HomeMy WebLinkAboutS&S COMcheck - PURE PharmacyCOMcheck Software Version COMcheck-Web Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: 2018 IECC PURE Pharmacy Alteration Construction Site: Owner/Agent: Designer/Contractor: 12425 Old Meridian St., Suite B3 Carmel, Indiana 46032 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 1-Hospital 1913 1.05 2009 Total Allowed Watts = 2009 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. Hospital (1913 sq.ft.) LED: D1:6" DOWNLIGHT: Other: 1 1 20 20 LED: D2:6" DOWNLIGHT: Other: 1 4 16 62 LED: D4: 2" WALL WASHED LIGHT: Other: 1 4 16 62 LED: Rt: 2'X4' LAY-IN/GRID: LED Linear 33W: 1 14 38 532 LED: R2:2'X4' LAY-IN/GRID W/ACRYLIC LE: LED Panel 40W: 1 4 48 192 LED: VIA: FLEXIBLE LINEAR: Other: 1 1 20 20 LED: VIA/EM: EMERGENCY FLEXIBLE LINEAR: Other: 1 1 40 40 LED: Fl: 2'X4' FLAT PANEL: LED Panel 70W: 1 2 72 144 LED: F2: VX4' FLAT PANEL: LED Panel 40W: 1 4 45 180 LED: UC: UNDERCABINET LIGHTING: LED Undercabinet Unit 5.7W: 1 20 6 120 LED: X: EXIT SIGN: Other: 1 3 4 12 Total Proposed Watts = 1384 Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application, The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the InspIsa fnut++ _ VE ame - Title - — SignarL4 Dat w srarIT OF Project Title: PURE Pharmacy Report date; 04/15/19 Data filename: Page 1 of 15 COMcheck Software Version COMcheck-Web Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: PURE Pharmacy Location: Carmel, Indiana Climate Zone: 5a Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 12425 Old Meridian St., Suite B3 Carmel, Indiana 46032 Mechanical Systems List Quantity System Type & Description 1 HVAC System (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 120 kBtu/h Proposed Efficiency = 96.00% Et, Required Efficiency: 80.00 % Et or 80% AFUE Cooling: 1 each - Split System, Capacity = 56 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency= 13.75 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 1680 CFM, 1.0 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 100 kBtu/h Proposed Efficiency = 95,00% Et, Required Efficiency: 80.00 % Et or 80% AFUE Cooling: 1 each - Split System, Capacity= 47 kBtu/h, Air -Cooled Condenser, Air Economizer Proposed Efficiency= 15.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 1380 CFM, 0.8 motor nameplate hp, 0.0 fan efficiency grade 1 Water Heater: Gas Instantaneous Water Heater, Capacity: 10 gallons, Input Rating: 199 kBtu/h w/Circulation Pump No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented In this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the Inspection Checkli - ame - Title _ - Sig ur ,!p\IAv ItYVy'�Q.,,, Date Project Title: PURE Pharmacy Data filename: Report date: 04/15/19 Page 2 of 15 COMcheck Software Version COMcheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly In the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions r & Req,I C103,2 Plans, specifications, and/or❑Complies Requirement will be met. [PR211 'calculations provide all information Not ;with which compliance can be �❑Does Observable' determined for the mechanical❑Not Applicable systems and equipment and❑Not ; document where exceptions to the ;standard are claimed. Load 'calculations per acceptable ;engineering standards and ',handbooks. C103,2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR311 (calculations provide all information❑Does Not ;with which compliance can be j❑Not Observable; determined for the service water Applicable heating systems and equipment and❑Nat document where exceptions to the ;standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 ;Plans, specifications, and/or ;❑Complies 'Requirement will be met. [PR4I1 'calculations provide all information❑Does Not ;with which compliance can be Observable ;determined for the interior lighting❑Not Applicable 'and electrical