HomeMy WebLinkAbout190523 PURE Pharmacy Permit 12-E10CU-1 CU-2
4_B, 0-1 /2"C
UI 10
A'8, 10,1
FLOOR PLAN - MISCELLANEOUS POWER
SCALE: 1/4" = V-0"
RELEASED FOR CONS'
Subject to compliance with all
of State and Local Coy
City ofCalmel
lj "CI
LIGHT FIXTURE SCHEDULE
SYM
MARK
DESCRIPTION
MFG
CATALOG#
LAMP TYPE
VOLTAGE
MOUNTING
REMARKS
0
D1
6" RECESSED LED DOWNLIGHT
HALO
PD620EDO1OB PDM6B835 61VC
/ /
LED DOW
UNIV
RECESSED
COMMERCIAL
®
D2
6" RECESSED DECORATIVE LED DOWNLGHT
SPECIALTY
340-68-15—DO10/340—
LED 15.5W
UNIV
RECESSED
PRODUCTS
EU6B102090335-6LBWI LI—GFF
D4
4" RECESSED WALL WASHED LED
HALO
LD4810DO10
LED 15.5W
UNIV
RECESSED
COMMERCIAL
R1
2L X 4' LED DIRECT/INDIRECT TROFFER
METALUX
24EN—LD2-45—UNV—L835—
CD1—U
LED 38W
UNIV
GRID / LAY —IN
AMR1/EM
2' X 4' LED DIRECT/INDIRECT TROFFER W/
METALUX
24EN-02-45—UNV—ELI4W—
LED 38W
UNIV
GRID / LAY —IN
EMERGENCY INSTALLED
L835—CD1—U
®
IRS
2' X 4' LED TROFFER W/ ACRYLIC LENS
METALUX
24GR—LO5-64—F1—UNV—L835
LED 48W
UNIV
GRID / LAY —IN
D1—U
R6/EM
1 X 4' LED TROFFER W/ ACRYLIC LENS
METALUX
24CZ—LD5-50—UNV—ELI4W—
LED 22W
UNIV
GRID / LAY —IN
®
W/ EMERGENCY INSTALLED
L835—CD1—U
NA
FLEXIBLE LINEAR LED LUMINARE
LUMENWREX
VIA2PD—HLO—LED-80-500-30—
LED 20W
120 V
RECESSED
5'-120-D1-1
NA/EM
EMERGENCY FLEXIBLE LINEAR LED LUMINARE
LUMENWREX
VIA2PD-HLO-LED-80-500-30-
LED 40W
120 V
RECESSED
90-120-D1-EM
FolF1
2' X 4' LED FLAT PANEL
ENERGY
HARNESS
EHF-PANEL-2X4-724OK-277/
LED 72W
UNIV
RECESSED
PROVIDED BY OTHERS
PVBJRX93P
0
F2
V X 4' LED FLAT PANEL
ENERGY
EHF-PANEL-iX4-454OK-277/
LED 45W
UNIV
RECESSED
PROVIDED BY OTHERS
HARNESS
PE78N25V
SURFACE
CONTACT MELINDA BROCK FOR
UC
UNDERCABINET LENSED LED COVED LIGHTING
SPECIFIED
SEE REMARKS
LED 5W/Fi
UNN
(UNDERCABINET)
CORRECT MODEL #
LIGHTING
317-577-8338
®
g
EDGE -LIT EXIT SIGN WITH 90 MIN,
EMERGENCY BALLAST
SURE -CITES
EUS70R
LED 3.9W
UNIV
SURFACE
COLOR: RED LETTERS
GENERAL NOTES:
1, NO ALTERNATES WILL BE ACCEPTED FOR LIGHT FIXTURES UNLESS CONTRACTOR RECEIVES PRIOR APPROVAL DURING THE BIDDING PROCESS. ONCE THE CONTRACT IS AWARDED NO ALTERNATES WILL BE ACCEPTED.
GENERAL NOTES I
1. LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF SUSPENDED CEILINGS
OR THE SUSPENDED CEILING SHALL BE SUPPORTED WITHIN SIX (6) INCHES OF
EACH CORNER OF THE FIXTURE IN ACCORDANCE WITH ASTM C 636-76.
2. ALL WALL AND CEILING VACANCY SENSORS IN CONJUNCTION WITH LOW VOLTAGE
SWITCHES SHALL BE MANUAL ON/OFF, AUTO OFF UNLESS NOTED OTHERWISE.
3. ALL LUMINAIRES AND LIGHTING CONTROL DEVICES IN AN ENCLOSED SPACE/ROOM
ARE CIRCUITED TO THE SAME CIRCUIT. THE CIRCUIT NUMBER INDICATED BY LIGHT
FIXTURE.
4. IN A SPACE/ROOM WHERE THERE ARE MULTIPLE OCCUPANCY SENSORS, THE
OCCUPANCY SENSORS SHALL BE WIRED AND/OR PROGRAMMED TO OPERATE IN
PARALLEL SUCH THAT THE OCCUPANCY SENSOR SWITCHES ALL OF THE LIGHTING
AT THE SAME TIME.
KEY NOTES ® I
1. EMERGENCY LIGHT FIXTURE INDICATED SHALL FUNCTION AS AN UNSWITCHED NIGH
LIGHT,
2. FURNISH AND INSTALL NEW CEILING MOUNTED WATT STOPPER, MODEL #W-1000A
ULTRASONIC CEILING SENSOR MOTION DETECTOR AND BZ-50 POWER PACK FOR
CONTROL OF LIGHTING IN THIS AREA.
