HomeMy WebLinkAbout[2] G001_LIFE SAFETY PLAN-Layout1RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City
yUof Canted
�VT�V1�0*tiYLPA4K
DATE: \\ 04/17/19
i
I
I \
I
ES
I �
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
a
'
O
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
LEVELL ONE STNE
I
I
I
I
I
EXIT
I
I
I
I
I
I
I
LEVEL TWO LIFE SAFETY
2
SCALE: 114" = P - 0"
ACCESSIBILITY NOTE:
IDENTICAL AMENITIES ARE LOCATED ON
BOTH THE FIRST AND SECOND FLOOR,
ELEVATOR NOT REQUIRED.
LEVEL ONE LIFE SAFETY
1
SCALE: 114"=1'-0" ww w w w
APPLICABLE CODES
CODE
DESCRIPTION
COMPRISED OF
GENERAL ADMINISTRATION
RULES
GENERAL ADMINISTRATION
RULES (GAP) (UPDATED 8.12014)
(AMENDED 12.12014)
6751AC 12
BUILDING CODE
(INDIANA AMENDMENTS)
2014 INDIANA BUILDING CODE 1675
IAC 13-M)
EFFECTIVE DECEMBER 1, W14
2012 INTERNATIONAL
BUILDING CODE 675 IAC 13-2.6
FIRE CODE
(INDIANA AMENDMENTS)
2014 INDIANA FIRE CODE(IFC)
EFFECTIVE DECEMBER 1, 2014
2012 INTERNATIONAL FIRE CODE
6751AC 22-2S
PLUMBING CODE
(INDIANA AMENDMENTS)
2012 INDIANA PLUMBING CODE
(IPC)
EFFECTIVE DECEMBER 24,2012
2"INTERNATIONAL PLUMBING
CODE
6751AC 16-1A
ELECTRICAL CODE
(INDIANA AMENDMENTS)
20091NDIANA ELECTRICAL CODE(IEC)
EFFECTIVE AUGUST 26, 2009
2006 NFPA 70
6751AC 17-1S
MECHANICAL CODE
(INDIANA AMENDMENTS)
2014 INDIANA MECHANICAL CODE(675
IAC 18-1.6) EFFECTIVE DECEMBER I,
2014
20121NTERNATI0NAL MECHANICAL
CODE
6751AC 181
HANDICAPPED ACCESSIBILITY
CODE (INDIANA AMENDMENTS)
2008 INDIANA BUILDING CODE
CHAPTER 11-ACCESSIBILITY
6751AC 13-2.5-12 CHAPTER 11
ENERGY CODE
(INDIANA AMENDMENTS)
2010 INDIANA ENERGY CONSERVATION
CODE(IECC)
EFFECTIVE MAY T, 2010
ASHRAE STANDARD 90A, 2001
6751AC 194
ELEVATOR SAFETY CODE
2011 INDIANA ELEVATOR SAFETY CODE
(IESC)
(UPDATED 9-28-11)
6751AC 21- ANSI I ASMEA17.1, 2007
ANSI I ASME AW.1, 2003
ANSI IA10A, 2004
ASME I At 8.1, W05
BUILDING REHABILITATION
STANDARD
(INDIANA AMENDMENTS)
INDIANA BUILDING REHABILITATION
STANDARD (GAR)
(UPDATED 12.22TA)
(REPEALED JUNE 18, 2006
6751AC 12-8
SANITARY CODE
(INDIANA AMENDMENTS)
1998 AMERICAN SOCIETY OF
SANITARY ENGINEERS STANDARD
1051
6751AC 16-2
CODE ANALYSIS
CONSTRUCTION TYPE
VB
OCCUPANCY CLASSIFICATION
B- DOCTORS OFFICE
AREA -LEVEL ONE
LEVEL ONE PROPOSED- 1540SOFT
AREA-LEVELTWO
LEVELTWO PROPOSED - 1448 SO FT
OCCUPANCY -LEVEL ONE
LEVEL ONE -1540I100=16 OCCUPANTS
OCCUPANCY -LEVEL TWO
LEVEL TWO - 1MB I100=15 OCCUPANTS
ALLOWABLE AREA
TABLE 503- 9000 BE MAX ALLOWABLE
ALLOWABLE HEIGHT
TABLE503-2 STORIES
FIRE SPRINKLERS
NOT REQ'D PER TABLE SID AND CHAPTER
EXITING
LEVEL ONE-1 EXIT REQUIRED-1015.1- LESS THAN 50
LEVEL TWO -1 EXIT REQUIRED - 10212 - LESS THAN 29
MAXIMUM TRAVEL DISTANCE
LEVEL ONE -TABLE 10162-LESS THAN 20P
LEVELTWO -TABLE 1021.2- LESS THAN 15'-SEE PLAN
STAIRS - OPEN PER IONS EX 1
RATED CORRIDORS
RATED CORRIDORS NOT REDD-SEC 1018 EX4
EGRESS DOOR HARDWARE REQUIREMENTS
NO REQUIREMENT PER 1006.1.10
EGRESS DOOR SWING
NO REQUIREMENT PER 10M.12
MOP SINK-1 PROVIDED PER TENANT
WATER COOLER -EACH TENANT TO PROVIDE BOTTLED WATER IN LIEU OF
DRINKING FOUNTAINS
0
W
rn
�I
ZME
I
m
W
Z
NI
Q
0
(]
ZU
U)
Dx
m
W
M
�
rn
OVO�Z(n
IL
Q
w
Z
a
D
W
LL
O
F
W
Z
—
_
�
W
N
a
W
2
W
ooJ
a
a
NC)2W
n
U
a
SRS ARCHITECTS INC
200 S RANGELINE RD , #226
CARMEL, INDIANA 46032
PHONE: 317-989-6248
E-MAIL : sshaAe@mitschAesi9n.com
CERTIFICATION:
RESERYEq EYLEPT FOR USES E%W ESSLY
GERMTED IN WRRING.
REV 1: 1 AUG, 2018
REV 2:
SHEET NUMBER:
CODE AND LIFE
SAFETY PLAN
0001