HomeMy WebLinkAboutD116 6th Floor Demolition PlanLEGEND
EXISTING TO BE REMOVED
WALL
m===== PARTIAL HEIGHT WALL
i DOOR AND FRAME
WINDOW / SIDELIGHT
AI ----- L CEILING GRID AND
TILES, 2'x4'
--L--� CEILING GRID AND
7--T--r TILES, 2'X2'
F'T
T `<T SUPPLY AIR DIFFUSERS
cv sa
LIGHT FIXTURE,
FLUORESCENT, 2'X4'
LIGHT FIXTURE,
LaJ
FLUORESCENT, 2'x2'
jj
LIGHT FIXTURE, CAN
Tk
LIGHT FIXTURE, SCOT
LIGHT FIXTURE,
PENDANT
$
LIGHT SWITCH
i^y
EXIT LIGHT
'�_g; ELECTRICOUTLETjS
T 9)TO)(JD'
DATA OR
DO COMMUNICATION
OUTLET
EXISTING TO REMAIN
WALL
PARTIAL HEIGHT WALL
DOOR AND FRAME
x WINDOW/SIDELIGHT
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
PLAN NOTES
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
D01 REMOVE EXISTING CABINETRY AND COUNTERTOP.
002 REMOVE EXISTING SINK, NO SERVICE SINKS ARE BEING REMOVED
OREMOVE EXISTING RECEPTACLE, DATA, BOX AND/OR SWITCH AS
D03 SHOWN. PATCH WALL AND PREPARE FOR NEW FINISHES AS
REQUIRED.
D04 REMOVE EXISTING DRYWALL CEILING AND BULKHEAD. SEE
REFLECTED CEILING PLAN FOR MORE INFO.
DOS RELOCATE EXISTING CABLE BOX ON WALL ABOVE CEILING, PATCH
WALL AND PREPARE FOR NEW FINISHES,
REMOVE EXISTING PHONE BOARD FROM THIS LOCATION. PATCH
DO6 WALL AND PREPARE FOR NEW FINISHES AS REQUIRED.
REMOVE EXISTING TILE FLOOR AND PREPARE FOR NEW FINISHES AS
D07 REQUIRED. SEE FINISH PLAN FOR MORE DETAILS.
DOB REMOVE EXISTING COUNTERTOP AND SINK. PLUMBING
LOCATIONS TO REMAIN. SALVAGE MIRROR FOR REUSE.
D09 REMOVE TOILET PARTITIONS AND ALL FINISHES; SEE AI4I FOR NEW
RESTROOM INFORMATION. TOILETS AND URINALS TO REMAIN.
CONTRACTOR TO CONFIRM FIXTURES ARE IN WORKING
CONDITION,
D10 EXISTING MOBILE PARTITION WALL TO REMAIN,
OEXISTING CASEWORK AND/OR COUNTER TO REMAIN. REFER TO
D11 FINISH PLAN FOR MORE INFORMATION,
OREMOVE EXISTING CEILING GRID AND LIGHT FIXTURES. SEE
D12 REELECTED CEILING PLAN FOR MORE INFORMATION.
REMOVE EXISTING TOILET PARTITIONS AND LIGHT FIXTURES. ALL
D13 OTHER BATHROOM PLUMBING FIXTURES AND ACCESSORIES TO
REMAIN UNLESS NOTED OTHERWISE. CONTRACTOR TO CONFIRM
PLUMBING FIXTURES ARE IN GOOD WORKING CONDITION. SEE
A 141 FOR NEW RESTROOM INFORMATION. PROVIDE SEPARATE
PRICE TO REMOVE ALL WALL TILE.
D74 REMOVE EXISTING PARTIAL HEIGHT MILLWORK WALL. PATCH WALL
AS REQUIRED FOR NEW FINISHES,
D15 EXISTING PARTIAL HEIGHT WALL/PLANTER TO REMAIN.
OEXISTING ROTUNDA ELEMENTS INCLUDING CEILING, LIGHTING,
D18 AND WOOD FLOOR TO REMAIN,
D17 EXISTING CHAIR RAIL AND/OR WALL PANELING TO REMAIN ON
EXISTING WALLS. SEE FINISH PLANS FOR MORE INFORMATION.
D18 REMOVE EXISTING ARCHITECTURAL CORNICE, PATCH WALL AS
REQUIRED.
D19 REMOVE EXISTING BOOTH SEATING.
D20 EXISTING WOOD FLOOR TO REMAIN.
CONFIRM STYLE OF EXISTING LIGHT FIXTURES IN THIS AREA. IF
D21 PRISMATIC LENSES, EXISTING FIXTURES TO REMAIN. IF PARABOLIC
LENSES, REMOVE AND PROVIDE NEW PRISMATIC LIGHT FIXTURES
PER NEW OPEN OFFICE LAYOUT,
OEXISTING FRONT WOOD PANELING AND TRANSACTION TOP TO
D22 REMAIN.
I'll 1"111 """""^OM.SEEFINISH PLAN FOR
RELEASED FOR CONSTRUCTION
Subject to compliance aRh all regulations
of State and Local Codes
City of Camel
�VT�'�8a�41WML
DATE: \ 05/07/19
FINISH PLAN FOR MORE
® AREA NOT IN CONTRACT 6TH FLOOR DEMOLITION PLAN
AREA OF WORK 0 4
❑ mm"%mmmIi
E
O
N d O V
O
in Z
p 0 M n 46
O LJ O
w O M
O C
C
I
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE W R17EN
CONSENT OF SCHCTT DESIGN.
CV
co
C)
JCS
C _y z
O uJ
LO
0�L�
a
O,nNU
LL J YRe
O
V��
ZILILJ
Z:5
Q � Z
ZLLI
��
LI
ISSUE
DATE
DESCRIPTION
09.26.18
REVIEW SET
10.12.18
UPDATED SET
10.17.18
PERMIT SET
11.28.18
REVISED SET
11.30.18
REDUCED SCOPE
EVISONS
MARK I
DATE
I DB
IDESCRIPTION
026,18
CRB
REV.1
®
4.06.19
CRB
PDATED P.SET
AR10700017
STATE OF
PROJECT NUMBER
2018.263
PROD. MGR DRAWN BY
AS CRB/ JJ
6TH FLOOR
DEMOLITION PLAN
D116