Loading...
HomeMy WebLinkAboutA40-1SYMBOL/LINETYPE: DESCRIPTION: 1 HR FIRE BARRIER 2 HR SMOKE/FIRE BARRIER SMOKE RESISTANT CORRIDOR LIFE SAFETY PLAN LEGEND 3 HR SMOKE/FIRE BARRIER F.E.C. FIRE EXTINGUISHER CABINET BUILDING CODE ANALYSIS: APPLICABLE CODES: • 2005 INDIANA RESIDENTIAL CODE + AMENDMENTS (INTERNATIONAL RESIDENTIAL CODE 2003 EDITION) • INDIANA ENERGY CONSERVATION CODE 2010 + AMENDMENTS (ASHRAE 90.1, 2007 EDITION, AS AMENDED • NFPA 13R-2010 + AMENDMENTS (SPRINKLER SYSTEMS IN RESIDENTIAL OCCUPANCIES UP TO FOUR STORIES IN HEIGHT. STOR TOWNHOMES ARE REGULATED BY 2005 INDIANA RESIDENTIAL BUILDING CODE PER 2014 INDIANA BUILDING CODE SECTION 202 DEFINITION OF "TOWNHOUSE" AND HOUSE BILL 1301 CLASSIFYING TOWNHOMES AS A CLASS 2 STRUCTURE WITH NO NEED FOR PROPERTY LINES BETWEEN UNITS. AREA SUMMARY: BUILDING SHELL BASEMENT FLOOR AREA: 2,357 G.S.F. FIRST FLOOR AREA: 8,320 G.S.F. SECOND FLOOR AREA: 7,789 G.S.F. THIRD FLOOR AREA: 7,068 G.S.F. FOURTH FLOOR AREA: 6,693 G.S.F. TOTAL BUILDING AREA: 32,227 G.S.F. TWO-HOUR FIRE RATED WALLS BETWEEN EACH UNIT. EACH UNIT IS OPEN ON AT LEAST TWO SIDES. EGRESS WINDOWS REQUIRED FROM EACH BEDROOM. NO FIRE-RESISTANCE RATING NEEDED ON EXTERIOR WALLS GREATER THAN 3 FEET FROM PROPERTY LINE. DWELLING UNIT SEPERATION: 1. PENETRATIONS (BOTH THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS) OF WALL OR FLOOR/CEILING ASSEMBLIES OR FIRESTOP SYSTEM. EXCEPTIONS INCLUDE: A. MEMBRANE PENETRATIONS OF ELECTRICAL BOXES OF ANY MATERIAL WHICH HAVE BEEN TESTED FOR USE IN A FIRE-RATED ASSEMBLY OR NON-LISTED METAL BOXES, PROVIDED BOXES ON OPPOSITE SIDES OF FIRE-RATED WALL ARE SEPERATED BY A HORIZANTAL DISTANCE OF 24-INCHES OR SEPERATED BY SOLID FIRE-BLOCKING PER OR SEPARATED ACCORDING TO THE LISTING OF THE BOX. 2. THE 'APPROVED PENETRATION FIRESTOP SYSTEM' (SUCH AS REQUIRED AT THE DUCTWORK PENETRATIONS THROUGH RATED FIRST FLOOR CEILINGS) MUST BE INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E814 OR UL1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF0.01 INCH OF WATER AND SHALL HAVE A FIRE-RATING NOT LESS THAN THE REQUIRED FIRE- RESISTANCE RATING FO THE WALL PENETRATION. 3. ALTHOUGH THERE ARE MANY FIRESTOP SOLUTIONS, INCLUDING FIRE CAULK, INTUMESCENT SEALS, OR COLLAR SYSTEMS, THE SPECIFIC SYSTEM USED IN THIS PROJECT SHALL HAVE A UL NUMBER THAT GIVES THE INSTALLATION INFORMATION AND THE RATINGS AS TESTED BY UL. A COPY OF THE UL REPORT SHALL BE PROVIDED TO THE LOCAL FIRE MARSHALL FOR APPROVAL PRIOR TO ITS INSTALLATION. EXISTING PARKING GARAGE EXISTING OFFICE BUILDING EXISTING RESTAURANT EAST PROPERTY LINESOUTH PROPERTY LINE NORTH PROPERTY LINE WEST PROPERTY LINE1st STREET SW3rd AVENUE SWWEST MAIN STREET MONON TRAILPRIVATE DRIVE PRIVATE AUTOMOTIVE GATE PRIVATE MAN ENTRY GATE N SPRINKLER RISER ROOM GAS & WATER METERS REF. MEP DRAWINGS LOT-30 LOT-40 LOT-50 LOT-60 LOT-70 LOT-80 LOT-90 1' - 0"45' - 4" 31' - 8"127' - 7" 159' - 2 1/2"128' - 9 3/4"(NOT IN SCOPE) (NOT IN SCOPE) (NOT IN SCOPE) 1 1 1 1 1 1 2 3 4 PARKING GARAGE ENTRY/EXIT PUBLIC GREENSPACE EXIST. PATIO40' - 0"14' - 6"150' - 10 1/4"25' - 0"25' - 0"261' - 0 1/4"278' - 6"261' - 0 1/4"278' - 6"AREA OF WORK 4 A40-1 2 A60-1 1ST FLOOR 0" 2ND FLOOR 10' - 5 7/8" 3RD FLOOR 21' - 11 3/4" 4TH FLOOR 32' - 5 5/8" LEVEL 6 (t/o roof) 46' - 10 3/4" BASEMENT -9' - 9 1/4" 11 1 1 1 1 1 LOT 40 R TAR19900111 A CRHCETI STATE OF BTTOCS No. TSIGER ERED NETRA EP K SNI I A N ADNI ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.7900 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. © 2017 BLACKLINE STUDIO CERTIFICATION: CHECKED:DRAWN: S:\_Projects\Monon & Main - Carmel\002 Drawings\005 Revit\121818 _ Monon & Main - A18 - Townhome Interiors.rvt 3/21/2019 11:39:38 AM A40-1COPYRIGHT 2018 SITE PLAN & LIFE SAFETY PLANMonon & Main BrownstonesMonon & Main St., Carmel INwzwz CDs -PERMIT SET 3/21/2019 Lot 40 ---LIFE SAFETY PLAN NOTES 1 2-HR FIRE-RATED PARTITION FROM FIRST FLOOR SLAB OR FOUNDATION WALL UP TO UNDERSIDE OF ROOD SHEATHING. EXTEND TO INTERIOR FACE OF EXTERIOR WALL SHEATHING. WHERE ONE SIDE OF WALL EXTENDS FURTHER THEN THE OTHER, FIRE-RATED WALL SHALL RUN OUT TO FACE OF FURTHEST WALL PROTECTION. BASED ON UL LISTED DETAIL No. U336 2 2 Hr Fire Rated Assembly - Based on UL listed detail No. U301 3 SPINKLER RISER ROOM 4 PER TABLE 705.8 FIRE SEPERATION DISTANCE IS 25 TO LESS THAN 30 FEET. UNPROTECTED OPENINGS ARE 69% OF WALL AREA AND ARE LESS THAN 70% ALLOWABLE WALL AREA. #REVISION Date 05/02/19 Mike Sheeks