MATCH LINE C800
MATCH LINE C801
GENERAL UTILITY NOTES
1.THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND
LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL
CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN
CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES
WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
2.THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE
LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE
VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS
EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE
SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED.
3.THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS,
CONDUITS, SERVICE LINES, ETC. WITHIN THE CONSTRUCTION LIMITS. THE
LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND
MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE
UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR.
4.THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY
AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES.
5.ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH
O.S.H.A. STANDARDS FOR WORKER SAFETY.
6.ANY PART OF SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR
WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL.
7.IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND
ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS, ETC. AS
RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR
DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS.
8.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL CLEARANCE BETWEEN STORM /
SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE. SANITARY
SEWER LINE IN PROXIMITY OF WATER LINE SHALL BE C900 WATER MAIN GRADE
PVC.
9.CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL
SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN
SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS.
10.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING
CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR
AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO
EXISTING CONDITIONS OR BETTER.
11.WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER,
PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER
MANAGEMENT TO CONTROL MOISTURE OF SOILS.
12.COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED
AREAS.
13.ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT
AND SHALL HAVE TRAFFIC BEARING RING AND COVERS.
14.PROVIDE THRUST BLOCKS FOR ALL WATER LINE BENDS AND TEES, INCLUDING
TAP CONNECTION.
15.CONTRACTOR SHALL COORDINATE WITH WATER COMPANY FOR DOMESTIC AND
FIRE SERVICE. CONNECT TO BUILDING DOMESTIC AND FIRE LINE. COORDINATE
WITH PLUMBING DRAWINGS.
16.COORDINATE LOCATION OF ELECTRICAL AND COMMUNICATION LINES WITH
LOCAL UTILITIES.
17.COORDINATE LOCATION OF REQUIRED CONDUITS FOR ELECTRIC SERVICE, LIGHT
POLES, COMMUNICATION SERVICE AND IRRIGATION SYSTEM.
18.COORDINATE LOCATION AND SIZE OF GAS SERVICE CONNECTION AND
INSTALLATION OF SERVICE LINE AND METER WITH GAS COMPANY.
19.COORDINATE LOCATIONS AND CONNECTIONS OF BUILDING STORM LINES WITH
PLUMBING DRAWINGS.
20.FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO DOMESTIC/FIRE LINE
INSTALLATION AND STORM SEWER / SANITARY SEWER INSTALLATION.
21.SANITARY SEWER LATERAL, WATER SERVICE, & ELECTRICAL/COMMUNICATION
CONDUITS SHALL BE GRANULAR BACKFILL FOR ENTIRE RUN.
22.ALL EXISTING MANHOLE AND CATCH BASIN GRATES, WATER OR GAS VALVES
SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS.
UTILITY PLAN NOTES
SANITARY SEWER NOTES
CONNECT 6" SANITARY SEWER LATERAL TO BUILDING SEWER.
COORDINATE WITH MEP DRAWINGS.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 1 (WITHIN 3' OF
BUILDING). REFER TO DETAIL ON SHEET C802.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 2 (IN PAVED AREAS
OUTSIDE OF 3' OF BUILDING). REFER TO DETAIL ON SHEET C802.
PROPOSED SANITARY LATERAL CLEANOUT TYPE 3 (IN NON-PAVED
AREAS ONLY). REFER TO DETAIL ON SHEET C802.
PROVIDE 18" MINIMUM VERTICAL CLEARANCE BETWEEN
SANITARY/WATER/STORM SEWER PIPES AND ALL OTHER PIPES.
PROPOSED SANITARY GRINDER STATION AND 2" PE DR11 FORCE
MAIN. REFER TO SHEETS C500-C502 FOR DETAILS AND
SPECIFICATIONS.
WATER SERVICE NOTES:
COORDINATE AND CONNECT 6" FIRE SERVICE LINE TO PROPOSED 12"
PVC WATER MAIN. CITY OF CARMEL TO PROVIDE 12" MAIN, 12"x6" TEE
AND 6" GATE VALVE.
COORDINATE CONNECTION OF DOMESTIC SERVICE LINE WITH
PLUMBING DRAWINGS.
