COORDINATE INSTALLATION OF LUMINAIRE
WITH BAR LEDGE
PROVIDE AUTOMATED OUTLET FOR WET
BAR LED TRANSFORMER AND OUTDOOR BAR
LEDGE TRANSFORMER
L1
A1 A1 A1 A1
A1
A1
A1 A1 A1
A1 A1 A1
A1
S
S
S
U U
A1
DF8 DF8
3
A2 A2
ROOF DECK
LOFT AREA
LIFT
W.I.C.
BATH
MECH 2
1
18
25
39
21
15
2222
10
18
18 LIFTSWITCH FOR FURNACE
POWER CIRCUIT
DATA RACK LV PANEL
F40 F40
33 34
32
ROOF DECK
LOFT AREA
LIFT
W.I.C. BATH
MECH 2
ARCHITECT
BLACKLINE
1 N MERIDIAN ST, SUITE 400
INDIANAPOLIS, INDIANA 46204
BLACKLINESTUDIO.NET
317.803.790
M.E.P.
GENESIS ENGINEERING GROUP
91 SOUTH MAIN STREET, SUITE 200
ZIONSVILLE, IN 46077
GENESIS-ENGINEERING.COM
317.927.8307
STRUCTURAL
SCHWARZ ENGINEERING GROUP
WWW.SCHWARZINC.COM
317.850.5133
-
-
ALL INFORMATION CONTAINED IN THIS DOCUMENT IS
CONSIDERED TO BE BOTH CONFIDENTIAL AND
PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE
STUDIO AND SHALL NOT BE COPIED, REPRODUCED,
DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT
PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO.
UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT
PERMITTED.
CERTIFICATION:
CHECKED:
DRAWN: C:\Users\jfakes\Documents\Custom Living Monon on Main Town Homes GEG R18_jfakes.rvt
4/12/2019 1:55:39 PM E40-4COPYRIGHT 2018 ELECTRICAL FOURTH FLOOR PLANSMonon & Main Brownstones
Monon & Main St., Carmel INJAWJAW
Monon and Main Brownstone
Interior Remodel – Unit 40
04/12/2019
Lot 40 -HALLETT RESIDENCE
PLAN NOTES
(NOT ALL NOTES MAY BE USED ON THIS SHEET)
1 DO NOT ROUTE ANY WIRING, PIPING, DUCTWORK, ETC., THROUGH LIFT SHAFT.
2 INSTALL LIGHT FIXTURE ABOVE VANITY MIRROR AT HEIGHT DETERMINED BY CUSTOM LIVING.
3 SURFACE MOUNT / SUSPEND LIGHT FIXTURE TO HEIGHT DETERMINED BY CUSTOM LIVING.
4 LIGHT FIXTURE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION.
5 INSTALL CEILING FAN CENTERED IN CEILING SPACE OF ROOM. PROVIDE U.L. LISTED CEILING FAN OUTLET KIT
RATED FOR FANS UP TO 70 POUNDS.
6 CENTER LIGHT FIXTURE WITHIN STAIRCASE CEILING SPACE.
7 LIGHT FIXTURE PROVIDED IN CORE AND SHELL PACKAGE.
8 INSTALL LIGHT FIXTURE AT HEIGHT DETERMINED BY CUSTOM LIVING.
9 CONNECT ALL LIGHTING ON THIS FLOOR TO A DEDICATED 120V, 20A, 1P CIRCUIT, UNLESS OTHERWISE NOTED..
10 DEVICE(S) INSTALLED IN CASEWORK. COORDINATE LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION.
11 NEMA 14-50R RECEPTACLE FOR RANGE. RECEPTACLE TO BE FLUSH MOUNTED OR OTHERWISE AS REQUIRED TO
ALLOW BACK OF RANGE TO BE PLACED FLUSH AGAINST WALL BEHIND THE RANGE. INSTALL RANGE RECEPTACLE
IN LOCATION AND ORIENTATION AS REQUIRED BY AND IN ACCORDANCE WITH THE SUPPLIED RANGE
MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION,
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION.
12 RECEPTACLE / CIRCUIT CONNECTION TO HOOD. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO
INSTALLATION. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
13 RECEPTACLE / CIRCUIT CONNECTION TO DISHWASHER. VERIFY EXACT LOCATION WITH CUSTOM LIVING PRIOR
TO INSTALLATION. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
14 GARBAGE DISPOSAL. CONFIRM IF SWITCH IS TO BE INSTALLED OVER COUNTERTOP AT +2" ABOVE BACKSPLASH
TO BOTTOM OF DEVICE OR AIR SWITCH IS TO BE USED. COORDINATE EXACT REQUIREMENTS WITH CUSTOM
LIVING PRIOR TO INSTALLATION. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
15 PROVIDE THE FOLLOWING FOR LOW VOLTAGE EQUIPMENT:
(1) 120V,20A,1P CIRCUIT FOR ALARM PANEL.
(2) 120V,20A,1P CIRCUITS AT EQUIPMENT RACK.
(1) 120V,20A,1P CIRCUIT FOR LOW VOLTAGE PANEL.
CONFIRM ALL QUANTITIES AND LOCATIONS WITH OWNER PRIOR TO ROUGH-IN.
16 RECEPTACLE FOR REFRIGERATOR / FREEZER. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
17 RECEPTACLE / CIRCUIT CONNECTION TO MICROWAVE. VERIFY EXACT LOCATION WTIH CUSTOM LIVING PRIOR TO
INSTALLATION. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
18 RECEPTACLE / TELECOM FOR WALL MOUNTED TELEVISION INSTALLED INSIDE RECESSED FLAT PANEL DISPLAY
BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH CUSTOM LIVING. CIRCUIT SHALL BE
SEPARATE FROM MECHANICALS AND APPLIANCES.
