HomeMy WebLinkAboutE116 6th Floor Electrical Plan11101VL7
NEW CONSTRUCTION EXISTING TO REMAIN
n*N
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
=ON
FF
POWER OUTLET,
POWER OUTLET,
QUADRUPLEX
QUADRUPLEX
®
JUNCTION BOX
QJ
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
®
BOX, OPEN
QO
BOX, OPEN
POWER POLE FOR
P
POWER AND DATA POLE
a
ELECTRICAL AND DATA.
D
PROVIDE JUNCTION BOX
ABOVE CEILING.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
�I®
AND DATA, FLUSH
&b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
�b
JUNCTION BOX AND
J b
JUNCTION BOX AND
N
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
KIN
OUTLET (PROVIDE BOX
b
OUTLET
AND PULL STRING ONI
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�SJ'�B*�41WMt_
DATE: \ 05/07/19
t
AREA NOT IN CONTRACT
AREA OF WORK
GENERAL NOTES
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
PLAN NOTES
E01 NOT USED,
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
E02 DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE JUNCTION BOX AN D DATA FOR TENANT'S FURNITURE
E03 SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
60" A.F.F.
E05 PROVIDE POWERAND DATA AT60" A.F.F. FORTENANTSWALL
MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH
TENANT.
E06 PROVIDE POWER FORTENANTS VENDING MACHINES. CONFIRM
WITH TENANT AND VENDING PROVIDER ON EXACT POWER
REQUIREMENTS,
E07 PROVIDE POWER AND USB COMBO AT 32" AE.F ABOVE BOOTH
TABLE FOR CHARGING.
E08 PROVIDE POWER AT THIS LOCATION FOR TENANT'S DISHWASHER
AND/OR GARBAGE DISPOSAL.
E09 PROVIDE POWER AT THIS LOCATION FOR TENANTS ICE MACHINE
AS REQUIRED.
E70 PROVIDE BRASS PLATE FLUSH MOUNT FLOOR CORE WITH POKE
THRU DEVICE FOR ELECTRICAL AND DATA WITH CONDUIT
CONNECTION TO WALL MOUNTED W. COORDINATE WITH
TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE
POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR
TO ORDERING.
Ell IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW
RECEPTACLE AS SHOWN. IF NOT POSSIBLE, REMOVE BLANK/OPEN
BOX AND PROVIDE NEW RECEPTACLE AT THIS LOCATION.
E12 NO ELECTRICAL WORK IN THIS ROOM UNLESS OTHERWISE NOTED,
E13 RELOCATE EXISTING CABLE BOX ON WALL ABOVE CEILING.
E74 ALL ABOVE COUNTER OUTLETS ARE FOR DEDICATED APPLIANCE
USE ONLY. CONVENIENCE OUTLETS ARE LOCATED ELSEWHERE IN
ROOM.
E15 CONTRACTOR TO CONFIRM ALL EXISTING POWER TO REMAIN IS
AT 42" H. IF NOT, LOWER AS REQUIRED PER NEW CABINET AND
MICROWAVE LAYOUT, CONFIRM EXACT REQUIREMENTS WITH
TENANT,
E78 CONFIRM EXACT POWER REQUIREMENTS WITH TENANT. PATCH
WALLAS REQUIRED FOR NEW FINISHES.
CON FIRM EXACT REQUIREMENTS WITH TENANT/F URN ITU RE
(,CON
FOR WALKSTATION ROOM. PROVIDE ALL POWER AS
REQUIRED FOR EQUIPMENT AND CHARGING.
OPROVIDE SEPARATE PRICE ON DEDUCTING WORK DONE IN THIS
E78 AREA.
6TH FLOOR ELECTRICAL PLAN
0 4' 8' 16'
e E
O
N �pOU
V C
m
n Z ^ 0
o 0 O40
O n
w O M
O C
h O
v � OQ
C
I
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARETHE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WR17EN
CONSENT OF SCHOTT DESIGN. -
CV
C)
0
J�� W Z
0 LLJ
o�L�
<
OW,
,
XQQQ
OV��
Z�
ZIII
W
Q Z
ZLU
��
L
ISSUE
DATE
DESCRIPTION
09.26.18
REVIEW SET
10.12.18
UPDATED SET
10.17.18
PERMIT SET
11.28.18
REVISED SET
11.30.18
REDUCED SCOPE
EVISONS
MARK
I DATE
I DIIDESCRIPTION
Mt018
CRB
REV.1
®
4
CRB
PDATED P.SET
AR10700017
STATE OF
PROJECT NUMBER
2018.263
PROD. MGR DRAWN BY
AS CRB/ JJ
6TH FLOOR
ELECTRICAL PLAN
E116