Loading...
HomeMy WebLinkAboutLEGACY PRAIRIE 101 - LP101 (AS DESIGNED)IECC 2009 Performance Compliance Property 7243 BARKER ST CARMEL, IN 46033 Model: TALBOTT II Community: LEGACY PRAIRIE 101 LP101 (AS DESIGNED) LEGACY PRAIRIE 101 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cast IECC 2009 Performance $931 $133 $350 $1,414 $554 $0 $1,968 Requirements C-M, Energy Solutions As designed S775 S148 S350 $1,273 S554 SO $1,82T C4405.3 Performance-based compliance passes by 10.0% 402.4.12 Air Leakage Testing Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 10%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Signature: Organization: TSI Energy Solutions Digitally signed: 3/11119 at 9:39 AM Ekotrope RATER - Version 3.1.0.2128 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7243 BARKER ST IilriFri M CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.32, SHGC: 0.34 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 133.0 CFM @ 25Pa Total Duct Leakage 177.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. — -y Name: Matthew Timmons Signature: ��r�,.c z � — Organization: TSI Energy Solutions Digitally signed: 3111119 at 9:39 AM Ekotrope RATER - Version 3.1.0.2128 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 7243 BARKER ST TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Community: LEGACY PRAIRIE 101 Builder LENNAR HOMES LP101 (AS DESIGNED) LEGACY PRAIRIE 101 General Building Information Conditioned Area (sq ft) 2,218 Conditioned Volume (cubic ft) 19,334 Insulated Shell Area (sq ft) 4,934 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: LOWER (449 s.f.) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (4 63 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I El Name: OVER AMBIENT (30 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (1,393 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIAMB 2X6 (470 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 7243 BARKER ST TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Community: LEGACY PRAIRIE 101 Builder LENNAR HOMES LP101 (AS DESIGNED) LEGACY PRAIRIE 101 El Name: CONDIGAR 2X6 (192 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDICOND (790 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (105 s.f.) R: 13.575 Name: CONDIGAR (24 s.f.) R: 10.876 El Name: CONDICOND (76 s.f.) R: 10.876 Roof El Name: UPPER (942 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door J --G Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (114 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST El Name: FRONT 2X6 (18 s.f.), U: 0.320, SHGC: 0.34, Orientation: EAST C-M, Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 7243 BARKER ST TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Community: LEGACY PRAIRIE 101 Builder LENNAR HOMES LPI 01 (AS DESIGNED) LEGACY PRAIRIE 101 E] Name: BACK (84 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST E] Name: SLIDER (33 s.f.), U:0.320, SHGC: 0.34, Orientation: WEST El Name: LEFT SIDE (66 s.f.), U:0.320, SHGC: 0.34, Orientation: SOUTH El Name: LEFT SIDE 2X6 (45 s.f.), U:0.320, SHGC: 0.34, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner {2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,933 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 7243 BARKER ST CARMEL, IN 46033 Model: TALBOTT II Community: LEGACY PRAIRIE 101 LP101 (AS DESIGNED) LEGACY PRAIRIE 101 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 133.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 177.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 7243 BARKER ST TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Yes Community: LEGACY PRAIRIE 'I guilder Total Units in Building LENNAR HOMES LP101 [AS DESIGNED] Townhouse; end unit LEGACY PRAIRIE 101 TALBOTT II Genera%uiiding Information Number Of Bedrooms 3 Number Of Floors 3 Conditioned Floor Area [sq_ ft.] 2;218 Unconditioned, attached garage? Yes Conditioned Volume [cu. ft.] 19;334 Total Units in Building 1 Residence Type Townhouse; end unit Model TALBOTT II Community LEGACY PRAIRIE 101 Climate Zone 5A Basement Wall , None Present Basement Wall Library List None Present Slab C-M, Energy Solutions 1P Exposed Surface Area Location Enclosing Masonry Area LOWER R-10, 2'down 67 On Grade 123 0 449.