systems and equipment❑Not $and document where exceptions to the standard are claimed. Information 'provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and 'control devices. C406 'Plans, specifications, and/or❑Complies Requirement will be met. [PR911 I calculations provide all information❑Does Not with which compliance can be Observable determined for the additional energy❑Not ;❑Not Applicable efficiency package options. Additional Comments/Assumptions: 1 High Impact (Tier 1) '2. Medium Impact (Tier 2) ':3 Low Impact (Tier 3) Protect Title: PURE Pharmacy Data filename: Report date: 04/15/19 Page 3 of is Snow/ice melting system and freeze ;Complies Requirement will be met, protection systems have sensors and :ODoes Not controls configured to limit service for pavement temperature and outdoor �oNot Observable; temperature. future connection to ;Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3:. Low Impact (Tier 3) Project Title: PURE Pharmacy Data filename: Report date: 04/15/19 Page 4 of 15 Section # Plumbing RoughAn Inspection Complies? Comments/Assumptions & Re ,ID C404 5, Heated water supply piping conforms❑complies ; Requirement will be met. C404.5.1; 'to pipe length and volume ❑Does Not C404.5.2 C requirements. Refer to section details.❑Not Observable; [PL6]3 :❑Not Applicable C404.51 ,` `:' Heated water supply piping conforms I❑Complies ! Requirement will be met. C404,5,11 to pipe length and volume❑Does Not C404.5.2 requirements. Refer to section details. I Observable; [PL6]3.:- `' li❑Not '❑Not Applicable C404.5, ': Heated water supply piping conforms❑Complies ;Requirement will be met. C404,5 1;'.'to pipe length and volume ❑Does Not C404.5 2 requirements, Refer to section details. ; Observable; [PL6]3 >,"❑Not ❑Not Applicable , C404.6.11 Automatic time switches installed to❑Complies Requirement will be met. C404.6.2 automatically switch off the❑Does Not [PL3]1 recirculating hot-water system or heat ❑Not Observable ; ;trace. I ❑Not Applicable C404,6:3 Pumps that circulate water between a ;❑Complies Requirement will be met. [PL7]3 ' heater and storage tank have controls❑Does Not j '. that limit operation from startup to❑Not Observable; <= 5 minutes after end of heating ❑Not Applicable cycle. C404.6:3. ; Pumps that circulate water between a❑Complies Requirement will be met. [PL7j3 heater and storage tank have controls❑Does Not that limit operation from startup to Observable <= 5 minutes after end of heating❑Not j❑Not Applicable lcyde. C404.6.3:':; Pumps that circulate water between a❑Complies ;Requirement will be met. [PL7]3 -'.i heater and storage tank have controls❑Does Not that limit operation from startup to Observable --:j <= 5 minutes after end of heating❑Not Applicable cycle.❑Not C404 7 Demand recirculation water systems❑Complies Requirement will be met. [PL8]3 ' have controls that start the pump ❑Does Not upon receiving a signal from the Observable :..`,appliance action of a user of a fixture or❑Not ❑Not Applicable and limits the temperature <:of the water entering the cold -water 7.I piping to 104°F. C404 7 '.. Demand recirculation water systems❑Complies Requirement will be met. [PL8]3 'have controls that start the pump ❑Does Not [;1 upon receiving a signal from the ❑Not Observable "]appliance 'action of a user of a fixture or and limits the temperature❑Not Applicable of the water entering the cold-water -':1 piping to 104°F. C404.7 r`-:I Demand recirculation water systems❑Complies Requirement will be met. [PL8]3 i 'have controls that start the pump❑Does Not i upon receiving a signal from the Observable; action of a user of a fixture or appliance and limits the temperature❑Not '❑Not Applicable of the water entering the cold -water '..I piping to 104°F. Additional Comments/Assumptions: 1 High Impact (Tier 1) ' 2`-s-s Medium Impact (Tier 2) '31. Low Impact (Tier 3) Project Title: PURE Pharmacy Report date; 04/15/19 Data filename: Page 5 of 15 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3`i low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 6 of 15 Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 ;Thermally ineffective panel surfaces of;❑Complies 'Requirement will be met, [ME41]3.'. 'sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable; ❑Not Applicable C403.113 HVAC piping insulation insulated in❑Complies ;Requirement will be met. [ME61]2 ,1 'accordance with Table C40311.3. ❑Does Not Insulation exposed to weather is Observable protected from damage and is❑Not Applicable provided with shielding from solar❑Not radiation. C403.11.3l HVAC piping insulation Insulated in❑Complies', Requirement will be met. [ME61]' :. ':'accordance with Table C403.11.3.❑Does Not f Insulation exposed to weather is Observable ,'. protected from damage and is❑Not provided with shielding from solar❑Not Applicable r, radiation. C403,8.4 Motors for fans that are not less than',❑Complies Requirement will be met, [ME142]2 ' 1/12 hp and less than 1 hp are ❑Does Not ,electronically commutated motors or Observable have a minimum motor efficiency of '❑Not 1❑Not Applicable ; 70 percent. These motors have the means to adjust motor speed. C403,84`::; Motors for fans that are not less than ;❑Complies 'Requirement will be met. [ME142]2;.i 1/12 hp and less than 1 hp are❑Does Not `;electronically commutated motors or❑Not Observable; <. have a minimum motor efficiency of I Applicable 70 percent. These motors have the❑Not means to adjust motor speed. C403 8,5`. Each DX cooling system > 65 kBtu ;❑Complies :Requirement will be met. [ME143]2: `; and chiller water/evaporative cooling '❑Does Not system with fans > 1/4 hp are❑Nat Observable 'designed to vary the indoor fan airflow 3 as a function of load and comply with ❑Not Applicable PP detailed requirements of this section. j C403,8 5= Each DX cooling system > 65 kBtu ;❑Complies ;Requirement will be met. [ME143]2::'and chiller water/evaporative coaling i❑Does Not .:.;system with fans > 1/4 hp are❑Not Observable; designed to vary the indoor fanairflowl❑NotAPP as a function of load and comply with Applicable Sl detailed requirements of this section. j C403,12,11j Systems that heat outside the building;❑Complies !Requirement will be met. [ME71]2 'envelope are radiant heat systems❑Does Not controlled by an occupancy sensing ❑Not Observable ',device or timer switch. ❑Not Applicable C403.2.3' Si HVAC equipment efficiency verified,❑Complies ;See the Mechanical Systems list for values. [ME55]2 ❑Does Not ❑Not Observable; "...'❑Not Applicable C403.5.5:>;. Fault detection and diagnostics ❑complies 'Requirement will be met. [ME113]2.''installed with air-cooled unitary DX❑Does Not ';units having economizers. ❑Not Observable; ;:.❑Not Applicable C403.2.2 ;Natural or mechanical ventilation is ❑Complies :Requirement will be met, [ME59]1 'provided in accordance with❑Does Not ;International Mechanical Code Observable; ;Chapter 4. Mechanical ventilation has❑Not Applicable capability to reduce outdoor air supply❑Not to minimum per IMC Chapter 4, 1 High Impact (Tier 1) `r2i'. Medium Impact (Tier 2) 13: Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 7 of 15 Section # Mechanical Rough -in Inspection Complies? Comments/Assumptions: & Req:ID C403.7.1 ;Demand control ventilation provided ❑Complies ;Requirement will be met. (ME5911 'for spaces >500 ft2 and >25❑Does Not people/1000 ft2 occupant density and Observable served by systems with air side❑Nat ;ONot Applicable economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. C403,7,2 '.; Enclosed parking garage ventilation I❑Complies Exception: Requirement does not apply. [ME115]3= has automatic contaminant detection I❑Does Not and capacity to stage or