Loading...
HomeMy WebLinkAboutE30-0ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT3 ST - 20 AMP, 125VAC, SAFETY TYPE S - 20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE WP - 20 AMP, 125VAC, WEATHERPROOF TYPE HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG - 20 AMP, 125VAC, ISOLATED GROUND TYPE NONE - 20 AMP, 125VAC ELECTRICAL RECEPTACLES DUPLEX RECEPTACLE - NORMAL POWER CIRCUIT DESCRIPTIONSYMBOL DUPLEX GFCI RECEPTACLE - NORMAL POWER CIRCUIT QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT QUADRAPLEX GFCI RECEPTACLE -NORMAL POWER CIRCUIT SIMPLEX RECEPTACLE - NORMAL POWER CIRCUIT SPECIAL RECEPTACLE - NORMAL POWER CIRCUIT DUPLEX RECEPTACLE - TOP SWITCHED "X" DENOTES AS FOLLOWS: CEILING DUPLEX RECEPTACLE - NORMAL POWER CIRCUIT CEILING QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX DUPLEX RECEPTACLE - NORMAL POWER CIRCUIT FLOOR BOX QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX POWER AND TELECOM FLOOR BOX BLANK MULTI-OUTLET ASSEMBLY (POWER AND/OR TELECOM) ELECTRICAL SWITCHES DESCRIPTION SYMBOL TOGGLE SWITCH - 20 AMP, 120/277VAC TOGGLE SWITCH - 3 WAY 4 TOGGLE SWITCH - 4 WAY K TOGGLE SWITCH - KEY OPERATED T TOGGLE SWITCH - HORSE POWER RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION P TOGGLE SWITCH - PILOT LIGHT D DIMMER SWITCH - 20 AMP, 120/277VAC D DIMMER SWITCH - 3 WAY 3 4 D DIMMER SWITCH - 4 WAY OC1 WALL OCCUPANCY SENSOR - 1 BUTTON CONTROL OC2 WALL OCCUPANCY SENSOR - 2 BUTTON CONTROL OC3 WALL OCCUPANCY SENSOR - DUAL RELAY FOR EXHAUST FAN CONTROL OC CEILING OCCUPANCY SENSOR VS1 WALL VACANCY SENSOR - 1 BUTTON CONTROL VS2 WALL VACANCY SENSOR - 2 BUTTON CONTROL LC LOW VOLTAGE LIGHTING CONTROLLER T 0 - 3 HOUR TIMER SWITCH - 20 AMP, 120/277VAC INFORMATION SYSTEMS DESCRIPTIONSYMBOL VOICE AND DATA ONLY OUTLET WAP - WIRELESS ACCESS POINT FLOOR BOX - VOICE AND DATA CEILING - VOICE AND DATA TELECOMMUNICATIONS EQUIPMENT RACK X R - ROUGH-IN ONLY # -QUANTITY OF JACK(S) AND CABLE(S) "X" DENOTES AS FOLLOWS: NEUTRAL GROUND RACEWAY SYSTEM DESCRIPTION PHASE CONDUCTORS SYMBOL LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK LINE SYMBOLS HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED J JUNCTION OR PULL BOX PUSHBUTTON OR PUSH PLATE PAD MOUNTED TRANSFORMER BRANCH PANELBOARD - SURFACE MOUNT COMBINATION MOTOR CONTROLLER / DISCONNECT DISCONNECT SWITCH - NON-FUSED MOTOR CONTROLLER DISCONNECT SWITCH - FUSED MOTOR ("X" DENOTES HORSEPOWER) GROUND CONNECTION ELECTRIC THERMOSTATT DESCRIPTION MOLDED CASE CIRCUIT BREAKER ELECTRICAL EQUIPMENT SYMBOL GROUND POINT GROUND ROD X PC PHOTO CELL SUSPENDED TRANSFORMER DISTRIBUTION PANELBOARD BRANCH PANELBOARD - RECESSED MOUNT TELECOM TERMINAL BOARD GROUND BAR TV AV TV SYSTEM OUTLET AUDIO/VISUAL CONTROLLER CLOCK SYSTEM OUTLETC M M MICROPHONE INPUT RECEPTACLE - WALL MOUNTED SPEAKER - WALL MOUNTED SPEAKER - CEILING MOUNTED VOLUME CONTROL MICROPHONE INPUT RECEPTACLE - CEILING MOUNTED S S V WAP X X RECEPTACLE ABOVE COUNTERTOP AT +2" ABOVE BACKSPLASH TO BOTTOM OF DEVICE. COORDINATE WITH CASEWORK TO BE INSTALLED. RECEPTACLE INSTALLED BELOW COUNTERTOP AT +18" A.F.F. COORDINATE WITH CASEWORK TO BE INSTALLED. X RECEPTACLE LEGEND FXX FEEDER SIZE. (REFER TO FEEDER SCHEDULE FOR ADDITIONAL INFORMATION 1. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN, HVAC EQUIPMENT, DUCTWORK, PIPING AND SUPPORTS. 2. ELECTRICAL CONTRACTOR SHALL VERIFY THE CONDITIONS AT THE PROJECT SITE BEFORE SUBMITTING COST PROPOSAL. 3. ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS TO FAMILIARIZE HIMSELF WITH EXTENT OF THE WORK. 4. ALL WORK SHALL CONFORM TO OR EXCEED THE MINIMUM REQUIREMENTS OF THE CURRENT ANSI / NFPA 70 WITH STATE AMENDMENTS, ENERGY CODE, ANSI / IEEE C2 AND ALL FEDERAL, STATE, LOCAL AND MUNICIPAL CODES AND ORDINANCES. THE ELECTRICAL SUBCONTRACTOR SHALL COMPLY WITH THE DIRECTIONS OF ALL AUTHORITIES HAVING JURISDICTION. 5. INSTALL WORK USING PROCEDURES DEFINES IN NECA STANDARDS OF INSTALLATION. ALL WORK SHALL PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. 6. REFER TO THE ARCHITECTURAL DRAWINGS FOR CEILING WORK BY THE GENERAL CONTRACTOR. COORDINATE ALL ELECTRICAL WORK. 7. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL FLOOR, WALL, AND CEILING PENETRATIONS TO COMPLETE HIS WORK. PROVIDE PROPER FIRESTOPPING/ FIRE SAFEING FOR ALL PENETRATIONS MADE. PROVIDE APPROPRIATE SEALANT (I.E. FIRESAFEING) TO MAINTAIN CONSTRUCTION INTEGRITY FOR ANY PENETRATIONS THROUGH FLOORS, STRUCTURAL CEILING, AND FIRE WALLS. REFER TO THE ARCHITECTURAL SPECIFICATIONS FOR REQUIREMENTS. 8. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES TO ENSURE EFFECTIVE AND EFFICIENT OVERALL INSTALLATION. 9. THE LOCATION OF RECEPTACLES, PHONE / DATA JACKS, AND ROOM EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. FINAL LOCATIONS WILL BE DETERMINED WITH THE ARCHITECT DURING THE CONSTRUCTION PHASE. 10. ALL EQUIPMENT SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING. 11. PHYSICAL SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. COORDINATE ELECTRICAL WORK FOR THIS EQUIPMENT WITH THE OTHER TRADES. 12. ALL BRANCH CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL CONDUCTORS. DO NOT COMBINE NEUTRAL CONDUCTORS. 13. ALL FEEDER NEUTRAL / GROUNDED CONDUCTORS SHALL BE CONSIDERED CURRENT CARRYING. DERATE MULTIPLE CONDUCTORS IN A RACEWAY ACCORDINGLY WITH NEC TABLES. 14. INSTALL ALL CONDUITS, RACEWAYS, AND CABLE TRAY FOR MAXIMUM HEAD CLEARANCE IN MECHANICAL AREAS. 15. WIRING SHALL BE INSTALLED ABOVE ACCESSIBLE CEILINGS AND WITHIN WALL CAVITIES WHERE POSSIBLE. 16. WIRING THAT IS TO BE INSTALLED IN AREAS WHERE THERE ARE NO CEILINGS SHALL BE INSTALLED EXPOSED. THIS WIRING SHALL BE INSTALLED NEATLY AND AT RIGHT ANGLES TO STRUCTURE. WIRING SHALL BE INDEPENDENTLY SUPPORTED AS REQUIRED. WIRING SHALL NOT LAY OVER OTHER TRADES. 17. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN STORING OF ELECTRICAL EQUIPMENT AND MATERIAL. 18. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED FOR ELECTRICAL WORK. ALL CUTTING, PATCHING, REPAIRING, REPLACEMENT AND REFINISHING, SHALL MATCH THE GENERAL CONSTRUCTION AS NEARLY AS POSSIBLE. REFER TO THE ARCHITECTURAL SPECIFICATIONS FOR REQUIREMENTS. 19. BLOCKING: ELECTRICAL CONTRACTOR SHALL PROVIDE ALL IN-WALL BLOCKING REQUIRED TO SUPPORT ELECTRICAL EQUIPMENT. GENERAL NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED. MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITY AS REQUIRED. CEILING AND WALLMOUNTED SENSORS SHALL BE DUAL-TECHNOLOGY TYPE. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN ROOM/AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE - MANUAL ON/AUTO OFF. ACCEPTABLE MANUFACTURERS ARE: HUBBELL, SENSOR SWITCH, LEVITON, LIGHTOLIER, WATTSTOPPER. 2. ALL LIGHT FIXTURES SHOWN WITH EMERGENCY BATTERY BALLASTS OR BACKUP SHALL HAVE UNSWITCHED "HOT" WIRE INSTALLED TO FIXTURE FROM INDICATED LIGHTING CIRCUIT. GENERAL LIGHTING NOTES (APPLY TO ALL ELECTRICAL SHEETS) GENERAL WIRING DEVICE NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. AT LOCATIONS WITH TWO OR MORE WALL SWITCHES, ALL SWITCHES SHALL BE INSTALLED GANGED IN A COMMON SWITCH BOX. 2. ALL RECEPTACLES SHALL BE TAMPER-RESISTANT TYPE 3. RECEPTACLE LOCATIONS IN ALL UNITS SHALL COMPLY WITH NATIONAL ELECTRICAL CODE REQUIREMENTS AND MEET ALL SPACING REQUIREMENTS. ELECTRICAL CONTRACTOR SHALL ADJUST LAYOUT SHOWN OR ADD RECEPTACLES AS REQUIRED TO COMPLY WITH APPLICABLE CODES. TELEPHONE AND DATA SYSTEMS NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUITS AND OTHER RACEWAYS REQUIRED FOR TELEPHONE AND DATA SYSTEMS. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TELEPHONE AND DATA SYSTEMS WIRING AND CABLING REQUIRED WITHIN EACH UNIT AND ALL OTHER WIRING AND CABLING INDICATED ON THE DRAWINGS. TELEPHONE AND DATA WIRING WITHIN UNITS MAY BE RUN WITHOUT CONDUIT OR OTHER RACEWAY. 3. TELEPHONE AND DATA SYSTEMS WIRING AND CABLING FOR UTILITY SERVICES TO THE PROJECT BUILDINGS WILL BE PROVIDE BY THE UTILITY SERVICE PROVIDERS UNLESS OTHERWISE INDICATED. TELEVISION/CATV SYSTEMS NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUITS AND OTHER RACEWAYS INDICATED AND REQUIRED FOR TELEVISION/CATV SYSTEMS. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TELEVISION/CATV WIRING AND CABLING REQUIRED WITHIN EACH UNIT AND OTHER WIRING AND CABLING INDICATED ON THE DRAWINGS. TELEVISION/CATV WIRING WITHIN UNITS MAY BE RUN WITHOUT CONDUIT OR OTHER RACEWAY. 3. TELEVISION/CATV SYSTEMS WIRING AND CABLING FOR UTILITY SERVICES TO THE PROJECT BUILDINGS WILL BE PROVIDE BY THE UTILITY SERVICE PROVIDER UNLESS OTHERWISE INDICATED. VOLTAGE DROP NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. VOLTAGE DROP IS NOT SHOWN ON THE DRAWINGS. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING ALL FEEDER AND BRANCH CIRCUIT CONDUCTOR SIZES TO COMPLY THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL CODES VOLTAGE DROP REQUIREMENTS. 2. THE ELECTRICAL CONTRACTOR SHALL UPSIZE FEEDER AND BRANCH CIRCUIT CONDUCTORS AS REQUIRED BASED ON ACTUAL INSTALLED CONDUCTOR LENGHTS. 3. VOLTAGE DROP ON FEEDERS SHALL NOT EXCEED 2 PERCENT. 4. VOLTAGE DROP ON BRANCH CIRCUITS SHALL NOT EXCEED 3 PERCENT. MECHANICAL EQUIPMENT DISCONNECT NOTES (APPLY TO ALL ELECTRICAL SHEETS) 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE MAXIMUM OVERCURRENT PROTECTION (MCOP) VALUE FOR MECHANICAL EQUIPMENT WHERE THE EQUIPMENT DISCONNECT IS PROVIDED BY THE EQUIPMENT MANUFACTURER. 2. THE ELECTRICAL CONTRACTOR SHALL ADJUST THE EQUIPMENT CIRCUIT CONDUCTOR AND CIRCUIT BREAKER SIZES AS REQUIRED TO NOT EXCEED THE EQUIPMENT MCOP. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL REQUIREMENTS PRIOR TO ORDERING AND INSTALLING PANELBOARDS, CONDUCTORS, AND CONDUITS. ARC FLASH STUDY 1. THE CONTRACTOR SHALL INCLUDE IN THE BID A COMPLETE ARC FLASH AND SHORT CIRCUIT STUDY FOR THE PROJECT PERFORMED BY A LICENSED ENGINEER. 2. ALL EQUIPMENT SHORT CIRCUIT RATINGS SHALL BE ADJUSTED IN ACCORDANCE WITH THE SHORT CIRCUIT STUDY PRIOR TO ORDERING EQUIPMENT. 3. PROVIDE ARC FLASH LABELS ON ALL EQUIPMENT / PANELBOARDS. ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.790 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. CERTIFICATION: CHECKED:DRAWN: C:\Users\jfakes\Documents\Custom Living Monon on Main Town Homes GEG R18_jfakes.rvt 4/5/2019 3:09:51 PM E30-0COPYRIGHT 2018 ELECTRICAL SYMBOLS AND ABBREVIATIONS Monon & Main Brownstones Monon & Main St., Carmel INJAWJAW Monon and Main Brownstone Interior Remodel –Unit 30 04/05/2019 Lot 30 -ERNST RESIDENCE# REVISION Date 05/02/19 Mike Sheeks