HomeMy WebLinkAboutA5 adaBUILDINGELEMENTS NOTE: All conditions are not represented in these details. It is the responsibility of the General Contractor to comply with all applicable codes, to include accessibility requirements. The details shown have been provided as a courtesy. n as Ramps RAMP ELEVATIONS 12' MIN 11 JIN �SLOPE Wi\DIwTIRR1 "P" CONFIGURATION PER FIGURE 505.10.1 IS AN ACCEPTABLE ALTERNATE CURB RAMP Curb or Barrier, Typ. 12 MIN, 12'MIN. �SLOPE WALL LANDING WALLMOUNTED HANDRAIL RAMP SECTIONS N X"MIN. rat WHERE NO EDGE 12 PROTECTION PROVIDED Lf—SLOPE 12" MIN. y� 'X' MIN. NL 8NL TTIN I I U ESS U G LANDING WALL ONE SIDE LANDING . p VERTICAL GUARD RAIL are or Bamer, Typ. < F GRADE DIFFERENTIAL IS>=39% w cx HI = 42" AND HANDRAILS ATTACHED i TO GUARDRAIL WILL BE REQUIRED LEVEL F P LANDING LEVEL LANDING HORIZONTAL PR E TI N R RUN SLOPE MAXIMUM RISE 1:20 TO<=1:12 30' 1:12TO<=1:10 6" (EXISTING) 1:8 TO<=1.8 3' (EXISTING) CROSS SLOPE SHALL NOT EXCEED 1:48 NOTES ON SECTION I.X=36"MIN. IF RAMP 15 LESSTHAN30'IN LENGTH 2. X - 44" MIN. IF RAMP IS GREATER THAN 30IN LENGTH. NOTE: Edge protection required at all ramps, per 405.9 NOTES ON HANDRAILS: 1."Th IS HANDRAIL HEIGHT TO TOP. la."H l"SHALL BE BETWEEN 34" AND 38" MAXIMUM FOR ALL ADULT USES, UNLESS OTHERWISE NOTED. 1b.AT BUILDINGS WITH CHILD OCCUPANTS, PROVIDE A SECOND HANDRAIL MOUNTED AT 28" ALL. PROVIDE A MINIMUM OF 9" CLEARANCE BETWEEN THE ADULT AND CHILD HANDRAILS (ADJUST HEIGHT OF ADULT HANDRAIL AS REQUIRED). 2. HANDRAILS ARE REQUIRED FOR ANY RAMP RISE GREATER THAN 6" j x Curb or Barrier required that prevents passage of 4' diameter sphere anywhere Within 4" of the finished floor or ground surface. LANDINGS: RAMPS SHALL HAVE LEVEL LANDINGS AT THE TOP AND BOTTOM OF EACH RAMP RUN (MAX. SLOPE OF 1:481N EACH DIRECTION). RAMPS AND LANDINGS SHALL HAVE EDGE PROTECTION AS PER 405.9. LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. "MIN. 60 MIN landing ramp run landing Curb Ramps AS CURB RAMP �E­ -I PROVIDE LANDING AT CURB RAMP SLOPE TOP OF CURB RAMP ADJOINING SURFACE MAXIMUM 36 SLOP E MAX 20 1 u I' MyX. ro \10MAX COUNTER SLOPE OF SURFACES ADIACENT TO CURB RAMPS � m DETECTABLE WARNING DEVICE PER 705 NOTE: REFER TO 407 FOR ALL ELEVATOR INFORMATION Vehicle Parking Spaces REFER TO 503 FOR REQUIREMENTS AT PASSENGER LOADING ZONES SIGN A -E ACCESS AISLE MUST ADJOIN ACCESSIBLE ROUTE ACCESSIBLE CAR PARKING SPACE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel DATE: 05/07/19 /// —ACCESS AISLE SHALL BE CONNECTED TO / ACCESSIBLE PROVIDE ROSSW LK BUILDING. / ROUTE CROSSES STRIPING WHERE ROUTE CROSSES VEHICLE DRIVE AISLES. / -VAN PARKING SIGNAGE I( I( � CURB RAMPS MAY NOT PROJECT INTO ( ACCESS AISLE ( ( ACCESSIBLE VAN PARKING SPACE (98"MINIMUM ( VERTICAL CLEARANCE REQUIRED AT SPACE AND ( ADJACENT ACCESS AISLE) I( ( NOTE: AT ANGLE PARKING SPACES, ACCESS AISLES ( REQUIRED FOR VAN ( ACCESSIBLE SPACES SHALL ALWAYS BE ON THE ( PASSENGER SIDE OF THE ( SPACE. I ALTERNATE STRIPING AT VAN ACCESSIBLE ( SPACE J( �,.,•.• STRAIGHT RUN VAN ACCESSIBLE SIGN PROVIDE ONE SIGN AT EACH ACCESSIBLE PARKING SPACE i I�� z � MIN 2-1E12" DIA. SIGN SCHED. 40 o GALVANIZED 36"MIN PRGw W AUTO Vnry SPACE ® I Ohar Note: Characters end o symbols on such signs shall be located 60" SIGN min, above the ground floor, or paving surface so they cannot PARKING SIGNAGE SHALL NOT IMPEDE be obscured by a ACCESSIBLE ROUTE, TYP. vehicle parked in the space. Stairs 11 MIN 10 MA> 1RADIUS Handrail & Grab Bars Extension shall z return to landing. FLUSH RISER I I/ " onguard, or wall. I I /4" to 2, Handrails may also be 1 1/2-MAX continuous to the (7/yam HANDRAIL — handrail of an Qom/ \ 1 1 /2 adjacent flight of EXTENSION AT TOP OF RUN stairs. ANGLED NOSING 1 I/ " I 1 1/ 4" 10 2" 1 1 /2" MAX.