HomeMy WebLinkAboutLEGACY PRAIRIE 104 - LP104 (AS DESIGNED)IECC 2009 Performance Compliance
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN -111 (D)
Community: LEGACY PRAIRIE 104
LP104 (AS DESIGNED)
LEGACY PRAIRIE 104
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$770
$131
$350
$1,252
$567
$0
$1,818
Requirements
C4405.3
Performance-based compliance passes by 7.7%
402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration 11 -11 -Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
5677
5127
5356
$1,155
S567
S6
$1,721
Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 5D Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 7.7%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Digitally signed: 3/11119 at 9:43 AM
Ekotrope RATER - Version 3.1.0.2128
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7249 BARKER ST
Alin MMAlI=1:11a]I,l21I
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor R-38
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 6 ACH50
Window U -Value: 0.32, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 139.0 CFM @ 25Pa
Total Duct Leakage 279.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. — -y
Name: Matthew Timmons Signature: ��r�,.c z � —
Organization: TSI Energy Solutions
Digitally signed: 3111119 at 9:43 AM
Ekotrope RATER - Version 3.1.0.2128
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
7249 BARKER ST TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: MERIDIAN -111 (D)
Community: LEGACY PRAIRIE 104 Builder
LENNAR HOMES
LPI 04 (AS DESIGNED)
LEGACY PRAIRIE 104
General Building Information
Conditioned Area (sq ft) 2,330
Conditioned Volume (cubic ft) 19,622
Insulated Shell Area (sq ft) 4,762
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: LOWER (527 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (4 80 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,463 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2x6 (135 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (240 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
7249 BARKER ST TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: MERIDIAN -111 (D)
Community: LEGACY PRAIRIE 104 Builder
LENNAR HOMES
LP104 (AS DESIGNED)
LEGACY PRAIRIE 104
Name: CONDICOND (646 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (188 s.f.)
R: 13.575
Roof
Name: CONDICOND (76 s.f.)
R: 10.876
Name: ATTIC (1,007 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (98 s.f.), U:0.320, SHGC: 0.28, Orientation: EAST
E] Name: FRONT 2X6 (30 s.f.), U:0.320, SHGC: 0.28, Orientation: EAST
El Name: BACK (84 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
El Name: SLIDER (35 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
El Name: RIGHT SIDE (102 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN -111 (D)
Community: LEGACY PRAIRIE 104
LPI 04 (AS DESIGNED)
LEGACY PRAIRIE 104
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,952 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 139.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 279.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN -111 (D)
Community: LEGACY PRAIRIE 104
LPI 04 (AS DESIGNED)
LEGACY PRAIRIE 104
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN_III [D]
Community: LEGACY PRAIRIE 104
LP104 [AS DESIGNED]
LEGACY PRAIRIE 104
Genera%uiiding Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Model
Community
Climate Zone
Basement Wall
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
3
2
2;330
Yes
19;522
1
Townhouse; end unit
M'ERIDIAN_III (D)
LEGACY PRAIRIE 104
5A
None
Basement Wall Library List
None Present
Slab
C-M,
Energy Solutions
1P
Exposed Surface Area Location Enclosing
Masonry Area
LOWER R-10, 2'down
73 an Grade 123
0 527.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List "s
W
Name Wall Construction Type
Slap Completely
Underslab Insulation
Perimeter Insulation PerPmeterinsufation R R -value
Insulated.
Width [ft]
Depth [Pt] Value
IR-10, 2'down Wood Frame / Other
No
0
2 1 D 0.00
Framed Floor
Name Library Type
Carpet R
Floor Grade Surface Area Location
I OVER GARAGE R-38, GR1
123
Above Grade 480.0 sq. rL Unconditioned, attached
garage
1
Building Summary
Property
Organization
7249 BARKER ST
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: MERIDIAN_III [D]
Community: LEGACY PRAIRIE 104
Builder
G1 R-13 BATT, R-3.0
LENNAR HOMES
LP104 [AS DESIGNED]
CONDIAMB 2x6
LEGACY PRAIRIE 104
ramed Floor Library List
Exposed Exterior
Name
Rvaluf
R-38, GR1
CONDICOND
33.825
Rim Joist
Conditioned Space [Adiabatic]
Name
Library Type
CONDIAMB
CONDIGAR
G1 R-13, R-3.0
CONDICOND
G1 R-13, OSB
G1 R-19, 2x6 GAR
Rim Joist Library List
240.0 sq. ft.
Name
R value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
I
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Area Location
188.0 sq. ft. Exposed Exterior
76.0 sq. ft. Conditioned Space (Adiabatic)
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
Exposed Exterior
G1 R-13 BATT, R-3.0
Medium
1.463.0 sq. fl.
CONDIAMB 2x6
Exposed Exterior
G1 R-19, R-3.0 2X6
Medium
135.0 sq. Pl.
CONDICOND
Conditioned Space [Adiabatic]
G1 R-22 Dbl Wall
Medium
646.0 sq. fl.