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List "s W R Name Wall Construction Type Slap Completely Underslalb Insulation Perimeter Insulation Perfineterinsufation R R -value Insulated. Width [ft] Depth [Pt] Value R-10, 2'down Wood Frame / Other No 0 2 1 D 0.00 1 Building Summary Property Organization Inspection Status C-MEnergy Solutions 7243 BARKER ST TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Rim Joist Community: LEGACY PRAIRIE 101 Builder Name Library Type LENNAR HOMES Location CONDIAMB LP101 [AS DESIGNED] LEGACY PRAIRIE 101 105-0 sq. 1t. Exposed Exterior ramed Floor G1 R-13, OSB 76-0 sq. 1t. Name Library Type Carpet R Floor Grade Surface Area Location OVER AMBIENT R-38, GR1 1.23 Above Grade 30.0 sq. tt Exposed Exterior OVER GARAGE R-38, GR1 1.23 Above Grade 463.0 sq. tt Unconditioned, attached Rim Joist Library List garage Framed Floor Library List Name R -value -'•s :» 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 105-0 sq. 1t. Exposed Exterior CONDJCOND G1 R-13, OSB 76-0 sq. 1t. Conditioned Space (Adiabatic) CONDIGAR G1 R-13, OSB 24-0 sq. 1t. Unconditioned, attached garage Rim Joist Library List Name R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Name Library Type CONDIAMB G1 R-13 BATT, R-3.0 :ONDIAMB 2X6 G1 R-13 BATT. R-3.0 Surface Calor Medium Medium Surface Area Location 1,393.0 sq. fl. Exposed Exterior 470.0 sq. ft. Exposed Exterior Building Summary Property Organization 7243 BARKER ST TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II Community: LEGACY PRAIRIE 101 Builder LENNAR HOMES LP101 (AS DESIGNED) LEGACY PRAIRIE 101 Name Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDICOND G1 R-22 Dbl Wall Medium 790.0 sq. ft. Conditioned Space (Adiabatic) CONDIGAR 2X6 G1 R-19, OSB 2x6 Medium 192.0 sq. P[. Unconditioned, attached garage Wall Library List Name R -value G1 R-13 BATT, R-3.0 15.12 G1 R-19, OSB 2x6 17.591 G1 R-22 Dbl Wall 18.407 Glazing Name Library type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Hottom BACK U-.32, SHGC-.34 CONDIAMB 0 0 0 West 84.0 sq. R FRONT U-.32, SHGG.34 CONDIAMB 0 0 ❑ East 114.0 sq. ft. FRONT 2X6 U-.32, SHGG.34 CONDIAMB 2X6 0 0 0 East 18.0 sq. ft LEFT SIDE U-.32, SHGG.34 CONDIAMB 0 0 0 South 66.0 sq. fL LEFT SIDE 2X6 U-.32, SHGG.34 CONDIAMB 2X6 0 0 ❑ South 45.0 sq. ft SLIDER U-.32, SHGG.34 CONDIAMB 0 0 0 West 33.0 sq. ft Glazing Library List Name Shg c U -factor U-.32, SHGC-.34 0.34 0.320 3 Building Summary Property 7243 BARKER ST CARMEL, IN 46033 Model: TALBOTT II Community: LEGACY PRAIRIE 101 LP101 [AS DESIGNED] LEGACY PRAIRIE 101 kyligh Skylight Library List Opaque Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 20.0 sq. it Exposed Exterior GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Opaque Door Library List Name U -factor 0.182 Roof Insulation Name imm Library Typ UPPER R-38 Blown. GR1 krea Clay or Concrete Root P.f.] Tiles 942 No Roof Insulation Library List Name Has Radiant Barrier R -value '•0 �- -I :a l No 38268 n Medium 942.0 sq. ft Attic 4 Building Summary Property 7243 BARKER ST CARMEL, IN 46033 Model: TALBOTT II Community: LEGACY PRAIRIE 'I LP101 [AS DESIGNED] LEGACY PRAIRIE 101 FWhole House Infiltration Infiltration 6 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fitiorescent Lighting Onsite Generation Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Blower -door tested 4 rang Y. txsenor rmorescem Lighting 100 0 None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List C-M, Energy Solutions Lighting 1❑0 Building Summary Property Organization Inspection Status 7243 BARKER ST TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons PSG (Single Speed) Model: TALBOTT II 92.1 AFUE Heating Capacity [kBtulh] Community: LEGACY PRAIRIE 'I Builder No EAE [kWh] LENNAR HOMES Equipment Type: CA13NA0361,m LP101 (AS DESIGNED) Fuel Type Electric LEGACY PRAIRIE 101 Forced Air Motor Type onditioning Equipment Cooling Efficiency 13 SEER Name Library Type Heating Percent Load Co( Air conditioner (2) Equipment Type: RE350* CA13NA036 0% C-M, Energy Solutions g Percent Load Hot Water 100% 0% Fuel4red air 912SA4808OS17 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% 1 Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA0361,m Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 34.2 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property 7243 BARKER ST CARMEL, IN 46033 Model: TALBOTT II Community: LEGACY PRAIRIE 'I LP101 [AS DESIGNED] LEGACY PRAIRIE 101 1bution System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 2218 2 3❑ 3❑ 449.1 166.4 133 177 Post -Construction Yes Conditioned Space 5❑ 50 Attic (well vented; under insulation) 5❑ 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property Organization Inspection Status 7243 BARKER ST TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: TALBOTT II No Community: LEGACY PRAIRIE 101 Builder Recirculation System Pipe Loop Length [ft] LENNAR HOMES LP101 [AS DESIGNED] No LEGACY PRAIRIE 101 ater Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 84 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No r othes Dryer elType Electric f 2.62 ld Utilization Timer Controls Clothes Washer ff"W Label Energy Rating 704 kWh/Year Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 1 mef 0.331 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Yes Standard 270 kWh Electric No No 709 kWh/Year "M � TSI Energy Solutions ,