Loading...
HomeMy WebLinkAboutMERIDIAN D TRUSS SEALS 107Re: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI-1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek’s customer’s file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Timberland Home Center-Brazil, IN. Liu, Xuegang MERIDIAN D Pages or sheets covered by this seal: I24811461 thru I24811471 My license renewal date for the state of Indiana is July 31, 2016. 1500312 14515 North Outer Forty Drive Suite 300 Chesterfield, MO 63017-5746 314-434-1200 MiTek USA, Inc. September 1,2015 Job 1500312 Truss A Truss Type MOD. QUEEN Qty 3 Ply 1 MERIDIAN D Job Reference (optional) I24811461 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:29 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:zrnD?hJQ8196XrjEltqqBiyi1AM-Nm75XV4uacpjFz6fFZpVWpNRmJZa3IaYRzRPIxyi08i Scale = 1:75.0 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 18 19 6x6 3x6 3x6 5x6 3x6 3x4 2x4 3x4 3x4 3x8 3x4 4x6 3x6 2x8 3x6 10-1-1 10-1-1 20-0-0 9-10-15 29-10-15 9-10-15 38-0-0 8-1-1 -0-9-12 0-9-12 6-9-6 6-9-6 13-4-11 6-7-5 20-0-0 6-7-5 26-7-5 6-7-5 33-2-10 6-7-5 38-0-0 4-9-6 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.77 0.93 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.26 -0.75 0.15 (loc) 2-17 2-17 12 l/defl >999 >606 n/a L/d 240 180 n/a PLATES MT20 Weight: 162 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-15,6-15,7-15: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 2-17. WEBS 1 Row at midpt 5-15, 7-15, 9-12 spacing of 18-0-0 oc. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)2=1566/0-3-8, 12=1566/0-3-8 Max Horz 2=-3(LC 5) Max Uplift 2=-231(LC 5), 12=-230(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2702/389, 3-4=-2448/342, 4-5=-2286/375, 5-18=-1675/312, 6-18=-1578/344, 6-19=-1578/345, 7-19=-1676/313, 7-8=-2002/333, 8-9=-2085/301 BOT CHORD 2-17=-253/2321, 16-17=-125/1897, 15-16=-125/1897, 14-15=-109/1743, 13-14=-109/1743, 12-13=-171/1708 WEBS 3-17=-307/181, 5-17=-7/543, 5-15=-782/206, 6-15=-163/1053, 7-15=-579/183, 7-13=0/253, 9-12=-2041/250 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 231 lb uplift at joint 2 and 230 lb uplift at joint 12. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss A1 Truss Type MOD. QUEEN Qty 2 Ply 1 MERIDIAN D Job Reference (optional) I24811462 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:30 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:R2LbC1K2vKHz9?IQJaM3jvyi1AL-ryhTlr5WLvxas7hspHKk31wdZjuBolqifdByqNyi08h Scale = 1:74.4 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 17 18 6x6 3x6 3x6 5x6 3x6 3x4 2x4 3x4 3x4 3x8 3x4 4x6 3x6 2x8 3x6 10-1-1 10-1-1 20-0-0 9-10-15 29-10-15 9-10-15 38-0-0 8-1-1 6-9-6 6-9-6 13-4-11 6-7-5 20-0-0 6-7-5 26-7-5 6-7-5 33-2-10 6-7-5 38-0-0 4-9-6 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [1:Edge,0-3-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.77 0.97 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.78 0.15 (loc) 1-16 1-16 11 l/defl >999 >582 n/a L/d 240 180 n/a PLATES MT20 Weight: 161 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 4-14,5-14,6-14: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 1-16. WEBS 1 Row at midpt 4-14, 6-14, 8-11 spacing of 18-0-0 oc. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1508/0-3-8, 11=1567/0-3-8 Max Horz 1=-13(LC 5) Max Uplift 1=-190(LC 5), 11=-231(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2709/395, 2-3=-2453/346, 3-4=-2291/379, 4-17=-1676/313, 5-17=-1580/345, 5-18=-1580/346, 6-18=-1678/314, 6-7=-2003/334, 7-8=-2086/301 BOT CHORD 1-16=-261/2328, 15-16=-126/1900, 14-15=-126/1900, 13-14=-110/1744, 12-13=-110/1744, 11-12=-171/1709 WEBS 2-16=-311/188, 4-16=-10/545, 4-14=-784/206, 5-14=-164/1054, 6-14=-572/183, 6-12=0/253, 8-11=-2042/251 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 190 lb uplift at joint 1 and 231 lb uplift at joint 11. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss AGE Truss Type GABLE Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811463 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:31 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:vEv_QNKggePqm9tctHtIG7yi1AK-J8FryB686D3RUHG2N_szbESx07S5XI5ruHwWMqyi08g Scale = 1:72.0 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3132 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 333x8 3x6 5x6 3x6 3x6 5x6 38-0-0 38-0-0 20-0-0 20-0-0 38-0-0 18-0-0 38-9-12 0-9-12 0-6-610-6-61-6-66.