HomeMy WebLinkAboutej 6 of 6EDWARD JONES GENERAL BUILDING AND FINISH SPECIFICATIONS. EXTERIOR ONLY METAL DOORS, JAMBS B FRAMES TWO FINISH COATS OVER A PRIMER. • SHERWINWILLIAMS: • PRIMER: SHERWINWILLIAMS DTM ACRYLIC PRIMERIFINISH, B66W1 • 1ST82ND COATS'. SHERWIN-WILLIAMS PROCIASSIC WATERBORNE IND ACRYLIC SEMI -GLOSS ENAMEL, B31 W51 SERIES • COLOR: SWn23-COLONY BUFF OR BENJAMIN MOORE: PRIMER -A'. M04 METAL PRIMER USED FOR BARE METAL AND SPOT PRIMING. APPLY AT SPREADING RATE TO ACHIEVE A TOTAL DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS (0.031 MI BENJAMIN MOORE ACRYLIC METAL PRIMER, MW 1ST 82ND COATS M29 DTM SEMIGLOSS ACRYLIC -LATEX ENAMEL APPLIED AT SPREADING RATE TO ACHIEVE ATOTAL DRY FILM THICKNESS OF NOT LESS THAN 26 MILS It 066MMF BENJAMIN MOORE DTM ACRYLIC SEMIGLOSSENAMEL, MN COLOR: HC-39 PUTNAM IVORY 11. ELECTRICAL a. ELECTRICAL TO INCLUDE OUTLETS AS SHOWN ON PAGES 283, INCLUDING DEDICATED OUTLET AS SHOWN ON PLAN. 1. GENERAL PURPOSE OUTLETS • ALL OUTLETSTO BE PLACED AS SHOWN ON DRAWING. • ONE (1) QUAD OUTLET AT FUTURE WORKSTATION LOCATION AND(2)QUAD OUTLETS AT BOA WORKSTATION. • AT ALL TERMINALS AND OTHER OFFICE EQUIPMENT AS SHOWN ON THE PLAN. 2. DEDICATED OUTLET • DEFINITION'. A DEDICATED OUTLET IS WIRED DIRECTLY TO THE MAIN POWER DISTRIBUTION PANEL THROUGH A DESIGNATED (DEDICATED) CIRCUIT BREAKER. THE DEDICATED OUTLETS ARE COLOR CODED TO DISTINGUISH THEM FROM GENERAL-PURPOSE OUTLETS. ONLY THE BOC SHOULD BE PLUGGED INTO THE DEDICATED OUTLET. THE TECHNICAL INFORMATION FOR THIS OUTLET IS AS FOLLOWS'. • ONE DEDICATED OUTLET (SIMPLEX, NOT DUPLEX) REQUIRED FORTHEBOC(SEE LEGEND ON SHEET 10F 6). • OUTLET TO BE STANDARD B-PRONG 120 VOLT, 20 AMP, DEDICATED CIRCUIT. • OUTLET TO BE SIMPLEX, ORANGE COLOR COOED RECEPTACLE(NEVA TYPE 515 WIG OUTLET, GE5362-IS OR EQUIVALENT). • ALL GROUNDS MUST HAVE SAME GROUND POTENTIAL. 3. RECESSED OUTLET • LEVNON RECESSED ONE- GANG DUPLEX RECEPTACLE (15A125VAG2POLE, 3WIRE - NEMA5 15R)-CAT N0. 689 TO INCLUDE ELECTRICAL BOX. • CATALOG NO.012 0066WW', UPC N0. 