modulate Observable P I -,fans to 50 % or less of design capacity. ;❑Not ❑Not Applicable ; C403.7,6'; HVAC systems serving guestrooms in❑Complies Exception: Requirement does not apply. [ME141]3 'Group R-1 buildings with > 50 ❑Does Not j guestrooms: Each guestroom is ❑Not Observable ;., provided with controls that Applicable automatically manage temperature❑Not (` setpoint and ventilation (see sections C403.7.6.1 and C403,7,6,2). C403.7A Exhaust air energy recovery on ❑Complies Requirement will be met. [ME5711 ;systems meeting Table C403.7.4(1)❑Does Not ;and C403.7.4(2). ;❑Not Observable' ❑Not Applicable C4033,5 Kitchen exhaust systems comply with IOCompiies Exception: Requirement does not apply, [ME116]3.:.'replacement air and conditioned ;[]Does Not C. ;supply air limitations, and satisfy hood Observable 'I rating requirements and maximum❑Not Applicable exhaust rate criteria.❑Not C403.11.1` HVAC ducts and plenums insulated in ❑Complies Requirement will be met. accordance with C403.11,1 and❑Does Not C403.11.2constructed in accordance with IONot Observable P [ME6072.. `: C403.11.2, verification may need to Soccur ❑Not Applicable during Foundation Inspection, C403,51 ;Air economizers provided where I❑Complies Requirement will be met. C403.5.1, required, meet the requirements for ODoes Not C403,5.2 design capacity, control signal, Not Observable; [ME6211 ventilation controls, high -limit shut-off,'❑NotA 'integrated Applicable economizer control, and pP provide a means to relieve excess 'outside air during operation. C403.5.3.:Air economizers automatically reduce ;❑Complies Requirement will be met. 3 outdoor air intake to the design❑Does Not [ME124]1 'minimum outdoor air quantity when Observable: outdoor air intake will not reduce❑Not Applicable cooling energy usage. See Table❑Not C403,533 for applicable device types ;and climate zones. C403.5.3. 'System capable of relieving excess ❑Complies Requirement will be met. 4 outdoor air during air economizer ;[]Does Not [ME125]1 ;operation to prevent overpressurizing :❑Not Observable' 'the building. The relief air outlet 'located Applicable to avoid recirculation into the ;❑Not ;building. C403.5.3. Return, exhaust/relief and outdoor air ;[]Complies j Requirement will be met. 5 dampers used in economizers have ODoes Not [ME126]1 'motorized dampers that automatically ❑Not Observable; shut when not in use and meet 'maximum leakage rates, Reference []Not Applicable j section C403,7.7 for details. 1 High Impact (Tier 1) 2' Medium Impact (Tier 2) 3I'. Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 8 of 15 Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions 1. & Req.ID C403.4 1, Heating for vestibules and air curtains ❑Complies Requirement will be met. 4 with integral heating include Not [ME63]2 automatic controls that shut off the❑Not Observable; '. j heating system when outdoor air 'temperatures �ONot Applicable > 45F. Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= '.: 6OF and cooling setpoint >= 80F, C403.3.3 ;Hot gas bypass limited to: <=240 ',❑Complies ,Requirement will be met. (ME35]1 I ketu/h - 50 % >240 kBtu/h - 25 % I❑Does Not I❑Not Observable j ❑Not Applicable C403.3.3 Hot gas bypass limited to: <=240❑Complies Requirement will be met. [ME35]1 ; kBtu/h - 50 % >240 kBtu/h - 25 LIDoes Not I❑Not Observable; ❑Not Applicable C408,2,2:. ;Air outlets and zone terminal devices ❑Complies Requirement will be met, 1 ' have means for air balancing.❑Does Not (ME53]3 `. ;❑Not Observable `.i j❑Not Applicable C403.51 ` Refrigerated display cases, walk-in❑Complies Requirement will be met. C403.541, coolers or walk-in freezers served by❑Does Not C4035r2 I, remote compressors and remote ❑ Not Observable; [ME123]3 =l 'condensers not located in a Applicable condensing unit, have fan-powered❑Not 'condensers that comply with Sections )�C403.5,1 and refrigeration compressor; systems that comply with C403.5,2.. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3` Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 9 of 15 Section # Rough -In Electrical Inspection Complies? Comments/Assumptions' & Req.ID C405.2.2. ;Spaces required to have light- ❑Complies , Requirement will be met. 2 reduction controls have a manual❑Does Not [EL22]1 'control that allows the occupant to❑Not Observable; 'reduce the connected lighting load in Applicable 'a reasonably uniform illumination❑Not ;pattern >= 50 percent. C405.2,11 ;Occupancy sensors installed in❑Complies ;Requirement will be met. C405.2,1. (classrooms/lecture/training rooms,;❑Does Not 1 jconference/meeting/multipurpose [EL18]1 ',rooms, copy/print rooms, I❑Not Observable Applicable ' lounges/breakrooms, enclosed offices,❑Not ; ,open plan office areas, restrooms, ;storage rooms, locker rooms, 'warehouse storage areas, and other spaces <= 300 sqft that are enclosed by floor -to -ceiling height partitions. 'Reference section language C405.2,1,2 for control function in warehouses and section C405.2.1.3 ;for open plan office spaces. C405.2.1. Occupancy sensors control function in ;❑Complies Exception: Requirement does not apply. 2 'warehouses: In warehouses, the ;❑Does Not [EL1911 :lighting in aisleways and open areas is; Observable ,controlled with occupant sensors that :❑Not Applicable automatically reduce lighting power❑Not by 50 % or more when the areas are unoccupied, The occupant sensors control lighting In each aisleway independently and do not control lighting beyond the aisleway being controlled by the sensor. C405.2.1. ;Occupant sensor control function in❑Complies ;Requirement will be met. 3 open plan office areas: Occupant ❑Does Not [EL20]1 ;sensor controls in open office spaces ;❑Not Observable (>= 300 sq.ft, have controls 1) 'configured Applicable so that general lighting can;❑Not be controlled separately in control ;zones with floor areas <= 600 sq.ft. 'within the space, 2) automatically turn 1 'off general lighting in all control zones ;within 20 minutes after all occupants have left the space, 3) are configured tso that general lighting power in each ;control zone is reduced by >= 80 % of 'the full zone general lighting power ;within 20 minutes of all occupants leaving that control zone, and 4) are ;configured such that any daylight responsive control will activate space general lighting or control zone ;general lighting only when occupancy ;for the same area is detected. C405 2.2,E i Each area not served by occupancy ❑Complies Exception: Lighting that is related to means of egress in C405.2.2sensors (per C405.21) have time -❑Does Not 'stairways, ramps, corridors, or emergency routes. 1, ;switch controls and functions detailed❑Not Observable; C405.2.2i ) in sections C405.2.2.1 and C405.2.2.2. ❑Not Applicable j [EL21]2 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 31: Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename; Page 10 of 15 Section # Rough -in Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2 3, Daylight zones provided with ❑Complies ,Requirement will be met. C405.2.3, .) individual controls that control the ❑Does Not 1, lights independent of general area; Observable ot e C405.2.3::-, lighting. See code section C405.2.3 ❑❑NN ,t Applicable j 2 '. ] Daylight -responsive controls for [EL23]2 -„applicable spaces, C405.2.3.1 Daylight', ,responsive control function and -1 section C405.2.3.2 Sidelit zone. C405.2A I Separate lighting control devices for ❑Complies Requirement will be met. [EL26]1 specific uses installed per approved❑Does Not ;lighting plans.❑Not Observable; ❑Not Applicable C405.2.4 :Additional interior lighting power ❑Complies ;Requirement will be met. [EL2711 allowed for special functions per the❑Does Not ;approved lighting plans and is Observable automatically controlled and❑Not Applicable separated from general lighting.