
No
EAE [kWh]
1,247
E uipment Type: CA13NA060
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
mm
Electric
Forced Air
PSC (Single Speed)
13 SEER
58.2
:j
Building Summary
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 33
CC033 [AS DESIGNED]
CLAY CORNER 33
Equipment Type:
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
RE350*
Distribution System
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Electric
Hydronic Delivery
0.93 Energy Factor
5❑
15.4
❑.98
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
2105
# Return Grilles
3
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
568.35
Return Duct Area [sq. ft_]
315.75
Duct Leakage to Outdoors (CFM25)
126
Total Leakage
168
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
'-Ceiling Fan ��Ml
Has Ceiling Fan No
Cfm Per Watt 100
C-M,
Energy Solutions
Al
Building Summary
Property
1567 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 33
CC033 [AS DESIGNED]
CLAY CORNER 33
Water Distribution MM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
75
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
7