07911312M 1 • IF ABOVE SPECIFICATION IS UNAVAILABLE, FIND COMPARABLE ALTERNATIVE b. ALL OUTLETS TO BE 110 VOLT STANDARD 3 PRONG OUTLETS THAT MEET STATE AND LOCAL REQUIREMENTS (NEMA TYPE 545R). THE GROUNDING CONDUCTORS FOR THE BUILDING'S CIRCUITS SHOULD BE REFERENCED TO THE POINT OF 'ZERO CWRRENT•WITHIN THE ELECTRICAL SUPPLY SYSTEM, WHICH IS WHERE THE NEUTRAL AND GROUND FOR TF- SYSTEM ARE TIED TOGETHER. A. EXISTING OUTLETS CAN BE USED TO MEET THE REQUIREMENTS FOR GENERALYURPOSE OUTLETS ONLY. VERIFY EXISTING OUTLETS TO REMAIN ARE IN WORKING ORDER. d. NEW ELECTRICAL OUTLETS TO BE INSTALLED WHERE SHOWN ON PLANS AT IO "AF F. UNLESS AN EXISTING DEVICE IS ALREADY WITHIN 36 OF THE DESIRED LOCATION. e. DEMOIREMOVE OUTLETS ADOVE IB"AE.F. UNLESS NOTED OTHERWISE ON PLANS. L INSTALL OR REPLACE ALL OUTLET COVERS WITH WHITE FACEPLATES OR TO MATCH EXISTING. CONFIRM COLOR WITH DESIGNER IF OTHED THAF CM HF. RELEASED FOR CONSTRUCTIONTIC Subject to compliance with all regulations of State and Local Codes CNy of`Canned \n, DATE: 05/07/19 L CONTRACTOR TO INSTALL 2'X2 MINIMUM BACKER BOARD OF FRT PLYWOOD AT BOC LOCATION. BOARD TO BE PAINTED TO MATCH THE WALL WHEN THE WALLIS SCHEDULED FOR PAINT PER THE FINISH SCHEDULE. CONFIRM WITH FIRE MARSHALL PRIOR TO PAINTING AND LEAVE RATING STAMP EXPOSED WHENEVER REQUIRED. BOARDTOBE INSTALLED AT24'AFF. TO THE BOTTOM ATTHE LOCATION SHOWN ON THE PLAN. REFER TO SHEET 60F 6 FOR EXACT LOCATION. N. ELECTRICIAN TO INSTALL 314•CONDUIT B BOX WITH PULL STRING OR MUD RING(EXISTING WALL) AT ALL LOCATIONS (SEE SECTION 4 BELOW) WITH LOW VOLTAGE COMMUNICATION CONNECTIONS. INSTALL (1) SINGLE GANG BOX AT EACH LOCATION INDICATED ON THE DRAWING WITH ATRIANGLE(♦). DO NOT INSTALL A DOUBLE GANG BOX AT LOCATIONS WHERE (2) SYMBOLS ARE ADJACENT. REFER TO LEGEND AND PLANS ON SHEETS 1d FOR LOCATIONS OF DOUBLE GANG BOXES. IF CONDOR IS NOT GOING TO BE INSTALLED, PLEASE CONTACT DESIGNER IMMEDIATELY. I. ELECTRICIAN TO INSTALL ONE Y4"CONDUIT FROM BUILDING MAIN POINT OF ENTRY(MPOE) INTO BOTH SINGLE GANG ELECTRICAL BOXES FOR INCOMING PHONE JACKS (RJ11) WITHIN 1'0" OF BCC PER DETAIL ON PAGE 60F 6. INC WILL INSTALL THE QUANTITY OF CATS PHONE LINES INDICATED ON SHEET 2 OF 6, CONTRACTOR TO COORDINATE WITH INC. (INTEGRATED NETWORK CABLE, CONTACT INC INSTALL TEAM AT 888-519-9525). 12. LOW VOLTAGE (ALSO KNOWN AS PHONEATATA CABLING) CONDUIT DEMISED PREMISES a. CONDUIT STUB UPS TO BE INSTALLED IN NEW WALLS WHERE PHONEIOATAJPRINTERSABE SHOWN ON THE FLOOR PLAN (INDICATED BY TRIANGLEV ) IF THE NEW CEILING IS DRYWALL, INSTALL CONDUIT FROM THE POINT OF CONNECTION(PHONESIDATPJPRINTER LOCATIONS INDICATED WITH ♦)AND STUB ABOVE CEILING WITH PULL STRING RUN TO THE POINT OF TERMINATION (CLIENT