�— —I� W ifW. Extension shall O� GRAB BAR HANDRAIL HANDRAIL return to landing, d NOTES ON HANDRAILS: guard, or wall. HANDRAILS TO BE INSTALLED WITH TOP OF GRIPPING SURFACE BETWEEN 3A AND 38" Handrails may MAXIMUM ABOVE FINISHED FLOOR FOR ALL ADULT USE.also be continuous to the handrail of an AT BUILDINGS WITH CHILD OCCUPANTS, PROVIDE A SECOND HANDRAIL MOUNTED AT 28" adjacent flight of ROUNDED NOSING AFF. PROVIDE A MINIMUM OF 9" CLEARANCE BETWEEN THE ADULT AND CHILD EXTENSION AT BOTTOM OF RUN HANDRAILS (ADJUST HEIGHT OF ADULT HANDRAIL AS REQUIRED). stairs. NOTE: NOTE : l."X IS THE TREAD DEPTH. OPEN RISERS ARE NOT HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 2. HANDRAILS REQUIRED AT BOTH PERMITTED SIDES OF STAIR. HANDRAIL EXTENSIONS SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS. CHAPTER 6: PLUMBI Drinking Fountains 5 Dashed Line represents - 6„ minimum Knee Clearance MA requirements, as per 306.3 FRONT APPROACH "LOW' DRINKING FOUNTAIN 44 ;FM 4Ikk&i AIkill Dashed Line represents Clear Hoar Space requirements, as per 305 PARALLEL APPROACH IS PERMITTED FOR UNITS FOR CHILDREN'S USE ONLY, WITH THE SPOUT OUTLET MOUNTED AT 30" MAXIMUM ARE, AND 3 1 /2" MAXIMUM FROM THE FRONT EDGE OF THE UNIT INCLUDING BUMPERS. Spout NOTE: Drinking Fountain shall comply with 602.6 for Water Flow rag moments. �Q E> O� O 0w e0 Dashed lines represent Protruding Object protection required as per 307 if Drinking Fountains are not installed in an alcove. Alcove may be open on I side, as long as the low drinking fountain is installed at the open side to provide the required Protruding Object protection (AND as long as the bottom of the drinking fountain is 27' MAX. AFF). Water Closets and Toilet Compartments WATER CLOSET LOCATIONS WATER CLOSET CLEARANCE I "- 1 1 MIN NOTE: the required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, z shelves, accessible routes, clear floor space Clear I and clearances required at other fixtures, and Floor the turning space. No other fixtures or vv HEELCHAIR AMBULATORY Space obstructions shall be located within the ACCESSIBLE ACCESSIBLE _ _ _ required water closet clearance INCLUDING S _ WATER CLOSETS WATER CLOSETS LAVATORIES). Lavatories may overlap the (Required if total toilet required clearance at wafer closets of pmate +urinal fixture count is residential dwelling units ONLY. greaterihan 6) TOILET COMPARTMENT _ CLEARANCES jr—Altemate Door Location AMBULATORY ACCESSIBLE TOILET iJ Clear Floor Space Toe Clearance required at front and ONE side EXCEPTION: Toe 56 MIN. At clearance not required at Adult WolHung front addition if 62' depth at Wall Hung WC or 65" depth at Floor Mounted Adultnear 9"MIN.At u Maumee WC. Toe Clearance not required at side partition if WC and all 66"clear width is Children WC provided Showers Kitchens Provide the following minimum clearances IF/WHEN a apoktop and/or conventional range is present, ONLY, i o0 fl�f , �0 PASS-THRU KITCHEN U-SHAPED KITCHEN U-SHAPED KITCHEN Provide maneuvering clearances to Seating, Furnishings and Tables, as per 305 for a Forward Approach. Knee and toe clearances complying with 306 shall be provided. 