❑Not C405.3 Exit signs do not exceed 5 watts per ❑Complies ;Requirement will be met. [EL6]1 (face.❑Does Not FF ;❑Not Observable; ❑Not Applicable C405.6 ; Low -voltage dry -type distribution❑Complies Requirement will be met. [EL26]2 ': i electric transformers meet the❑Does Not minimum efficiency requirements of I❑Not Observable' Table C405.6. I ;ONot Applicable C405.7 ` Electric motors meet the minimum❑Complies ; Requirement will be met. [EL27]2 :I efficiency requirements of Tables❑Does Not �C405.7(1) through C405.7(4).❑Not Observable j Efficiency verified through certification,❑Not Applicable PP under an approved certification program or the equipment efficiency `',ratings shall be provided by motor I manufacturer (where certification programs do not exist). C405.8.2; :; Escalators and moving walks comply i❑Complies Exception: Requirement does not apply. C405,8.2 i' with ASME A17.1/CSA B44 and have❑Does Not 1 ;automatic controls configured to '; ❑ Not Observable; [EL28]2 '; reduce speed to the minimum Applicable l permitted speed in accordance with❑Not ' ASME A17.1/CSA B44 or applicable I local code when not conveying l passengers. C405.9-'I Total voltage drop across the !❑Complies ;Requirement will be met. [EL29]2 ` i combination of feeders and branch ❑Does Not , ,circuits a=5%. ',❑Not Observable; Applicable ,❑Not Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 : Medium Impact (Tier 2) 3+:. Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 11 of 15 Section # ' Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, :'. 11 Furnished O&M instructions for❑Complies ;Requirement will be met. C4082.5.',i systems and equipment to the❑Does Not 2 ; building owner or designated❑Not Observable j [F]17]3 `representative. jDNot Applicable C303.3, I Furnished O&M manuals for HVAC ;❑Complies Requirement will be met. C408 2,5, ;I systems within 90 days of system ❑Does Not 3 .'acceptance. [FI8] 3 ;❑Not Observable', ❑Not Applicable C403 2.2 HVAC systems and equipment❑complies Requirement will be met. (FI2713 ' :' capacity does not exceed calculated ❑Does Not :l loads. I❑Not Observable; ❑Not Applicable C403 2.4.:: Heating and cooling to each zone is ❑Complies Requirement will be met. 1 -<( controlled by a thermostat control. :[]Does Not (FI47]3 'Minimum one humidity control device Observable; per installed❑Not I humidification/dehumidification❑Not Applicable system. C403.2 A, EI Heating and cooling to each zone is ❑Complies ; Requirement will be met. 1 'controlled by a thermostat control. !❑Does Not [FI47]3 Minimum one humidity control device Observable; iI '.' per installed❑Not 'humidification/dehumidification❑Not Applicable j system. C403AJ, "Thermostatic controls have a 5 OF I ❑Complies 'Requirement will be met. 2 deadband.❑Does Not [FI38]3❑Not Observable; ❑Not Applicable C403.2A,,:i Temperature controls have setpoint ❑Complies Requirement will be met. 143 overlap restrictions.❑Does Not [FI20]3❑Not Observable; ,I ;❑Not Applicable C403,2 4 ' Each zone equipped with setback ❑Complies ;Requirement will be met. 2 controls using automatic time clock or ;❑Does Not [FI39]3 programmable control system.❑Not Observable; ❑Not Applicable C403.2.4: -; Automatic Controls; Setback to 55"F❑Complies ;Requirement will be met. 2,11 I; 1(heat) and 850F (cool); 7-day clock, 2- ❑Does Not C403.2A, hour occupant override, 10-hour ;❑Not Observable; 2.2 -:; [F14013.. ;;:i❑Not backup Applicable C403.2.4. Systems include optimum start❑Complies Requirement will be met. 23 ''controls. '❑Does Not [FI41]3 ;❑Not Observable; ;❑Not Applicable C4033:4 1:, Systems include optimum start ❑Complies Requirement will be met, 2.3 :.I controls. Not [F]4113 ;❑Not Observable; I❑Not Applicable C404.3 'I Heat