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge], [54:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.09 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 32 32 33 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 264 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 16-48,15-49,14-50,17-47,18-46: 2x4 SPF No.2 WEDGE Left: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 16-48, 15-49, 14-50, 13-51, 17-47, 18-46, 19-45 spacing of 20-0-0 oc. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 38-0-0. (lb) - Max Horz 1=-13(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35 except 34=-135(LC 5) Max Grav All reactions 250 lb or less at joint(s) 1, 33, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 47, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35, 34 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-14=-29/260, 14-15=-31/290, 15-16=-33/302, 16-17=-31/302, 17-18=-29/290, 18-19=-28/260 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 46, 45, 44, 42, 41, 40, 39, 38, 37, 36, 35 except (jt=lb) 34=135. 11) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss AGE Truss Type GABLE Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811463 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:31 2015 Page 2 Timberland Lumber Company, Indianapolis, IN 46222 ID:vEv_QNKggePqm9tctHtIG7yi1AK-J8FryB686D3RUHG2N_szbESx07S5XI5ruHwWMqyi08g NOTES- 12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. Job 1500312 Truss AT Truss Type SPECIAL Qty 6 Ply 1 MERIDIAN D Job Reference (optional) I24811464 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:rd1kr3MwCFfY0S0?_ivmLYyi1AI-nLoE9X7mtXBI6RrExiNC8S?wOXexGb5?7xg3uGyi08f Scale = 1:77.7 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 19 20 8x8 5x9 3x6 2x8 2x4 4x9 2x8 6x12 2x4 2x4 3x6 2x4 5x9 3x4 3x4 4x6 3x6 2x8 2-3-8 2-3-8 8-2-0 5-10-8 12-10-8 4-8-8 20-0-0 7-1-8 29-5-3 9-5-3 38-0-0 8-6-13 2-3-8 2-3-8 8-2-0 5-10-8 12-10-8 4-8-8 20-0-0 7-1-8 25-10-13 5-10-13 31-9-11 5-10-13 38-0-0 6-2-5 38-11-4 0-11-4 0-6-610-6-61-6-61-0-06.00 12 Plate Offsets (X,Y)-- [2:0-8-4,0-0-0], [3:0-3-8,Edge], [16:0-6-0,0-2-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.94 0.76 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.29 -0.74 0.38 (loc) 2-17 2-17 11 l/defl >999 >612 n/a L/d 240 180 n/a PLATES MT20 Weight: 194 lb FT = 0% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF-S 1650F 1.6E, 1-3: 2x8 SP 2250F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 1-18,2-18: 2x4 SPF Stud/No.3, 2-16: 2x4 SPF-S 1650F 1.6E WEBS 2x4 SPF Stud/No.3 *Except* 5-16,5-14,6-14: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-9-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 8-11 spacing of 18-0-0 oc. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=1509/0-3-8, 11=1573/0-3-8 Max Horz 1=-21(LC 5) Max Uplift 1=-189(LC 5), 11=-237(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-565/111, 2-3=-3350/421, 3-4=-2630/405, 4-19=-2639/510, 5-19=-2541/537, 5-20=-1576/351, 6-20=-1660/323, 6-7=-1938/357, 7-8=-2083/328, 8-9=-283/135, 9-11=-342/163 BOT CHORD 2-17=-280/3097, 16-17=-276/3105, 13-14=-91/1704, 12-13=-91/1704, 11-12=-158/1792 WEBS 4-16=-439/200, 3-17=0/279, 3-16=-977/148, 14-16=0/1365, 5-16=-281/1500, 5-14=-28/456, 6-14=-567/172, 6-12=0/296, 8-11=-1991/200 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=189, 11=237. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V1 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811465 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:32 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:rd1kr3MwCFfY0S0?_ivmLYyi1AI-nLoE9X7mtXBI6RrExiNC8S?8hXprGmH?7xg3uGyi08f Scale = 1:7.7 1 2 3 2x4 3x4 2x4 2-6-11 2-6-11 1-3-6 1-3-6 2-6-11 1-3-6 0-11-89.