HomeMy WebLinkAboutGN001 - 39GO9' - 7 1/8" TO BOTTOM OF BULKHEAD
10' - 1 1/8" TO TOP OF PLATEBASE PER SPEC.
FLOATING TRIM BOX MANTLE
FIXED FIXED
CABINETS BELOWCABINETS BELOW
42" FIREPLACE 8' - 9 1/2" TO BOTTOM OF HEADER2' - 6"(2) FIXED SHELVES
(2) FIXED SHELVES
STONE FACE PER SPECS
± 1' - 1 3/4"5' - 0"4' - 6"BRICK SOLDIER HEADER
BRICK ROWLOCK SILL
4x12 CEDAR MANTLE ON 5-
3/4" X 10" X 4" STYLE G
CEDAR CORBELS
BRICK VENEER PER SPECS
42" FIREPLACE
1' - 0"1x6 CORNER TRIM TYP.
1x4 TRIM AGAINST BRICK BOTH
SIDES OF FIREPLACE
1x6 BAND BOARD w/METAL
DRIP EDGE TYP.
SLOPED BRICK ROWLOCK
SILL WITH 1/2" PROJ. TYP.
1x8 BAND BOARD CONTINUOUS
THROUGH COVERED PORCH
FIN. MAIN LEVEL
FIN. UPPER LEVEL
FINISHED LOWER LEVEL
T.O. PLATE (MAIN)
T.O. FOUNDATION
6' - 4 1/8"6' - 11 1/2"VENTED SOFFIT R-49 BLOWN INSULATION
BOTTOM TRUSS CHORD
SIDING
7/16" ROOF DECKING
ROOF SHINGLES PROVIDE 2" CLEARANCE
FOR INSULATION
SEE ROOF PLAN
12"
1/2" DRYWALL
2x6 STUD WALL
AT 16" O.C.
BRICK VENEER
7/16" ZIP WALL SHEATHING
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
3/4" DECKING
2x6 SILL PLATE
1/2" DRYWALL
R-19 INSULATION
METAL TIE
THROUGH WALL FLASHING
R-10 VINYL FACED BATT INSULATION
DOWN 4'-0" FROM TOP OF FNDN. WALL
NOTE: OFFSET FACE OF STUD 1/2"
FROM FACE OF FOUND. WALL
WATERPROOFING
TYPICAL FOUNDATION WALL:
* 8" POURED CONCRETE WALL
* SILL ANCHOR BOLTS @ 6'-0" O.C.
* 16"X8" CONCRETE FOOTING
* #3 STEEL WALL REINFORCING
2" FROM FACE OF WALL
* LOOP WIRE REINFORCING
4" CONC. SLAB ON GRADE
W/ 6 MIL. VAPOR BARRIER
4" MIN. GRANULAR FILL
GRANULAR FILL TO
12" ABOVE TOP OF
CONCRETE FOOTING
4" DRAIN TILE
4" DRAIN TILE
SLOPED BRICK ROWLOCK SILL
GRADE
CONCRETE FOOTER
IN UNFINISHED BASEMENT AREAS
R-13 BATT INSULATION
BETWEEN JOISTS TYP.
W/FIRESTONE RUBBER FLASHING
DRIP EDGE FLASHING TYP.
1x6 BAND BOARD w/METAL
(R-13 IN BASEMENT FINISHED WALLS)
SEE ELEV. FOR SIZE
SEE ELEVATION FOR HEIGHT1' - 0"OVERDIG
1' - 4"8"GUTTERBOARD, SEE ELEVATION
2X2 NAILER
2X2 @ 16" O.C.
3/8" PLYWOOD
FRIEZE- SEE ELEVATION
15# BUILDING FELT
CUSTOMER:
PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:Wedgewood
Building Co., LLC
317.669.6300
32 First Street NE
Carmel, IN 46032
www.wedgewoodbc.com
Copyright c 2019 Wedgewood Building Co. LLC. 3/20/2019
12:10:36 PM
ID1
The Owen Residence
Lot 39 - Gray Oaks
4777 Wellswood Bend, Carmel, IN 46033INTERIOR ELEVATIONS AND DETAILS ABL 1/2" = 1'-0"1 GREAT ROOM FIREPLACE ELEVATION
1/2" = 1'-0"4 LANAI FIREPLACE ELEVATION Rev.No. Date Description 1/2" = 1'-0"3 Section 1
3/4" = 1'-0" 2 TYPICAL WALL SECTION - NO UPPER LEVEL
GENERAL NOTES:
1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL.
Approved For Construction
Owner Signature: ____________________ Date: _________
Owner Signature: ____________________ Date: _________
Architect Signature: ____________________ Date: _________
Wedgewood Building Co. ,LLC
04/24/19
Mike Sheeks