traps installed on supply and ;❑Complies Requirement will be met. [FI11)3 '; dl discharge piping of non -circulating j❑Does Not systems. j❑Not Observable 'I I❑Not Applicable 1 High Impact (Tier 1) 2'r Medium Impact (Tier 2) 3.. Law Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 12 of 15 Section # 'Final Inspection Complies? Comments/Assumptions & RegJ C404A `. ; All piping Insulated in accordance with ❑Complies Requirement will be met. [FI2512 3 '; section details and Table C403.11. ❑Does Not P ❑Not Observable '❑Not Applicable C404,6.1 i'; Controls are installed that limit the❑Complies Requirement will be met, [FI12]3 'operation of a recirculation pump ❑Does Not `. installed to maintain temperature of a ❑Not Observable storage tank. System return pipe is a Applicable dedicated return pipe or a cold water❑Not :. I supply pipe. C405.4.1 ;Interior installed lamp and fixture❑Complies See the Interior Lighting fixture schedule for values. [FI1811 'lighting power is consistent with what❑Does Not is shown on the approved lighting I❑Not Observable, plans, demonstrating proposed watts Applicable ; are less than or equal to allowed❑Not ;watts, C408.1,1 ;Building operations and maintenance❑Complies Requirement will be met. [FI57]1 'documents will be provided to the ❑Does Not ;owner, Documents will cover ❑Not Observable) manufacturers' information, Applicable ,specifications, programming❑Not procedures and means of illustrating j ',to owner how building, equipment and' systems are intended to be Installed, maintained, and operated. C408.2.1 ;Commissioning plan developed by❑Complies ;Requirement will be met. [F12811 'registered design professional or❑Does Not ;approved agency. ;❑Not Observable; ❑Not Applicable C408.2.3. ! HVAC equipment has been tested to !OComplies Requirement will be met. 1 ensure proper operation.❑Does Not [FI31]' ;❑Not Observable; ❑Not Applicable C408.2.3. HVAC control systems have been I❑Complies Requirement will be met. 2 ;tested to ensure proper operation,❑Does Not [FI10]1 'calibration and adjustment of controls. , ❑Not Observable; ❑Not Applicable C408,23. ;Economizers have been tested to I❑Complies Requirement will be met. 3 1 ensure proper operation. Not [FI32]1❑Not Observable j ❑Not Applicable C408.2,4 Preliminary commissioning report❑Complies Requirement will be met. [FI2911 'completed and certified by registered ❑Does Not design professional or approved Observable; ;agency.❑Not ❑Not Applicable C40825'; Furnished HVAC as -built drawings❑Complies Requirement will be met. 1 i'I submitted within 90 days of system❑Does Not [FI7]3 ,acceptance. ;❑Not Observable; ❑Not Applicable C408.2.5, f Furnished as -built drawings for ❑Complies Requirement will be met. 1 '. 1 electric power systems within 90 days❑Does Not [FI1613 I ;of system acceptance. ;❑Not Observable; ❑Not Applicable 1 High Impact (Tier 1) I2+i Medium Impact (Tier 2) 13t Low Impact (Tier 3) Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 13 of 15 Section # Final Inspection Complies? Comments/Assumptions & Req.ID - C408.2.5. An air and/or hydronic system❑Complies ;Requirement will be met. 3 'balancing report is provided for HVAC I❑Does Not [F143]1 'systems. I❑Not Observable j❑Not Applicable C408,2.5. Final commissioning report due to 1❑Complies ;Requirement will be met. 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. '❑Not Observable ; ❑Not Applicable C4083 ;Lighting systems have been tested to ❑Complies 'Requirement will be met, [F133]1 ensure proper calibration, adjustment,❑Does Not programming, and operation. ❑Not Observable; ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2' Medium Impact (Tier 2) 3:. Low Impact (Tier 3) Project Titie: PURE Pharmacy Report date: 04/15/19 Data filename: Page 14 of 15 Project Title: PURE Pharmacy Report date: 04/15/19 Data filename: Page 15 of 15