HomeMy WebLinkAboutA115 5th Floor Architectural Floor PlanARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN WALL WALL W? ® PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL oo WINDOW/SIDELIGHT WINDOW/SIDELIGHT ®DOOR AND FRAME DOOR SCHEDULE) DOOR AND FRAME (SEE NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOUTION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BEWI UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALLTYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. Wt WALL WITH INSULATION " 3S/p" METAL STUDS AT I6"O.C.; T,� 1 ONE LAYEROFS/e"TYPE"X"GYP SUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF CEILING; FIBERGLASS SOUND BAITINSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING ❑W2 PARTIAL HEIGHT WALL 35/8 " METAL STUDS AT 16" O.C.; ONE LAYER OFS%'TYPI GYPSUM BOARD EACH SIDE; EMEND WALLAS NOTED. PROVIDE I"STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; REFER TO ELEVATIONS FOR HEIGHT AT COUNTER/BAR LOCATION. PROVIDE WALL TO 42A.F.F WITH _ TOP CAP AT BOOTH SEATING. ❑w WALL TO DECK WITH INSULATION 3% METAL STUDS AT 16" O.C.; ONE LAYER OF %' TYPE "X" GYPSUM BOARD EACH SIDE; EMEND WALL TO UNDERSIDE OF DECK; MINERAL WOOL SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULA➢ON EACH SIDE OF WALL ABOVE CEIUNG. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 05/07/19 t AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED. IF NOT, PROVIDE NEW INSULATION AS REQUIRED. 3. PROVIDE SEPARATE PRICE FOR SOUND-PROOFINGAT EXISTING MULLIONS. PLAN NOTES NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR IN FILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET A02 TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PROVIDE COAT ROD AND SHELF AT THIS LOCATION; SEE DETAIL A03 2/A215 FOR MORE DETAILS. PROVIDE (2) BRUSHED CHROME DOUBLE COAT HOOKS AT MAXIMUM 48" A.F.F. FOR ADA COMPLIANCE AT THIS LOCATION. A04 PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S A05 FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AN D DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL, COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. AD6 PROVIDE SEPARATE PRICE FOR WORK IN THIS AREA, AO] CONTRACTOR/ TENANT TO CONFIRM EXACT BOOTH DIMENSIONS WITH FURNITURE VENDOR/TABLE TOP SIZE. qpg CONTRACTOR TO CONFIRM EXISTING FIRE EXTINGUISHER IS IN WORKING CONDITION. POI PROVIDE POTABLE HOT AN, D COLD WATER AND SANITARY WASTE JT WATER AND XISTING POLYTUBE TO BE ATION WITH TENANT. J DRAINS FOR TENANT AT THIS LOCATION. 5TH FLOOR ARCHITECTURAL PLAN 0 4' 8' 16, I�N THIS DRAWING. AND THE IDEAS. IESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR CONSENT OF SCHOTT DESIGN. N i ) J%0 CL W Z Q LLJ o 0 LU Q 0 Li j Y O V�� ZLLJ �S ZoL Q Z aaa� 11 L�� LL. ISSUE DATE DESCRIPTION 09.26.18 REVIEW SEI 10.12.18 UPDATED SET 10.17.18 PERMIT SET 11.28.18 REVISED SET 11.30.18 REDUCED SCOPE EVISONS ARK DATE DB DESCRIPTION ® 0.2578 GRB REV.1 .05.19 CRB IJPDATED P.SET Now tttttlllllln/J� No. AR10700017 , STATE OF n7nnniro Iiiiiiim PROJECT NUMBER 2018.263 PROD. MGR DRAWN BY AS CRB/ JJ iiiiiiim 5TH FLOOR ARCHITECTURAL FLOOR PLAN Al 15