SERVER OR BOCL b. CONFIRM ACTUAL LOCATIONS ON FLOOR PLAN SHEET 20F 6 PRIOR TO INSTALLATION. EXISTING CONSTRUCTION -CONDUIT NOT TO BE DONE IF IT REQUIRES REMOVAL OF DRYWALL PARTITIONS OR CEILINGS , UNLESS PRIOR APPROVAL RECEIVED FROM EDJ DESIGNER. IF WIREMOLD PRODUCT IS REQUIRED, INSTALL PANDUIT RACEWAY LDl OE16 A. c. PROVIDE ONE SINGLE GANG BOX (ONE PER TRIANGLE) AND PULL STRING AT EACH CONDUIT LOCATION. LABEL PULL STRINGS AT POINT OF TERMINATION (BOC) WITH ROOM NUMBER OF POINT OF CONNECTION. d. IF WALLS ARE EXISTING AND CONDUIT IS NOT INSTALLED, PROVIDE PULL STRING AND CUT IN A NEW BOXAT THE SAME LOCATIONS. e. STANDARD STUB -UP QUANTITY: TEN(10) 314"DIAMETER LOCATIONS, UNLESS NOTED OTHERWISE ON PLANS- INDICATED BYTRIANGLE SYMBOL ON FLOOR PLANS. a. 314" CONDUIT LOCATIONS • (2) AT BOA (ROOM 101) (1) AT FA OFFICE (ROOM 102) (Q AT BOC INTO DOUBLE GANG BOXES • (2) AT INCOMING PHONEMATA LINES TO BOC PER PUN (ONE ACTIVE FOR PHONES AND ONE WI #6 GROUND WIRE RUN FROM BOX TO ELECTRICAL PANEL TO GROUND BOX FOR DATA) (1) AT OPEN 106 I. ALL BOXES AND CONDUIT AT BUD LOCATION TO BE INSTALLED PER DETAIL BELOW. #6 GROUND WIRE MUST BE INSTALLED AND TERMINATED ON A BUSBAR FOR #6 WIRE MOUNTED ON THE BOTTOM CORNER OF THE BACK BOARD. THE BUSBAR SHOULD HAVE 4 TO 6 TERMINALS. CONDUIT AND PHONE LINES FROM BUILDING SOURCE TO EXTENDED DEMARC (BOG) a. GENERAL CONTRACTOR TO INSTALL (2) 314'CONDUIT FROM THE BUILDING SOURCE TO THE EXTENDED DEMARC LOCATION WITHIN THE BRANCH (BOC LOCATION SHOWN ON PLAN) AS WELL AS COORDINATE WITH INC TO INSTALL CATSE PLENUM RATED PHONE LINES IN QUANTITY SPECIFIED ON PAGE 2. INC CONTACT INFORMATION IS AVAILABLE ON SHEET 10F 6 .•" IF DATA LINES ENTER BUILDING AT A DIFFERENT LOCATION THAN PHONE LINES, (1) CONDUIT WILL NEED TO COME FROM THE DATA SOURCE TO THE GROUNDED BOX AT THE BOG LOCATION. REMAINING CONDUIT SHOULD BE RUN IN FROM THE PHONE LINE SOURCE TO THE BOC LOCATION•"" a. CONTACT BRANCH FACILITIES IMMEDIATELY IF THERE ARE ANY QUESTIONS REGARDING THE NUMBER OF PHONES LINES OR LOCATION OF DEMARC EXTENSION CONDUIT. BOC REQUIREMENTS: NOTE: CONDUIT IS INSTALLED INSIDE WALL. IF WALL IS EXISTING, CONDUIT MAY BE SURFACE MOUNTED. MUST HAVE ROOM FOR EQUIPMENT TO INSTALL ON PLYWOOD. (SEE KEYED NOTE #10N PAGE 2OF 6 FOR CLARIFICATION.) 3WCONDUIT TO LED 3W CONDUIT TO ALL DMARC BOX ( WORKSTATION LOCATIONS SINGLE GANG PHONE TOMATO TT PAINTED BOX WITH STRING ALL WILABE WALL TO MATCH WALLWMBEL GROUND AND dfi GROUND WIRE EXPOSED, INSTALL AT 24'A.F.F. BY GO (INC TO RUN (1) TO BOTTOM; BOARD SUPPLIED& CATSE LINE TO THIS INSTALLED BY GC. LOCATION) DEDICATED SIMPLEX OUTLET TO ACTIVE SINGLE GANG BE MARKED WITH •D"8ORANGE PHONE BOX WITH PULL INDICATE DEDICATED BY GC. STRINGS BY GOINC TO RUN REMAI (4) DOUBLE GANG PHONE BOXES. GC THISNING LINES TO CATSE LINES THIS ( TO RUN PULL STRING THROUGH LOCATION) STUD Y .li EACH CONDUITRUNTNCTORUS II REMAININGCABLES WORKSTATION LOCATIONS C SEE LOCATIONS LOW VOLTAGE WIRING SPECS. WIRING (ALSO MOWN AS PHONEIDATA CABLING) a. LOW VOLTAGE IMPLIES THE ACTUAL WIRE OR CABLE THAT IS RUN FROM THE BUD TO EACH PHONE, COMPUTER, PRINTER, AND FUTURE WORKSTATION LOCATION. WITH THE EXCEPTION OF THE DEMARC EXTENSION (ROCS REFERENCED IN SECTIONS LOW VOLTAGE WORK IS DONE BY EDWARD JONES BRANCH INSTALL DEPT. THROUGH A PREFERRED NATIONAL VENDOR, CBIZ. THIS WORK IS DONE AFTER THE SPACE IS TURNED OVER TO EDWARD JONES. b. IF LOW VOLTAGE WORK IS REQUIRED TO BE PERMITTED AND INSPECTED AS NOTEDONEXHIBITA PRIOR TO CLOSING ANY NEW PARTITIONS GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION WITH EDWARD JONES PREFERRED NATIONAL VENDOR INC. INC CONTACT INFORMATION IS AVAILABLE ON SHEET 10F 6 NOTE THAT PRE -WIRE IS NOT STANDARD AND IS ONLY DONE WHEN REQUIRED VS. BEING DONE FOR CONVENIENCE. THERE IS A WIRING SPECIFICATION AVAILABLE FOR PROJECTS REQUIRING PREWIRE. c NOTIFY BRANCH FACILITIES OF LOW VOLTAGE REQUIREMENTS NEEDED IN ORDEF TO OBTAIN CERTIFICATE OF OCCUPANCY. 1. ELECTRICAL BOXES -4X2-118D RANDY BOX MUST BE USED, PER DIAGRAM BELOW FOR ALL LOW VOLTAGE APPLICATIONS IN NEW WALLS AND CONCRETE WALLS. 2. MUD RINGS-MRS METAL SINGLE GANG DRYWALL MOUNTING PLATE ,PER DIAGRAM BELOW FOR ALL LOW VOLTAGE APPLICATIONS IN EXISTING WALLS. a. FIXED WINDOW(ONLY IF SHOWN ON PAGES 283) V 1. NEW INTERIOR WINDOW BETWEEN FA OFFICE AND BOA AREA TO BE A FIXED, 42•W X 30'H AND INSTALLED AT 42"A F F, UNLESS NOTED OTHERWISE', FRAME TO BE WOOD (OR TO MATCH DOOR FRAMES). _ r 2. PAINT WOOD TRIM WHITE TO MATCH DOORFRAME COLOR. 3, GLASS TO BE CLEAR,Y•TEMPERED STATIONARY PANEL. GLIDERS AND 1,t3�y MIRRORED WINDOWS NOT ALLOWED. _ b. FIREPLACES, STOVES, SHOWERS, TUBS 1. ALL GAS AND PLUMBING LINES TO THESE ELEMENT&FIXTURES TO BE rb w RENDERED INOPERABLE AND ALL LINES TO BE CAPPED. �i3:IC11/_