HomeMy WebLinkAboutGN - Morris 26 Sunrise Sewer Permitv, u I m uuiieyu, venue oum A moianapolls, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residential SANITARY SEWER PERMIT 999912605
Permit Type Final Subdivision
Sunrise on the Monon
Project WO
Project Name
Project Developer
Lift Station
Treatment Plant
Parcel Acreage
EDU in Gallons
ENG122015 Section Number
Sunrise on the Monon Section 1 Lot Number
Old Town Development L.L.0 Address Number
01 Carmel Creek Station Address 2
Carmel WWTP Street
Local Sewer Charge - District Contribution
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
Other Fees
Fees Due
Invoice Number
0.26 City
310
Zip Code
County
0.00
Builder
0.00
150.00
Phone Number
1908.00
Owner
0.00
Phone Number
0.00
2058.00
Occupant
Phone Number
1
26
1486
Windpump Way
Indianapolis
46280
Hamilton
Old Town Design Group
317-605-8796
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TriCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by Trico are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Main ID: SOM38SOM39
Grease Trap Slab Foundation YES
Grease Interceptor Crawl Space Manhole IDs USMH SOM-38 / SOM-39 DDSMM'HH
Grit Interceptor Basement Lid Elevation 802.81,p 802.63,/
Grinder Station First Floor Elevation
806.781 806.78/
Water Service City of Carmel Basement Elevation
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor 3.97 4.15 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Not Applicable
TnCo currently requires that an 181 inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a properry. Please review attached 1/1 Permit.
Manholes shall remain accessible at ail times. Buried manholes will be corrected by the Developer/Owner.
V The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sew ain to structure.
The terms of the conditional permit, if any, are listed below. `4 P�G`�N wFRGT'A
Plans have been submitted.
All fees have been paid.
No certificate of insurance required. . TriCo
No additional permits required.
No manhole core permit required. o'
The facility is not classified as a FOG facility.
0
(Notes)
V.eoe `SQA,
a
By signing below, I attest that I am fa 'liar )th the District's pe " ations and agree to accept responsibility for all ork done under this permt.
Builder/ Owner Signature /` W/ Phone Number
Printed Name /Jlil C' 1 7Larvi h
Approved By 4 a ,
Rya an, isNdEngneer 04/01/2019
Permit is valid f r ON -YEAR from the date issued. Permit valid only with TnCo seal in red ink.