19 FLUSH MOUNTED ELECTRICAL PANEL. INSTALLATION SHALL MAINTAIN ANY FIRE RATING OF WALL. REFER TO
ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION.
20 RECEPTACLE IN CEILING FOR GARAGE DOOR OPENER. OPENER AND ASSOCIATED DEVICES PROVIDED BY
OTHERS. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
21 EXHAUST FAN. VERY EXACT LOCATION WITH CUSTOM LIVING PRIOR TO INSTALLATION. CONTROL VIA
AUTOMATED SWITCH - SEE LIGHTING PLANS - AND CONNECT TO 120V,20A,1P GFCI PROTECTED CIRCUIT.
22 2P-60A, 240V NEMA 3R FUSIBLE DISCONNECT SWITCH. FUSE THE DISCONNECT SWITCH PER EQUIPMENT
MANUFACTURER'S RECOMMENDATIONS.
23 RECEPTACLE FOR WASHER. PROVIDE DEDICATED 120V,20A,1P CIRCUIT.
24 NEMA 14-30R RECEPTACLE FOR CLOTHES DRYER. CONTRACTOR SHALL VERIFY RECEPTACLE CONFIGURATION,
CIRCUIT SIZE, AND MOUNTING HEIGHT WITH DRYER MANUFACTURER PRIOR TO INSTALLATION.
25 BATHROOM RECEPTACLE. CONFIRM EXACT LOCATION WITH CUSTOM LIVING PRIOR TO ROUGH-IN. PROVIDE
DEDICATED 120V,20A,1P CIRCUIT.
26 2P-30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURER'S RECOMMENDATIONS. DISCONNECT
SHALL BE LOCKABLE WITH INTERLOCKING COVER AND AUXILIARY CONTACT. PROVIDE CONNECTION TO LIFT
EQUIPMENT AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT SUPPLIER. CONNECT TO SHUNT TRIP
BREAKER IN UNIT PANEL.
27 2P-30A, 240V FUSIBLE DISCONNECT FUSED PER LIFT MANUFACTURER'S RECOMMENDATIONS. PROVIDE
CONNECTION TO LIFT LIGHTING AND CONTROL AS REQUIRED. COORDINATE EQUIPMENT LOCATION WITH LIFT
SUPPLIER.
28 WATER HEATER. PROVIDE DEDICATED 120V,20A,1P CIRCUIT. PROVIDE TOGGLE SWITCH DISCONNECT.
29 SUMP PUMP. PROVIDE (2) DEDICATED 120V,20A,1P CIRCUITS TO A SPLIT WIRE RECEPTACLE. PROVIDE 2-POLE
TOGGLE SWITCH DISCONNECT.
31 SMOKE DETECTOR SHALL BE STAND-ALONE PHOTOELECTRIC TYPE WITH 120V WITH BATTERY BACKUP.
DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE
UNIT.
32 SMOKE DETECTOR SHALL BE COMBINATION STAND-ALONE COMBINATION PHOTOELECTRIC AND CARBON
MONOXIDE TYPE WITH 120V WITH BATTERY BACKUP. DETECTORS WITHIN EACH UNIT SHALL BE
INTERCONNECTED TOGETHER SO THAT ALL DETECTORS ALARM IN THE UNIT.
33 HEAT DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER.
34 SMOKE DETECTOR INSTALLED AT TOP OF LIFT SHAFT. COORDINATE LOCATION WITH LIFT SUPPLIER.
35 TELEPHONE CONNECTION TO ELEVATOR CONTROLLER. PROVIDE (2) CAT5E CABLES IN 1" CONDUIT FROM
CONTROLLER TO UNIT LOW VOLTAGE PANEL.
36 PROVIDE FIRE ALARM ADDRESSABLE RELAY FOR LIFT. RELAY SHALL SHUNT-TRIP LIFT CIRCUIT BREAKER TO
SHUT DOWN LIFT PRIOR TO SPRINKLER SYSTEM RELEASE. INTERLOCK LIFT WITH FIRE ALARM SYSTEM AS
REQUIRED. PROVIDE CONTROL WIRING IN CONDUITS AS REQUIRED
37 HALF-SWITCHED RECEPTACLE. SWITCHED HAVE CONTROLLED BY ELECTRONIC EQUIPMENT PROVIDED UNDER
PREMIER SYSTEM. VERIFY CONTROL AND WIRING WITH PREMIER ELECTRONIC LIFESTYLES.
38 CONNECT ALL EXTERIOR ROOF DECK LIGHTING FIXTURES TO DEDICATED GFCI-PROTECTED 120V/20A/1P CIRCUIT.
39 PROVIDE FUSIBLE TOGGLE SWITCH FOR FURNACE POWER CIRCUIT. CONNECT CIRCUIT TO FURNACE THROUGH
FUSED SWITCH. FUSE THE SWITCH AS RECOMMENDED BY FURNACE MANUFACTURER'S INSTALLATION
INSTRUCTIONS. COORDINATE LOCATION OF SWITCH WITH MECHANICAL CONTRACTOR AND FURNACE
INSTALLATION INSTRUCTIONS.
1/4" = 1'-0"1 FOURTH FLOOR LIGHTING PLAN - LOT 40
1/4" = 1'-0"2 FOURTH FLOOR POWER PLAN - LOT 40
1/4" = 1'-0"3 FOURTH FLOOR SYSYEMS PLAN - LOT 40
# REVISION Date