Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 5782-10900} Address{\C256;3307 SHELBORNE WOODS PARKWAY}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46032} Community{\Fsimplex|c0;\C256;5782}{\C256;WOODS AT SHELBORNE}{\C256;5782-10900}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR3S - IN1} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxt20,28;LIVE LOADS:\P\pt2,r28; Sleeping ___ PSF\P Non-Sleeping ___ PSF\P Ext. Decks & Stairs ___ PSF\P\ptr28;DEAD LOAD: ___ PSF\P\pt2,r27; Guard Rail & Handrail ___ LB \P\pt2,r28; Guard Infill Components ___ PSF\P\ptr28;WIND SPEED: ___ MPH\PROOF LIVE LOAD: ___ PSF\PSNOW LOAD: ___ PSF\PLATERAL LOAD: ___ PCF \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends A0.01 Foundation - Basement A1.01 Finished Basement Floor Plan A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.01 Building Section A2.02 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan U1.01 Finished Basement Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt Cabinets at LaundryOpt. Additional Cabinets at Pulte Planning CenterOpt. Base Cabinet at PPCBath 7 OptionBedroom 7 OptionBeverage Center OptionOpt. Built in Kitchen 2 Coffered Ceiling @ Gathering RoomElevation HR3S - IN1No OptionFinished Basement OptionBasement FoundationOpt. Traditional Fireplace at Casual LivingTraditional Fireplace at Gathering Room3 Car Side Load GarageGathering Room ExtensionLaundry 2 Option Masonry Wrap - Sides and RearOwners Suite - Additional WindowsOwner's Bath 6Shower Option at Bath 3Opt Sink at LaundryIndianaOpt. Fireplace at SunroomOpt SunroomOpt Tray Ceiling at Owners SuiteOpt Basement Window Well - Location 2Opt Basement Window Well - Location 4 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 1st Floor - Sunroom & 4' Gath Rm Ext. 2nd Floor Basement - Finished Basement - Finished - Sunroom & Gath Ext. 1981 SF 207 SF 2169 SF 1509 SF 201 SF 6068 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Storage & Mech Basement - Storage & Mech 136 SF 264 SF 400 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Front Porch Uncovered Rear Patio 664 SF 60 SF 164 SF 889 SF 7356 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Truman 1702.300Home for * Market Home *, 5782-109003307 Shelborne Woods Parkway, Carmel, IN 46032CC.01 04/03/19 Adam Schriner