39GO - Trusses
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). March 26,2019 Liu, Xuegang Pages or sheets covered by this seal: I36525856 thru I36525931 My license renewal date for the state of Indiana is July 31, 2020. B19901019 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: Wedgewood 39 Gray Oaks 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525856 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-pWTU5RGQpElfq0Q?b5760SujHEKsgNi5mwmJ?0zX3hA Scale = 1:92.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 4x8 4x6 4x6 3x4 3x4 3x6 6x6 5x6 8x8 5x6 5x6 52-2-8 52-2-8 -1-2-8 1-2-8 14-9-8 14-9-8 38-10-11 24-1-3 52-2-8 13-3-13 0-10-1412-0-02-0-212-0-09.00 12 Plate Offsets (X,Y)-- [2:0-1-5,0-1-12], [14:0-3-0,0-3-4], [26:0-4-0,0-4-8], [32:0-3-0,0-3-4], [56:0-3-0,0-3-0], [65:0-3-0,0-3-0], [72:0-1-11,0-1-8], [84:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.37 0.11 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 0.00 0.00 (loc) 1 1 44 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 536 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 *Except* 10-77,8-78,7-79,6-80,5-81,4-82,3-83,36-50,38-49,39-48,40-47,41-46 ,42-45: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 14-32. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 32-54, 31-55, 30-56, 29-57, 28-58, 27-59, 26-60, 25-61, 24-62, 23-63, 22-64, 21-65, 20-66, 19-67, 18-68, 17-69, 16-70, 15-71, 14-73, 13-74, 12-75, 11-76, 33-53, 34-52, 35-51 REACTIONS.All bearings 52-2-8. (lb) - Max Horz 84=305(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 44, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 52, 51, 50, 49, 48, 47, 46, 45 except 84=-250(LC 4), 83=-155(LC 5) Max Grav All reactions 250 lb or less at joint(s) 44, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 53, 52, 51, 50, 49, 48, 47, 46, 45 except 84=295(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-340/311, 3-4=-265/262, 4-5=-243/263, 5-6=-218/260, 6-7=-192/257, 7-8=-167/253, 10-11=-116/267, 11-12=-89/297, 12-13=-64/327, 13-14=-37/326, 14-15=-17/287, 15-16=-16/286, 16-17=-16/286, 17-18=-16/286, 18-19=-16/286, 19-20=-16/286, 20-21=-16/286, 21-22=-16/286, 22-23=-16/286, 23-24=-16/286, 24-25=-16/286, 25-26=-16/286, 26-27=-17/286, 27-28=-17/286, 28-29=-17/286, 29-30=-17/286, 30-31=-16/286, 31-32=-17/287, 32-33=-29/322, 33-34=-28/311, 34-35=-29/271 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Continued on page 2 March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525856 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:24 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-Hi1sImH2aYtWRA?B9oeLZfRu1ef5PqyF?aVsYTzX3h9 NOTES- 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 44, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 52, 51, 50, 49, 48, 47, 46, 45 except (jt=lb) 84=250, 83=155. 12) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE02 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525857 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-lubEW6IgLs?N3KaNiW9a5tz111zP8BsOEDFQ4vzX3h8 Scale = 1:74.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 28 29 30 3x4 3x6 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-11-0 15-11-0 -1-2-8 1-2-8 7-11-8 7-11-8 15-11-0 7-11-8 17-1-8 1-2-8 1-5-910-9-01-5-914.00 12 Plate Offsets (X,Y)-- [8:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.48 0.23 0.45 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 15 15 16 15 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 118 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 7-22,9-21: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 28, 29, 30 REACTIONS.All bearings 15-11-0. (lb) - Max Horz 27=-272(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 24, 25, 19, 18 except 27=-221(LC 4), 16=-203(LC 5), 23=-114(LC 6), 26=-275(LC 5), 20=-115(LC 7), 17=-264(LC 4) Max Grav All reactions 250 lb or less at joint(s) 22, 23, 24, 25, 26, 21, 20, 19, 18, 17 except 27=346(LC 5), 16=329(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-262/197, 6-7=-29/266, 9-10=-29/266 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 25, 19, 18 except (jt=lb) 27=221, 16=203, 23=114, 26=275, 20=115, 17=264. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE03 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525858 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-hHj?xoJwsTF5IdkmqxB2AI3ToriDc7whhXkW8ozX3h6 Scale = 1:70.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 54 53 52 51 50 49 48 47 46 45 44 43 4241 40 39 38 37 36 35 34 33 32 31 30 29 28 55 3x6 3x4 3x4 3x4 5x6 3x6 3x4 32-7-8 32-7-8 10-9-8 10-9-8 32-7-8 21-10-0 3-10-1412-0-09.00 12 Plate Offsets (X,Y)-- [9:0-2-0,0-2-0], [37:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.08 0.02 0.28 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 28 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 367 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 27-28: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 5-49,4-50,3-51,2-52,53-55: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 9-27. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 27-28, 26-29, 25-30, 24-31, 23-32, 21-33, 20-34, 19-35, 18-36, 17-37, 16-38, 15-39, 14-40, 13-41, 12-42, 11-43, 10-45, 8-46, 7-47, 6-48 REACTIONS.All bearings 32-7-8. (lb) - Max Horz 54=248(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 54, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 48, 49, 50, 51 except 52=-572(LC 6) Max Grav All reactions 250 lb or less at joint(s) 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 48, 49, 50, 51, 52, 53 except 54=570(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-54=-551/37, 1-2=-289/36 WEBS 1-55=-41/466, 52-55=-50/588 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 54, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 48, 49, 50, 51 except (jt=lb) 52=572. 11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525859 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-9TGN88KZdnNywnJyOeiHjVbdmF00LciqwBT4hEzX3h5 Scale = 1:75.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x6 3x6 4x6 3x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 19-6-8 19-6-8 -1-2-8 1-2-8 9-9-4 9-9-4 19-6-8 9-9-4 20-9-0 1-2-8 1-2-1411-0-21-2-1412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.19 0.17 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 17 17 18 17 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 145 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 9-25,8-26,10-24: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-25, 8-26, 10-24 REACTIONS.All bearings 19-6-8. (lb) - Max Horz 33=-266(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 26, 27, 28, 29, 31, 24, 23, 22, 21, 20 except 33=-201(LC 4), 18=-165(LC 5), 32=-213(LC 5), 19=-190(LC 4) Max Grav All reactions 250 lb or less at joint(s) 18, 26, 27, 28, 29, 31, 32, 24, 23, 22, 21, 20, 19 except 33=261(LC 5), 25=340(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-11/276, 8-9=-17/298, 9-10=-17/298, 10-11=-11/276 WEBS 9-25=-358/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 27, 28, 29, 31, 24, 23, 22, 21, 20 except (jt=lb) 33=201, 18=165, 32=213, 19=190. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE05 Truss Type GABLE COMMON Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525860 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-6sO7ZqMp9OdgA5SLV3llowhtL2ZwpNq7OVyBl7zX3h3 Scale = 1:75.9 1 2 3 4 5 6 7 8 9 10 11 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 52 53 57 54 55 56 5x6 4x6 4x6 5x6 3x4 3x8 3x8 3x8 3x4 3x4 5x6 3x6 3x8 10-9-2 10-9-2 13-11-0 3-1-14 16-5-6 2-6-6 22-1-10 5-8-4 32-10-12 10-9-2 -1-2-8 1-2-8 5-5-13 5-5-13 10-9-2 5-3-5 16-5-6 5-8-4 22-1-10 5-8-4 27-4-15 5-3-5 32-10-12 5-5-13 34-1-4 1-2-8 1-2-1412-0-01-2-1412-0-012.00 12 Plate Offsets (X,Y)-- [3:0-0-0,0-1-12], [3:0-1-12,0-3-4], [5:0-4-4,0-1-12], [7:0-4-4,0-1-12], [9:0-0-0,0-1-12], [9:0-1-12,0-3-0], [35:0-1-13,0-1-0], [37:0-1-13,0-1-0], [39:0-1-13 ,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.57 0.66 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.32 -0.71 0.02 0.01 (loc) 12-13 12-13 12 13-15 l/defl >719 >319 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 292 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 14-18: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-19,8-13,4-27,8-12: 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 28-30,33-34,35-36,46-47,50-51: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-19, 5-19, 6-19, 6-13, 8-13, 4-27, 8-12 REACTIONS.All bearings 13-11-0 except (jt=length) 12=0-10-0, 16=0-3-8, 16=0-3-8. (lb) - Max Horz 27=287(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 27, 12, 17, 26 except 19=-147(LC 5) Max Grav All reactions 250 lb or less at joint(s) 17, 20, 21, 22, 23, 24, 25, 26, 16, 16 except 19=1450(LC 1), 27=363(LC 10), 12=1095(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-495/205, 7-8=-821/212, 8-10=-516/157, 2-27=-289/215, 10-12=-523/182 BOT CHORD 17-19=-78/339, 16-17=-78/339, 15-16=-78/339, 13-15=-78/339, 12-13=0/619 WEBS 5-19=-369/72, 6-19=-945/131, 6-13=-5/374, 8-12=-517/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 12, 17, 26 except (jt=lb) 19=147. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525861 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2FWt_WN3h?tOPOcjdUnDtLm8dsJpHG7QrpRHq?zX3h1 Scale = 1:84.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 28 29 30 3x6 3x8 4x6 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-11-0 15-11-0 -1-2-8 1-2-8 7-11-8 7-11-8 15-11-0 7-11-8 17-1-8 1-2-8 3-0-1112-4-23-0-1114.00 12 Plate Offsets (X,Y)-- [8:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.84 0.44 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 15 14-15 16 15 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 140 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 7-22,6-23,9-21,10-20: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-23, 10-20 JOINTS 1 Brace at Jt(s): 28, 29, 30 REACTIONS.All bearings 15-11-0. (lb) - Max Horz 27=326(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 24, 25, 19, 18 except 27=-527(LC 4), 16=-520(LC 5), 23=-150(LC 6), 26=-526(LC 5), 20=-150(LC 7), 17=-520(LC 4) Max Grav All reactions 250 lb or less at joint(s) 23, 24, 25, 20, 19, 18 except 27=521(LC 5), 16=514(LC 4), 22=348(LC 7), 26=506(LC 4), 21=347(LC 6), 17=500(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-27=-276/322, 2-3=-277/338, 4-5=-41/289, 5-6=-28/360, 6-7=-25/512, 7-8=-46/349, 8-9=-46/349, 9-10=-25/512, 10-11=-28/360, 11-12=-38/289, 13-14=-272/333, 14-16=-272/318 WEBS 8-28=-320/0, 22-29=-388/0, 3-26=-234/251, 21-30=-388/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 25, 19, 18 except (jt=lb) 27=527, 16=520, 23=150, 26=526, 20=150, 17=520. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525862 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-WR4GBrOhSJ?F1YBwABISQZJVbGlD0u7Z4TBrMRzX3h0 Scale = 1:56.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 21-11-0 21-11-0 -1-2-8 1-2-8 10-11-8 10-11-8 21-11-0 10-11-8 23-1-8 1-2-8 0-6-08-8-100-6-09.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-5], [18:0-0-0,0-0-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.12 0.04 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.01 0.01 0.01 (loc) 19 19 18 19 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 10-27: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-27 REACTIONS.All bearings 21-11-0. (lb) - Max Horz 2=198(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 27, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE08 Truss Type Half Hip Supported Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525863 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-_deePBPJDd76eim6kvphymreVg4alMljI7wOuuzX3h? Scale = 1:18.5 1 2 3 4 7 6 5 2x4 3x4 4x6 2x4 2x4 2x4 2-0-0 2-0-0 -1-2-8 1-2-8 0-8-14 0-8-14 2-0-0 1-3-2 2-6-03-0-119.00 12 Plate Offsets (X,Y)-- [3:0-3-12,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.24 0.10 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.01 0.00 0.00 (loc) 1 1 5 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)7=170/2-0-0, 5=31/2-0-0, 6=18/2-0-0 Max Horz 7=94(LC 5) Max Uplift 7=-81(LC 4), 5=-68(LC 5), 6=-51(LC 5) Max Grav 7=170(LC 1), 5=31(LC 4), 6=52(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -1-2-8 to 1-10-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5, 6. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE09 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525864 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-SpB0cXQy_wFyGsLIIcKwV_Oha3MPUoesXngyQKzX3h_ Scale = 1:69.8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 3x4 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-9-0 15-9-0 15-9-0 15-9-0 0-0-411-9-129.00 12 Plate Offsets (X,Y)-- [13:0-4-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.67 0.38 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-8: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 12-15,11-16,10-17: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-14, 12-15, 11-16, 10-17 REACTIONS.All bearings 15-9-0. (lb) - Max Horz 1=343(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 Max Grav All reactions 250 lb or less at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-329/178, 2-3=-298/169, 3-4=-277/167, 4-5=-255/164 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 1, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE10 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525865 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-SpB0cXQy_wFyGsLIIcKwV_On83QRUpfsXngyQKzX3h_ Scale = 1:28.3 1 2 4 3 2x4 3x6 2x4 3x4 3-5-12 3-5-12 3-5-12 3-5-12 2-4-125-0-19.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.31 0.12 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.00 0.00 (loc) 3-4 3-4 3 4 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=128/0-3-8, 3=128/0-3-8 Max Horz 4=135(LC 5) Max Uplift 4=-38(LC 4), 3=-87(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss GE11 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525866 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-w0lOptQalENpu0wVsJr92Bw?LTmrDG80mRPVymzX3gz Scale = 1:15.4 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 3-3-13 3-3-13 0-0-42-5-149.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.09 0.05 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=50/3-3-13, 4=32/3-3-13, 5=137/3-3-13 Max Horz 1=62(LC 5) Max Uplift 1=-1(LC 4), 4=-11(LC 5), 5=-41(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss M01 Truss Type Monopitch Qty 2 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525867 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-OCJm1DRCWYWgVAVhP1NOaPT6yt2Wydb9?592UDzX3gy Scale = 1:54.8 1 2 4 3 5 6 3x6 5x6 3x4 2x4 3x4 3x4 5-4-0 5-4-0 5-4-0 5-4-0 3-4-39-6-141-7-29-6-1414.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.35 0.27 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.03 -0.08 -0.09 0.01 (loc) 3-4 3-4 6 3 l/defl >999 >738 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=202/Mechanical, 6=181/0-3-0 Max Horz 4=173(LC 6) Max Uplift 6=-218(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-6=-182/289 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=218. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss M02 Truss Type MONOPITCH Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525868 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-tOt9EZSqHreX7J4tzkud7c0KHHSYhAZJDluc0fzX3gx Scale = 1:23.4 1 2 3 5 4 2x4 2x4 3x6 3x4 2-0-0 2-0-0 -1-2-8 1-2-8 2-0-0 2-0-0 2-6-04-0-03-8-80-3-84-0-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.19 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 5 4-5 4 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=182/0-3-8, 4=36/0-1-8 Max Horz 5=118(LC 5) Max Uplift 5=-64(LC 4), 4=-118(LC 5) Max Grav 5=182(LC 1), 4=110(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 4=118. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss M03 Truss Type MONOPITCH Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525869 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-tOt9EZSqHreX7J4tzkud7c09nHLXh8EJDluc0fzX3gx Scale = 1:47.2 1 2 4 3 6x6 3x6 3x4 3x4 7-10-8 7-10-8 7-10-8 7-10-8 2-2-28-1-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.86 0.48 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.14 -0.34 -0.00 -0.01 (loc) 3-4 3-4 3 3-4 l/defl >655 >269 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3 REACTIONS.(lb/size)3=305/0-3-8, 4=305/0-3-8 Max Horz 4=177(LC 6) Max Uplift 3=-138(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=138. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss M04 Truss Type MONOPITCH Qty 5 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525870 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-LbRXSvTS29mOlTe4XSPsfqYKfhiIQb9SSPe9Y5zX3gw Scale = 1:47.2 1 2 4 3 6x6 3x4 3x4 3x4 7-7-0 7-7-0 7-7-0 7-7-0 2-4-128-1-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.85 0.45 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.12 -0.29 -0.00 -0.01 (loc) 3-4 3-4 3 3-4 l/defl >726 >299 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3 REACTIONS.(lb/size)3=293/0-3-8, 4=293/Mechanical Max Horz 4=170(LC 6) Max Uplift 3=-139(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=139. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss M05 Truss Type Monopitch Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525871 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-pn?vfFT4pTuFMdDG59w5C15fz46B948bh3Ni5XzX3gv Scale = 1:29.4 1 2 4 3 3x6 2x4 3x4 2x4 3-9-4 3-9-4 3-9-4 3-9-4 2-4-125-2-119.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.24 0.15 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 -0.00 0.00 (loc) 3-4 3-4 3 4 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=141/0-3-8, 4=141/Mechanical Max Horz 4=82(LC 6) Max Uplift 3=-93(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 2 Wedgewood 39 Gray Oaks Job Reference (optional) I36525872 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 14:01:44 2019 Page 1 ID:CEuqc7_6VX2rPZi213Y_20yigU4-tycuRBFDrxo1D9WBH_kUHteh7q2WNNj_gr2pgjzX25b Scale = 1:92.4 1 2 3 4 5 9 8 7 6101112131415 16 3x4 2x4 5x6 4x10 5x6 5x6 6x6 5x12 3x12 12x12 8x10 4-8-13 4-8-13 9-2-3 4-5-5 13-11-0 4-8-13 4-8-13 4-8-13 9-2-3 4-5-5 13-11-0 4-8-13 1-2-1415-1-1412.00 12 Plate Offsets (X,Y)-- [1:0-8-5,0-4-3], [7:0-3-8,0-6-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.38 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.16 0.01 0.02 (loc) 7-8 7-8 6 7-8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 258 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud, 4-6: 2x4 SPF 2100F 1.8E SLIDER Left 2x10 SP No.1 3-0-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 4-6 REACTIONS.(lb/size)6=7407/0-3-8, 1=6115/0-3-8 Max Horz 1=448(LC 5) Max Uplift 6=-174(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-6030/0, 2-3=-3269/0, 3-4=-3099/0 BOT CHORD 1-10=0/3880, 9-10=0/3880, 9-11=0/3880, 8-11=0/3880, 8-12=0/3880, 12-13=0/3880, 7-13=0/3880, 7-14=-12/2252, 14-15=-12/2252, 15-16=-12/2252, 6-16=-12/2252 WEBS 2-8=0/3964, 2-7=-2580/0, 4-7=0/6791, 4-6=-5347/24 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1635 lb down at 1-4-12, 1635 lb down at 3-4-12, 1635 lb down at 5-4-12, 1863 lb down and 58 lb up at 7-4-12, 1842 lb down and 58 lb up at 9-4-12, and 1833 lb down and 58 lb up at 11-4-12, and 1869 lb down and 55 lb up at 13-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 1-7=-20, 7-15=-60, 6-15=-20 Continued on page 2 March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 2 Wedgewood 39 Gray Oaks Job Reference (optional) I36525872 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 14:01:44 2019 Page 2 ID:CEuqc7_6VX2rPZi213Y_20yigU4-tycuRBFDrxo1D9WBH_kUHteh7q2WNNj_gr2pgjzX25b LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=-1842 10=-1635(B) 11=-1635(B) 12=-1635(B) 13=-1863 14=-1833 16=-1869 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB01 Truss Type Piggyback Qty 12 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525873 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-HzZHtaUjZm06_noSetRKlFermUSCuUilvj7Gd_zX3gu Scale = 1:57.0 1 2 3 4 5 6 7 8 9 15 14 13 12 11 101617 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 24-1-3 24-1-3 12-0-10 12-0-10 24-1-3 12-0-10 0-4-108-10-150-1-80-4-100-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.17 0.16 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.01 -0.00 (loc) 9 9 8 8 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 79 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.All bearings 22-8-14. (lb) - Max Horz 2=-200(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 15, 10 except 13=-106(LC 6), 11=-106(LC 7) Max Grav All reactions 250 lb or less at joint(s) 2, 8 except 12=396(LC 1), 13=494(LC 10), 15=343(LC 1), 11=494(LC 11), 10=343(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-13=-261/155, 6-11=-261/155 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15, 10 except (jt=lb) 13=106, 11=106. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB02 Truss Type Piggyback Qty 8 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525874 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-DMg2IGWz5OGqD5yrmIToqgjARI7OMND2N1cNhszX3gs Scale = 1:53.1 1 2 3 4 5 6 10 9 8 711 4x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 16-0-8 16-0-8 12-0-10 12-0-10 16-0-8 3-11-15 0-4-108-10-150-1-85-11-00-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.23 0.18 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 7 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-8 REACTIONS.All bearings 15-4-6. (lb) - Max Horz 2=213(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 10 except 9=-108(LC 6) Max Grav All reactions 250 lb or less at joint(s) 7, 2 except 9=488(LC 10), 10=343(LC 1), 8=496(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-9=-262/156 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 10 except (jt=lb) 9=108. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB03 Truss Type GABLE Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525875 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-DMg2IGWz5OGqD5yrmIToqgjApI7qMN32N1cNhszX3gs Scale = 1:53.5 1 2 3 4 5 6 7 13 12 11 10 9 81415 4x6 2x4 2x4 3x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 19-10-4 19-10-4 12-0-10 12-0-10 19-10-4 7-9-11 0-4-108-10-150-1-83-0-110-1-89.00 12 Plate Offsets (X,Y)-- [11:0-1-4,0-0-0], [12:0-3-0,0-1-4], [12:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.15 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 8 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-10 REACTIONS.All bearings 19-2-2. (lb) - Max Horz 2=237(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 8, 2, 10, 13 except 11=-106(LC 6), 9=-113(LC 7) Max Grav All reactions 250 lb or less at joint(s) 8, 2 except 10=442(LC 1), 11=487(LC 10), 13=343(LC 1), 9=512(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-250/221 WEBS 4-11=-261/155, 6-9=-272/161 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2, 10, 13 except (jt=lb) 11=106, 9=113. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB04 Truss Type GABLE Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525876 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:44 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-hYEQVcWbshOhrEX1K??1MtGMuiT25qMBchLwEJzX3gr Scale = 1:53.8 1 2 3 4 5 6 7 8 15 14 13 12 11 10 91617 4x6 2x4 2x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-1-8 22-1-8 12-0-10 12-0-10 22-1-8 10-0-15 0-4-108-10-150-1-81-4-40-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.15 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 9 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 76 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.All bearings 21-5-6. (lb) - Max Horz 2=217(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 15 except 13=-106(LC 6), 11=-106(LC 7), 10=-104(LC 7) Max Grav All reactions 250 lb or less at joint(s) 9, 2 except 12=438(LC 1), 13=495(LC 10), 15=343(LC 1), 11=505(LC 11), 10=286(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-13=-261/155, 6-11=-268/157 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15 except (jt=lb) 13=106, 11=106, 10=104. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB05 Truss Type Piggyback Qty 5 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525877 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:45 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-9looiyXDd?WYTO6DtiWGv5oWg5mgqJxLqL5TmlzX3gq Scale = 1:34.5 1 2 3 45 6 4x6 3x8 3x8 2x4 11-4-9 11-4-9 5-8-4 5-8-4 11-4-9 5-8-4 0-5-35-6-120-1-80-5-30-1-812.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-1-2], [4:0-8-0,0-1-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.24 0.32 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.01 0.02 0.00 -0.01 (loc) 5 5 4 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=258/10-3-2, 4=258/10-3-2, 6=344/10-3-2 Max Horz 2=-122(LC 4) Max Uplift 2=-29(LC 7), 4=-37(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB06 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525878 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:46 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-exMAwIYrOJeP4YhQRQ1VSILiMV9nZnZU3?q1IBzX3gp Scale = 1:14.2 1 2 3 4 5 6 8 7 4x6 4x6 2x4 2x4 2x4 2x4 7-1-5 7-1-5 7-1-5 7-1-5 0-5-101-2-101-4-80-1-80-5-100-1-81-2-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-10,0-1-0], [3:0-3-2,0-2-0], [4:0-3-2,0-2-0], [5:0-2-10,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.14 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 -0.00 0.00 0.00 (loc) 5 5 5 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-1-2. (lb) - Max Horz 2=-29(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 2, 5, 8, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB07 Truss Type Piggyback Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525879 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-67wY7eZT9cmFiiGc?7Yk_WuvKvXTIEzdIfaardzX3go Scale = 1:17.9 1 2 3 4 5 6 8 7 4x6 4x6 2x4 2x4 2x4 2x4 7-1-5 7-1-5 7-1-5 7-1-5 0-5-102-8-102-10-80-1-80-5-100-1-82-8-1014.00 12 Plate Offsets (X,Y)-- [2:0-4-0,0-0-14], [3:0-3-2,0-2-0], [4:0-3-2,0-2-0], [5:0-4-0,0-0-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.04 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 5 6 5 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-1-2. (lb) - Max Horz 2=-66(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 7, 8 Max Grav All reactions 250 lb or less at joint(s) 2, 5, 7, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 7, 8. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PB08 Truss Type Piggyback Qty 4 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525880 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:47 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-67wY7eZT9cmFiiGc?7Yk_WuufvWLIEodIfaardzX3go Scale = 1:26.6 1 2 3 4 5 6 4x6 3x4 3x4 2x4 7-1-5 7-1-5 3-6-11 3-6-11 7-1-5 3-6-11 0-5-104-0-40-1-80-5-100-1-814.00 12 Plate Offsets (X,Y)-- [2:0-4-0,0-0-10], [3:Edge,0-1-14], [4:0-4-0,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.08 0.11 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 5 5 4 5 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 22 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=154/6-1-2, 4=154/6-1-2, 6=192/6-1-2 Max Horz 2=95(LC 5) Max Uplift 2=-19(LC 7), 4=-16(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PBE01 Truss Type GABLE Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525881 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:49 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2W2JYKakhE0zx0P?6YaC3xzFcjC2m7?wly3hvWzX3gm Scale = 1:60.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 24-1-3 24-1-3 12-0-10 12-0-10 24-1-3 12-0-10 0-4-108-10-150-1-80-4-100-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.05 0.04 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.01 -0.00 (loc) 18 19 18 18 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud *Except* 10-27: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-27 REACTIONS.All bearings 22-8-14. (lb) - Max Horz 2=-200(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 27, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 28, 29, 30, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PBE02 Truss Type GABLE Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525882 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:50 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-WibhmfbMSX8qZ9_BgG6Rc8WPk6YBVaF4_coERyzX3gl Scale = 1:57.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 4x6 2x4 3x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-10-0 21-10-0 12-0-10 12-0-10 21-10-0 9-9-7 0-4-108-10-150-1-81-6-140-1-89.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.09 0.04 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.00 0.00 0.00 -0.00 (loc) 1 1 19 1 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 10-26: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-26 REACTIONS.All bearings 21-1-14. (lb) - Max Horz 2=220(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 2, 26, 27, 28, 29, 30, 32, 33, 34, 25, 24, 23, 22, 21, 20 Max Grav All reactions 250 lb or less at joint(s) 19, 2, 26, 27, 28, 29, 30, 32, 33, 34, 25, 24, 23, 22, 21, 20 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 26, 27, 28, 29, 30, 32, 33, 34, 25, 24, 23, 22, 21, 20. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss PBE03 Truss Type GABLE Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525883 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:51 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-_u93z?c_DrGhBJZNEzdg9M2aUWujE2TDDGYo_PzX3gk Scale = 1:35.7 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-4-9 11-4-9 5-8-4 5-8-4 11-4-9 5-8-4 0-5-35-6-120-1-80-5-30-1-812.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-1-8], [10:0-2-6,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.03 0.02 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in 0.00 0.00 0.00 0.00 (loc) 10 10 10 10 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-3-2. (lb) - Max Horz 2=-122(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 16, 17, 18, 14, 13, 12. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T01 Truss Type PIGGYBACK BASE Qty 4 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525884 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:53 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-wHHqOhdElSXPQdjmLOf8En8kMKLHimhWga1v2HzX3gi Scale = 1:93.9 1 2 3 4 5 6 7 8 9 10 11 12 13 23 22 21 20 19 18 17 16 15 142829303132333534 4x6 6x8 4x6 6x8 4x6 10x10 4x6 3x8 4x6 2x4 3x6 4x8 2x4 4x6 4x6 3x6 4x6 3x8 3x6 8x8 3x12 3x8 MT18HS 7-6-0 7-6-0 14-9-8 7-3-8 22-10-7 8-1-0 30-9-11 7-11-4 38-10-11 8-1-0 46-2-3 7-3-8 52-2-8 6-0-5 -1-2-8 1-2-8 7-6-0 7-6-0 14-9-8 7-3-8 22-10-7 8-1-0 30-9-11 7-11-4 38-10-11 8-1-0 46-2-3 7-3-8 52-2-8 6-0-5 0-10-1412-0-02-0-212-0-09.00 12 Plate Offsets (X,Y)-- [2:1-0-4,0-2-0], [6:0-5-4,0-3-0], [10:0-5-4,0-3-0], [15:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.77 0.98 0.77 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.31 -0.56 0.19 0.10 (loc) 20-22 20-22 14 20 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 299 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 19-21: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-23,4-22,12-16,12-15,13-15: 2x3 SPF No.2, 13-14: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-0-13 max.): 6-10. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-22, 6-20, 7-20, 9-20, 9-18, 10-18, 12-16 REACTIONS.(lb/size)2=2666/0-3-8, 14=2541/Mechanical Max Horz 2=270(LC 5) Max Uplift 2=-79(LC 6), 14=-31(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3680/273, 4-6=-3146/342, 6-7=-2950/367, 7-9=-2950/367, 9-10=-2913/364, 10-12=-2969/328, 12-13=-2933/231, 13-14=-2484/193 BOT CHORD 2-23=-258/2799, 22-23=-258/2799, 20-22=-212/2449, 18-20=-188/2913, 16-18=-59/2269, 15-16=-114/2269 WEBS 4-23=0/268, 4-22=-469/182, 6-22=-20/639, 6-20=-230/992, 7-20=-494/211, 9-18=-622/283, 10-18=-227/1223, 10-16=-12/342, 12-15=-415/117, 13-15=-110/2253 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T02 Truss Type Piggyback Base Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525885 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:54 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-PTrCb1esWmfG2nIyv5ANm_gu3kkQRDgfvEmSajzX3gh Scale: 1/8"=1' 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 1429303132333435 4x6 6x8 4x6 6x8 6x6 6x6 10x10 4x6 3x6 4x6 2x4 3x6 4x8 2x4 4x6 4x6 3x6 3x6 4x6 5x8 3x6 3x8 MT18HS3x8 MT18HS 7-6-0 7-6-0 14-9-8 7-3-8 22-10-7 8-1-0 30-9-11 7-11-4 38-10-11 8-1-0 40-6-5 1-7-10 46-2-3 5-7-14 52-2-8 6-0-5 -1-2-8 1-2-8 7-6-0 7-6-0 14-9-8 7-3-8 22-10-7 8-1-0 30-9-11 7-11-4 38-10-11 8-1-0 40-6-5 1-7-10 46-2-3 5-7-14 52-2-8 6-0-5 0-10-1410-9-412-0-04-10-012-0-09.00 12 6.10 12 Plate Offsets (X,Y)-- [2:1-0-4,0-2-0], [6:0-5-4,0-3-0], [10:0-5-4,0-3-0], [13:Edge,0-2-4], [15:0-2-8,0-2-8], [16:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 0.84 0.79 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.29 -0.53 0.18 0.10 (loc) 21-23 21-23 14 21 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 321 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-24,4-23,11-16,12-16,12-15,13-15: 2x3 SPF No.2 13-14: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-0-13 max.): 6-10. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-23, 6-21, 7-21, 9-21, 9-19, 10-19, 11-17, 11-16, 12-15, 13-14 REACTIONS.(lb/size)2=2666/0-3-8, 14=2537/Mechanical Max Horz 2=230(LC 6) Max Uplift 2=-75(LC 6), 14=-46(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3680/281, 4-6=-3143/351, 6-7=-2949/378, 7-9=-2949/378, 9-10=-2912/379, 10-11=-2790/386, 11-12=-2634/326, 12-13=-2139/217, 13-14=-2488/245 BOT CHORD 2-24=-212/2798, 23-24=-212/2798, 21-23=-168/2447, 19-21=-178/2912, 17-19=-99/2261, 16-17=-119/2271, 15-16=-136/1846 WEBS 4-24=0/272, 4-23=-472/182, 6-23=-21/634, 6-21=-229/994, 7-21=-493/211, 9-19=-616/250, 10-19=-185/1225, 10-17=-76/385, 11-16=-618/73, 12-16=-81/754, 12-15=-1187/183, 13-15=-169/2301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T03 Truss Type PIGGYBACK BASE Qty 5 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525886 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:55 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-tgPapNfVG4n7fxt8TphcJCD1N71lAldp7uW?7AzX3gg Scale = 1:74.5 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 20 21 22 23 24 3x4 6x8 3x4 6x16 3x6 8x10 4x6 3x4 3x6 2x4 3x6 2x4 5x12 3x4 7-6-0 7-6-0 14-9-8 7-3-8 22-9-12 8-0-4 30-10-0 8-0-4 -1-2-8 1-2-8 7-6-0 7-6-0 14-9-8 7-3-8 22-9-12 8-0-4 30-10-0 8-0-4 0-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [6:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-AS 1.00 0.91 0.49 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.36 0.41 0.04 (loc) 11-13 11-13 20 14-18 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 164 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-14,4-13: 2x3 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x6 SPF No.2 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins: 6-9. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-13, 6-11, 7-11, 9-11 REACTIONS.(lb/size)2=1596/0-3-8, 20=1566/0-3-0 Max Horz 2=383(LC 6) Max Uplift 2=-36(LC 6), 20=-95(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1981/65, 4-6=-1445/126, 6-7=-829/100, 7-9=-829/100 BOT CHORD 2-14=-277/1488, 13-14=-277/1488, 11-13=-153/1059 WEBS 4-14=0/301, 4-13=-570/188, 6-13=-26/690, 6-11=-406/115, 7-11=-558/227, 9-11=-175/1434, 9-20=-1593/174 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 20. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T04 Truss Type Common Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525887 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:56 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-Lszy0jg71Nv_H4SL1WCrsPlLQXUYvEryMYFZfczX3gf Scale = 1:65.8 1 2 3 4 5 6 9 8 7 4x6 3x4 3x8 3x4 3x4 3x4 3x6 3x6 7-11-8 7-11-8 15-11-0 7-11-8 -1-2-8 1-2-8 3-0-0 3-0-0 7-11-8 4-11-8 12-11-0 4-11-8 15-11-0 3-0-0 1-5-910-9-01-5-914.00 12 Plate Offsets (X,Y)-- [4:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.40 0.49 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.19 0.01 0.01 (loc) 7-8 8-9 7 8 l/defl >999 >967 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-8: 2x4 SPF No.2, 2-9,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=710/0-3-8, 7=621/0-3-8 Max Horz 9=288(LC 5) Max Uplift 9=-46(LC 6), 7=-31(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-507/166, 4-5=-508/167 BOT CHORD 8-9=-154/315, 7-8=-4/325 WEBS 4-8=-128/375, 3-9=-544/40, 5-7=-525/69 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T05 Truss Type PIGGYBACK BASE Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525888 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:57 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-p2XKE3hloh1rvE0XaEk4OdIPqxnuebd6bC?6B2zX3ge Scale = 1:72.6 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 3x4 4x6 3x4 6x16 3x6 3x8 3x8 3x4 3x4 4x6 4x8 3x4 10-9-8 10-9-8 18-8-0 7-10-8 26-10-0 8-2-0 4-6-0 4-6-0 10-9-8 6-3-8 18-8-0 7-10-8 26-10-0 8-2-0 3-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.87 0.68 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.41 -0.87 0.41 0.03 (loc) 10-11 10-11 13 8-10 l/defl >781 >366 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 153 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 9-11: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-10,2-11: 2x3 SPF No.2, 1-11: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-8 oc purlins, except end verticals, and 2-0-0 oc purlins (4-4-1 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10, 4-8, 6-8, 2-11 REACTIONS.(lb/size)11=1323/0-3-8, 13=1382/0-3-0 Max Horz 11=247(LC 6) Max Uplift 13=-102(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1082/109, 3-4=-771/134, 4-6=-713/98 BOT CHORD 10-11=-244/673, 8-10=-98/713 WEBS 4-8=-660/235, 6-8=-170/1214, 2-11=-1171/41, 6-13=-1406/165 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 13=102. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T06 Truss Type PIGGYBACK BASE Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525889 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:13:58 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-HF4jROhNZ?9iXObj8xFJxqraRL6hN0WFqskfjVzX3gd Scale = 1:70.7 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 3x4 4x6 3x4 6x16 3x6 3x4 3x8 3x4 2x4 3x8 2x4 6x8 4x8 3x4 10-9-8 10-9-8 17-4-5 6-6-13 23-9-7 6-5-1 30-7-12 6-10-5 4-6-0 4-6-0 10-9-8 6-3-8 17-4-5 6-6-13 23-9-7 6-5-1 30-7-12 6-10-5 3-10-1412-0-010-1-1212-0-09.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.88 0.71 0.86 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.42 -0.88 0.42 0.04 (loc) 12-13 12-13 15 9-10 l/defl >876 >414 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 188 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 11-13: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-12,2-13: 2x3 SPF No.2, 1-13: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-13 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-5 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 4-9, 6-9, 7-9, 2-13 REACTIONS.(lb/size)13=1537/0-3-8, 15=1573/0-3-0 Max Horz 13=247(LC 6) Max Uplift 15=-113(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1326/134, 3-4=-968/154, 4-6=-741/85, 6-7=-741/85 BOT CHORD 12-13=-258/805, 10-12=-139/1044, 9-10=-139/1044 WEBS 3-12=0/356, 4-10=0/301, 4-9=-630/112, 6-9=-457/168, 7-9=-168/1454, 2-13=-1420/67, 7-15=-1597/171 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 15=113. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T07 Truss Type PIGGYBACK BASE Qty 7 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525890 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:00 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-DdCTs4jd5cPPmil6GMHn0Fww?8nYrwuYHADmoNzX3gb Scale = 1:75.1 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 91718192021 3x4 5x6 3x6 5x8 4x6 3x6 3x8 3x6 2x4 3x8 2x4 6x8 5x8 4x8 3x4 3x6 10-9-8 10-9-8 18-10-7 8-1-0 26-9-11 7-11-4 34-10-11 8-1-0 37-3-0 2-4-5 4-6-0 4-6-0 10-9-8 6-3-8 18-10-7 8-1-0 26-9-11 7-11-4 34-10-11 8-1-0 37-3-0 2-4-5 3-10-1412-0-010-2-1212-0-09.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-2], [7:0-6-0,0-2-0], [8:Edge,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.88 0.81 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.41 -0.88 0.07 0.06 (loc) 15-16 15-16 9 13 l/defl >999 >506 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 229 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 14-16: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 2-15: 2x3 SPF No.2, 1-16,2-16: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-1-3 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-15, 4-11, 6-11, 7-11, 7-10, 2-16 2 Rows at 1/3 pts 8-9 REACTIONS.(lb/size)16=1883/0-3-8, 9=1909/0-3-8 Max Horz 16=211(LC 6) Max Uplift 16=-46(LC 5), 9=-156(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1723/190, 3-4=-1291/200, 4-6=-1270/165, 6-7=-1271/165, 7-8=-478/60, 8-9=-1977/154 BOT CHORD 15-16=-238/1018, 13-15=-202/1590, 11-13=-202/1590, 10-11=-35/374 WEBS 2-15=-80/462, 3-15=0/568, 4-15=-616/177, 4-13=0/413, 4-11=-573/84, 6-11=-508/206, 7-11=-211/1580, 7-10=-1349/243, 2-16=-1823/123, 8-10=-163/1719 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 9=156. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T08 Truss Type PIGGYBACK BASE Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525891 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:02 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-A0KDHmkudDf7??vUNnJF5g?GOyRYJoCrkUitsGzX3gZ Scale = 1:74.0 1 2 3 4 5 6 7 14 13 12 11 10 9 81516171819 3x4 4x6 3x4 5x6 3x4 3x8 MT18HS 3x8 3x6 2x4 3x8 2x4 6x8 4x8 3x6 10-9-8 10-9-8 18-2-9 7-5-1 25-5-15 7-3-5 32-11-0 7-5-1 4-6-0 4-6-0 10-9-8 6-3-8 18-2-9 7-5-1 25-5-15 7-3-5 32-11-0 7-5-1 3-10-1412-0-09.00 12 Plate Offsets (X,Y)-- [3:0-3-12,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.88 0.84 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.41 -0.88 0.05 0.03 (loc) 13-14 13-14 8 11 l/defl >949 >447 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 193 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 10-12: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-8: 2x4 SPF 2100F 1.8E, 2-13,2-14: 2x3 SPF No.2 1-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-3 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-14 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8, 4-13, 4-9, 6-9, 7-9, 2-14 REACTIONS.(lb/size)8=1730/0-3-8, 14=1655/Mechanical Max Horz 14=247(LC 6) Max Uplift 8=-129(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1462/148, 3-4=-1078/166, 4-6=-861/94, 6-7=-861/94, 7-8=-1553/210 BOT CHORD 13-14=-265/878, 11-13=-154/1224, 9-11=-154/1224 WEBS 2-13=-67/283, 3-13=0/417, 4-13=-276/147, 4-11=0/360, 4-9=-687/113, 6-9=-468/189, 7-9=-176/1608, 2-14=-1557/81 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=129. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T09 Truss Type Common Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525892 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:03 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-eCucU6lWOXn_d9UhxUqUetYTeMnq2IT_z8SQPizX3gY Scale = 1:66.6 1 2 3 4 5 6 7 11 10 9 812131415 4x6 3x4 3x8 3x4 3x4 3x4 4x8 4x8 3x4 9-9-4 9-9-4 19-6-8 9-9-4 -1-2-8 1-2-8 4-11-14 4-11-14 9-9-4 4-9-6 14-6-10 4-9-6 19-6-8 4-11-14 20-9-0 1-2-8 1-2-1411-0-21-2-1412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.72 0.84 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.19 -0.45 0.02 0.23 (loc) 8-9 8-9 8 8-9 l/defl >999 >513 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 95 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-9: 2x4 SPF No.2, 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.(lb/size)11=978/0-10-0, 8=978/0-10-0 Max Horz 11=-264(LC 4) Max Uplift 11=-221(LC 6), 8=-221(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-373/342, 3-4=-736/449, 4-5=-736/449, 5-6=-373/342, 2-11=-416/310, 6-8=-416/310 BOT CHORD 9-11=-186/544, 8-9=-106/544 WEBS 4-9=-532/612, 3-11=-553/61, 5-8=-553/61 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=221, 8=221. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T10 Truss Type Piggyback Base Qty 2 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525893 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:04 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-6PS_iSm89rvrFJ3tVCMjA55h7l6inn37CoB_x8zX3gX Scale = 1:74.2 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12192021222324 3x6 6x6 4x6 3x4 3x4 3x4 3x8 2x4 3x4 3x4 3x8 3x4 3x6 4x8 3x4 3x8 6-9-0 6-9-0 13-9-4 7-0-4 22-1-10 8-4-6 32-10-12 10-9-2 -1-2-8 1-2-8 5-0-0 5-0-0 10-9-2 5-9-2 16-5-6 5-8-4 22-1-10 5-8-4 27-6-0 5-4-6 32-10-12 5-4-12 34-1-4 1-2-8 1-2-1412-0-01-2-1412-0-012.00 12 Plate Offsets (X,Y)-- [5:0-4-4,0-1-12], [7:0-4-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.55 0.92 0.60 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.36 -0.85 0.01 0.33 (loc) 12-13 12-13 12 12-13 l/defl >623 >266 n/a >684 L/d 360 240 n/a 240 PLATES MT20 Weight: 182 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-17,8-13,2-17,8-12: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 8-7-7 oc bracing: 13-15. WEBS 1 Row at midpt 5-15, 6-15, 6-13, 8-13 REACTIONS.(lb/size)18=589/0-3-8, 15=1805/0-3-8, 12=936/0-10-0 Max Horz 18=287(LC 5) Max Uplift 18=-51(LC 6), 15=-237(LC 5), 12=-242(LC 7) Max Grav 18=610(LC 10), 15=1805(LC 1), 12=954(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-532/89, 3-5=-456/239, 6-7=-368/327, 7-8=-646/381, 8-10=-482/348, 2-18=-561/116, 10-12=-496/314 BOT CHORD 17-18=-267/313, 12-13=-59/506 WEBS 3-17=-278/238, 5-17=-153/478, 5-15=-574/110, 6-15=-908/301, 6-13=-204/558, 2-17=-19/258, 8-12=-374/34 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18 except (jt=lb) 15=237, 12=242. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T11 Truss Type Piggyback Base Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525894 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:05 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-ab?Mvonmw81isTe32vtyjIdst9SxWEBHRSxXTbzX3gW Scale = 1:73.4 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10171819202122 3x6 6x6 4x6 3x4 3x4 3x4 3x8 2x4 3x4 3x4 3x8 3x4 3x6 4x8 3x8 6-9-0 6-9-0 13-9-4 7-0-4 22-1-10 8-4-6 32-10-12 10-9-2 -1-2-8 1-2-8 5-0-0 5-0-0 10-9-2 5-9-2 16-5-6 5-8-4 22-1-10 5-8-4 27-6-0 5-4-6 32-10-12 5-4-12 1-2-1412-0-01-2-1412-0-012.00 12 Plate Offsets (X,Y)-- [5:0-4-4,0-1-12], [7:0-4-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.55 0.92 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.36 -0.85 0.01 0.33 (loc) 10-11 10-11 10 10-11 l/defl >623 >266 n/a >686 L/d 360 240 n/a 240 PLATES MT20 Weight: 180 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-15,8-11,2-15,8-10: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 8-7-7 oc bracing: 11-13. WEBS 1 Row at midpt 5-13, 6-13, 6-11, 8-11 REACTIONS.(lb/size)16=587/0-3-8, 13=1812/0-3-8, 10=850/0-10-0 Max Horz 16=303(LC 5) Max Uplift 16=-43(LC 6), 13=-242(LC 5), 10=-187(LC 7) Max Grav 16=608(LC 10), 13=1812(LC 1), 10=868(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-530/68, 3-5=-454/219, 6-7=-369/316, 7-8=-649/366, 8-9=-472/302, 2-16=-560/99, 9-10=-401/232 BOT CHORD 15-16=-283/293, 10-11=-112/514 WEBS 3-15=-278/239, 5-15=-154/478, 5-13=-576/113, 6-13=-912/314, 6-11=-217/563, 2-15=-14/257, 8-10=-386/29 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 13=242, 10=187. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T12 Truss Type Piggyback Base Qty 2 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525895 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2nZk68oOhS9ZUdCGcdOBFWAw8ZpeFflQf6g501zX3gV Scale = 1:72.0 1 2 3 4 5 6 7 14 13 12 11 10 9 8151617181920 3x6 6x6 4x6 3x4 3x4 3x4 3x8 2x4 3x4 3x4 3x8 3x4 4x8 3x6 6-9-0 6-9-0 13-9-4 7-0-4 22-1-10 8-4-6 32-7-8 10-5-14 5-0-0 5-0-0 10-9-2 5-9-2 16-5-6 5-8-4 22-1-10 5-8-4 27-6-0 5-4-6 32-7-8 5-1-8 1-2-1412-0-01-6-212-0-012.00 12 Plate Offsets (X,Y)-- [3:0-4-4,0-1-12], [5:0-4-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.96 0.89 0.72 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.33 -0.78 0.01 0.30 (loc) 8-9 8-9 8 8-9 l/defl >684 >289 n/a >738 L/d 360 240 n/a 240 PLATES MT20 Weight: 178 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-13,6-9,1-13,6-8: 2x3 SPF No.2, 1-14,7-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 9-6-8 oc bracing. WEBS 1 Row at midpt 3-11, 4-11, 4-9, 6-9 REACTIONS.(lb/size)14=498/0-3-8, 11=1799/0-3-8, 8=831/0-3-8 Max Horz 14=267(LC 5) Max Uplift 11=-236(LC 5), 8=-178(LC 7) Max Grav 14=519(LC 10), 11=1799(LC 1), 8=849(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-527/51, 2-3=-457/206, 4-5=-355/304, 5-6=-628/349, 6-7=-354/228, 1-14=-470/41, 7-8=-313/178 BOT CHORD 13-14=-252/270, 8-9=-126/482 WEBS 2-13=-289/247, 3-13=-159/488, 3-11=-581/116, 4-11=-897/317, 4-9=-220/546, 1-13=-9/251, 6-8=-475/65 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=236, 8=178. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T13 Truss Type ROOF SPECIAL Qty 3 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525896 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:06 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2nZk68oOhS9ZUdCGcdOBFWA4aZzdFgJQf6g501zX3gV Scale = 1:70.2 1 2 3 4 8 7 6 5 910 11 3x6 4x6 6x16 2x4 2x4 3x4 3x4 3x12 3x4 5-11-6 5-11-6 11-8-3 5-8-14 14-0-0 2-3-13 5-11-6 5-11-6 11-8-3 5-8-14 14-0-0 2-3-13 4-10-010-9-412-6-210-1-1212-6-26.10 12 9.00 12 Plate Offsets (X,Y)-- [4:0-6-14,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.36 0.25 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.05 -0.09 0.11 0.02 (loc) 6-7 6-7 10 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 98 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-7,2-6,1-7: 2x3 SPF No.2, 1-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-6, 3-6 REACTIONS.(lb/size)8=602/Mechanical, 10=583/0-3-0 Max Horz 8=296(LC 6) Max Uplift 10=-191(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-432/0, 1-8=-558/0 BOT CHORD 7-8=-323/13, 6-7=-189/327 WEBS 2-6=-340/234, 3-6=-310/154, 4-6=-282/705, 1-7=0/400, 4-10=-589/245 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Refer to girder(s) for truss to truss connections. 5) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=191. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T14 Truss Type Common Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525897 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:07 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-Wz76KTo0SmHQ6nnSAKvQojjDlzF7_AIaumQeYTzX3gU Scale = 1:75.5 1 2 3 4 5 6 9 8 710111213 3x4 4x6 3x8 3x4 3x4 3x6 3x4 3x6 7-11-8 7-11-8 15-11-0 7-11-8 2-6-0 2-6-0 7-11-8 5-5-8 13-5-0 5-5-8 15-11-0 2-6-0 17-1-8 1-2-8 3-0-1112-4-23-0-1114.