Loading...
HomeMy WebLinkAboutA40-0SECTION CUT PLAN DETAIL INTERIOR ELEVATION CALLOUT ROOM FINISH TAG WALL PARTITION TAG PLAN KEYNOTE DEMO KEYNOTE CEILING TAG X XX DETAIL/SECTION NO. SHEET NO. ON WHICH DETAIL/SECTION APPEARS X XX X/X X XX X X X SINGLE-VIEW ELEVATION TAG MULTI-VIEW ELEVATION TAG DETAIL NO. SHEET NO. ON WHICH DETAIL APPEARS CEILING NAME HEIGHT FLOOR WALL BASE X X X FLOORING TYPE WALL FINISH WALL BASE TYPE XX.X X X MATERIAL NOTEXX SYMBOL LEGEND 90 80 70 60 50 40 30 AREA OF WORK WALL TYPE NOTES: 1. REFER TO REFLECTED CEILING PLANS FOR STUD AND GYPSUM HEIGHTS. 2. PROVIDE MOISTURE RESISTANT GYPSUM WALL BOARD ON ALL "WET" WALLS. W4.1 INTERIOR PARTITION, 2x4 WOOD STUDS w/ 1/2" DRYALL EACH SIDE W4.2 INTERIOR PARTITION, 2x4 WOOD STUDS w/ 1/2" ONE SIDE W6.1 INTERIOR PARTITION, 2x6 WOOD STUDS w/ 1/2" DRYALL EACH SIDE W6.2 INTERIOR PARTITION, 2x6 WOOD STUDS w/ 1/2" DRYALL EACH SIDE DOUBLE 2x TOP PLATE BOTTOM OF STRUCTURAL FLOOR DECK STRUCTURAL FLOOR DECK 1/2" GYPSUM DRYWALL EACH SIDE PLAN VIEWSECTION VIEW 2x SILL PLATE 2x WOOD STUD FRAMING @ 16" O.C. ACOUSTIC SOUND BATT INSULATION (OPTIONAL) R TAR19900111 A CRHCETI STATE OF BTTOCS No. TSIGER ERED NETRA EP K SNI I A N ADNI ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. © 2017 BLACKLINE STUDIO CERTIFICATION: CHECKED:DRAWN: PRIVATE RESIDENCE - Lot 40S:\_Projects\Monon & Main - Carmel\002 Drawings\005 Revit\121818 _ Monon & Main - A18 - Townhome Interiors.rvt 3/21/2019 11:39:35 AM Monon & Main Brownstones Monon & Main St., Carmel IN CDs - PERMIT SET - 3/21/2019 COPYRIGHT 2018 A40-0COVERMonon & Main BrownstonesMonon & Main St., Carmel INwzwz CDs -PERMIT SET 3/21/2019 PRIVATE RESIDENCE -LOT 40 I-465 I-69I-70 I-65 I-465 I-74I-7 0 HW36 I-74 I-65HW3 6HW31 MERIDIANN ST. / HW31KEYSTONE AVE.I-465S. RANGELINE ROADE. MAIN ST. SITE SITE VICINITY MAP LOCATION MAP GENESIS ENGINEERING GROUP 91 S. MAIN ST. SUITE 20 ZIONSVILLE, IN 46077 T: 317.927.8307 GENESIS-ENGINEERING.COM BLACKLINE STUDIO 1043 VIRGINIA AVE., SUITE 208 INDIANAPOLIS, IN 46203 T: 317.803.7900 BLACKLINESTUDIO.NET SCHWARZ ENGINEERING GROUP JOHN@SCHWARZINC.COM T: 317.850.5133 WWW.SCHWARZINC.COM CUSTOM LIVING THE BARREL BUILDING 5335 WINTHROP AVE., SUITE A INDIANAPOLIS, IN 46220 T: 317.626-7393 CUSTOMLIVINGUSA.HOUZZ.COM PROJECT CONTACTS ARCHITECT MEP ENGINEER STRUCTURAL ENGINEER OWNER / CONTRACTOR SINGLE FAMILY - INTERIOR REMODEL INTERIOR PARTITION TYPES BROWNSTONE KEY PLAN DRAWING INDEX - Lot 40 A40-0 COVER A40-1 SITE PLAN & LIFE SAFETY PLAN A40-2 FIRST, SECOND AND THIRD FLOOR PLAN A40-3 FOURTH FLOOR & ROOF PLAN A40-4 REFLECTED CEILING PLANS A40-5 EXTERIOR ELEVATIONS A40-6 BLDG. & WALL SECTIONS, SCHEDUELS, & DETAILS # REVISION DATE 05/02/19 Mike Sheeks