COORDINATE CONNECTION OF DOMESTIC METER LOCATION WITH
LOCAL SERVICE PROVIDER. 1 1/2" WATER METER SET W/ BACKFLOW
PREVENTION INSIDE THE BUILDING ANTICIPATED.
EXISTING FIRE HYDRANT.
PROPOSED FIRE HYDRANT ASSEMBLY. REFER TO DETAIL ON SHEET
C802.
PROPOSED 2" ISOLATION VALVE.
PROPOSED 6" PVC C900 FIRE SERVICE LINE.
PROPOSED 2" PE DOMESTIC SERVICE LINE.
COORDINATE AND CONNECT 1" DOMESTIC SERVICE LINE TO
PROPOSED 12" PVC WATER MAIN (BY CITY OF CARMEL)
COORDINATE CONNECTION OF DOMESTIC WATER METER LOCATION
WITH LOCAL SERVICE PROVIDER. 5/8" METER SET WITH BACK-FLOW
PREVENTION INSIDE THE BUILDING ANTICIPATED.
1" ISOLATION VALVE.
PROPOSED 1" PE DOMESTIC SERVICE LINE.
CONNECT NEW SERVICE LINE TO EXISTING SERVICE LINE FROM WELL.
INSTALL BACK-FLOW PREVENTION INSIDE THE BUILDING.
COORDINATE WITH LOCAL SERVICE PROVIDER.
ELECTRIC NOTES:
COORDINATE AND CONNECT BUILDING ELECTRICAL LINE FROM
SERVICE DROP LOCATION TO TRANSFORMER. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED. 2-4" EC CONDUITS TO BE INSTALLED WITH
PULL STRINGS. 208/230V REQUIRED.
PROPOSED TRANSFORMER PAD LOCATION. COORDINATE WITH
UTILITY PROVIDER.
BUILDING ELECTRICAL LINE POINT OF CONNECTION. COORDINATE
CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS.
ADJUST AS REQUIRED.
COMMUNICATION NOTES:
COORDINATE AND CONNECT BUILDING COMMUNICATION SERVICE
LINE(S) TO CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED
AND COORDINATE WITH MEP DRAWINGS. ONE 4" PVC CONDUIT TO BE
INSTALLED WITH PULL STRINGS. COORDINATE WITH OWNER FOR
NUMBER OF LINES ANTICIPATED FOR SERVICE.
COORDINATE OFFSITE CONNECTION POINT WITH SERVICE PROVIDER.
GAS SERVICE NOTES:
CONNECT PROPOSED GAS SERVICE TO EXISTING GAS LINE. REFER
TO PLUMBING DRAWINGS AND COORDINATE WITH SERVICE
PROVIDER.
PROPOSED GAS METER LOCATION. REFER TO PLUMBING DRAWINGS
AND COORDINATE WITH SERVICE PROVIDER.
STORM NOTES:
12" SLOTTED DRAIN. REFER TO SHEET C603.
15'-4" HDPE DUAL WALL PERFORATED UNDERDRAIN. REFER TO SHEET
C603.
W4
W2
W3
S3
S2
W1
S4
E1
E2
C1
G1
S5
S1
S6
W5
W6
W7
W8
W9
W10
C800UTILITY PLANGUY ANCHOR
ELECTRIC JUNCTION BOX
GENERATOR
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
BOUNDARY LINE
FIRE HYDRANT
WELL HEAD
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
TRAFFIC SIGNAL POLE
TRAFFIC SIGNALDOWN SPOUT
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
PARKING LOT LIGHT (1 HEAD)
PARKING LOT LIGHT (2 HEAD)
R/W RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
UTILITY PLAN LEGEND
UTILITIES
ABBREVIATIONS
LINE TYPES
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E E E
C C C
OHU OHU
FM FM
UNDERGROUND FIBER OPTICFOFO
SANITARY SEWER LATERALSANSAN
ROOF DRAINSTMSTM
SUB SURFACE DRAIN
W11
C2
G2
E3
REVISIONS AND ISSUESPart of Section 9, Township 17 North, Range 4 East, Clay Township, Hamilton County, IndianaW19.3004PREPARED FOR:5140 E 96TH ST, INDIANAPOLIS, IN 46240PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JLKDESIGNED BY:DWG NAME:PROJECT NO.:W19.03004DATEBY05.15.2019FAPDATE:FAPKnow what's below.