Loading...
HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGA( Builder GLO53 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,237 $165 $331 $1,733 $769 SO $2,502 Requirements C-M, Energy Solutions As Designed S1,176 S155 S331 $1,662 5769 S9 $2,431 C4405.3 Performance-based compliance passes by 4.1% 402.4.12 Air Leakage Testing Air sealing is 5.51) ACH at 5D Pa. It must not exceed 7.OD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 4.1%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 4112119 at 9:25 AM Ekotrope RATER - Version 3.1.0.2150 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14261 JAMES DEAN DR CARMEL, IN 46033 Builder: PYATT BUILDERS, LLC Model: SOHO Communitv: THE GROVE AT LEGACY 53 Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5.5ACH50 Window U -Value: 0.3, Sill 0.26 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 136.0 CFM @ 25Pa Total Duct Leakage 182.0 CFM @ 25Pa Heating Furnace • Natural Gas • 80 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party. Name Organization Michael Hill TSI Energy Solutions Signature: Date: 4112119 at 9:25 AM Ekotrope RATER - Version 3.1.0.2150 2009 l compliance results calculated using Ekotrope RATER's energy and code camptance algorithm_ Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability forthe information shown on this report. Energy Code Inspection Checklist Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGA( GL053 (AS DESIGNED) THE GROVE AT LEGACY 53 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Builder PYATT BUILDERS, LLC 2,279 20,511 5,768 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,009 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor El Name: GARAGE (253 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I El Name: AMBIENT (109 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (2,414 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIGAR (315 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGA[ Builder GLO53 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Name: CONDIATTIC (142 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (82 s.f.) R: 11.691 Roof Name: CONDIATTIC (73 s.f.) R: 11.691 Name: MAIN (1,371 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (78 s.f.), U: 0.300, SHGC: 0.26, Orientation: EAST E] Name: BACK (88 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST El Name: SLIDER (80 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST El Name: RIGHT SIDE (95 s.f.), U:0.300, SHGC: 0.26, Orientation: NORTH El Name: LEFT SIDE (104 s.f.), U:0.300, SHGC: 0.26, Orientation: SOUTH C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGA[ GL053 (AS DESIGNED) THE GROVE AT LEGACY 53 Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Builder PYATT BUILDERS, LLC inspection Status Results are projected 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 80 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,880 CFM50 (5.50 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 136.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 182.0 CFM @ 25Pa C-M, Energy Solutions 3 Energy Code Inspection Checklist Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGA( Builder GL053 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 14261 JAMES DEAN DR TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGACY 53 Builder GLG53 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Effective R -value Genera?Building Information No 2 Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 2;279 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 20;511 Total Units in Building 1 Residence Type Single family detached Floor Number Model SOHO Community THE GROVE AT LEGACY 53 Climate Zone 5A I Basement Wall None Present Basement Wall Library List None Present C-M, Energy Solutions Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 1'down, 2' in 164 On Grade 1.23 0 1,009.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Type Slab Campletel� Underslab Insulation Insulated. Width [ft] Perimeter Insulation Perimeter Insulation R Depth [ft] Value Effective R -value R-10, 1'down, 2' in Woad Frame / Other No 2 1 1D 10.00 1 Building Summary Library Type Surface Calor Name Property Organization Inspection Status C-MEnergy Solutions 14261 JAMES DEAN DR TSI Energy Solutions Results are projected Medium CARMEL, IN 46033 317-846-4655 Surface Area Location CONDIAMB Model: SOHO Michael Hill G1 R-15, OSB 82.0 sq. tt. Exposed Exterior Community: THE GROVE AT LEGACY 53 G1 R-15, OSB 73.0 sq. ft. Attic Builder G1 R-15 Gar Walls Medium GL053 (AS DESIGNED) PYATT BUILDERS, LLC G1 R-15, OSB THE GROVE AT LEGACY 53 ramed Floor Name Library Type Carpet R Floor Grade Surface Area Location AMBIENT R-30, GR1 1.23 Above Grade 109.0 sq. ft Exposed Exterior GARAGE R-30, GR1 253.0 sq. ft Unconditioned, attached 1.23 Above Grade garage Framed Floor Library List Library Type Surface Calor Name Effective R -value CONDIAMB -• » 27.493 Rim Joist i G1 R-15 BATT, OSB Medium Name Library Type Surface Area Location CONDIAMB Attic G1 R-15, OSB 82.0 sq. tt. Exposed Exterior CONDIATTIC G1 R-15, OSB 73.0 sq. ft. Attic Rim Joist Library List G1 R-15 Gar Walls Medium Name Effective Insulation R -value G1 R-15, OSB 11.691 Wall Nance Library Type Surface Calor Surface Area Location CONDIAMB Exposed Exterior G1 R-15 BATT, OSB Medium 2,414.0 sq. fl. CONDIATTIC Attic G1 R-15 BATT, OSB Medium 142.0 sq. fl. CONDIGAR Unconditioned, attached garage G1 R-15 Gar Walls Medium 315.0 sq. fl. 2 Building Summary Property Organization Inspection Status C-MEnergy Solutions 14261 JAMES DEAN DR TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGACY 53 Builder GL053 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 FWall-fibrary List Name Effective R -value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library Type Wall Assignment Basement Wall Overhang Assignment Depth Overhang Pt Top To Overhang Pt To Bottom Orientation Surface Area BACK U-.30, SHGG26 CONDIAMB 0 0 0 West 88.0 sq. ft FRONT U-.30, SHGG26 CONDIAMB 0 0 0 East 78.0 sq. ft LEFT SIDE U-30, SHGG26 CONDIAMB 0 0 ❑ South 104.0 sq. ft. RIGHT SIDE U-30, SHGG26 CONDIAMB 0 0 ❑ North 95.0 sq. fL SLIDER U-30, SHGG26 CONDIAMB 0 0 ❑ West 80.0 sq. fL Glazing Library List Name Shg c U factor U-.30, SHGC-26 026 0.300 Skylight None Present Skylight Library List None Present Building Summary Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGACY 53 Builder GLG53 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Fopaque DoolE��� Name Library Type WallAssignmen, FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR sement Wall Assign ment Opaque Door Library List J6 Name Effective U -factor Steel Door 0.182 Inspection Status Results are projected Solar Absorptance C-M, Energy Solutions r Surface Area Location 0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior 0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location Vf.] Tiles F•,1AIN R-38 Blown, GR1 '.371 No Medium 1,371.0 sq. R Attic Roof Insulation Library Lisi Name H. IR-38 Blown, GR1 Whole House Infiltratiom Infiltration A 5.5 ACH at 50 Pa Mechanical Ventilation No 38268 Blower -door tested 4 M Building Summary Property Organization 14261 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SOHO Michael Hill Community: THE GROVE AT LEGACY 53 Water Heating (3) Builder GL053 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 53 Righting % Interior Fluorescent °% Interior LED Lghting % Exterior Fluorescent Lighting Lighting 0 0 Onsite Generation None Present Inspection Status Results are projected C-M, Energy Solutions )rescent °I Garage LED Lighting Lighting 0 C Onsite Generation Library List MMFMWPM� None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Air conditioner (2) CA13NA030 Fuel4red air 310AAV042090 distribution (1) Water Heating (3) RE350" Heating Percent Load Cooling Percent Load Hot Water Percent Load o% 100% 100% 0% 0% 0% 0% 0% 100% Building Summary Property 14261 JAMES DEAN DR CARMEL, IN 460.33 Model: SOHO Community: THE GROVE AT LEGACY 53 GLG53 (AS DESIGNED) THE GROVE AT LEGACY 53 quipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 310AAV042090 IIIIIIIIIIIIIIIIII� Equipment Type: CA13NA030 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 80 AFU E 71 No 848 Electric Forced Air PSG (Single Speed) 13 SEER 27.4 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 14261 JAMES DEAN DR CARMEL, IN 460.33 Model: SOHO Community: THE GROVE AT LEGACY 53 GLG53 (AS DESIGNED) THE GROVE AT LEGACY 53 1butivn System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Forced Air Fuel -f red air distribution (1) Air conditioner (2) 2279 2 30 30 461.5 170.9 136 182 Post -Construction Yes Attic (well vented; under insulation) 50 50 Conditioned Space 50 50 Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 14261 JAMES DEAN DR CARMEL, IN 460.33 Model: SOHO Community: THE GROVE AT LEGACY 53 GLG53 (AS DESIGNED) THE GROVE AT LEGACY 53 ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? r es Dryer e zation Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmabie thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption FV I Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Standard No 55 No No 20 No Electric Timer Controls 704 kWh/Year 0.081kWh $23.00 $0.581Therm 2.874 0.331 Yes Standard 270 kWh Electric No No 709 kWh/Year Inspection Status Results are projected C-M, Energy Solutions ,