Loading...
HomeMy WebLinkAboutM40-0ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT T SENSOR (T=TEMP H=HUMIDITY) (P=PRES V=VAC T=TEMP) GAUGE THERMOMETER PRESSURE AND TEMPERATURE PLUG WATER PRESSURE REDUCING/REGULATING VALVE AUTOMATIC AIR VENT MANUAL AIR VENT FLOOR DRAIN FLOW METER CLEANOUT TEMPERATURE CONTROL 3-WAY 2-POSITION VALVE MECHANICAL VALVE AND FITTING SYMBOLS DESCRIPTION SYMBOL TEMPERATURE CONTROL 2-WAY MODULATING VALVE TEMPERATURE CONTROL 2-WAY 2-POSITION VALVE TEMPERATURE CONTROL 3-WAY MODULATING VALVE CALIBRATED BALANCING VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED/FLANGED CAP CONCENTRIC REDUCER CHECK VALVE UNION STRAINER SAFETY RELIEF VALVE BUTTERFLY VALVE BALL VALVE GATE VALVE PLAN VIEW DETAIL VIEW R OR D FD SD F/SD MD DESCRIPTION SYMBOL DESCRIPTION MECHANICAL DUCTWORK SYMBOLS SYMBOL WITH FLEX DUCT SECTION PLAN VIEW STANDARD RADIUS ELBOW WITH CENTER RADIUS EQUAL TO 1 -1/2 TIMES WIDTH OF DUCT UNLESS OTHERWISE INDICATED FLAT OVAL SPIRAL DUCT (FIRST DIMENSION, SIDE SHOWN) RECTANGULAR DUCT (FIRST DIMENSION, SIDE SHOWN) SPIN -IN FITTING WITH MANUAL VOLUME DAMPER AND FLEXIBLE DUCT CONNECTION TYPICAL TERMINAL UNIT WITH REHEAT COIL GRILLE/REGISTER/DIFFUSER CONNECTION SIDEWALL SUPPLY, RETURN OR EXHAUST GRILLE DIFFUSER (NO AIRFLOW IN SHADED DIRECTION) INSULATED METAL PANEL 45 DEGREE LATERAL (ROUND OR FLAT OVAL ONLY) 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY) SQUARE-TO -ROUND TRANSITION CONICAL FITTING ROUND SPIRAL DUCT 90 DEGREE ELBOW WITH TURNING VANES FLEXIBLE CONNECTION BEVELED ENTRY FITTING MANUAL VOLUME DAMPER FIRE DAMPER WITH ACCESS DOOR SMOKE DAMPER WITH ACCESS DOOR FIRE/SMOKE DAMPER WITH ACCESS DOOR DUCT TURNED UP (SOLID LINES) DUCT TURNED DOWN (DASHED LINES) R(RISE), D(DROP) SUPPLY DIFFUSER OR SUPPLY GRILLE RETURN GRILLE EXHAUST GRILLE SUPPLY, RETURN, OR EXHAUST SLOT DIFFUSER W" X H" DIA"ø AUTOMATIC MOTOR OPERATED DAMPER W "X H"ø DIA"ø W" X H" CD CPD CHWR CR CS CHWS HWS HWR DIRECTION OF PIPE SLOPE (DOWN) CONDENSATE & EQUIPMENT DRAIN CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY HEATING WATER RETURN HEATING WATER SUPPLY HVAC PIPING SYMBOLS LINE SYMBOLS SCREENED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED AD ACCESS DOOR Ø °F A/E ACC ACCU AD ADJ AFCV AFF AFMS AGA AHU AL ANSI AO AP APD ARI AS ASHRAE ASME ASPE ASTM ATM AUTO AWWA B BCU BD BDD BHP BI BOD BOP BTUH CA CAP CAV CB CD CO2 CFM CH CHWP CHWR CHWS CO COMP COND CONV CP CPD CR CS CT CUH CWP dB DD DDC DEG DIA DISC DWH DWV DX EA EAT EC ECG EDR EER EF EFF EFT EG EMG EOM ESP ET EWT EXH F F&T FCO FCU FD FM FPB FPM FPS PHASE DEGREES FAHRENHEIT ARCHITECT/ENGINEER AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT AREA DRAIN, ACCESS DOOR ADJUSTABLE, ADJACENT AIRFLOW CONTROL VALVE ABOVE FINISHED FLOOR AIRFLOW MEASURING STATION AMERICAN GAS ASSOCIATION AIR HANDLING UNIT ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ANALOG OUTPUT ACID PROOF, ACCESS PANEL AIR PRESSURE DROP (IN. WC) AIR CONDITIONING REFRIGERATION INSTITUTE AIR SEPARATOR AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS AMERICAN SOCIETY OF MECHANICAL ENGINEERS AMERICAN SOCIETY OF PLUMBING ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS ATMOSPHERE AUTOMATIC AMERICAN WATER WORKS ASSOCIATION BOILER BLOWER COIL UNIT BALANCE DAMPER BACK-DRAFT DAMPER BRAKE HORSEPOWER OR BOILER HORSEPOWER BINARY INPUT, BACKWARD INCLINED BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME CATCH BASIN OR CHILLED BEAM CONDENSATE DRAIN CARBON DIOXIDE CUBIC FEET PER MINUTE CHILLER CHILLED