CONDIGAR
Unconditioned, attached garage
G1 R-19, 2x6 GAR
Medium
240.0 sq. ft.
2
Building Summary
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN_III [D]
Community: LEGACY PRAIRIE 104
LP104 [AS DESIGNED]
LEGACY PRAIRIE 104
FWall-fibrary List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
G1 R-13 BATT, R-3.0
15.12
G1 R-19, 2x6 GAR
16218
G1 R-19, R-3.0 2X6
20217
G1 R-22 Dhl Wall
18.407
Glazing
Name Library Type Wall Assignment
Basement Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.32, SHGC-.31
CONDIAMB
❑
0
❑
West
84.0 sq. R
FRONT U-.32, SHGG28
CONDIAMB
❑
0
❑
East
98.0 sq. fL
FRONT 2X6 U-.32, SHGG28
CONDIAMB 2x6
❑
0
❑
East
30.0 sq. fL
RIGHT SIDE U-.32, SHGG.31
CONDIAMB
❑
0
❑
North
102.0 sq. R.
SLIDER U-.32, SHGG.31
CONDIAMB
❑
0
❑
West
35.0 sq. ft
Glazing Library List
Name
U-.32, SHGC-28
U-.32, SHGC-.31
Skylight
Shgc
U #actor
0.28 ❑.324
0.31 0.320
9
Building Summary
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN_III [D]
Community: LEGACY PRAIRIE 104
LP104 [AS DESIGNED]
LEGACY PRAIRIE 104
kylight Library List I
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Opaque Door
Name Library Type Wall Assignmen,
FRONT Steel Door CONDIAMB
GARAGE Steel Door CONDIGAR
Assign ment
Opaque Door Library List
JL
Name U -factor
Steel Door 0.182
C-M
Energy Solutions
Inspection Status
Results are projected
r Surface Area Location
Ab sorpta n ce
0.9 0.75 Medium 20.0 sq- ft Exposed Exterior
0.9 0.75 Medium 18.0 sq- ft Exposed Exterior
Roof Insulation M=
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
ATTIC R-38 Blown, GR1 7,007 No Medium 1.007-0 sq. R Attic
Roof Insulation Library List
Name Has Radiant Barrier
'•0 .a l No
Whole House Infiltrati
Infiltration
6 ACH at 50 Pa
RAralue
38268
Blower -door tested 4
M
Building Summary
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN_III [D]
Community: LEGACY PRAIRIE 104
LP104 [AS DESIGNED]
LEGACY PRAIRIE 104
Mechanical Ventilation
Lighting
o Interior Fluorescent
Lighting
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
% Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting
Lighting
900 10 7DO
Onsite Generation
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
C-M,
Energy Solutions
Lighting
0
100
Building Summary
Property
Organization
Inspection Status
7249 BARKER ST
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
PSG (Single Speed)
Model: MERIDIAN_III (D)
95.5 AFUE
Heating Capacity [kBtulh]
Community: LEGACY PRAIRIE 104
Builder
No
EAE [kWh]
LENNAR HOMES
Equipment Type: CA13NA0361,m
LP104 (AS DESIGNED)
Fuel Type
Electric
LEGACY PRAIRIE 104
Forced Air
Motor Type
onditioning Equipment
Cooling Efficiency
13 SEER
Name
Library Type
Heating Percent Load Co(
Air conditioner (2)
Equipment Type: RE350*
CA13NA036
0%
C-M,
Energy Solutions
g Percent Load Hot Water
100%
0%
Fuel4red air 915SA4808OS17 100% 0% 0%
distribution (1)
Water Heating (3) RE350" 0% 0% 100%
1
Equipment Type: 915SA4808OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
Equipment Type: CA13NA0361,m
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
34.2
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Building Summary
Property
7249 BARKER ST
CARMEL, IN 46033
Model: MERIDIAN_III (D)
Community: LEGACY PRAIRIE 104
LP104 [AS DESIGNED]
LEGACY PRAIRIE 104
1butivn System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area [sq. ft.]
]uct Area [sq. ft_]
akage to Outdoors (CFM25)
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Ctm Per Watt
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
2330
2
3❑
3❑
471.8
174.8
139
279
Post -Construction
Yes
Conditioned Space
6❑
80
Attic (well vented; under insulation)
4❑
2❑
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
Organization Inspection Status
7249 BARKER ST
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: MERIDIAN_III [D]
No
Community: LEGACY PRAIRIE 104
Builder
Recirculation System Pipe Loop Length [ft]
LENNAR HOMES
LP104 [AS DESIGNED]
No
LEGACY PRAIRIE 104
ater Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
88
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
20
Drain Water Heat Recovery?
No
r
othes Dryer
elType Electric
f 2.62
ld Utilization Timer Controls
Clothes Washer
ff"W
Label Energy Rating
704 kWh/Year
Electric Rate
0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
1 mef
0.331
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
TSI Energy Solutions
,