Loading...
HomeMy WebLinkAboutL105 5th Floor Life Safety2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CODE SUMMARY-5TH SCOPE OF WORK FLOOR OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS) OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA VARIES SF/FLOOR X 1 8 STORIES = 214,546 SF TOTAL PROJECT AREA 16,947 SF OCCUPANCY CALCULATIONS SPACETYPE AREA SF PER OCCUPANT OCCUP LOAD GEN. OFFICE 14,852 SF 1i IN CONF. ROOMS 940 1 IS 1 63 CAFE 1,148 1 IS 1 77 TOTAL OCCUPANTS IN PROJECT AREA 289 NUMBER OF EXITS REQUIRED:2 PROVIDED:2 SPRINKLER SYSTEM(YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 2,088 SF TOTAL AREA ON THE FLOOR 26,818 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILT BEFORE 19782 NO BUILDING CONSTRUCTION TYPE III LEGEND EP EXISTING ELECTRICAL PANEL LOCATION EJ( EXISTING EXIT. BUILDING STAIR LOCATION FE ve FIRE EXTINGUISHER ® EXITSIGN -LED EDGE LIT EMERGENCY LIGHT -EDGE LIT — — — TRAVEL DISTANCE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel �VT�'�D*S41WML_ DATE: \ 05/07/19 NAREA NOT IN CONTRACT ❑ AREA OF WORK LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE, ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY, 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM, SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10, COORDINATE WITH OWNER/LAN DLORD ON EXTINGUISHER TYPE AND HOUSING. FIRE EXTINGUISHERS PROVIDED BY GENERAL CONTRACTOR, MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. GENERAL NOTES H. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. STH FLOOR LIFE SAFETY PLAN GN 0 4' 8' 16, (� THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND AFFECT TO BE USED OR REPRODUCED IN WHOLE, OR IN PAR, MTHOUTTHE WRITTEN CONSENT OF SCHOTT DESIGN. N O J .o CL Odz O Lw 0Ln 0LLI� Q LL jY QaQ O V�n Z� zoo Z LL ISSUE DATE DESCRIPTION 09.26.18 REVIEW SET 10.12.18 UPDATED SET 10.17.18 PERMIT SET 11.28.18 REVISED SET 11.30.18 REDUCED SCOPE EVISONS T.G DRIPTION ® 518 S 04.05.19 CRB PDATED P,SET Now ttttt111111n/7� No. AR10700017 , STATE OF �L n7nnniro Iiiiiiim PROJECT NUMBER ALVI PROD. MGR DRAWN BY AS CRB/ JJ i 5TH FLOOR LIFE SAFETY L1051