HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property Organization
14261 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SOHO Michael Hill
Community: THE GROVE AT LEGA(
Builder
GLO53 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,237
$165
$331
$1,733
$769
SO
$2,502
Requirements
C-M,
Energy Solutions
As Designed
S1,176
S155
S331
$1,662
5769
S9
$2,431
C4405.3 Performance-based compliance passes by 4.1%
402.4.12 Air Leakage Testing Air sealing is 5.51) ACH at 5D Pa. It must not exceed 7.OD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 4.1%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
4112119 at 9:25 AM
Ekotrope RATER - Version 3.1.0.2150
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
14261 JAMES DEAN DR
CARMEL, IN 46033
Builder: PYATT BUILDERS, LLC
Model: SOHO Communitv: THE GROVE AT LEGACY 53
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor R-30
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5.5ACH50
Window U -Value: 0.3, Sill 0.26
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 136.0 CFM @ 25Pa
Total Duct Leakage 182.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 80 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party.
Name
Organization
Michael Hill
TSI Energy Solutions
Signature:
Date:
4112119 at 9:25 AM
Ekotrope RATER - Version 3.1.0.2150
2009 l compliance results calculated using Ekotrope RATER's energy and code camptance algorithm_
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability forthe information shown on this report.
Energy Code Inspection Checklist
Property Organization
14261 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SOHO Michael Hill
Community: THE GROVE AT LEGA(
GL053 (AS DESIGNED)
THE GROVE AT LEGACY 53
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Builder
PYATT BUILDERS, LLC
2,279
20,511
5,768
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (1,009 s.f.)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
El Name: GARAGE (253 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
El Name: AMBIENT (109 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (2,414 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIGAR (315 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
14261 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SOHO Michael Hill
Community: THE GROVE AT LEGA[
Builder
GLO53 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Name: CONDIATTIC (142 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (82 s.f.)
R: 11.691
Roof
Name: CONDIATTIC (73 s.f.)
R: 11.691
Name: MAIN (1,371 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (78 s.f.), U: 0.300, SHGC: 0.26, Orientation: EAST
E] Name: BACK (88 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST
El Name: SLIDER (80 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST
El Name: RIGHT SIDE (95 s.f.), U:0.300, SHGC: 0.26, Orientation: NORTH
El Name: LEFT SIDE (104 s.f.), U:0.300, SHGC: 0.26, Orientation: SOUTH
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization
14261 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SOHO Michael Hill
Community: THE GROVE AT LEGA[
GL053 (AS DESIGNED)
THE GROVE AT LEGACY 53
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
Builder
PYATT BUILDERS, LLC
inspection Status
Results are projected
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 80 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 1,880 CFM50 (5.50 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 136.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 182.0 CFM @ 25Pa
C-M,
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization
14261 JAMES DEAN DR TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: SOHO Michael Hill
Community: THE GROVE AT LEGA(
Builder
GL053 (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
14261 JAMES DEAN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46033
317-846-4655
Model: SOHO
Michael Hill
Community: THE GROVE AT LEGACY 53
Builder
GLG53 (AS DESIGNED)
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Effective R -value
Genera?Building Information
No 2
Number Of Bedrooms
3
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
2;279
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
20;511
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
SOHO
Community
THE GROVE AT LEGACY 53
Climate Zone
5A
I
Basement Wall
None Present
Basement Wall Library List
None Present
C-M,
Energy Solutions
Slab
Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 1'down, 2' in
164 On Grade 1.23
0 1,009.0 sq. R. Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Type
Slab Campletel� Underslab Insulation
Insulated. Width [ft]
Perimeter Insulation Perimeter Insulation R
Depth [ft] Value
Effective R -value
R-10, 1'down, 2' in Woad Frame / Other
No 2
1 1D
10.00
1
Building Summary
Library Type
Surface Calor
Name
Property
Organization
Inspection Status
C-MEnergy Solutions
14261 JAMES DEAN DR
TSI Energy Solutions
Results are projected
Medium
CARMEL, IN 46033
317-846-4655
Surface Area Location
CONDIAMB
Model: SOHO
Michael Hill
G1 R-15, OSB
82.0 sq. tt. Exposed Exterior
Community: THE GROVE AT LEGACY 53
G1 R-15, OSB
73.0 sq. ft. Attic
Builder
G1 R-15 Gar Walls
Medium
GL053 (AS DESIGNED)
PYATT BUILDERS, LLC
G1 R-15, OSB
THE GROVE AT LEGACY 53
ramed Floor
Name Library Type
Carpet R
Floor Grade
Surface Area Location
AMBIENT R-30, GR1
1.23
Above Grade
109.0 sq. ft Exposed Exterior
GARAGE R-30, GR1
253.0 sq. ft Unconditioned, attached
1.23
Above Grade
garage
Framed Floor Library List
Library Type
Surface Calor
Name
Effective R -value
CONDIAMB
-• »
27.493
Rim Joist i
G1 R-15 BATT, OSB
Medium
Name
Library Type
Surface Area Location
CONDIAMB
Attic
G1 R-15, OSB
82.0 sq. tt. Exposed Exterior
CONDIATTIC
G1 R-15, OSB
73.0 sq. ft. Attic
Rim Joist Library List
G1 R-15 Gar Walls
Medium
Name
Effective Insulation R -value
G1 R-15, OSB
11.691
Wall
Nance
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
Exposed Exterior
G1 R-15 BATT, OSB
Medium
2,414.0 sq. fl.