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.39 0.49 0.51 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.20 0.01 0.01 (loc) 7-8 7-8 7 7-8 l/defl >999 >920 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-8: 2x4 SPF No.2, 1-9,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=712/0-3-8, 7=800/0-3-8 Max Horz 9=-343(LC 4) Max Uplift 9=-46(LC 7), 7=-43(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-516/197, 3-4=-515/196 BOT CHORD 8-9=-198/322 WEBS 3-8=-162/305, 2-9=-597/72, 4-7=-592/23 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T15 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525898 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:08 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-_AhUXppeD3PHjwMek2QfLxFOuNYojWvj7Q9B4wzX3gT Scale = 1:75.5 1 2 3 4 5 6 7 8 13 12 11 10 91415 6x6 6x6 4x6 3x4 3x6 3x8 3x4 2x4 3x6 3x6 3x4 7-9-2 7-9-2 13-7-8 5-10-6 21-7-0 7-11-8 -1-2-8 1-2-8 2-1-2 2-1-2 7-9-2 5-8-0 13-7-8 5-10-6 19-1-0 5-5-8 21-7-0 2-6-0 22-9-8 1-2-8 3-0-115-4-212-4-23-0-115-4-214.00 12 Plate Offsets (X,Y)-- [3:0-3-15,0-3-0], [4:0-3-0,Edge], [5:Edge,0-1-14], [12:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.43 0.59 0.93 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.11 -0.29 0.02 0.02 (loc) 9-10 9-10 9 12 l/defl >999 >879 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 113 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-10: 2x4 SPF No.2, 2-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-4 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)13=945/0-3-8, 9=1012/0-3-8 Max Horz 13=-327(LC 4) Max Uplift 13=-69(LC 6), 9=-53(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-852/157, 4-5=-723/191, 5-6=-715/203 BOT CHORD 12-13=-210/290, 10-12=-51/859, 9-10=0/329 WEBS 3-12=-43/763, 4-12=-394/112, 4-10=-631/196, 5-10=-165/554, 3-13=-769/112, 6-9=-788/36 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 4 = 4% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T16 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525899 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:10 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-xYpFyVrvkgg?zEW1rSS7QMLlJA9nBR90akeI9ozX3gR Scale = 1:75.5 1 2 3 4 5 6 7 8 13 12 11 10 914151617 4x6 5x6 4x6 2x4 3x4 3x8 3x8 3x4 3x6 3x6 3x4 3-4-9 3-4-9 13-7-8 10-2-15 21-7-0 7-11-8 -1-2-8 1-2-8 3-4-9 3-4-9 9-0-9 5-8-0 13-7-8 4-6-15 19-1-0 5-5-8 21-7-0 2-6-0 22-9-8 1-2-8 3-0-116-10-212-4-23-0-116-10-214.00 12 Plate Offsets (X,Y)-- [3:0-3-2,0-2-0], [4:0-3-0,0-3-4], [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.94 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.31 -0.62 0.02 0.02 (loc) 10-12 10-12 9 10 l/defl >823 >411 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 115 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-10: 2x4 SPF No.2, 2-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-12 REACTIONS.(lb/size)13=1042/0-3-8, 9=1079/0-3-8 Max Horz 13=326(LC 5) Max Uplift 13=-69(LC 6), 9=-53(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-769/141, 3-4=-465/129, 4-5=-779/209, 5-6=-808/200, 2-13=-1104/101 BOT CHORD 12-13=-303/308, 10-12=-70/760, 9-10=0/363 WEBS 3-12=-24/263, 4-12=-460/82, 4-10=-564/221, 5-10=-192/728, 2-12=-22/623, 6-9=-915/30 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T17 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525900 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:11 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-PlNdArrXV_osaO5DPA_MyZtw7aWMwvz9pNOrhEzX3gQ Scale = 1:75.5 1 2 3 4 5 6 7 8 13 12 11 10 9141516 4x6 6x6 4x6 2x4 3x6 3x8 4x8 3x4 4x6 3x6 3x4 4-8-0 4-8-0 13-7-8 8-11-8 21-7-0 7-11-8 -1-2-8 1-2-8 4-8-0 4-8-0 10-4-0 5-8-0 13-7-8 3-3-8 19-1-0 5-5-8 21-7-0 2-6-0 22-9-8 1-2-8 3-0-118-4-212-4-23-0-118-4-214.00 12 Plate Offsets (X,Y)-- [3:0-3-2,0-2-0], [5:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.86 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.23 -0.41 0.02 0.02 (loc) 10-12 10-12 9 10-12 l/defl >999 >624 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 118 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-10: 2x4 SPF No.2, 2-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 4-10 REACTIONS.(lb/size)13=1041/0-3-8, 9=1091/0-3-8 Max Horz 13=326(LC 5) Max Uplift 13=-69(LC 6), 9=-53(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-818/153, 3-4=-472/155, 4-5=-754/233, 5-6=-816/203, 2-13=-1043/120 BOT CHORD 12-13=-308/317, 10-12=-61/651, 9-10=0/367 WEBS 4-12=-318/98, 4-10=-552/224, 5-10=-226/776, 2-12=-41/544, 6-9=-921/38 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T18 Truss Type Roof Special Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525901 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:12 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-txx?NBs9GIwiCYgPztVbVnQ3m_wGfMFJ217PDhzX3gP Scale = 1:78.5 1 2 3 4 5 6 7 8 13 12 11 10 914151617 6x6 6x6 4x6 2x4 3x4 3x8 3x8 3x4 5x8 3x6 3x4 5-11-7 5-11-7 13-7-8 7-8-1 21-7-0 7-11-8 -1-2-8 1-2-8 5-11-7 5-11-7 11-7-7 5-8-0 13-7-8 2-0-1 19-1-0 5-5-8 21-7-0 2-6-0 22-9-8 1-2-8 3-0-119-10-212-4-23-0-119-10-214.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.51 0.62 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.16 -0.26 0.01 0.02 (loc) 10-12 10-12 9 10-12 l/defl >999 >980 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 126 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-12,5-10: 2x4 SPF No.2, 2-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-5 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 4-10 REACTIONS.(lb/size)13=1037/0-3-8, 9=1098/0-3-8 Max Horz 13=326(LC 5) Max Uplift 13=-69(LC 6), 9=-53(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-839/163, 3-4=-459/179, 4-5=-720/250, 5-6=-819/206, 2-13=-1006/130 BOT CHORD 12-13=-318/327, 10-12=-50/561, 9-10=0/369 WEBS 4-10=-566/232, 5-10=-249/808, 2-12=-58/477, 6-9=-918/42 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T19 Truss Type Hip Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525902 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 14:06:17 2019 Page 1 ID:CEuqc7_6VX2rPZi213Y_20yigU4-OTc5kYZTYpCIU6ufnp7WrSSIAtAKrs4ASpgllOzX21K Scale: 3/16"=1' 1 2 3 4 5 6 7 8 13 12 11 10 9 6x6 6x6 3x6 3x8 3x4 3x4 3x4 3x4 3x6 3x6 3x4 7-2-14 7-2-14 14-4-2 7-1-5 21-7-0 7-2-14 -1-2-8 1-2-8 2-6-0 2-6-0 7-2-14 4-8-14 14-4-2 7-1-5 19-1-0 4-8-14 21-7-0 2-6-0 22-9-8 1-2-8 3-0-1111-4-211-6-03-0-1111-4-214.00 12 Plate Offsets (X,Y)-- [4:0-3-15,0-3-0], [5:0-3-15,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.53 0.58 0.78 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.15 -0.22 0.02 0.01 (loc) 10-12 10-12 9 12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 128 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-12,5-12,5-10: 2x4 SPF No.2, 2-13,7-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12 REACTIONS.(lb/size)13=1020/0-3-8, 9=1043/0-3-8 Max Horz 13=304(LC 5) Max Uplift 13=-43(LC 6), 9=-43(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-774/206, 4-5=-438/197, 5-6=-799/207 BOT CHORD 12-13=-219/344, 11-12=-62/454, 10-11=-62/454, 9-10=-12/355 WEBS 3-13=-891/0, 6-9=-920/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 13 and 43 lb uplift at joint 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T20 Truss Type PIGGYBACK BASE Qty 6 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525903 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:14 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-pK2motuPovAQRsqo4IX3aCVPWnfp7HHcVLcWIZzX3gN Scale = 1:64.9 1 2 3 4 5 6 11 10 9 8 7121314 2x4 4x6 8x8 2x4 3x4 3x8 3x4 3x4 3x4 3x6 3x6 7-2-13 7-2-13 14-4-3 7-1-5 21-3-0 6-10-13 2-6-0 2-6-0 7-2-13 4-8-13 14-4-3 7-1-5 19-1-0 4-8-13 21-3-0 2-2-0 3-0-1111-6-03-5-611-6-014.00 12 Plate Offsets (X,Y)-- [3:0-3-2,0-2-0], [4:0-2-11,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.49 0.43 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.10 -0.19 0.02 0.01 (loc) 8-10 10-11 7 8 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 123 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-10,4-10,4-8: 2x4 SPF No.2, 1-11,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.(lb/size)11=989/0-3-8, 7=950/Mechanical Max Horz 11=255(LC 5) Max Uplift 11=-5(LC 7), 7=-15(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-787/184, 3-4=-446/182, 4-5=-776/177 BOT CHORD 10-11=-188/360, 8-10=-37/439, 7-8=-33/313 WEBS 2-11=-874/43, 5-7=-915/121 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss T21 Truss Type COMMON Qty 6 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525904 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:15 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-HWc8?Dv1ZDIH3?P_e02I7P2coBsUsqqlk?M3q0zX3gM Scale = 1:54.2 1 2 3 4 5 6 7 9 8 4x6 5x6 3x8 3x8 2x4 2x4 5x6 10-11-8 10-11-8 21-11-0 10-11-8 -1-2-8 1-2-8 5-7-0 5-7-0 10-11-8 5-4-8 16-4-0 5-4-8 21-11-0 5-7-0 23-1-8 1-2-8 0-6-08-8-100-6-09.00 12 Plate Offsets (X,Y)-- [2:0-2-2,Edge], [6:0-2-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.33 0.91 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.28 -0.73 0.04 0.03 (loc) 6-8 6-8 6 2-8 l/defl >913 >353 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 78 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=946/0-3-8, 6=946/0-3-8 Max Horz 2=-198(LC 4) Max Uplift 2=-77(LC 6), 6=-77(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1099/125, 3-4=-850/126, 4-5=-850/126, 5-6=-1099/125 BOT CHORD 2-8=-53/811, 6-8=0/811 WEBS 4-8=-43/635, 5-8=-292/173, 3-8=-292/173 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 Wedgewood 39 Gray Oaks Job Reference (optional) I36525905 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:16 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-liAWDYvgKWQ8h9zBCjZXfdaj6bLXb9Svyf5cMSzX3gL Scale = 1:65.8 1 2 3 4 5 10 9 8 7 6111213141516 4x6 4x8 4x6 3x8 3x8 10x10 4x8 10x10 4x8 10x10 4-1-8 4-1-8 7-11-8 3-10-0 11-9-8 3-10-0 15-11-0 4-1-8 4-1-8 4-1-8 7-11-8 3-10-0 11-9-8 3-10-0 15-11-0 4-1-8 1-5-910-9-01-5-914.00 12 Plate Offsets (X,Y)-- [1:0-2-12,0-1-8], [3:Edge,0-2-0], [5:0-2-12,0-1-8], [7:0-3-8,0-5-0], [9:0-3-8,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.61 0.35 0.83 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.13 0.01 0.03 (loc) 8-9 8-9 6 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 331 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-8,1-10,5-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=9116/0-3-8, 6=6478/0-3-8 Max Horz 10=-262(LC 3) Max Uplift 10=-180(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-7750/190, 2-3=-5394/217, 3-4=-5398/218, 4-5=-5943/2, 1-10=-7246/153, 5-6=-5625/0 BOT CHORD 9-10=-268/590, 8-9=-182/4971, 7-8=0/3799 WEBS 3-8=-242/7836, 4-8=-596/54, 4-7=0/702, 2-8=-2728/238, 2-9=-105/3862, 1-9=-60/4570, 5-7=0/3707 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=180. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2518 lb down and 64 lb up at 1-6-4, 2518 lb down and 64 lb up at 3-6-4, 2518 lb down and 64 lb up at 5-6-4, 2518 lb down and 64 lb up at 7-6-4, 2517 lb down and 69 lb up at 9-6-4, 582 lb down at 11-6-4, and 582 lb down at 13-6-4, and 590 lb down at 15-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 Wedgewood 39 Gray Oaks Job Reference (optional) I36525905 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:16 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-liAWDYvgKWQ8h9zBCjZXfdaj6bLXb9Svyf5cMSzX3gL LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 6=-590(B) 7=-582(B) 11=-2518(B) 12=-2518(B) 13=-2518(B) 14=-2518(B) 15=-2517(B) 16=-582(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG02 Truss Type Roof Special Girder Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525906 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:18 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-i5IGeExws8gswT7ZJ8c?l2g4JP2i330BQzajRKzX3gJ Scale = 1:78.5 1 2 3 4 5 6 7 8 9 14 13 12 11 10151617 5x6 4x8 4x6 4x6 4x6 6x8 4x6 3x8 3x6 2x4 4x6 3x4 6-5-11 6-5-11 13-7-8 7-1-13 21-7-0 7-11-8 -1-2-8 1-2-8 0-9-11 0-9-11 6-5-11 5-8-0 8-2-0 1-8-5 13-7-8 5-5-8 19-1-0 5-5-8 21-7-0 2-6-0 22-9-8 1-2-8 3-0-113-10-212-4-23-0-113-10-214.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-12], [6:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.57 0.30 0.89 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.06 -0.16 0.01 0.11 (loc) 11-13 11-13 10 13-14 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 133 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-7 oc purlins, except end verticals, and 2-0-0 oc purlins (4-8-7 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)14=973/0-3-8, 10=941/0-3-8 Max Horz 14=-324(LC 3) Max Uplift 14=-390(LC 5), 10=-121(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1085/404, 4-5=-1743/646, 5-6=-711/250, 6-7=-706/241 BOT CHORD 13-14=-302/324, 11-13=-258/812, 10-11=-14/321 WEBS 3-13=-357/1085, 4-13=-1488/492, 5-11=-611/419, 6-11=-238/569, 3-14=-825/243, 7-10=-823/99, 5-13=-539/1091 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=390, 10=121. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 98 lb down and 130 lb up at 2-0-12, and 98 lb down and 130 lb up at 4-0-12, and 98 lb down and 130 lb up at 5-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-6=-60, 6-8=-60, 8-9=-60, 10-14=-20 Concentrated Loads (lb) Vert: 15=-16 16=-16 17=-16 March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG03 Truss Type Flat Girder Qty 1 Ply 2 Wedgewood 39 Gray Oaks Job Reference (optional) I36525907 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-AHsfrayYdRojYdimtr7EHFCJhoQQoiILfdKHznzX3gI Scale = 1:18.112 4 3 5 6 7 8 2x4 3x4 6x6 4x6 3x4 4-7-0 4-7-0 4-7-0 4-7-0 3-0-111-7-23-0-11LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.27 0.14 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.01 -0.02 0.01 -0.01 (loc) 3-4 3-4 6 3-4 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 46 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=346/0-3-8, 6=340/0-3-0 Max Horz 4=61(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-6=-358/0 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down at 1-4-12, and 184 lb down at 3-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 7=-182(B) 8=-184(B) March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG04 Truss Type Flat Girder Qty 1 Ply 3 Wedgewood 39 Gray Oaks Job Reference (optional) I36525908 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:19 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-AHsfrayYdRojYdimtr7EHFCGIoOvoZoLfdKHznzX3gI Scale = 1:27.0 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 17 3x4 4x10 3x4 4x10 2x4 2x4 3x8 2x4 4x10 4x10 4-0-14 4-0-14 8-0-0 3-11-2 11-11-2 3-11-2 16-0-0 4-0-14 4-0-14 4-0-14 8-0-0 3-11-2 11-11-2 3-11-2 16-0-0 4-0-14 2-1-6Plate Offsets (X,Y)-- [7:0-2-0,0-1-12], [9:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.49 0.30 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.19 0.02 0.05 (loc) 8 8 6 8 l/defl >999 >997 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 294 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 1-9,3-9,3-7,5-7: 2x4 SPF No.2 BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-5, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=4307/0-3-8, 6=4183/0-3-8 Max Horz 10=-48(LC 3) Max Uplift 10=-36(LC 3), 6=-75(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-10=-3866/81, 1-2=-7764/36, 2-3=-7764/36, 3-4=-7529/108, 4-5=-7529/108, 5-6=-3764/112 BOT CHORD 9-10=-35/261, 8-9=-84/10277, 7-8=-84/10277 WEBS 1-9=-31/8143, 2-9=-1308/187, 3-9=-2727/49, 3-8=0/904, 3-7=-2982/0, 4-7=-1325/186, 5-7=-103/7907 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 6. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 273 lb down at 1-9-4, 273 lb down at 3-9-4, 273 lb down at 5-9-4, 273 lb down at 7-9-4, 273 lb down at 9-9-4, 121 lb down at 11-5-4, and 121 lb down at 13-5-4, and 127 lb down at 15-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss TG04 Truss Type Flat Girder Qty 1 Ply 3 Wedgewood 39 Gray Oaks Job Reference (optional) I36525908 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:20 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-eUP13wyAOlwa9nHyRZeTqTlR2Ck8X?2UtH3qVDzX3gH LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-340(F=-280), 6-10=-90(F=-70) Concentrated Loads (lb) Vert: 8=-273(B) 11=-273(B) 12=-273(B) 13=-273(B) 14=-273(B) 15=-121(B) 16=-121(B) 17=-127(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V01 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525909 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:20 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-eUP13wyAOlwa9nHyRZeTqTlVSCm3X6nUtH3qVDzX3gH Scale = 1:54.2 1 2 3 4 7 6 583x4 2x4 2x4 2x4 2x4 2x4 2x4 12-7-11 12-7-11 0-0-49-5-129.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.20 0.18 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 12-7-6. (lb) - Max Horz 1=280(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5 except 6=-101(LC 6), 7=-111(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=521(LC 1), 7=406(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-309/84 WEBS 3-6=-255/155, 2-7=-267/158 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=101, 7=111. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V02 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525910 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-6gzPGGzo932Rnws8_G9iMgIePc4EGboe6xpN1fzX3gG Scale = 1:42.5 1 2 3 5 43x6 2x4 2x4 2x4 2x4 9-6-6 9-6-6 0-0-47-1-129.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.38 0.25 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=158/9-6-0, 4=174/9-6-0, 5=543/9-6-0 Max Horz 1=208(LC 6) Max Uplift 4=-32(LC 6), 5=-137(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-328/202 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=137. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V03 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525911 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:21 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-6gzPGGzo932Rnws8_G9iMgIgWc3eGcue6xpN1fzX3gG Scale = 1:33.3 1 2 3 5 42x4 2x4 2x4 2x4 2x4 7-5-7 7-5-7 0-0-45-7-29.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.25 0.29 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=84/7-5-2, 4=127/7-5-2, 5=342/7-5-2 Max Horz 1=160(LC 6) Max Uplift 4=-39(LC 6), 5=-103(LC 6) Max Grav 1=95(LC 6), 4=127(LC 1), 5=342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-255/166 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=103. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V04 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525912 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-asXnTc_QwMAIP4RKY_gxvuqsS0QE?2NnLbYxa6zX3gF Scale = 1:35.4 1 2 3 4 7 6 53x4 2x4 2x4 2x4 2x4 2x4 2x4 12-2-0 12-2-0 0-0-46-3-26.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.17 0.20 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-3-5. (lb) - Max Horz 1=182(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 5, 6, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=442(LC 1), 7=324(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-259/155 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6, 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V05 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525913 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2259hy?3ggI90E0X6hBAS5NxJQl3kWSwZFIU6YzX3gE Scale = 1:23.2 1 2 3 5 42x4 2x4 2x4 2x4 2x4 7-8-11 7-8-11 0-0-43-11-26.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.48 0.29 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=89/7-8-3, 4=128/7-8-3, 5=343/7-8-3 Max Horz 1=110(LC 6) Max Uplift 4=-24(LC 6), 5=-63(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-255/177 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V06 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525914 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-2259hy?3ggI90E0X6hBAS5N?NQnQkWBwZFIU6YzX3gE Scale = 1:10.8 1 2 3 2x4 2x4 2x4 3-1-10 3-1-10 0-0-41-7-26.10 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.22 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=96/3-1-2, 3=96/3-1-2 Max Horz 1=38(LC 6) Max Uplift 3=-18(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V07 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525915 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-WFfYuH?hR_R?eObjgPjP_JwBCp8GTzD4ov12e_zX3gD Scale = 1:16.2 1 2 3 4 2x4 4x6 2x4 2x4 4-7-0 4-7-0 4-7-4 0-0-3 2-3-10 2-3-10 4-7-4 2-3-10 0-0-42-8-40-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.16 0.10 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=99/4-6-13, 3=99/4-6-13, 4=120/4-6-13 Max Horz 1=-56(LC 4) Max Uplift 1=-19(LC 7), 3=-15(LC 6) Max Grav 1=99(LC 1), 3=99(LC 1), 4=123(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V08 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525916 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-_RDw6d0JCHZsGY9vD6EeXWSO0DVFCQhD1ZnbAQzX3gC Scale = 1:8.7 1 2 3 2x4 3x4 2x4 0-0-3 0-0-3 2-0-6 2-0-3 1-0-3 1-0-3 2-0-6 1-0-3 0-0-41-2-40-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.02 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=56/1-11-15, 3=56/1-11-15 Max Horz 1=20(LC 5) Max Uplift 1=-2(LC 7), 3=-2(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V09 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525917 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-TdnIJz1xzbhjtik6nqlt3k?UsdpIxrRNGDW8jtzX3gB Scale = 1:81.5 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 3x4 4x6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 0-0-4 0-0-4 25-5-5 25-5-1 12-8-10 12-8-10 25-5-5 12-8-10 0-0-412-8-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.34 0.19 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 100 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-3,7-9: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 5-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-12, 4-14, 6-11 REACTIONS.All bearings 25-4-13. (lb) - Max Horz 1=-287(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 9 except 14=-155(LC 6), 15=-179(LC 6), 11=-154(LC 7), 10=-179(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 9 except 12=389(LC 1), 14=493(LC 10), 15=458(LC 1), 11=493(LC 11), 10=458(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-284/160 WEBS 2-15=-275/225, 8-10=-275/225 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9 except (jt=lb) 14=155, 15=179, 11=154, 10=179. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V10 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525918 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-TdnIJz1xzbhjtik6nqlt3k?XNdnExpENGDW8jtzX3gB Scale = 1:72.0 1 2 3 4 5 6 7 13 12 11 10 9 81415 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 22-5-5 22-5-1 11-2-10 11-2-10 22-5-5 11-2-10 0-0-411-2-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.26 0.30 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 22-4-13. (lb) - Max Horz 1=-253(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 11=-165(LC 6), 13=-141(LC 6), 9=-165(LC 7), 8=-141(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=377(LC 1), 11=513(LC 10), 13=343(LC 1), 9=510(LC 11), 8=345(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-263/149 WEBS 3-11=-264/215, 5-9=-264/215 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb) 11=165, 13=141, 9=165, 8=141. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V11 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525919 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-xqLgXJ2ZkvpaVrJILXG6cxYi218XgIHWUtGiFJzX3gA Scale = 1:60.0 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 19-5-5 19-5-1 9-8-10 9-8-10 19-5-5 9-8-10 0-0-49-8-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.18 0.19 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 19-4-13. (lb) - Max Horz 1=-218(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 11=-168(LC 6), 13=-122(LC 6), 9=-168(LC 7), 8=-121(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 13, 8 except 10=382(LC 1), 11=429(LC 10), 9=429(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-267/218, 5-9=-267/218 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb) 11=168, 13=122, 9=168, 8=121. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V12 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525920 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-P0u2kf3BVCxR7?uUvEnL994saRRWPlZgjX?FnlzX3g9 Scale = 1:51.0 1 2 3 4 5 9 87 63x4 4x6 3x4 4x8 2x4 2x4 2x4 2x4 16-5-1 16-5-1 16-5-5 0-0-4 8-2-10 8-2-10 16-5-5 8-2-10 0-0-48-2-100-0-412.00 12 Plate Offsets (X,Y)-- [7:0-0-0,0-1-12], [7:0-4-0,0-1-4], [8:0-1-4,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.19 0.33 0.18 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-4-13. (lb) - Max Horz 1=-183(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-180(LC 6), 6=-180(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=370(LC 1), 9=448(LC 10), 6=448(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-277/225, 4-6=-279/225 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=180, 6=180. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V13 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525921 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-tCSRx?3pGW3Il9ThSyIahMd17qqR8DjpyBloKCzX3g8 Scale = 1:41.8 1 2 3 4 5 8 7 69103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 13-5-5 13-5-1 6-8-10 6-8-10 13-5-5 6-8-10 0-0-46-8-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.21 0.16 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-4-13. (lb) - Max Horz 1=-148(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-151(LC 6), 6=-151(LC 7) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=367(LC 1), 8=337(LC 10), 6=337(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=151, 6=151. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V14 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525922 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-tCSRx?3pGW3Il9ThSyIahMdzJqoM8DxpyBloKCzX3g8 Scale: 3/8"=1' 1 2 3 43x6 4x6 3x6 2x4 0-0-4 0-0-4 10-5-5 10-5-1 5-2-10 5-2-10 10-5-5 5-2-10 0-0-45-2-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.45 0.29 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=217/10-4-13, 3=217/10-4-13, 4=344/10-4-13 Max Horz 1=113(LC 5) Max Uplift 1=-23(LC 7), 3=-23(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V15 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525923 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-LP0p9L4S1qB9MJ2t0fppEaACfE8tthHyBrUMsezX3g7 Scale = 1:24.5 1 2 3 43x4 4x6 3x4 2x4 0-0-4 0-0-4 7-5-4 7-5-1 3-8-10 3-8-10 7-5-4 3-8-10 0-0-43-8-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.22 0.28 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=150/7-4-12, 3=150/7-4-12, 4=240/7-4-12 Max Horz 1=78(LC 5) Max Uplift 1=-18(LC 7), 3=-18(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V16 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525924 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-pbaBMh54o7J0_Td3aNL2mniOleX4c8y6PVEvO4zX3g6 Scale = 1:13.9 1 2 3 4 2x4 4x6 2x4 2x4 0-0-4 0-0-4 4-5-5 4-5-1 2-2-10 2-2-10 4-5-5 2-2-10 0-0-42-2-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.14 0.09 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=89/4-4-13, 3=89/4-4-13, 4=120/4-4-13 Max Horz 1=43(LC 5) Max Uplift 1=-15(LC 7), 3=-15(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V17 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525925 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-pbaBMh54o7J0_Td3aNL2mniNMeUcc536PVEvO4zX3g6 Scale: 1/4"=1' 1 2 3 4 7 6 582x4 4x6 2x4 2x4 2x4 2x4 2x4 7-8-15 7-8-15 6-2-15 6-2-15 7-8-15 1-6-0 0-0-47-3-75-6-714.00 12 Plate Offsets (X,Y)-- [3:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.22 0.31 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 7-8-12. (lb) - Max Horz 1=178(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6 except 7=-190(LC 6) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=344(LC 1), 7=345(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-277/105 WEBS 2-7=-230/283 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6 except (jt=lb) 7=190. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V18 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525926 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-Hn8Za16iZRRtcdCF84sHJ?FVC2oKLZtFe9zTwXzX3g5 Scale = 1:38.7 1 2 3 5 43x6 4x6 2x4 2x4 2x4 6-5-8 6-5-8 4-11-8 4-11-8 6-5-8 1-6-0 0-0-45-9-74-0-714.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-S 0.41 0.41 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=159/6-5-5, 4=-31/6-5-5, 5=355/6-5-5 Max Horz 1=132(LC 6) Max Uplift 4=-60(LC 10), 5=-102(LC 6) Max Grav 1=159(LC 1), 4=38(LC 5), 5=355(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=102. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V19 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525927 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-l_ixnM6KKlZkDmnShoNWsCogYSBk42qPtpj0TzzX3g4 Scale = 1:28.8 1 2 3 5 42x4 4x6 2x4 2x4 2x4 5-2-1 5-2-1 3-8-1 3-8-1 5-2-1 1-6-0 0-0-44-3-72-6-714.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.44 0.20 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=128/5-1-14, 4=41/5-1-14, 5=212/5-1-14 Max Horz 1=86(LC 5) Max Uplift 1=-9(LC 7), 4=-43(LC 7), 5=-19(LC 5) Max Grav 1=128(LC 10), 4=41(LC 1), 5=212(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V20 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525928 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-l_ixnM6KKlZkDmnShoNWsCokjSDf42KPtpj0TzzX3g4 Scale = 1:16.8 1 2 3 5 4 2x4 4x6 2x4 2x4 2x4 3-10-10 3-10-10 2-4-10 2-4-10 3-10-10 1-6-0 0-0-42-9-71-0-714.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-14] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.17 0.08 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)1=78/3-10-7, 4=50/3-10-7, 5=150/3-10-7 Max Horz 1=56(LC 5) Max Uplift 1=-28(LC 7), 4=-38(LC 7), 5=-10(LC 5) Max Grav 1=79(LC 10), 4=50(LC 1), 5=150(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V21 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525929 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-EAGK?i7y52hbrwLeFVulOQKxfrZApVwY5TSZ?PzX3g3 Scale = 1:9.3 1 2 3 2x4 3x4 2x4 0-0-3 0-0-3 2-2-7 2-2-4 1-1-4 1-1-4 2-2-7 1-1-4 0-0-41-3-70-0-414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-1] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.03 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=63/2-2-0, 3=63/2-2-0 Max Horz 1=22(LC 5) Max Uplift 1=-2(LC 7), 3=-2(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V22 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525930 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-iMpiC28asMpST4wqpDP_xdt3hFuPYy9iK6C7XrzX3g2 Scale = 1:19.0 1 2 3 2x4 2x4 2x4 2-8-10 2-8-10 0-0-43-2-114.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.20 0.13 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=92/2-8-6, 3=91/2-8-6 Max Horz 1=82(LC 6) Max Uplift 3=-56(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19901019 Truss V23 Truss Type Valley Qty 1 Ply 1 Wedgewood 39 Gray Oaks Job Reference (optional) I36525931 8.220 s Nov 16 2018 MiTek Industries, Inc. Tue Mar 26 12:14:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:CEuqc7_6VX2rPZi213Y_20yigU4-iMpiC28asMpST4wqpDP_xdt5eFvcYy9iK6C7XrzX3g2 Scale = 1:13.8 1 2 3 2x4 2x4 2x4 1-10-2 1-10-2 0-0-42-1-1314.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=57/1-9-15, 3=57/1-9-15 Max Horz 1=51(LC 6) Max Uplift 3=-34(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 26,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths