HomeMy WebLinkAbout190523 PURE Pharmacy Permit 13-E20FLOOR PLAN - LOW VOLTAGE WORK SCALE: 1/4" = V-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City offCannel �Nq�\D.kMWA� TERMINATE ABOVE CF"'"'^ WITH BUSHED END P PULL STRING CE FL TELEPHONE 1. ALL DATA AND VOICE OUTLETS ARE MOUNTED BELOW COUNTER OR +24" AFF (TO CENTER), UNLESS OTHERWISE NOTED. 2. ELECTRICIAN AND DATA CABLING INSTALLER SHALL COORDINATE EXACT HEIGHTS OF BOXES WITH INTERIOR ELEVATION SHEETS. 3. ELECTRICIAN IS TO PROVIDE CABLE MANAGEMENT RACKS AT UNDERSIDE OF ALL WORKSTATION LOCATIONS. TYPE OF RACK TO BE DETERMINED. 4. GC TO PROVIDE (2) 4" EMT SLEEVES IN HE CEILING FOR THE I.T. CABLING PENETRATIONS. 5. PURPOSE OF THIS PLAN IS TO ILLUSTRATE VOICE AND DATA LOCATIONS ONLY. VCA TO COORDINATE WITH I.T. REPRESENTATIVE. 6. DEVICES SHOWN HERE SHOULD BE INCLUDED IN FINAL PLAN, BUT NO LIMITED TO THESE LOCATIONS. FINAL PLAN SHALL MEET ALL APPLICABLE CODES. T ALL SECURITY, ACCESS, ETC. SHALL BE PROVIDED BY INTRUSION ALARM INSTALLER. S. G.C. SHALL PROVIDE AND INSTALL ALL POWER, CONDUIT AND JUNCTION BOXES FOR ALL SECURITY DEVICES INDICATED ON THIS SET OF DRAWINGS. COORDINATE WITH SECURITY VENDOR PRIOR TO BID, ROUGH —IN AND INSTALLATION TO INCLUDE ALL WORK IN BASE BID. NO EXTRAS WILL BE ALLOWED IF NOT COORDINATED PRIOR TO BID. 9. ALL CABLING FOR SECURITY MONITOR TO BE HD CABLING. 10. INTERIOR ACCESS CONTROL DOORS REQUIRE CONDUIT, BOXES, RACEWAY, AND/OR STUB THEO ORE BY ELECTRICIAN. 11, EXTERIOR DOORS WILL REQUIRE 3/4" CONDUIT STUB UP TO PLENUM CEILING WITH STUB THROUGH EXTERIOR WALL TO 42" AFF FOR READERS AND INTERCOMS. 12. ALL EXTERIOR ACCESS CONTROL DOORS ARE TO HAVE TWO (2) RECESSED CONTACTS. ONE FOR INTRUSION, ONE FOR ACCESS CONTROL. NO DOUBLE POLE/DOUBLE THROW CONTACTS ALLOWED. 13, REFERENCE TELEPHONE/DATA CONDUIT DETAIL" FOR ALL TELEPHONE/DATA BOXES (TYPICAL). KEYNOTES I. REFER TO SHEET E2.0 FOR CONDUIT IN TRENCH NOTES. CONDUIT FOR LOW VOLTAGE TO BE SEPARATE FROM MISCELLANEOUS POWER. COORDINATE MOUNTING HEIGHT WITH PHARMACY. 2, COORDINATE MOUNTING HEIGHT WITH INSTALLATION OF MONITOR. 3, COMPOUNDING AREA WORK BY OTHERS. INFORMATION FOR SYSTEMS/EQUIPMENT/MATERIAL SHOWN FOR INFORMATION ONLY. ALL WORK INDICATED IN THE AREA SHALL BE (UON) FURNISHED AND INSTALLED BY BIOLOGICS MODULAR. CONTACT JULIAN KARRAS, VP OF OPERATIONS, AT (317-456-9191) FOR PRICING/PROVISIONS OF THEIR EQUIPMENT. 4. CONTRACTOR TO INSTALL TELEPHONE BOX INSIDE COMPOUNDING AREA BOUNDARIES AS SHOWN. COORDINATE INSTALLATION WITH BIOLOGICS MODULAR. HIT 4" x 2-1/4" J. BOX ATA CONDUIT DETAIL NOT TO SCALE Ia .11. ARCHITECTS, PC a]34 TECHNOLOGY DRIVE FlSHERS, IN 4a39 TEL 917556.2a22 FAX 817,MS. B27 rm ivilarchimcre.am Sr= NCER �NGINEE2ING- 1533 EAST NORTHFIELD DRIVE SUITE 400 DWWW SPENCOERMEP CON Y Li. 0 ,W V Q J 0 0 J Z Q J a W 0 0 J LL 04v3982 STATE OF a � Wy s 0 60 O � 003 E LL° N ow. W WLL aw€ Eo nw_ s zQ LZ maa O01 o0�p �3r ogLL ova o3 �m DATE: 05/30/19