Loading...
HomeMy WebLinkAboutP40-0DOMESTIC COLD WATER DOMESTIC HOT WATER RETURN DOMESTIC HOT WATER FIRE PROTECTION NATURAL GAS SANITARY 6" DCW 6" DHW 6" DHWR 6" FP 6" NG VENT 6" S 6" V 6" SCW DOMESTIC SOFT COLD WATER ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT NT CONNECTION OF NEW WORK TO EXISTING DETAIL WITH TOP LETTER INDICATING DETAIL DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON SECTION WITH TOP NUMBER INDICATING SECTION DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ONA. GENERAL NOTE 1 FLOOR PLAN SYMBOLS PLAN NOTE THERMOSTAT - "N" INDICATING NIGHT SETBACK THERMOSTAT H HUMIDISTAT 1. PLAN NOTE LIST ABBREV. A/E AC OR ACU ACCU AD ADJ AFCV AFF AFMS AHU APD APPROX AR ARCH AS ATM AV AVMS AW B BCU BDD BHP BI BLDG BOT BP BST BTU BTUH CA CAP CAV CC CCP CDS CENTRIF CFM CFOI CH CI CO CO2 COL COM COMP CONC CONN CONST CONT CP CPD CUH CW CWM CWP CWR CWS D DB DC DCV DCWBP DD DDC DE DEFL DEG DEPT DHWBP DI DIA DISC DISCH DS DSWBP DUC DWG DW DWBP DWH EA EAT EBH EC ECC ECG ED EDC EER EF EFT EG ELEC ELEV EMER EMG ENCL ENTR EOM EQA EQAC EQAI EQUIP EQV EQVP EQV V ERP ES ESP ET EUH EW EWC EWT EXH EXIST EXT F F&B F&T F/A F/SD FC FCU FD FH ABBREV. FHC FIN FLA FLR FODT FOP FOR FOS FOST FOV FP FPB FPC FPM FPS FPST FS FT FTG FTR G GA GAL GALV GC GH GPH GPM GV H HC HCP HD HE HGT HO HOA HORZ HOSP HP HPR HPS HR HRC HTR HVAC HW HWC HWCP HWP HWR HWS HX HZ IA IAC IAD ID IFB IHOM IN INCL INSUL INT INV I.P.S. ISOL JT KAIC KEC KW L LAC LAD LAN LAT LAV LBD LBS LD LF LFD LFT LOC LPR LPS LVG LVP LWT MA MAC MAD MAI MAT MAX MB MBH MC MCA MCC MD MECH MFR MH MIN MISC MOCP MPSR MPS MTD MV MVP N NA NC NIC NM NO NOM NTS O OA OAT ABBREV. OC OD OFCI OFOI OM OPER OPNG OSD P PC PD PE PF PG PHC PIV PLT POC PPH PPM PRD PREFAB PRES PRV PSI PSIG PVC RA RAD RAT R/H RD REC RECIR REF RF RG RH RHC RLA RM ROM ROP ROST RP RPG RPM RPZ REQ'D RV S SA SB SC SCC SCCH SCFM SCH SCW SD SEC SENS SEP SF SG SHT SHW SK SMBH SMC SP SPEC SQ SQFT SRV ST STD STM STR STRUCT SV SW SYS SZ T TB TCC TDH TDV TEMP THW TLL TMV TMBH TSP TW UH UNO UR UVL V VAC VAV VB VD VEL VSC VTR V V W WAGD WB W/ W/O WC WCO WFMD WG WGT WH WM WP WPD WS # DESCRIPTION ARCHITECT AND ENGINEER AIR CONDITIONING UNIT OR AIR COMPRESSOR AIR COOLED CONDENSING UNIT ACCESS DOOR ADJUSTABLE OR ADJACENT AIRFLOW CONTROL VALVE ABOVE FINISHED FLOOR AIR FLOW MEASURING STATION AIR HANDLING UNIT AIR PRESSURE DROP APPROXIMATE AIR RECEIVER ARCHITECT AIR SEPARATOR ATMOSPHERE ACID VENT AIR VOLUME MEASURING STATION ACID WASTE BOILER BLOWER COIL UNIT BACKDRAFT DAMPER BRAKE HORSEPOWER BACKWARD INCLINED BUILDING BOTTOM BRINE PUMP BULK SALT STORAGE BRITISH THERMAL UNIT BTU PER HOUR COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME COOLING COIL COOLING COIL PUMP CONDENSATE PUMP DISCHARGE CENTRIFUGAL CUBIC FEET PER MINUTE CONTRACTOR FURNISHED/OWNER INSTALLED CHILLER CAST IRON CLEAN OUT CARBON DIOXIDE COLUMN CARBON DIOXIDE MANIFOLD COMPRESSOR CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONDENSATE PUMP CONDENSATE PUMP DISCHARGE CABINET UNIT HEATER COLD WATER COLD WATER MAKE -UP CHILLED WATER PUMP CHILLED WATER RETURN CHILLED WATER SUPPLY DIFFUSER OR DAMPER DECIBELS OR DRY BULB DUCT COIL DOUBLE CHECK VALVE DOMESTIC COLD WATER BOOSTER PUMP DUAL DUCT DIRECT DIGITAL CONTROL DEAERATOR DEFLECTION DEGREE DEPARTMENT DOMESTIC HOT WATER BOOSTER PUMP DEIONIZED WATER DIAMETER DISCONNECT DISCHARGE DOWNSPOUT DOMESTIC SOFT WATER BOOSTER PUMP DOOR UNDER CUT DRAWING DISTILLED WATER DOMESTIC WATER BOOSTER PUMP DOMESTIC WATER HEATER EXHAUST AIR ENTERING AIR TEMPERATURE ELECTRIC BASEBOARD HEATER ELECTRICAL CONTRACTOR ENVIRONMENTAL CONTROL CONTRACTOR EGG CRATE GRILLE EXHAUST DIFFUSER ELECTRIC DUCT COIL ENERGY EFFICIENCY RATIO EXHAUST AIR FAN ENTERING FLUID TEMPERATURE EXHAUST GRILLE OR ETHYLENE GLYCOL ELECTRIC ELEVATION EMERGENCY EXTRUDED METAL GRILLE ENCLOSURE ENTERING END OF MAIN DRIP EQUIPMENT AIR EQUIPMENT AIR COMPRESSOR EQUIPMENT AIR INTAKE EQUIPMENT EQUIPMENT VACUUM EQUIPMENT VACUUM PUMP EQUIPMENT VACUUM VENT ELECTRIC RADIANT PANEL EMERGENCY SHOWER EXTERNAL STATIC PRESSURE OR ELEVATOR SUMP PUMP EXPANSION TANK ELECTRIC UNIT HEATER EMERGENCY EYEWASH ELECTRIC WATER COOLER ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR DEGREES FAHRENHEIT FACE & BYPASS FLOAT AND THERMOSTATIC TRAP FIRE ALARM FIRE AND SMOKE DAMPER FLEXIBLE CONNECTION FAN COIL UNIT FLOOR DRAIN OR FIRE DAMPER FIRE HOSE OR FUME HOOD DESCRIPTION FIRE HOSE CABINET FINISH FULL LOAD AMPS FLOOR FUEL OIL DAY TANK FUEL OIL PUMP FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL STORAGE TANK FUEL OIL VENT FIRE PROTECTION FAN POWERED BOX FIRE PROTECTION CONTRACTOR FEET PER MINUTE FEET PER SECOND FIRE PROTECTION STORAGE TANK FLOW SWITCH FEET OR FLASH TANK FOOTING OR FITTING FIN TUBE RADIATION GAS, NATURAL GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GRAVITY HOOD GALLONS PER HOUR GALLONS PER MINUTE GAS NATURAL VENT HUMIDIFIER, HUMIDITY OR HEIGHT HEATING COIL HEATING COIL PUMP (HOT WATER) HEAD HEAT EXCHANGER HEIGHT HUB OUTLET HAND -OFF -AUTOMATIC HORIZONTAL HOSPITAL HORSEPOWER OR HEATPUMP HIGH PRESSURE CONDENSATE RETURN HIGH PRESSURE STEAM HOUR HEAT RECOVERY COIL HEATER HEATING, VENTILATION AND AIR CONDITIONING DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRC HOT WATER CIRCULATING PUMP HEATING HOT WATER PUMP HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HEAT EXCHANGER HERTZ INSTRUMENT AIR INSTRUMENT AIR COMPRESSOR INSTRUMENT AIR DRYER, EQAD INSIDE DIAMETER OR DIMENSION INTEGRAL FACE AND BYPASS IN -HOUSE OXYGEN MANIFOLD INCHES INCLUDE INSULATED INTERIOR INVERT INTERNATIONAL PIPE SIZING ISOLATION JOINT SHORT CIRCUIT RATING KITCHEN EQUIPMENT CONTRACTOR KILOWATTS LENGTH LAB AIR COMPRESSOR LAB AIR DRYER LOCAL AREA NETWORK LEAVING AIR TEMPERATURE LAVATORY LINEAR BAR DIFFUSER POUNDS LINEAR DIFFUSER LINEAR FOOT LAMINAR FLOW DIFFUSER LEAVING FLUID TEMPERATURE LOCATION LOW PRESSURE CONDENSATE RETURN LOW PRESSURE STEAM LEAVING LAB VACUUM PUMP LEAVING WATER TEMPERATURE MEDICAL AIR MEDICAL AIR COMPRESSOR MEDICAL AIR DRYER MEDICAL AIR INTAKE MIXED AIR TEMPERATURE MAXIMUM MOP BASIN BTU/HR X 1000 MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MAXIMUM OVERCURRENT PROTECTION MEDIUM PRESSURE CONDENSATE RETURN MEDIUM PRESSURE STEAM MOUNTED MEDICAL VACUUM MEDICAL VACUUM PUMP NORTH OR NITROGEN NOT APPLICABLE NORMALLY CLOSED OR NOISE CRITERIA NOT IN CONTRACT NITROGEN MANIFOLD NORMALLY OPEN, NITROUS OXIDE, OR NUMBER NOMINAL OR NITROUS OXIDE MANIFOLD NOT TO SCALE OXYGEN OUTSIDE AIR OUTSIDE AIR TEMPERATURE DESCRIPTION ON CENTER OUTSIDE DIAMETER OWNER FURNISHED/CONTRACTOR INSTALLED OWNER FURNISHED/OWNER INSTALLED OXYGEN MANIFOLD OPERATOR OPENING OPEN SITE DRAIN PUMP, PNEUMATIC OR PRESSURE PLUMBING CONTRACTOR PRESSURE DROP OR PERFORATED DIFFUSER PNEUMATIC ELECTRIC PREFILTERS PROPYLENE GLYCOL PREHEAT COIL POST INDICATOR VALVE PLASTER TRAP POINT OF CONNECTION POUNDS PER HOUR PARTS PER MILLION PRESSURE RELIEF DOOR PREFABRICATED PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE RETURN AIR OR RELIEF AIR RADIATED RETURN AIR TEMPERATURE REHEAT ROOF DRAIN RECEIVER RECIRCULATING REFRIGERATOR RETURN AIR FAN RETURN GRILLE RELIEF HOOD OR RELATIVE HUMIDITY REHEAT COIL RUNNING LOAD AMPS ROOM REVERSE OSMOSIS VENT REVERSE OSMOSIS PUMP REVERSE OSMOSIS STORAGE TANK RADIANT PANELS RETURN PERFORATED GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW REQUIRED ROOF VENTILATOR SANITARY OR SEWER SUPPLY AIR OR SOUND ATTENUATOR STEAM BOILER STEAM COIL STEAM CONDENSATE COOLER SUBCOOLED CHILLER STANDARD CUBIC FEET PER MINUTE SCHEDULE SOFT COLD WATER (DOMESTIC) SUPPLY DIFFUSER OR SMOKE DAMPER SECTION SENSIBLE SEWAGE EJECTOR PUMP SUPPLY AIR FAN SUPPLY GRILLE SHEET SOFT HOT WATER SINK SENSIBLE MBH SHEET METAL CONTRACTOR STATIC PRESSURE OR STORM PUMP SPECIFICATIONS SQUARE SQUARE FEET SAFETY RELIEF VALVE STEAM TRAP STANDARD STORM STARTER STRUCTURAL STEAM VENT SWITCH SYSTEM SPRINKLER ZONE THERMOSTAT TERMINAL BOX TEMPERATURE CONTROL CONTRACTOR TOTAL DISCHARGE HEAD TRIPLE DUTY VALVE TEMPERATURE TEMPERED HOT WATER TEMPERATURE LOW LIMIT THERMOSTAT MIXING VALVE TOTAL MBH TOTAL STATIC PRESSURE TEMPERED WATER UNIT HEATER UNLESS NOTED OTHERWISE URINAL ULTRA VIOLET LIGHT VENT VACUUM VARIABLE AIR VOLUME VACUUM BREAKER VOLUME DAMPER (MANUAL) VELOCITY VARIABLE SPEED CONTROLLER VENT THROUGH ROOF VACUUM VENT WASTE, WATTS OR WIDTH WASTE ANESTHESIA GAS DISPOSAL PUMP WET BULB WITH WITHOUT WATER CLOSET OR WATER COLUMN WALL CLEAN OUT WATER FLOW MEASURING DEVICE WATER GAUGE WEIGHT WALL HYDRANT WATER METER WEATHERPROOF WATER PRESSURE DROP WATER SOFTENER POUND ACD AIR CONDITIONING CONDENSATE DRAIN MECHANICAL AND PLUMBING ABBREVIATIONS PLUMBING PIPING SYMBOLS VALVE AND FITTING SYMBOLS CALIBRATED BALANCE VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED NIPPLE W/CAP PIPE WITH BLIND FLANGE CONCENTRIC REDUCER ECCENTRIC REDUCER CHECK VALVE UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE TEMPERATURE CONTROL - 2 WAY MODULATING VALVE TEMPERATURE CONTROL - 2 WAY 2 POSITION MODULATING VALVE TEMPERATURE CONTROL - 3 WAY MODULATING VALVE TEMPERATURE CONTROL - 3 WAY 2 POSITION MODULATING VALVE SAFETY RELIEF VALVE STRAINER FLOW METER FLOOR DRAIN ZONE CONTROL VALVE (OS&Y) AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AIR RELIEF VENT AUTOMATIC AIR RELIEF VENT LUBRICATED PLUG VALVE STEAM PRESSURE REDUCING VALVE ANGLE VALVE GAS PRESSURE RELIEF VALVE REFRIGERANT HOT GAS BY -PASS VALVE SHUT -OFF COCK (HYDRONICS) SOLENOID VALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCING/REGULATING VALVE COMBINATION WATER PRESSURE RELIEF AND REDUCING VALVE STEAM TRAP DIELECTRIC UNION BETWEEN STEEL AND COPPER STRAINER (STEAM) PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER (P=PRESS V=VAC T=TEMP) GAUGE SENSOR (T-TEMP H -HUMIDITY) FLOW SWITCH CLEAN OUT WATER HAMMER ARRESTOR OR ALARM PRESSURE/VACUUM SWITCH INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REDUCED PRESSURE BACKFLOW PREVENTER ATMOSPHERIC VACUUM BREAKER PRESSURE VACUUM BREAKER REFRIGERANT SHUT -OFF VALVE DOMESTIC WATER TEMPERATURE REGULATING VALVE EXPANSION JOINT DIFFERENTIAL SWITCH∆T P A T T A NO NC NO NC DETAIL VIEW PLAN VIEWS A101 1 TYP 1 A101 TYP TAGS V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 V26 V27 V28 V29 V30 V31 V32 V33 V34 V35 V36 V37 V38 V39 V40 V41 V42 V43 V44 V45 V46 V47 V48 V49 V50 V51 V52 V53 V54 V55 V56 V57 V58 V59 V60 TYP TYPICAL CV CENTRAL VACUUM CENTRAL VACUUM OUTLET V61 GENERAL NOTES 1. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. 2. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGINEERS ATTENTION IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. 3. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. 4. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SET OF CONSTRUCTION DOCUMENTS. 5. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. 6. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS AND/OR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. 7. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. 8. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. 9. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. 10. ALL PLUMBING EQUIPMENT, PIPING, FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. 11. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25/50 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. 12. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 13. ALL VENT THROUGH ROOF (VTR) LOCATIONS SHALL BE FIELD VERIFIED IN REGARDS TO ANY OUTDOOR INTAKE. LOCATION OF VTR SHALL BE NO LESS THAN AS REQUIRED BY THE LOCAL OR STATE CODES. 14. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON -STRUCTURAL ITEM. 15. DO NOT WELD OR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU -BOLTS WITH WASHERS 16. DO NOT USE ANY PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND NAILERS, CONCEALED OR NOT SHALL BE FIRE RETARDANT TREATED. 17. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING LANDLORDS ROOFING CONTRACTOR. 18. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE LANDLORDS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 19. PIPING BELOW GROUND SHALL BE SERVICE -WEIGHT CAST IRON OR SCHEDULE 40 PVC. NO -HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. 20 DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE "L" WATER TUBE. 21. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. 22. NO SANITARY WASTE OR VENT, HOT OR COLD WATER SHALL BE ALLOWED TO BE INSTALLED IN THE DEMISING WALLS. 23. ALL PIPING INSULATED SHALL BE WITH PLENUM RATED MATERIALS. 24. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS. 25. GAS PIPING SUPPORTED ON THE ROOF SHALL BE PROVIDED FREE FLOATING PREFABRICATED SUPPORTS OR EQUIPMENT SUPPORTS WITH ROLLER ASSEMBLIES. WOOD SUPPORTS WILL NOT BE PERMITTED. 26. ALL GAS PIPING SHALL BE PROVIDED PIPE LABELS IDENTIFYING THE GAS PRESSURE. 27. ALL GAS PIPING SHALL BE INSTALLED PER THE LOCAL CODES FOR MATERIALS AND INSTALLATIONS REQUIREMENTS. 28. ALL SHUT -DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO LESS THAN SEVEN (7) DAYS NOTICE TO THE LANDLORD. WORK MAY NOT COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE LANDLORD. 29. ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQUIPMENT WITH FAST ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. 30. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. (REQUIRED TO COMPLETE THE SCOPE OF WORK) ARCHITECT BLACKLINE 1 N MERIDIAN ST, SUITE 400 INDIANAPOLIS, INDIANA 46204 BLACKLINESTUDIO.NET 317.803.790 M.E.P. GENESIS ENGINEERING GROUP 91 SOUTH MAIN STREET, SUITE 200 ZIONSVILLE, IN 46077 GENESIS-ENGINEERING.COM 317.927.8307 STRUCTURAL SCHWARZ ENGINEERING GROUP WWW.SCHWARZINC.COM 317.850.5133 - - ALL INFORMATION CONTAINED IN THIS DOCUMENT IS CONSIDERED TO BE BOTH CONFIDENTIAL AND PROPRIETARY INTELLECTUAL PROPERTY OF BLACKLINE STUDIO AND SHALL NOT BE COPIED, REPRODUCED, DISTRIBUTED OR ASSIGNED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT OF BLACKLINE STUDIO. UNAUTHORIZED USE OF THESE DOCUMENTS IS NOT PERMITTED. CERTIFICATION: CHECKED: DRAWN: C:\Users\jfakes\Documents\Custom Living Monon on Main Town Homes GEG R18_jfakes.rvt 4/12/2019 2:00:52 PM P40-0COPYRIGHT 2018 PLUMBING SYMBOLS AND ABBREVIATIONS Monon & Main Brownstones Monon & Main St., Carmel INWAMWAM Monon and Main Brownstone Interior Remodel – Unit 40 04/12/2019 Lot 40 -HALLETT RESIDENCE # REVISION Date 05/02/19 Mike Sheeks