HomeMy WebLinkAbout190523 PURE Pharmacy Permit 13-E20FLOOR PLAN - LOW VOLTAGE WORK
SCALE: 1/4" = V-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City offCannel
�Nq�\D.kMWA�
TERMINATE ABOVE CF"'"'^
WITH BUSHED END P
PULL STRING
CE
FL
TELEPHONE
1. ALL DATA AND VOICE OUTLETS ARE MOUNTED BELOW COUNTER OR +24" AFF (TO
CENTER), UNLESS OTHERWISE NOTED.
2. ELECTRICIAN AND DATA CABLING INSTALLER SHALL COORDINATE EXACT HEIGHTS OF
BOXES WITH INTERIOR ELEVATION SHEETS.
3. ELECTRICIAN IS TO PROVIDE CABLE MANAGEMENT RACKS AT UNDERSIDE OF ALL
WORKSTATION LOCATIONS. TYPE OF RACK TO BE DETERMINED.
4. GC TO PROVIDE (2) 4" EMT SLEEVES IN HE CEILING FOR THE I.T. CABLING
PENETRATIONS.
5. PURPOSE OF THIS PLAN IS TO ILLUSTRATE VOICE AND DATA LOCATIONS ONLY.
VCA TO COORDINATE WITH I.T. REPRESENTATIVE.
6. DEVICES SHOWN HERE SHOULD BE INCLUDED IN FINAL PLAN, BUT NO LIMITED TO
THESE LOCATIONS. FINAL PLAN SHALL MEET ALL APPLICABLE CODES.
T ALL SECURITY, ACCESS, ETC. SHALL BE PROVIDED BY INTRUSION ALARM
INSTALLER.
S. G.C. SHALL PROVIDE AND INSTALL ALL POWER, CONDUIT AND JUNCTION BOXES
FOR ALL SECURITY DEVICES INDICATED ON THIS SET OF DRAWINGS. COORDINATE
WITH SECURITY VENDOR PRIOR TO BID, ROUGH —IN AND INSTALLATION TO INCLUDE
ALL WORK IN BASE BID. NO EXTRAS WILL BE ALLOWED IF NOT COORDINATED
PRIOR TO BID.
9. ALL CABLING FOR SECURITY MONITOR TO BE HD CABLING.
10. INTERIOR ACCESS CONTROL DOORS REQUIRE CONDUIT, BOXES, RACEWAY, AND/OR
STUB THEO ORE BY ELECTRICIAN.
11, EXTERIOR DOORS WILL REQUIRE 3/4" CONDUIT STUB UP TO PLENUM CEILING
WITH STUB THROUGH EXTERIOR WALL TO 42" AFF FOR READERS AND INTERCOMS.
12. ALL EXTERIOR ACCESS CONTROL DOORS ARE TO HAVE TWO (2) RECESSED
CONTACTS. ONE FOR INTRUSION, ONE FOR ACCESS CONTROL. NO DOUBLE
POLE/DOUBLE THROW CONTACTS ALLOWED.
13, REFERENCE TELEPHONE/DATA CONDUIT DETAIL" FOR ALL TELEPHONE/DATA BOXES
(TYPICAL).
KEYNOTES
I. REFER TO SHEET E2.0 FOR CONDUIT IN TRENCH NOTES. CONDUIT FOR LOW
VOLTAGE TO BE SEPARATE FROM MISCELLANEOUS POWER. COORDINATE MOUNTING
HEIGHT WITH PHARMACY.
2, COORDINATE MOUNTING HEIGHT WITH INSTALLATION OF MONITOR.
3, COMPOUNDING AREA WORK BY OTHERS. INFORMATION FOR
SYSTEMS/EQUIPMENT/MATERIAL SHOWN FOR INFORMATION ONLY. ALL WORK
INDICATED IN THE AREA SHALL BE (UON) FURNISHED AND INSTALLED BY
BIOLOGICS MODULAR. CONTACT JULIAN KARRAS, VP OF OPERATIONS, AT
(317-456-9191) FOR PRICING/PROVISIONS OF THEIR EQUIPMENT.
4. CONTRACTOR TO INSTALL TELEPHONE BOX INSIDE COMPOUNDING AREA
BOUNDARIES AS SHOWN. COORDINATE INSTALLATION WITH BIOLOGICS MODULAR.
HIT
4" x 2-1/4" J. BOX
ATA CONDUIT DETAIL
NOT TO SCALE
Ia
.11. ARCHITECTS, PC
a]34 TECHNOLOGY DRIVE
FlSHERS, IN 4a39
TEL 917556.2a22
FAX 817,MS. B27
rm ivilarchimcre.am
Sr= NCER
�NGINEE2ING-
1533 EAST NORTHFIELD DRIVE
SUITE 400
DWWW SPENCOERMEP CON
Y
Li.
0
,W
V
Q
J
0
0
J
Z
Q
J
a
W
0
0
J
LL
04v3982
STATE OF
a
�
Wy
s
0
60
O
�
003
E
LL°
N
ow.
W
WLL
aw€
Eo
nw_
s
zQ
LZ
maa
O01
o0�p
�3r
ogLL
ova
o3
�m
DATE: 05/30/19