CONDIATTIC
Attic
G1 R-15 BATT, OSB
Medium
142.0 sq. fl.
CONDIGAR
Unconditioned, attached garage
G1 R-15 Gar Walls
Medium
315.0 sq. fl.
2
Building Summary
Property
Organization
Inspection Status
C-MEnergy
Solutions
14261 JAMES DEAN DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
317-846-4655
Model: SOHO
Michael Hill
Community: THE GROVE AT LEGACY 53
Builder
GL053 (AS DESIGNED)
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
FWall-fibrary List
Name
Effective R -value
G1 R-15 BATT, OSB
13.423
G1 R-15 Gar Walls
11.972
Glazing
Name Library Type Wall
Assignment Basement Wall Overhang
Assignment
Depth Overhang Pt
Top
To Overhang Pt To
Bottom
Orientation
Surface Area
BACK U-.30, SHGG26
CONDIAMB
0
0 0
West
88.0 sq. ft
FRONT U-.30, SHGG26
CONDIAMB
0
0 0
East
78.0 sq. ft
LEFT SIDE U-30, SHGG26
CONDIAMB
0
0 ❑
South
104.0 sq. ft.
RIGHT SIDE U-30, SHGG26
CONDIAMB
0
0 ❑
North
95.0 sq. fL
SLIDER U-30, SHGG26
CONDIAMB
0
0 ❑
West
80.0 sq. fL
Glazing Library List
Name
Shg c
U factor
U-.30, SHGC-26
026
0.300
Skylight
None Present
Skylight Library List
None Present
Building Summary
Property
Organization
14261 JAMES DEAN DR
TSI Energy Solutions
CARMEL, IN 46033
317-846-4655
Model: SOHO
Michael Hill
Community: THE GROVE AT LEGACY 53
Builder
GLG53 (AS DESIGNED)
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Fopaque DoolE���
Name Library Type WallAssignmen,
FRONT Steel Door CONDIAMB
GARAGE Steel Door CONDIGAR
sement Wall
Assign ment
Opaque Door Library List
J6
Name Effective U -factor
Steel Door 0.182
Inspection Status
Results are projected
Solar
Absorptance
C-M,
Energy Solutions
r Surface Area Location
0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior
0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
Vf.] Tiles
F•,1AIN R-38 Blown, GR1 '.371 No Medium 1,371.0 sq. R Attic
Roof Insulation Library Lisi
Name H.
IR-38 Blown, GR1
Whole House Infiltratiom
Infiltration A
5.5 ACH at 50 Pa
Mechanical Ventilation
No 38268
Blower -door tested 4
M
Building Summary
Property
Organization
14261 JAMES DEAN DR
TSI Energy Solutions
CARMEL, IN 46033
317-846-4655
Model: SOHO
Michael Hill
Community: THE GROVE AT LEGACY 53
Water Heating (3)
Builder
GL053 (AS DESIGNED)
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 53
Righting
% Interior Fluorescent °% Interior LED Lghting
% Exterior Fluorescent
Lighting
Lighting
0
0
Onsite Generation
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
)rescent °I Garage LED Lighting
Lighting
0 C
Onsite Generation Library List MMFMWPM�
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name
Library Type
Air conditioner (2)
CA13NA030
Fuel4red air
310AAV042090
distribution (1)
Water Heating (3)
RE350"
Heating Percent Load Cooling Percent Load Hot Water Percent Load
o% 100%
100% 0%
0%
0%
0% 0% 100%
Building Summary
Property
14261 JAMES DEAN DR
CARMEL, IN 460.33
Model: SOHO
Community: THE GROVE AT LEGACY 53
GLG53 (AS DESIGNED)
THE GROVE AT LEGACY 53
quipment Type:
Fuel Type
Distribution Type
Motor Type
Heating Efficiency
Heating Capacity [kBtulh]
Use default EAE
EAE [kWh]
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
310AAV042090
IIIIIIIIIIIIIIIIII�
Equipment Type: CA13NA030
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Natural Gas
Forced Air
PSG (Single Speed)
80 AFU E
71
No
848
Electric
Forced Air
PSG (Single Speed)
13 SEER
27.4
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
14261 JAMES DEAN DR
CARMEL, IN 460.33
Model: SOHO
Community: THE GROVE AT LEGACY 53
GLG53 (AS DESIGNED)
THE GROVE AT LEGACY 53
1butivn System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area [sq. ft.]
]uct Area [sq. ft_]
akage to Outdoors (CFM25)
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Forced Air
Fuel -f red air distribution (1)
Air conditioner (2)
2279
2
30
30
461.5
170.9
136
182
Post -Construction
Yes
Attic (well vented; under insulation)
50
50
Conditioned Space
50
50
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
14261 JAMES DEAN DR
CARMEL, IN 460.33
Model: SOHO
Community: THE GROVE AT LEGACY 53
GLG53 (AS DESIGNED)
THE GROVE AT LEGACY 53
ater Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
r
es Dryer
e
zation
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
FV I
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Standard
No
55
No
No
20
No
Electric
Timer Controls
704 kWh/Year
0.081kWh
$23.00
$0.581Therm
2.874
0.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions
,