Loading...
HomeMy WebLinkAboutP30-4W D7 8 A B 2" V 2" V 2" V 2" V 2" V 2" V 2" S 2" V 2" V 2" S 2" S 3" S 2" S 2" S 2" S 2" S3" S 2" S 2" S 2" V 3" S 3" S 3" S 3" S FLOOR DRAIN ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.790 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. CERTIFICATION: CHECKED: DRAWN: C:\Users\wmaltby\Documents\Custom Living Monon on Main Town Homes GEG R18_wmaltby@genesis-engineering.com.rvt 4/4/2019 9:15:52 AM P30-4COPYRIGHT 2018 PLUMBING THIRD FLOOR PLANMonon & Main Brownstones Monon & Main St., Carmel INWAMWAM Monon and Main Brownstone Interior Remodel –Unit 30 04/05/2019 Lot 30 -ERNST RESIDENCE PLAN NOTES 1 DO NOT ROUTE ANY WIRING, PIPING, DUCTWORK, ETC THROUGH LIFT SHAFT. 2 PROVIDE TO 3" STEEL PIPE BULLARDS TO PROTECT UTILITY GAS METER FROM ACCIDENTAL DAMAGE. 3 UTILITY GAS MAIN, COORDIANTE BOLLARD LOCATION WITH MAIN 4 WATER COMPANY METER PIT WITH TRAFIC RATED LID 5 REFER TO SITE PLANS FOR CONTINUATION OF 4"S MAIN. 6 REFER TO SITE PLANS FOR CONTINUATION OF 4" STORM MAIN 7 INSTALLATION OF WATER MAIN SHALL BE PER UTILITY REQURIEMENTS. PROTECT FROM DAMAGE DURING CONSTRUCTION. 8 INSTALLATION OF SANITARY MAIN SHALL BE PER STATE AND LOCAL CODE. PROTECT FROM DAMAGE DURING CONSTRUCTION. 9 INSTALLATION OF DEWATERING MAIN SHALL BE PER STATE AND LOCAL CODES. PROTECT FROM DAMAGE DURING CONSTRUCTION 10 S SLEEVE THROUGH FOUNDATION WALL AND CAP FOR FUTURE. 11 3/4" WATER MAIN FIELD COORDIANTE LOCATION INTO STRUCTURE. 12 DEWATERING PIT, DESIGNED FOR RADON MITIGATION SYSTEM 13 PASSIVE RADON VENT, DESIGNED ROUTED AND INSTALLED BY OTHERS. 14 ALL VENT PIPE SHALL BE ROUTED THROUGH THE FLOOR SYSTEM. 15 6"FP MAIN, PROTECT FROM DAMAGE DURING CONSTRUCTION. 16 FP MAIN, PROVIDE UNIT ISOLATION VALVE, FLOW AND TAMPER SWITCH AND ALL OTHER REUQIRED ACCESSORIES TO CREATE A COMPLETE, CODE COMPLIANT AND OPERATIONAL INSTALLATION. 17 2" STORM DRAIN, CONNECT TO SITE STORM DRAINAGE SYSTEM 18 2" STORM DRAIN UP TO POLISHED BRASS AREA DRAIN 19 PROVIDE NATURAL GAS PRESSURE REDUCING 2 PSIG TO 10"WC, VALVE AND ISOLATION VALVE TO SERVE NATURAL GAS HEADER. CONTRACTOR SHALL FIELD COORDIANTE AND FIELD ROUTE ALL NATURAL GAS PIPES FROM THIS MANIFOLD TO ALL GAS FIRED APPLIANCES. MINIMUM PIPE DIAMETER SHALL BE 3/4" TO ANY APPLIANCE. PROVIDE ISOALTION VALVE AND ALL OTHER REUQIRED ACCESSORIES IN ORDER TO MAKE FINAL CONNECTDIONS TO ALL NATURAL GAS FIED APPLIANCES, FIRE PLACES, GRILLES. 20 DOMESTIC WATER HEATER - 2"V, 2" INTAKE, TERMINATE PER MANUFACTURE REQUIREMENTS. TEMINATE VENT PER CODE MINIMUM DISTANCES 21 CONTRACTOR SHALL COORDIANTE THE INSTALLATION OF ALL EQUIPMENT WITH CUSTOM LIVING NO EQUIPMENT SHALL BE INSTALLED WITHOUT FULL COORDIANTION. 22 PRIOR TO INSTALLATION OF ANY PLUMBING PIPING SYSTEMS, THE CONTRACTOR SHALL COORDIANTE THE PIPE ROUTING WITH ALL OTHER TRADES, INCLUDING CUSTOM LIVING. NO BULK HEADS WILL BE PROVIDED TO CONCEAL PIPING SYSTEMS WITHIN THE STRUCTIRE. 23 ALL DOMESTIC WATER SHALL BE INSULATED TO PROTECT FROM FREEZING. THE CONTRACTOR SHALL INSULATE PIPE WITH ELASTOMERIC INSULATION AND ALSO PROVIDE FIBERGLASS BAT INSULATION UNDER ALL WASTE AND VENT PIPING TO FURTHER ENSURE THAT PIPE DO NOT FREEZE IN THE EVENT THAT THE GARAGE DOORS BECOME DAMAGED. 24 RADON VENT PATHWAY, RADON VENT PROVIDED AND INSTALLED BY OTHERS. 25 CONTRACTOR SHALL PROVIDE WASHER BOX WITIH 2" DRAIN, WATER HAMMER ARRESTORS AND ISOLATION VALVES WITH SINGLE HANDLE OPERATION. COORDIANTE THE EXACT LOCATION WITH THE EQUIPMENT TO BE INSTALLED. PROVIDE DRAIN PAN UNDER CLOTHES WASHER AND PIPE COMPLETE TO THE SANITARY DRAINAGE SYSTEM. PROVIDE FOOD GRADE MINERAL OIL TO SEAL THE PIPE TRAP. 26 PROVIDE FREEZE PROOF EXTERIOR HOSE VALVE, COORDIANTE EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. 27 PROVIDE 1/2" NATRUAL GAS CONNECTION WITH ISOLATION VALVE AND PLUG (FOR FUTURE CONNECTION) COORDIANTE THE EXACT LOCATION WITH CUSTOM LIVING. 28 FIELD ROUTE 1/2"NG FROM NATURALA GAS HEADER TO FIRE PLACE AND CONNECT 1/2"NG TO NATURAL GAS FIRE PLACE. INSTALL PER CODE AND MANUFACTURES RECOMMENDATIONS. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE NATURAL GAS SHUT-OFF VALVE WITH CUSTOM LIVING. 29 ROUTE 1/2"NG FROM NATURAL GAS HEADER TO STOVE/OVEN. INSTALL PER CODE AND EQUIPMENT MANUFACTURE REQURIEMENTS. COORDIANTE WITH CUSTOM LIVING THE EXACT REQUIREMENTS FOR THE APPLIANCE. 30 ROUTE 1/2"NG FROM HEADER TO CLOTHES DRYER. CONNECT PER CODE AND MANUFACTURES REQUIREMENTS. COORDIANTE WITH CUSTOM LIVING THE EXACT MODEL OF EQUIPMENT TO BE INSTALLED. 31 ROUTE 3/4"NG FROM HEADER AND CONNECT PER CODE AND MANUFACTURES REQUIREMENTS. 32 DOMESTIC WATER PIPE ROUTED THROUGH PIPE SLEEVE ACROSS SANITARY MAIN 33 ROUTE CONDENSATE DRAIN AND FURNACE CONDENSATE TO FLOOR DRIAN / OPEN SITE DRAIN. PROVIDE DRAIN PAN UNDER ALL MECHANICAL EQUIPMENT AND ROUTE DRAIN TO FLOOR DRAIN. COORDIANE THE INSTALLATION OF THE FURNACE WITH THE DRAIN. NO EQUIPMENT OR PIPE SHALL BE INSTALLED WITHOUT COORDIANTION WITH CUSTOM LIVING. 34 ROUTE DOMESTIC HOT AND COLD WATER FROM RISERS AT THIS LOCATION TO SERVE ALL PLUMBING FIXTURES. NO WATER PIPE SHALL BE ROUTED IN ANY UN-HEATED SPACE WITHOUT COORDIANTION WTIH CUSTOM LIVING. 35 PROVIDE CHECK VALVE ON DHW RETURN MAIN TO ENSURE NO BACK FLOW HO WATER TO PLUMBING FIXTURES. CONNECT FIXTURES ON THIRD AND FOURTH LEVELS TO WATER PIPES ON THIS FLOOR 36 INSTALL REFRIGERATOR BOX WITH MINI-ARRSTOR, CONNECT PER MANUFACTURES REQUIREMENTS. COORDIANTE THE EXACT LOCATION WITH CUSTOM LIVING. 37 PROVIDE FIXTURE AND INSTALL COMPLETE, PROVIDE FOOD WASTE GRINDER, CONNECT DISHWASHER COMPLETE. COORDIANTE ALL FIXTURES WITH CUSTOM LIVING PRIOR TO THE INSTALLATION OF ANY PIPE. 38 COORDIANTE ALL FIXTURES AND TRIM WITH CUSTOM LIVING, COORDIANTE ALL ROUGH-IN LOCATIONS AND ELEVATIONS WITH CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPING. 39 4"ST UP, FOR EXTERIOR DOWNSPOUT 40 COORDIANTE THE LOCATION OF THE FREE STANDING TUB 2"W AND THE SHOWER FLOOR DRAIN LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION OF ANY PIPE. 41 ALL SINKS WITH ADJACENT ICE MACHINES SHALL BE PROVIDED A TAIL PIECE ON THE SECOND BASIN TO ALLOW FOR THE ICE MACHINE PUMP TO PUMP DISCHARGE WATER INTO THE SINK DRAINAGE SYSTEM. COORDIANTE WITH CUSTOM LIVING ALL REQUIREMENTS. 42 PROVIDE 1/2"DCW FROM SINK TO REFRIGERATOR BOX. PROVIDE ISOLATION VALVE UNDER SINK TO SHUT OF REFRIGERATOR BOX WATER SUPPLY. PROVIDE AUXILARY STOP TO SERVE DHW TO DISH WASHER TO ALLOW FOR WATER SHUT-OFF TO DISH WASHER.. 1/4" = 1'-0"1 THIRD FLOOR SANITARY - LOT 30 # REVISION Date 05/02/19 Mike Sheeks