HomeMy WebLinkAbout190523 PURE Pharmacy Permit 16-M10CU_1 CU_2 O • -� (TYPICAL) RELEASED FOR CONS' Subject to compliance with all of State and Local Coy City ofCarmel lj "CI VENTURI VALVE & CONTROLLER (S—NH #113) vv_1 TX GENERATORPROTECTED OVAC 18 AWG/2 CONDUCTOR/SHIELDED 16 AWG/2 CONDUCTOR SIGNAL WIRING 24 VAC POWER WIRING RPM 1 ' 10 RPM 2 ROOM PRESSURE MONITOR ROOM PRESSURE MONITOR (S—NH #113) (ANTE $112) S-NH #113 PRESSURE MONITOR RPM1 & RPM2 INSTALLATION & WIRING DETAIL VENTURI VALVE & CONTROLLER (ANTE #112) TVTM Tx GENERATOR PROTECTED 12WAC r 18 AWG/2 CONDUCTOR/SHIELDED 16 AWG/2 CONDUCTOR SIGNAL WIRING 24 VAC POWER WIRING FET00kiNaf !- ROOM PRESSURE MONITOR ROOM PRESSURE MOU.TOR (ANTE #112) (WORK AREA #109) ANTE #112 PRESSURE MONITOR RPM1 & RPM2 INSTALLATION & WIRING DETAIL GENERAL NOTES NEW DUCTWORK SHALL BE INSTALLED USING THE FOLLOWING MATERIALS: —RIGID: GALVANIZED SHEET METAL, IN ACCORDANCE WITH ASHRAE AND SMACNA REQUIREMENTS FOR LOW PRESSURE DUCTWORK. (1" WC) —WRAP: 1.5" THICK, 3/4 LB. DENSITY FIBERGLASS INSULATION WITH VAPOR BARRIER JACKET. —FLEXIBLE: WIREMOLD TYPE WON OR EQUAL FLEXIBLE CLASS 1 AIR DUCT, THICK, 3/4 LB. DENSITY FIBERGLASS INSULATION AND FIRE RETARDANT REINFORCED METALIZED POLYESTER FILM LAMINATED ON SHEET WIRE REINFORCING, WITH 1.5" VAPOR BARRIER (HI —VINYL) AND SHALL MEET NFPA 90A AND UL STANDARD 181. 2. ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECT TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIED FOR FIRE STOPS ASTM—E814. 3. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 4. ALL DUCTWORK THROUGHOUT SPACE (SUPPLY & RETURN) IS TO BE INSULATED WITH WRAP MATERIAL DESCRIBED ABOVE. KEYNOTES 1. FURNISH AND INSTALL NEW T-STAT IN LOCATION SHOWN. LIGHTSTAT, MODEL #TME-POI. 2, NEW CONDENSING UNITS ARE OUTSIDE BUILDING ON GRADE NORTH IN PLAN PAST ADJACENT TENANT SPACE. NEW MECHANICAL EQUIPMENT LOCATED APPROXIMATELY IN SAME LOCATION AS 3' EXISTING EQUIPMENT. (UP ABOVE THE JOIST SPACE). ROUTE NEW 3/4" CONDENSATE DRAIN LINE FROM DRAIN PAN SIMILAR TO EXISTING LOCATION. RECONNECT/EXTEND EXISTING VENT, OUTDOOR AIR DUCTWORK, AND GAS CONNECTIONS OF APPROPRIATE SIZES TO NEW EQUIPMENT. 4. FURNISH AND INSTALL NEW 8"0 EXHAUST DUCT UP THROUGH ROOF TO ROOF MOUNTED EXHAUST FAN (EF-1) WITH BACKDRAFT DAMPER. ENSURE THAT EXTERIOR EXHAUST IS A MINIMUM 10'-0" AWAY FROM ANY AND ALL OUTDOOR AIR INTAKES. TO BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR INSIDE MODULAR SPACE. COORDINATE INSTALLATION WITH BIOLOGICS MODULAR. 5, FURNISH AND INSTALL NEW 10"0 EXHAUST DUCT UP THROUGH ROOF TO ROOF MOUNTED EXHAUST FAN (EF-2) WITH BACKDRAFT DAMPER AND BIRD SCREEN. ENSURE THAT EXTERIOR EXHAUST IS A MINIMUM 10'-0" AWAY FROM ANY AND ALL OUTDOOR AIR INTAKES. 6, FURNISH AND INSTALL NEW 4"0 EXHAUST DUCT UP THROUGH ROOF WITH ROOF CAP AND BIRD SCREEN. 7, CU-1 WILL REQUIRE AN ADAPTER FITTING TO BE FIELD INSTALLED BY CONTRACTOR FOR THE REQUIRED 1 1/8" LINE SET. 8, INDICATES THAT DUCTWORK (BOTH SUPPLY ® AND RETURN 1a ) TO DROP THROUGH ATTIC SPACE INTO SPACE ABOVE FINISHED CEILING AND CONTINUE AS SHOWN. 9, COORDINATE WITH WALL MANUFACTURER TO ENSURE LOW WALL RETURNS AS SHOWN. WALL MANUFACTURER TO PROVIDE CUTOUT/OPENING IN WALL SYSTEM FOR LOW WALL RETURNS. 10. COMPOUNDING AREA WORK BY OTHERS. INFORMATION FOR SYSTEMS/EQUIPMENT/MATERIAL SHOWN FOR INFORMATION ONLY. ALL WORK INDICATED IN THE AREA SHALL BE (UON) FURNISHED AND INSTALLED BY BIOLOGICS MODULAR. CONTACT JULIAN KARRAS, VP OF OPERATIONS, AT (317-456-9191) FOR PRICING/PROVISIONS OF THEIR EQUIPMENT. 11. ALL DUCTWORK WORK TO RUN IN ATTIC SPACE ABOVE COMPOUNDING AREA WITH THE EXCEPTION OF WHERE DIFFUSERS, LOW WALL RETURNS, AND EXHAUST DUCT ARE SHOWN. AT DIFFUSERS, LOW WALL RETURNS, AND EXHAUST DUCT DUCTWORK TO DROP STRAIGHT DOWN THROUGH ATTIC SPACE AND CEILING (WHEN NECESSARY) TO RESPECTED CONNECTION. 12. FOR CONTINUATION OF DUCTWORK IN COMPOUNDING AREA (SUPPLY AND RETURN) REFER TO ENLARGED PLAN ON SHEET M1.0. MODULAR COMPOUNDING MECHANICAL WORK (SUPPLY/RETURN) SCALE: 1/2" = 1'.0" 7S 31 Ia .1 D. ARCHITECTS PC a]84 TECHNOLOGY DRIVE FISHERS, IN 4W38 TEL 517568.2822 FAX S17,MIT S27 vrnmderchimcre.am Sr= NC=R �NGINEE2ING_ 1533 EAST NORTHFIELD DRIVE SUITE 400 DW W SPENCCERMEP CON �Iw a14 NC03982 STATE OF a� ate+ O J Q 0 f♦ V LLQ V f Y LL 0 J U_ Z a 2 tU w Z a J IL w 0 0 J LL DATE: 05/30/19