WATER PUMP CHILLED WATER RETURN CHILLED WATER SUPPLY CLEANOUT COMPRESSOR CONDENSER CONVECTOR CONDENSATE PUMP CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY COOLING TOWER CABINET UNIT HEATER CONDENSER WATER PUMP DECIBEL DUAL DUCT DIRECT DIGITAL CONTROL DEGREE (°F) DIAMETER DISCONNECT SWITCH DOMESTIC WATER HEATER DRAIN, WASTE, AND VENT DIRECT EXPANSION EXHAUST AIR ENTERING AIR TEMPERATURE (°F) ELECTRICAL CONTRACTOR EGG-CRATE GRILLE EQUIVALENT DIRECT RADIATION ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY ENTERING FLUID TEMPERATURE (°F) EXHAUST GRILLE EXTRUDED METAL GRILLE (WELDED WIRE MESH) END OF MAIN DRIP EXTERNAL STATIC PRESSURE (IN. WC.) EXPANSION TANK ENTERING WATER TEMPERATURE (°F) EXHAUST FURNACE FLOAT AND THERMOSTATIC STEAM TRAP FLOOR CLEANOUT FAN COIL UNIT FLOOR DRAIN FACTORY MUTUAL FAN POWERED TERMINAL UNIT FEET PER MINUTE FEET PER SECOND ABBREVIATIONS AND TERMS FLOOR SINK FIRE/SMOKE DAMPER FINNED TUBE RADIATION GAGE OR GUAGE GALLON GENERAL CONTRACTOR GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE HEAD (FT.) HORSEPOWER HIGH PRESSURE STEAM RETURN HIGH PRESSURE STEAM SUPPLY HOT WATER PUMP HEATING WATER RETURN HEATING WATER SUPPLY HEAT EXCHANGER INTEGRAL FACE/BYPASS LEAVING AIR TEMPERATURE (°F) LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY LEAVING WATER TEMPERATURE (°F) MIXED AIR MIXED AIR TEMPERATURE (°F) THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY NOISE CRITERIA, NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL FIRE CODE NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE (°F) OPPOSED BLADE DAMPER OUTSIDE DIAMETER OWNER FURNISHED/CONTRACTOR INSTALLED PUMP PLUMBING CONTRACTOR PRESSURE DROP PRE-FILTER PROPYLENE GLYCOL WATER PREHEAT COIL PARTS PER MILLION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH (ABSOLUTE) POUNDS PER SQUARE INCH (GAUGE) PACKAGED TERMINAL AIR CONDITIONER RETURN AIR RETURN AIR TEMPERATURE (°F) RETURN FAN RETURN GRILLE RELATIVE HUMIDITY REHEAT COIL RADIANT PANEL ROOFTOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE (°F) SUPPLY DIFFUSER SEASONAL ENERGY EFFICIENCY RATIO SUPPLY GRILLE SHEETMETAL AND AIR CONDITIONING CONTRACTORS ASSOCIATION STATIC PRESSURE SUPPLY REGISTER SAFETY RELIEF VALVE STEAM VENT THERMOSTAT TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE THERMAL EXPANSION VALVE TYPICAL UNIT HEATER UNDERWRITER'S LABORATORIES VARIABLE AIR VOLUME VOLUME DAMPER VARIABLE FREQUENCY CONTROLLER (SAME AS VFD, VSC) VARIABLE FREQUENCY DRIVE (SAME AS VFC, VSC) VARIABLE SPEED CONTROLLER (SAME AS VFC, VFD) WITH WITHOUT WET BULB TEMPERATURE (°F) WATER PRESSURE DROP (FT. HD) WATER SOURCE HEAT PUMP FS FSD FTR GA GAL GC GPD GPH GPM HD HP HPR HPS HWP HWR HWS HX IFB LAT LPR LPS LWT MA MAT MBH MC MCA MCC MD MPR MPS NC NEC NFC NFPA NIC NO NTS OA OAT OBD OD OF/CI P PC PD PF PGW PHC PPM PRV PSI PSIA PSIG PTAC RA RAT RF RG RH RHC RP RTU SA SAT SD SEER SG SMACNA SP SR SRV SV T TCC TD TSP TXV TYP UH UL VAV VD VFC VFD VSC W/ W/O WB WPD WSHP ECCENTRIC REDUCER GLOBE VALVE T STEAM TRAP VACUUM BREAKER ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.790 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. CERTIFICATION: CHECKED: DRAWN: C:\Users\jfakes\Documents\Custom Living Monon on Main Town Homes GEG R18_jfakes.rvt 4/12/2019 2:44:49 PM M40-0COPYRIGHT 2018 MECHANICAL SYMBOLS AND ABBREVIATIONS Monon & Main Brownstones Monon & Main St., Carmel INTRTR Monon and Main Brownstone Interior Remodel – Unit 40 04/12/2019 Lot 40 -HALLETT RESIDENCE # REVISION Date 05/02/19 Mike Sheeks