Loading...
HomeMy WebLinkAbout[2] 181224 Lot 7 HVAC-M00245 DEG RECTANGULAR DUCT BRANCH OCLCONNECTION TAKE OFF. HAMMER LOCKED OR FLANGED AND FULLY SEALED ROUND SHEET METAL DUCT TO DIFFUSER V.D. 45 DEG. HIGH EFFICIENCY TAKE OFF COMPLETELY J SEALED O to.1mX ECCENTRIC TRANSITION MAX, 30 DEG. 30° MAXIM` { OFFSET. PROVIDE MINIMUM 2" STRAIGHT SECTION AT EACH END. MAX 30 DEG. 0 LL Q NOTE: IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). W HERE "R" IS EQUAL TO OR GREATER THAN"A" MINIMUM RADIUS (R) = 4 INCHES. CONCENTRIC TRANSITION MAX, 45 DEG. DIVERGING AND 60 DEG. CONVERGING IYN NOTE: DOUBLE THICKNESS TURNING VANES TO BE USED WHERE NORMAL RADIUS ELBOW IS IMPRACTICAL & WHERE ELBOW IS WITHIN 5 FT OF A BRANCH TAKE -OFF. 0DUCT CONSTRUCTION DETAILS A SCALE: NONE THIS DETAIL SHOWS TYPICAL ROUTING OF DUCTWORK WITHIN THE ROOF TRUSS STRUCTURE. REFERENCE SHEET M101 FOR SPECIFIC DUCT FSK R8.5 DUCT ROUTING INSTRUCTIONS. WRAP. TYPICAL \ SUPPLY AIR RUNS INSULATED FRESH AIR DUCT RETURN AIR RUNS REFRIGERATION LINE SET INSTALLED PER \ MANUFACTURERS RECOMMENDATIONS. FAN COIL PROVIDE OPEN SITE TEE UNIT LINED RETURN WITH MOISTURE SWITCH AIR RISER. ON SECONDARY DRAIN CONNECTION. INTERLOCK WITH HEAT PUMP. 3r4" PVC DRAIN LINE ROUTE TO DRAIN. MINIMUM 1/4" PER MANUFACTURERS FOOT, PROVIDE REMOVABLE 2" FILTER RACK CAP ON CLEAN OUT TEE FOR 18"MIN. WITH MERV 7 LINE BLOW OUT. FILTER. LJ PROVIDE LINED SHEET METAL RETURN AIR BOX UNDER FAN COIL. NO SIDE CONNECTIONS ALLOWED. FAN COIL INSTALLATION DETAIL B SCALE: NONE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel DATE: 04/17/19 GOODERUM & ASSOCIATES ENGINEERING MEP Engineer Chelte 874 7.506. 151 Way Avon, IN 46123 P: 317.745.5761 F: dave@5.5761 E: tlave@gnaengineering.mm FAN COIL SCHEDULE ELECTRIC HEAT MARK MANUFACTURER FCU MODEL HEATINGCAPACITV COOLING HEAT KIT KW BTUH NOMINAL MODEL @208 @208 TONS REFG. ELECTRICAL SPECIFICATIONS TOTAL CFM CA CFM STATIC PRESS. NOTES: ELEC. (V-Ph-Hz) MCA CIRCUIT 2 MOCP CIRCUIT 1/2 FC-1,2 TRANE TEM6AOC48H41SB BAYHTR1522BRKA 1 15 51,195 4 R410A 208-1-60 49/43 50/45 1600 160 1 .5 1 O SINGLE PHASE CEILING HUNG HORIZONTAL FAN COIL, PROVIDE WITH MANUFACTURERS ELECTRIC HEATING KIT AS SPECIFIED. HEAT PUMP SCHEDULE MARK MANUFACTURER MODEL COOLING HEATING ELECTRICAL SPECIFICATIONS NOMINAL TONS REFG. KBTU SEER BTUH HIGH BTUH LOW HSPF ELEC. (V-Ph-Hz) MCA MOCP NOTES: HP-1,2 TRANE 4TWA4048A3000A 4 1R-010A 48 14 48 1 32 1 8.7 1 208-3-60 118 30 1002 O ALL HVAC EQUIPMENT TO BE FIELD LABELED TO IDENTIFY WHICH UNIT OF THE BUILDING THEY SERVICE. O2 PROVIDE CYCLE PROTECTOR, MOUNTING PAD WITH LEGS, CA THERMOSTAT, HIGH AND LOW PRESSURE SWITCHES. DIFFUSERS, REGISTERS AND GRILLES TAG DESCRIPTION MFR MODEL MAT'L. CFM MOUNT STYLE INTEGRAL DAMPER NOTES: S-0 24"X24"LAY-IN DIFFUSER -6"NECK PRICE BCD STL 100 LAY -IN NO iO S-2 24"X24"LAY4N DIFFUSER -8"NECK PRICE BCD STL 130-225 LAY -IN NO iO S-3 24"X24"LAY-IN DIFFUSER -10"NECK PRICE BCD STL 230-400 LAY -IN NO O1 S4 6"X4" LOUVERED SIDE WALL GRILLE PRICE 520 STL 75 SURFACE NO 1 R-1 24XI2 FIXED BLADE GRILLE PRICE 530 STL 0-1000 LAY -IN NO 11 R-2 24X24 FIXED BLADE GRILLE PRICE 530 STL 0-2000 LAY -IN NO 1O iO COLOR: WHITE, SEE PLANS FOR CFMS ELECTRIC HEATER SCHEDULE MARK MANUFCTR MODEL NO. HEATING KW VOLTAGE PHASE ACCESSORIESIREMARKS EWH QMARK AWM800 4.0 208 1 iO O RECESSED WALL HEATER, PROVIDE WITH INTEGRAL THERMOSTAT. EXHAUST FAN SCHEDULE TAG MANUFACTURER MODEL# LOCATION TYPE FAN AND DESCRIPTION CFM SP SONES AMPS VOLT NOTES EF-1 GREENHECK SP-B90 VARIES CEILING 75 0.24 1.3 0.65 115 iO iO PROVIDE WITH STEEL WALL CAPPER PLAN. VENTILATION AIR CALCULATIONS PEOPLE AREA CFM REQUIRE PROVIDED SYSTEM AREA TYPE TOTAL OCCUPANTS CALCULATED CFM/PERSON CFM REQUIREMENT AREA CFM FRESH AIRD FRESH AIR NETAREA PER1000 FT OCCUPANCY REQUIREMENT REQUIRED CFM/FT2 REQUIRED CFM CFM FC-1 OFFICE 1,450 5 8 5 40 .06 87 127 160 FC-2 OFFICE 1,450 5 8 5 40 .06 87 127 160 CALCULATIONS ARE BASED ON IMC 2012 SECTION 403. REFERENCE SCHEDULES FOR INDIVIDUAL UNIT OUTSIDE AIR QUANTITIES. W M � o O U z = z 0 � w m w 4 U U w Z � az� N /W�O 2 O C w r Z_ ~ Q o J r z O_ � ¢ o o O � o � Z J J O W Y�rr LJ O 0 N U w .Z V wmmw di 0 - z W z ao ,'� o z w Ou LL a a� zx o J °z6a $ z w 3 VI SHEET NO HVAC SCHEDULES AND DETAILS DATE 12/28/18 M002