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.02 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=67/2-6-11, 3=67/2-6-11 Max Uplift 1=-8(LC 3), 3=-8(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V2 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811466 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:o?8UGlOAjtvGFmAN67xEQzyi1AG-FXMcNt8OeqJ9jbPRUPuRhfYHZx7X?DA8MbPdRiyi08e Scale = 1:14.6 1 2 3 4 2x4 4x6 2x4 2x4 5-2-11 5-2-11 2-7-6 2-7-6 5-2-11 2-7-6 1-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.14 0.09 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=96/5-2-11, 3=96/5-2-11, 4=156/5-2-11 Max Uplift 1=-25(LC 5), 3=-25(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V3 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811467 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:33 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:GCitT5OpUA17twlagrTTzAyi1AF-FXMcNt8OeqJ9jbPRUPuRhfYE?x5E?Dt8MbPdRiyi08e Scale = 1:21.1 1 2 3 4 5 6 2x4 4x6 2x4 2x4 7-10-11 7-10-11 3-11-6 3-11-6 7-10-11 3-11-6 2-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.37 0.24 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=155/7-10-11, 3=155/7-10-11, 4=251/7-10-11 Max Uplift 1=-37(LC 5), 3=-37(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V4 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811468 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:34 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:kOGFgRPRFU9zU4KmDY_iWOyi1AE-jjw_aD80P8R0Ll_d26PgDt4P5KQAkfaIaF9Az8yi08d Scale = 1:26.4 1 2 3 4 5 6 2x8 4x6 2x8 2x4 10-6-11 10-6-11 5-3-6 5-3-6 10-6-11 5-3-6 3-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.35 0.26 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)1=197/10-6-11, 3=197/10-6-11, 4=381/10-6-11 Max Uplift 1=-33(LC 5), 3=-33(LC 5), 4=-4(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V5 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811469 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:34 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:CaqdumQ30oHq6DvynFVx2byi1AD-jjw_aD80P8R0Ll_d26PgDt4POKTkkfXIaF9Az8yi08d Scale = 1:32.3 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 13-2-11 13-2-11 6-7-6 6-7-6 13-2-11 6-7-6 4-11-89.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.33 0.10 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 13-2-11. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=256(LC 1), 8=306(LC 2), 6=306(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss V6 Truss Type VALLEY Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811470 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:35 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:gnO?56Rhn5PhkNU9Lz0Abpyi1AC-CwUMoZ9f9SZtzuZpcqwvm4ddgkowT6LRpvujVbyi08c Scale = 1:38.9 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 15-10-11 15-10-11 7-11-6 7-11-6 15-10-11 7-11-6 5-11-89.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.17 0.16 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 15-10-11. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 8 except 6=-101(LC 5) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=365(LC 2), 6=364(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-276/146, 4-6=-277/146 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 6=101. 7) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 Job 1500312 Truss VG7 Truss Type GABLE Qty 1 Ply 1 MERIDIAN D Job Reference (optional) I24811471 7.630 s Jul 28 2015 MiTek Industries, Inc. Tue Sep 01 11:35:35 2015 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:8zyNJSRJYPYYLX3LvgXP70yi1AB-CwUMoZ9f9SZtzuZpcqwvm4dexkppT6zRpvujVbyi08c Scale = 1:39.8 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 22 23 3x4 4x6 3x4 3x4 17-0-3 17-0-3 8-6-2 8-6-2 17-0-3 8-6-2 6-4-99.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB (Matrix) 0.08 0.11 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 11-16: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 17-0-3. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 18, 19, 20, 21, 15, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 17, 18, 19, 20, 21, 15, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-05; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 19, 20, 21, 15, 14, 13, 12. 8) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult 14515 N. Outer Forty, Suite #300 Chesterfield, MO 63017 ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 02/16/2015 BEFORE USE. September 1,2015 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 02/16/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBS