HomeMy WebLinkAboutLEGACY PRAIRIE 101 - LP101 (AS DESIGNED)IECC 2009 Performance Compliance
Property
7243 BARKER ST
CARMEL, IN 46033
Model: TALBOTT II
Community: LEGACY PRAIRIE 101
LP101 (AS DESIGNED)
LEGACY PRAIRIE 101
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cast
IECC 2009 Performance
$931
$133
$350
$1,414
$554
$0
$1,968
Requirements
C-M,
Energy Solutions
As designed
S775
S148
S350
$1,273
S554
SO
$1,82T
C4405.3 Performance-based compliance passes by 10.0%
402.4.12 Air Leakage Testing Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 10%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons Signature:
Organization: TSI Energy Solutions Digitally signed: 3/11119 at 9:39 AM
Ekotrope RATER - Version 3.1.0.2128
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7243 BARKER ST
IilriFri M
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor R-38
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 6 ACH50
Window U -Value: 0.32, SHGC: 0.34
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 133.0 CFM @ 25Pa
Total Duct Leakage 177.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. — -y
Name: Matthew Timmons Signature: ��r�,.c z � —
Organization: TSI Energy Solutions
Digitally signed: 3111119 at 9:39 AM
Ekotrope RATER - Version 3.1.0.2128
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property
Organization
7243 BARKER ST
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: TALBOTT II
Community: LEGACY PRAIRIE 101
Builder
LENNAR HOMES
LP101 (AS DESIGNED)
LEGACY PRAIRIE 101
General Building Information
Conditioned Area (sq ft) 2,218
Conditioned Volume (cubic ft) 19,334
Insulated Shell Area (sq ft) 4,934
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: LOWER (449 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (4 63 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AMBIENT (30 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,393 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIAMB 2X6 (470 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
Organization
7243 BARKER ST
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: TALBOTT II
Community: LEGACY PRAIRIE 101
Builder
LENNAR HOMES
LP101 (AS DESIGNED)
LEGACY PRAIRIE 101
El Name: CONDIGAR 2X6 (192 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDICOND (790 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (105 s.f.)
R: 13.575
Name: CONDIGAR (24 s.f.)
R: 10.876
El Name: CONDICOND (76 s.f.)
R: 10.876
Roof
El Name: UPPER (942 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
J --G Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (114 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST
El Name: FRONT 2X6 (18 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization Inspection Status
7243 BARKER ST TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: TALBOTT II
Community: LEGACY PRAIRIE 101 Builder
LENNAR HOMES
LPI 01 (AS DESIGNED)
LEGACY PRAIRIE 101
E] Name: BACK (84 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST
E] Name: SLIDER (33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST
El Name: LEFT SIDE (66 s.f.), U:0.320, SHGC: 0.34, Orientation: SOUTH
El Name: LEFT SIDE 2X6 (45 s.f.), U:0.320, SHGC: 0.34, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE
Air conditioner {2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,933 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
7243 BARKER ST
CARMEL, IN 46033
Model: TALBOTT II
Community: LEGACY PRAIRIE 101
LP101 (AS DESIGNED)
LEGACY PRAIRIE 101
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 133.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 177.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
7243 BARKER ST
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: TALBOTT II
Yes
Community: LEGACY PRAIRIE 'I
guilder
Total Units in Building
LENNAR HOMES
LP101 [AS DESIGNED]
Townhouse; end unit
LEGACY PRAIRIE 101
TALBOTT II
Genera%uiiding Information
Number Of Bedrooms
3
Number Of Floors
3
Conditioned Floor Area [sq_ ft.]
2;218
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
19;334
Total Units in Building
1
Residence Type
Townhouse; end unit
Model
TALBOTT II
Community
LEGACY PRAIRIE 101
Climate Zone
5A
Basement Wall ,
None Present
Basement Wall Library List
None Present
Slab
C-M,
Energy Solutions
1P
Exposed Surface Area Location Enclosing
Masonry Area
LOWER R-10, 2'down 67 On Grade 123 0 449.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List "s W R
Name Wall Construction Type Slap Completely Underslalb Insulation Perimeter Insulation Perfineterinsufation R R -value
Insulated. Width [ft] Depth [Pt] Value
R-10, 2'down Wood Frame / Other No 0 2 1 D 0.00
1
Building Summary
Property
Organization
Inspection Status
C-MEnergy Solutions
7243 BARKER ST
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: TALBOTT II
Rim Joist
Community: LEGACY PRAIRIE 101
Builder
Name
Library Type
LENNAR HOMES
Location
CONDIAMB
LP101 [AS DESIGNED]
LEGACY PRAIRIE 101
105-0 sq. 1t.
Exposed Exterior
ramed Floor
G1 R-13, OSB
76-0 sq. 1t.
Name Library Type
Carpet R
Floor Grade
Surface Area Location
OVER AMBIENT R-38, GR1
1.23
Above Grade
30.0 sq. tt Exposed Exterior
OVER GARAGE R-38, GR1
1.23
Above Grade
463.0 sq. tt Unconditioned, attached
Rim Joist Library List
garage
Framed Floor Library List
Name
R -value
-'•s :»
33.825
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-13, R-3.0
105-0 sq. 1t.
Exposed Exterior
CONDJCOND
G1 R-13, OSB
76-0 sq. 1t.
Conditioned Space (Adiabatic)
CONDIGAR
G1 R-13, OSB
24-0 sq. 1t.
Unconditioned, attached garage
Rim Joist Library List
Name
R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
Name Library Type
CONDIAMB G1 R-13 BATT, R-3.0
:ONDIAMB 2X6 G1 R-13 BATT. R-3.0
Surface Calor
Medium
Medium
Surface Area
Location
1,393.0 sq. fl. Exposed Exterior
470.0 sq. ft. Exposed Exterior
Building Summary
Property Organization
7243 BARKER ST TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: TALBOTT II
Community: LEGACY PRAIRIE 101 Builder
LENNAR HOMES
LP101 (AS DESIGNED)
LEGACY PRAIRIE 101
Name Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDICOND
G1 R-22 Dbl Wall
Medium
790.0 sq. ft.
Conditioned Space (Adiabatic)
CONDIGAR 2X6
G1 R-19, OSB 2x6
Medium
192.0 sq. P[.
Unconditioned, attached garage
Wall Library List
Name
R -value
G1 R-13 BATT, R-3.0
15.12
G1 R-19, OSB 2x6
17.591
G1 R-22 Dbl Wall
18.407
Glazing
Name Library type Wall Assignment Basement Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation Surface Area
Assignment
Top
Hottom
BACK U-.32, SHGC-.34
CONDIAMB
0
0
0
West 84.0 sq. R
FRONT U-.32, SHGG.34
CONDIAMB
0
0
❑
East 114.0 sq. ft.
FRONT 2X6 U-.32, SHGG.34
CONDIAMB 2X6
0
0
0
East 18.0 sq. ft
LEFT SIDE U-.32, SHGG.34
CONDIAMB
0
0
0
South 66.0 sq. fL
LEFT SIDE 2X6 U-.32, SHGG.34
CONDIAMB 2X6
0
0
❑
South 45.0 sq. ft
SLIDER U-.32, SHGG.34
CONDIAMB
0
0
0
West 33.0 sq. ft
Glazing Library List
Name
Shg c
U -factor
U-.32, SHGC-.34
0.34
0.320
3
Building Summary
Property
7243 BARKER ST
CARMEL, IN 46033
Model: TALBOTT II
Community: LEGACY PRAIRIE 101
LP101 [AS DESIGNED]
LEGACY PRAIRIE 101
kyligh
Skylight Library List
Opaque Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Ab sorpta nce
FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.0 sq. it Exposed Exterior
GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior
Opaque Door Library List
Name U -factor
0.182
Roof Insulation
Name
imm
Library Typ
UPPER
R-38 Blown. GR1
krea Clay or Concrete Root
P.f.] Tiles
942 No
Roof Insulation Library List
Name Has Radiant Barrier R -value
'•0 �- -I :a l No 38268
n
Medium 942.0 sq. ft Attic
4
Building Summary
Property
7243 BARKER ST
CARMEL, IN 46033
Model: TALBOTT II
Community: LEGACY PRAIRIE 'I
LP101 [AS DESIGNED]
LEGACY PRAIRIE 101
FWhole House Infiltration
Infiltration
6 ACH at 50 Pa
Mechanical Ventilation
Lighting ,
°I Interior Fitiorescent
Lighting
Onsite Generation
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Blower -door tested 4
rang Y. txsenor rmorescem
Lighting
100 0
None Present
Onsite Generation Library List
None Present
Solar Generation
Solar Generation Library List
C-M,
Energy Solutions
Lighting
1❑0
Building Summary
Property
Organization
Inspection Status
7243 BARKER ST
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
PSG (Single Speed)
Model: TALBOTT II
92.1 AFUE
Heating Capacity [kBtulh]
Community: LEGACY PRAIRIE 'I
Builder
No
EAE [kWh]
LENNAR HOMES
Equipment Type: CA13NA0361,m
LP101 (AS DESIGNED)
Fuel Type
Electric
LEGACY PRAIRIE 101
Forced Air
Motor Type
onditioning Equipment
Cooling Efficiency
13 SEER
Name
Library Type
Heating Percent Load Co(
Air conditioner (2)
Equipment Type: RE350*
CA13NA036
0%
C-M,
Energy Solutions
g Percent Load Hot Water
100%
0%
Fuel4red air 912SA4808OS17 100% 0% 0%
distribution (1)
Water Heating (3) RE350" 0% 0% 100%
1
Equipment Type: 912SA4808OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
977
Equipment Type: CA13NA0361,m
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
34.2
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Building Summary
Property
7243 BARKER ST
CARMEL, IN 46033
Model: TALBOTT II
Community: LEGACY PRAIRIE 'I
LP101 [AS DESIGNED]
LEGACY PRAIRIE 101
1bution System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area [sq. ft.]
]uct Area [sq. ft_]
akage to Outdoors (CFM25)
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Ctm Per Watt
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
2218
2
3❑
3❑
449.1
166.4
133
177
Post -Construction
Yes
Conditioned Space
5❑
50
Attic (well vented; under insulation)
5❑
5❑
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
Organization Inspection Status
7243 BARKER ST
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: TALBOTT II
No
Community: LEGACY PRAIRIE 101
Builder
Recirculation System Pipe Loop Length [ft]
LENNAR HOMES
LP101 [AS DESIGNED]
No
LEGACY PRAIRIE 101
ater Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
84
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
r
othes Dryer
elType Electric
f 2.62
ld Utilization Timer Controls
Clothes Washer
ff"W
Label Energy Rating
704 kWh/Year
Electric Rate
0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
1 mef
0.331
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
TSI Energy Solutions
,