HomeMy WebLinkAboutM40-3DIFFUSER/REGISTER/GRILLE SCHEDULE TAG NECK SIZE FACE SIZE (IN.) MATERIAL CFM RANGE MAX. NC MAX. TOTAL A.P.D. (IN. WG.) MANUFACTURER MODEL NOTES DESIGN REFERENCE THROW (FT. BASED ON VELOCITY OF 50 FPM) 20 0.040 PRICE SR1 10"x6" 10"x6"0 - 150 20 0.040 PRICE 640 11ALUMINUM NOTES: 1. BRANCH DUCT RUNOUT TO THE DIFFUSER SHALL BE THE SAME SIZE AS THE DIFFUSER NECK UNLESS NOTED OTHERWISE ON THE DRAWINGS. 2. ALL SUPPLY DIFFUSER BACKPLATES SHALL BE INSULATED WITH A MINIMUM OF 1" INSULATION. INSULATION MAY BE FACTORY OR FIELD APPLIED. 3. PROVIDE FRAME STYPLE APPROPRIATE FOR CEILING TYPE (I.E. LAY-IN, SURFACE MOUNT, SIDEWALL, ETC.). REFER TO DRAWINGS AND ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS. 4. PLENUM RETURN GRILLES SHALL HAVE A RETURN BOOT WITH RETURN DAMPER ATTACHED TO THE BACK. 5. 1/8" BARS, 1/2" BLADE SPACING, 15° DEFLECTION. AIR TERMINAL TYPE SUPPLY REGISTER 1, 2, 3 1, 2, 3 SR2 14"x6" 14"x6"155 - 200 640 13ALUMINUM SUPPLY REGISTER RG1 RETURN GRILLE 8"x10" 8"x10" ALUMINUM 0 - 200 - 20 0.040 PRICE 630 FSR1 FSR2 LINEAR BAR FLOOR GRILLE LINEAR BAR FLOOR GRILLE 12"x4" 12"x6" 0 - 125 130 - 200 12"x4" 12"x6" ALUMINUM ALUMINUM 15 17 20 20 0.040 0.040 PRICE PRICE LBPH LBPH 2, 3, 5 1, 3, 4 2, 3, 5 RG2 RETURN GRILLE 20"x18" 20"x18" ALUMINUM 750 - 1000 - 20 0.040 PRICE 630 1, 3, 4 EG1 EXHAUST GRILLE 6"x6" 6"x6" ALUMINUM 20 - 75 - 20 0.040 PRICE 630 1, 3, 4 DRYER DUCT THROUGH ROOF DRYER VENT, CONSTRUCTED OF MINIMUM 26 GAUGE GALVANIZED SHEETMETAL WITH NO SCREWS OR DAMPERS THAT COULD CATCH LINT. STEEL SLEEVE FLEXIBLE SEALANT RATED FOR 400°F FINISHED ROOF LINE 8" MINIMUM. TALLER AS REQUIRED FOR ROOFING WARRANTY ANCHOR HOOD TO CURB, 6" O.C. MINIMUM 3" CLEAR FROM VENT TO METAL LINER SEAL ALL EXPOSED SEAMS WATERTIGHT HEIGHT ABOVE ROOF DECK. MAKE HEIGHT AS LOW AS POSSIBLE BUT NOT LESS THAN 2'-0". ALUMINUM EXHAUST HOOD WITH SWING OUT DAMPER. 4" DISCHARGE SIZE (NOT 2-1/2"). HIGH TEMPERATURE SILICONE SEAL STAINLESS STEEL HOOD 18 GAUGE. FORCE FIT TO VENT WOOD NAILER 16" TALL SQUARE CURB WITH METAL LINER ROOF CONSTRUCTION PACKED INSULATION METAL ESCUTCHEON FORCE FIT TO VENT STRUCTURAL FRAME AROUND OPENING. SEE STRUCTURAL DRAWINGS OR PROVIDE <4"X4"X5/16". . FLEXIBLE DUCTWORK BENDS SHALL NOT BE LESS THAN 1.5 TIMES THE DUCT DIAMETER. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY -FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SECURED WITH A DRAW BAND. TAPE AND SEAL ALL JOINTS AND SEAMS WITH FSK TAPE TO MAINTAIN VAPOR BARRIER. SUPPORT FLEXIBLE DUCTWORK FROM STRUCTURE. DO NOT SUPPORT FLEXIBLE DUCTWORK FROM ADJACENT ABOVE CEILING UTILITIES (DUCTWORK, PIPING, CONDUITS, ETC.) A. B. C. GENERAL DETAIL NOTES: FLEX DUCT -MAXIMUM 8'-0" LENGTH AND NO MORE THAN TWO (2) 90° BENDS. INSULATE BACK OF SUPPLY DIFFUSERS WITH 1" MINERAL FIBER INSULATION WITH FSK JACKET. TAPE AND SEAL INSULATION VAPOR BARRIER. CEILING SUPPLY DIFFUSER ATTACH FLEXIBLE DUCTWORK WITH DRAWBAND AND SEAL INSULATION AND VAPOR BARRIER TO FSK TAPE. INSTALL MANUAL VOLUME DAMPER AT ALL BRANCH DUCTS. PROVIDE 2" EXTENDED OPERATOR HANDLE FOR INSULATED DUCTS. SPIN -IN FITTING AT BRANCH/MAIN CONNECTION. ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.790 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. CERTIFICATION: CHECKED: DRAWN: C:\Users\jfakes\Documents\Custom Living Monon on Main Town Homes GEG R18_jfakes.rvt 4/12/2019 2:00:49 PM M40-3COPYRIGHT 2018 MECHANICAL SCHEDULES AND DETAILSMonon & Main Brownstones Monon & Main St., Carmel INChecker Author Monon and Main Brownstone Interior Remodel –Unit 40 04/12/2019 Lot 30 -ERNST RESIDENCE NO SCALE2DRYER VENT DETAIL 40 NO SCALE3CEILING DIFFUSER/GRILLE DETAIL 40 NOTES: 1. DIRECT DRIVE WITH SOLID STATE SPEED CONTROLLER. 2. DISCONNECT BY MANUFACTURER. 3. FAN SHALL OPERATE VIA DISCONNECT (24/7). NOTES: 1. R410A REFRIGERANT. 2. ANTI-SHORT CYCLE TIMER. NOTES: 1. HEAT RATING BASED ON 40% LOW INPUT 2. VARIABLE SPEED BLOWER. 3. PROVIDE 1" TRAPPED CONDENSATE PIPED TO FLOOR DRAIN. 4. DX COIL CASED FOR UPFLOW. 5. DX COIL CASED FOR DOWNFLOW. 6. RETURN AIR SUB BASE BY MANUFACTURER. 7. CONCENTRIC VENT KIT BY MANUFACTURER. 8. SPACE TEMPERATURE MEASURED VIA COMMON RETURN AIR SENSOR. SYSTEM SHALL RESPOND TO MOST RECENT INPUT FROM ANY CONNECTED THERMOSTAT. # REVISION Date AIR COOLED CONDENSING UNIT SCHEDULE 40 MARK COOLING CAPACITY (BTUH) MIN. SEER ELECTRICAL DATA UNIT WEIGHT (LBS) BASIS OF DESIGN MAX SOUND RATING (dB) NOTESMCA MOCP VOLTS PHASE MANUFACTURER MODEL ACCU-1-40 36,000 15 23 35 208 1 240 TRANE 4TTV0036A100A 70 1,2 ACCU-2-40 36,000 15 23 35 208 1 240 TRANE 4TTV0036A100A 70 1,2 FAN SCHEDULE 40 TAG LOCATION AIRFLOW (CFM) E.S.P. (IN.W.G.)POWER FAN TYPE FAN RPM DRIVE ELECTRICAL REQUIREMENTS WEIGHT (LBS)DESIGN REFERENCE NOTESAMPS VOLT/PHASE MANUFACTURER MODEL EF-1-40 MECHANICAL 120 0.3 1/20 HP INLINE CENTRIFUGAL 1171 DIRECT 6 120/1 49 GREENHECK SQ-80-VG 1,2,3 FURNACE SCHEDULE 40 MARK CONFIGURATION NOMINAL TONS AIRFLOW (CFM) FAN DATA COOLING DATA HEATING DATA ELECTRICAL DATA BASIS OF DESIGN UNIT WEIGHT (LBS) NOTESESP DRIVE HP TOTAL BTU EAT DB (°F) EAT WB (°F) BTU INPUT BTU OUTPUT EAT DB (°F) AFUE (%) MCA MOCP VOLTS PHASE MANUFACTURER MODEL F-1-40 VERTICAL UPFLOW CONDENSING GAS 2 700 0.3 DIRECT 0.5 24,000 75 63 24,000 23,000 70 95 11.1 15 120 1 TRANE TUHMB060ACV3VA 170 1,2,3,4,6,7 F-2-40 VERTICAL DOWNFLOW CONDENSING GAS 3.0 900 0.3 DIRECT 0.5 36,000 75 63 32,000 30,000 70 95 11.1 15 120 1 TRANE TDHMB080ACV3VB 170 1,2,3,5,6,7,8 05/02/19 Mike Sheeks