HomeMy WebLinkAbout190523 PURE Pharmacy Permit 19-P10RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City offCarmel
�Nq�\D.kMWA�
rLVVIC rLIAN - VVMOI Ill Vill I rIr INN
SCALE: 1/4" = 1'-0"
FLOOR PLAN - WATER PIPING WORK
SCALE: 1/4" = 1'-0"
GENERAL PLUMBING NOTES
1. ALL WORK SHALL CONFORM TO STATE AND LOCAL PLUMBING AND BACKFLOW PREVENTION CODES, AND THE
REQUIREMENTS OF THE LOCAL WATER UTILITY.
2. VACUUM BREAKERS MUST BE INSTALLED ON ALL EXISTING OR PROPOSED HOSE THREAD FITTINGS, INCLUDING BUT NOT
LIMITED TO HOSE REES, WALL/YARD HYDRANTS, MOP/SERVICE SINKS.
3. A CROSS -CONNECTION CONTROL DEVICE INSPECTOR SHALL TEST ALL BACKFLOW DEVICES AT THE TIME OF
INSTALLATION AND SUBMIT REPORTS TO THE LOCAL WATER UTILITY AS REQUIRED.
4. ALL WATER LINES 3" AND LARGER MUST BE DISINFECTED PER ANSI/AWWA C651-92. SAMPLES FROM 2 CONSECUTIVE
DAYS MUST BE TAKEN TO AN APPROVED TEST LAB. LAB ANALYSIS REPORTS SHALL BE SUBMITTED TO THE LOCAL
WATER UTILITY AS REQUIRED FOR COMPLIANCE.
5. COORDINATE EXACT LOCATION OF ROOF DRAINS WITH ARCHITECTURAL AND STRUCTURAL PLANS.
6. ALL MATERIALS INSTALLED WITH PLENUM SHALL HAVE FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE
DEVELOPED RATING NOT EXCEEDING 50 IN ACCORDANCE WITH STATE CODES.
7. THIS CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND LABOR FOR CORE DRILLING AS REQUIRED FOR
INSTALLATION OF PIPING PENETRATING BUILDING CONSTRUCTION.
S. TYPE 'K COPPER TUBING SHALL BE USED FOR ALL DOMESTIC SUPPLY PLUMBING BELOW SLAB. NO FITTINGS SUCH
AS COUPLINGS, TEES, OR ELBOWS SHALL BE USED BELOW OR WITHIN SLAB.
9, ALL EQUIPMENT USING NATURAL GAS SHALL HAVE A GAS COCK AND DIRT LEG FOR EACH PIECE OF EQUIPMENT.
10. REFERENCE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, TYPICAL.
11. PROVIDE 2" FIBERGLASS THICK INSULATION FOR ALL WATER AND SANITARY WASTE PIPING.
KEY NOTES
1,
FURNISH AND INSTALL NEW BACKFLOW PREVENTER AND CONNECT WATER SERVICE AS INDICATED.
2,
COLD WATER PIPE TO TURN UP THROUGH CEILING AND CONTINUE AS SHOWN.
3.
FURNISH AND INSTALL NEW TANKLESS GAS WATER HEATER IN CEILING. 4"0 VENT AND COMBUSTION
AIR
INTAKE PIPING TO RUN UP THROUGH ROOF.
4,
EXTEND AND CONNECT NEW 3/4" GAS PIPING TO NEAREST EXISTING GAS LINE. PLUMBING CONTRACTOR
SHALL FIELD VERIFY LOCATION OF EXISTING PIPING AND MAKE CONNECTION IN BEST LOCATION.
5.
EXTEND AND CONNECT NEW 3/4" COLD WATER PIPE TO EXISTING COLD WATER PIPE IN AREA OF
APPROPRIATE SIZE. PLUMBING CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING PIPE AND
MAKE
CONNECTION IN BEST LOCATION.
6,
PLUMBING CONTRACTOR TO FURNISH AND INSTALL NEW WALL MOUNTED SINK IN LOCATION SHOWN.
BIOLOGICS MODULAR TO PROVIDE BLOCKING. COORDINATE INSTALLATION WITH WALL MANUFACTURER.
7,
ASSUMED ROUTING OF EXISTING WATER SUPPLY ENTERING TENANT SPACE. PLUMBING CONTRACTOR
SHALL
FIELD VERIFY LOCATION AND DIRECTION OF FLOW PRIOR TO BID AND CONTACT ENGINEER FOR DISPOSITION
IF ASSUMPTION IS INCORRECT.
8.
FURNISH AND INSTALL NEW 4"0 VENT PIPING UP THROUGH ROOF AND TERMINATE WITH ROOF CAP
AND
BIRD SCREEN.
9. ASSUMED ROUTING OF EXISTING SANITARY PIPING ENTERING TENANT SPACE. PLUMBING CONTRACTOR SHALL
FIELD VERIFY LOCATION AND DIRECTION OF FLOW PRIOR TO BID AND CONTACT ENGINEER FOR DISPOSITION
IF ASSUMPTION IS INCORRECT.
10. CONNECT NEW SANITARY PIPE TO EXISTING SANITARY PIPING AS SHOWN.
11. FURNISH AND INSTALL NEW DRAIN PAIN WITH ASSOCIATED 3/4" CONDENSATE DRAIN WITH APPROVED AIR
GAP UNDERNEATH TANKLESS WATER HEATER IN CEILING. ROUTE CONDENSATE DRAIN TO FLOOR DRAIN IN
STORAGE #104.
12, WATER SUPPLY UNDERNEATH SLAB TO TURN UP AND CONNECT TO BACKFLOW PREVENTER.
NOTE: EXACT WATER SUPPLY, VENT PIPING AND SANITARY PIPING INSTALLATION IS UNKNOWN AND UNVERIFIED
PRIOR TO DESIGN. DESIGN INTENT IS TO CONNECT NEW FIXTURES TO EXISTING PIPING IN SPACE.
CONTRACTOR SHALL FIELD SURVEY TENANT SPACE OR DETERMINE LOCATION AND ROUTING BY OTHER
MEANS AND ENSURE DESIGN INTENT CAN BE MET. CONTACT ARCHITECT OR ENGINEER PRIOR TO BID IF
UNVERIFIED FOR DISPOSTION.
Ia
.11. ARCHITECTS, PC
as4 TECHNOLOGY DRIVE
FISHERS, IN 4603S
TEL 8I7SSS.2S22
FAX S17,MS.YS27
rml.mderchimcsiam
SP_ NC=R
�NGINEE2ING_
1533 EAST NQRIHFIELD DRIVE
SUITE 400
DW W SPENC IN CEP CON
Y
O
Z
m
J
a
Z
J
a
W
0
O
J
LL
NO.
NC03982
STATE OF
a
o
ao
0
O
rco
z
om
LLE
a
mED
a
w
DATE: 05/30/19