3. FURNISH AND INSTALL NEW SWITCH BANK FOR RECEPTION/WAITING AREA LIGHTS.
VERIFY MOUNTING HEIGHT WITH HOSPITAL PRIOR TO INSTALLATION.
4. EXISTING 120/208 VOLT, 3 PHASE, 200 AMP PANEL, DESIGNATED PANEL 'A', TO
BE RELOCATED AND INSTALLED AT INDICATED LOCATION. COMPLETE REWORK OF
CIRCUITRY ANTICIPATED. SEE SHEET E3.0 FOR MORE INFORMATION.
5. EXISTING RECEPTACLE TO BE INSTALLED AND RECIRCUITED AS SHOWN,
COORDINATE NEW MOUNTING HEIGHT WITH PHARMACY.
6. FURNISH AND INSTALL GFCI DUPLEX OUTLET FOR ELECTRIC WATER COOLER.
SEE MANUFACTURERS SPECIFICATIONS FOR EXACT LOCATION AND MOUNTING
HEIGHT OF RECEPTACLE - COORDINATE INSTALLATION OF RECEPTACLE WITH
INSTALLATION OF WATER COOLER.
7. ROUTE ALL CONDUIT AND WIRING THROUGH RECEPTION DESK AS REQUIRED,
NO CONDUIT SHALL BE EXPOSED. COORDINATE MOUNTING HEIGHT WITH
PHARMACY.
8. MISCELLANEOUS POWER AND LOW VOLTAGE TO RUN THROUGH TRENCH
UNDER FLOOR, EACH IN SEPARATE CONDUIT, TO RECEPTION DESK AS
SHOWN. FOR LOW VOLTAGE INFORMATION REFER TO SHEET E2.0.
9, FURNISH AND INSTALL NEW DIMMER SWITCH FOR LED TAPE ACCENT LIGHTING
-US". MODEL #IP710-LFZ
10, COORDINATE EXACT MOUNTING HEIGHT OF RECEPTACLE AND MONITOR WITH
PHARMACY.
11, CURRENT LOCATION OF EXISTING PANEL TO BE RELOCATED TO LOCATION SHOWN
IN BREAKROOM.
12. FURNISH AND INSTALL NEW DISCONNECT SWITCH ON EXTERIOR WALL FOR NEW
CONDENSING UNIT. SQUARE D, MODEL #H321NRB (30/30, NEVA 3R).
13. FURNISH AND INSTALL NEW MECHANICAL EQUIPMENT IN SAME LOCATION AS
EXISTING MECHANICAL EQUIPMENT UP IN ATTIC SPACE.
14, LIGHT SWITCH AND LIGHTS IN DESIGNATED ROOM PROVIDED BY OTHERS.
COORDINATE WITH MODULAR DRAWINGS. CONDUIT SHOWN FOR INFORMATIONAL
PURPOSES ONLY TO SHOW HOW LIGHTS SHOULD BE TIED INTO REST OF SPACE.
15, JUNCTION BOX TO BE ABOVE FINISHED CEILING. COORDINATE MOUNTING HEIGHT
WITH INSTALLATION OF TANKLESS WATER HEATER AND HOT WATER RECIRCULATION
PUMP.
16. RECEPTACLES IN THIS AREA PROVIDED BY OTHERS. COORDINATE MOUNTING HEIGH"
WITH PHARMACY AND BIOLOGICS MODULAR UNLESS OTHERWISE NOTED. SEE NOTE
17 FOR WHIP BEING PROVIDED FOR ALL CONDUIT RUNS.
17. WHIP TO BE PROVIDED BY OTHERS FOR EXTENSION/CONNECTION TO PANEL BY
PROJECT ELECTRICAL CONTRACTOR.
18. NEW EXHAUST FAN SHALL BE CONNECTED TO NEAREST LIGHTING CIRCUIT AND
ASSOCIATED SWITCH IN THE AREA. (GREENHECK, MODEL #SO-60HP-D).
19. COMPOUNDING AREA WORK BY OTHERS. INFORMATION FOR
SYSTEMS/EQUIPMENT/MATERIAL SHOWN FOR INFORMATION ONLY. ALL WORK
INDICATED IN THE AREA SHALL BE (UON) FURNISHED AND INSTALLED BY
BIOLOGICS MODULAR. CONTACT JULIAN KARRAS, VP OF OPERATIONS, AT
(317-456-9191) FOR PRICING/PROVISIONS OF THEIR EQUIPMENT.
20. CONTRACTOR TO FURNISH AND INSTALL ROOF MOUNTED EXHAUST FAN INSIDE
COMPOUNDING AREA BOUNDARIES AS INDICATED. COORDINATE WITH BIOLOGICS
MODULAR.
21, UNDERCABINET LIGHTING IS 13 X 12" SECTIONS OF COVED LED LIGHTING.
UNDERCABINET TO BE CIRCUITED AS SHOWN. REFER TO LIGHTING SCHEDULE FOR
MORE INFORMATION.
Ia
.11. ARCHITECTS, PC
a184 TECHNOLOGY DRIVE
HSHERS, IN 46039
TEL 517558.2022
FAX S17.%JA27
rml.mderchimcre.am
Sr= NCER
�NGINEE2ING-
1533 EAST NORTHFIELD DRIVE
SUITE 400
DWWPING P SPICING
CON
Y
O
J
Q
U_
1.1.
U
W
J
W
z
Q
J
a
N
W
O
O
J
un
No.
NC03982
STATE OF
d
�
ao
a
o
a3
O
00 ou
JLL'
LLW
a
£
W
LU
w