HomeMy WebLinkAboutDuvvuri Custom Compliance SheetCustom Compliance Sheet For Duvvuri/Calyam (15’x16’) Criteria: This Sunroom: Room Area < 500 Sq. Ft. 240 Sq. Ft >40% Glazing of Gross Exterior Wall & Roof Area 52 % Thermally Isolated Not Used as a Kitchen or Sleeping Quarters Separate Heating/Cooling System or Zone 30 Amp Amana PTAC 2009 IECC Sunroom Insulation Requirements Required American Sunspace Climate Zone R-Value/U-Factor Compliance Ceiling R-24 5 R-27 Yes Walls R-13 5 R-13.5 Yes Floor R-21 5 R-25 Yes Fenestration U=0.50 5 R=3.5/U=0.29 Yes Skylights U=0.75 All N/A N/A Climate Zone: 5 Hamilton County Indiana Sunroom Energy Code Compliance Sheet The REScheck Software Tools Cannot Currently Be Used To Show Compliance Using The Prescriptive Criteria Alternative Compliance Defined For Sunrooms In The 2009 IECC. 04/08/19 Mike Sheeks