6' MAX. to Edge IF built-in Dining or Work Surface is within Accessible Route, provide end panel as required for Protruding Objects L" g `n Min. & 30" Max. where Dashed Line represents Di Dining and Work Surfaces are minimum Knee Clearance primarily for Children's Use MAX requirements, as per 306.3 Nquiremeents of for ff DINING SURFACES AND WORK heck-04 requirements al Check -Out Aisles u SURFACES HEIGHT REQUIREMENTS and Service Counters Reference III for Clear Floor Space Requirements adjacent to Exercise Machines and equipment. I and Held Shower 2 1/2 Ma ' Back Wall Head on 60' Hose. 4 Ref. 608.6 for all Folding or -- requirements o Fixed Seat Q E m � _ 1 "- 16" ih Control Wall NOTE: Reference 609 m for all Grab Ba, Control Area 36" X 48" Clear I requirements Grob Bars 1, Floor Space (Min.) Control Wall 1/2" Curb (Max.) SHOWER PLAN AL SHOWER ACCESSIBLE SHOWER STALL SEAT REQUIREMENTS 20 94 NOTE: A Bench is required at Shower Rooms as per Section 903 -8 rovide Back Support Grab Bar 20-24 Wet Locations. .p _ Folding Seat surface shall not accumulate water & 36" X 4S Clem shall be slip -resistant Floor Space 1/2"Curb Min.) (Max.) NOTE: 30"X 48"Clear Back Wall Section Floor Space permitted Plan if NO obstruction at 3rd ACCESSIBLE SHOWER STALL side of Bench alcove BUILT-IN BENCH AT SHOWER ROOM COMPARTMENT CLEARANCES Doors at Toilet Compartments to comply with 404 (excludingJ60MIN, latch side approach clearance width requiredwhich shall be as shownn the diagram to the left). Doors shall be self closing, with a 42MIN door pull complying with 404.2.7 placed on both sides of the door, near the latch. Door may not swing into the TOILET COMPARTMENT TOE CLEARANCES required minimum Clear Floor Space. 6" Coats and Shelves (id iMIN. provided) shall be installed within Reach Ranges as specified in 308. Required toe i clearance at front and ONE side 4 partition. Mirrors E u a o E u a V O o MIRROR ABOVE LAVATORY OR COUNTERTOP m u V O Nt FULL-LENGTH MIRROR GRAB BAR, FLUSH CONTROLS, R SEAT HEIGHT DISPENSER OUTLET LOCATION URINALS REQUIREMENTS "MAX Grab Bor (Typ.) 13 1 /2 Min. 36MIN. 131/2"Min.MIN. 12 IN. : ProvitleE rFoorSpace pying with ff54mm.24 ardTransfer LF oach (305) Side 16^-18" cessible Side Wallf, Flush Back Wall Wall Hung Type Stall Type Controls Hot wafer and drain pipes under lavatories and handicap 17' MIN. & accessible sinks shall be installed or otherwise configured 25MAX. TO EDGE LAVATORY AND SINK REQUIREMENTS to protect against contact. OF TOE CLEARANCE Min. 25"Max. 175 Min, Dashed Line represents minimum 25"Max. Knee Clearance requirements. as per 306.3 PARALLEL APPROACH 15 PERMITTED FOR LAVATORIES F— —— AND SI KS USED I ARILY AND SINKS .c 9N BY ES AND N AGE AND �- UNDER. X J t6max. 48Min. Z p m� MAX11"MIN.CTE: Provide 24" Dashed Line represents Clear Floor clearance to bottom of Space requirements, as per 305 sink/apron and 31'to fop LAVATORY SINK COUNTER MOUNTED SINK rim of sink for Lavatories PLAN and Sinks used primarily by children aged 6-12 -Inside Stall . Padition MOUNTING HEIGHTS FOR WATER CLOSETS SERVING AGES 3 THROUGH 12 J GRADE LEVEL/AGE WC TOILET SEAT GRAB BAR DISPENSER (T Q a w z CENTERLINE HEIGHT HEIGHT HEIGHT �F 6 x_ Ages 3 and 12' I1"-12' 18"-20' 14 V Ages 5 and 12"-15" 12'-1S, 20"-25" 14"-17' Ages 9 and 12 1S'-18" IS'-17' 25"-27' 17" 19' Of W Z U Q a Z W W_ �/ L.I_ FW W c LL X o 0 W 5 Z r T J ziEd z co Y r co >. Q�Q / az� N LL o X ac E w L I— W I- 2 UN LL W F a U Q W >- Z:3 Q � U Q Koo ULJ >E-Z Q U NNW Z v K Q m U W PROJECT NUMBER: 2019.04 DATE: MARCH 04,2019 DRAWING NUMBER A.5 5