CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:May 20, 2019
Project number Release date
407572 05/20/19
Construction type Occupancy classification
Scope of release
V-B B, REM
Type of release
Project name
Street address
City County
ARCH ELEC MECH
PLUM
Standard
Pure Pharmacy
12425 Old Meridian St
Ste B3
CARMEL HAMILTON
To: Owner / Architect / Engineer
MD Architects
Richard D. Renschen AR19900048
9084 Technology Dr
Ste 200
Fishers IN 46038
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
4G0412AE
14W1104A
14W09061
14B07037
This project has been reviewed under the 2014 Indiana Building Code.
The proposed building, addition, or remodel shall not put the existing building in noncompliance or
into further noncompliance in accordance with 675 IAC 12-4-12.
Required means of egress shall be maintained during construction and demolition, remodeling or
alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5).
Portable fire extinguishers shall be installed in accordance with Section 906.1, IFC (675 IAC 22-2.5).
Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or
stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic
spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet
measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in
height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording,
"FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with
Section 703.7, IBC (675 IAC 13-2.6).
NOTE: Walls and partitions within 2 feet (610 mm) of service sinks, urinals and water closets shall
have a smooth, hard, non-absorbent surface, to a height of not less than 4 feet (1219 mm) above
the floor, and except for structural elements, the materials used in such walls shall be of a type that
is not adversely affected by moisture. Accessories such as grab bars, towel bars, paper dispensers
and soap dishes, provided on or within walls, shall be installed and sealed to protect structural
elements from moisture in accordance with Section 1210.2.2, IBC (675 IAC 13-2.6).
NOTE: Doors in the means of egress in buildings and doors to tenant spaces in Group A, B, E, M,
R-1 or R-2, shall be permitted to be electromagnetically locked if equipped with listed hardware that
incorporates a built-in switch and meets the requirements of Section 1008.1.9.9, IBC (675 IAC 13-
2.6).
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
3175582827, rickr@mdarchitects.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
9E11026A
9E11026B
14B101163
14M030410
14M050131
14M0510
AREL
Access and working space shall be provided and maintained about all electric equipment in
accordance with Section 110.26, IEC (675 IAC 17-1.8).
Required working space about electrical equipment shall not be used for storage in accordance with
Section 110.26(B), IEC (675 IAC 17-1.8).
Exit illumination and exit signs shall be connected to a separate emergency power source in
accordance with Section 1011.6.3, IBC (675 IAC 13-2.6).
Equipment and appliances installed at grade level shall be supported on a level concrete slab or
other approved material extending not less than 3 inches above adjoining grade or shall be
suspended not less than 6 inches above adjoining grade, and shall be supported in accordance with
the manufacturer’s installation instructions, in accordance with Section 304.10, IMC (675 IAC 18-
1.6).
NOTE: Flexible air ducts, both metallic and nonmetallic, shall comply with Sections 603.6.1,
603.6.1.1, 603.6.3 and 603.6.4, IMC. Flexible air connectors, both metallic and nonmetallic, shall
comply with Sections 603.6.2 through 603.6.4, IMC, in accordance with Section 603.6, IMC (675
IAC 18-1.6).
The termination point of exhaust outlets and ducts discharging to the outdoors shall be located in
accordance with Section 501.3.1, IMC (675 IAC 18-1.6).
Hazardous exhaust systems shall comply with the requirements of Section 510, IMC (675 IAC 18-
1.6).
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
SEAN CALLAHAN
CHARLES KIPHART
ONE HAMILTON SQUARE SUITE 138
NOBLESVILLE,IN 46060
BUILDING COMMISSIONER
Fax & e-mail: 3177742559, Chuck.kiphart@hamiltoncounty.in.gov
Director, Division of Fire and Building Safety scallahan@dhs.in.gov