CONCENTRIC PIPE DETAIL
NOT TO SCALE
LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE
GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND
WHERE SHOWN ON PLANS. PROVIDE SACKFUL PER ARCHITECTURAL
SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR
AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS.
BRASS CLEANOUT PLUG
COUNTERSUNK HEAD
? 4.
C.I. WASTE LINE -
LENGTH TO SUIT
C.I. BEND
NOTES:
CEMENT FINISH
/ ,FINISH FLOOR
`%CONCRETE FILL
WATERPROOF MEMBRANE
2'-0" BEYOND DRAIN
4. a -SLAB
a
FLow�6
TRAP REQUIRED- BUT NOT SHOWN
AS PART OF INSTILLATION DETAIL
FLOOR DRAIN DETAIL
NOT TO SCALE
PROVIDE CLEANOUT TEE WITH
COUNTER -SUNK ASS PLASTIC
TAPERED -THREAD WITH TEE
JOINT COMPOUND.
FLOOR SLAB
1. FLOOR CLEANOUTS NOT TO BE LOCATED IN CARPETED AREA.
2. PROVIDE WALL CLEANOUTS (WCO1 WHERE SHOWN ON PLANS AND
ON SANITARY BRANCHES NO SERVED BY A FLOOR CLEANOUT:
SAN"ARV N LOCATED ABOVE FIXTURE FLOOD RIM WITHIN 4" OF FLOOR.
CONSULT LOCAL CODES FOR OTHER WOO REQUIREMENTS.
DIRECTIONTOFFLOA/8 BEND IF CLEANC_
OCCURS AT EN:; c I
FLOOR CLEANOUT WALL CLEANOUT DETAIL
SANITARY CLEANOUT DETAILS
NOT TO SCALE
FIXTURE UNIT
CALCULATION
PLUMBING
QUANTITY
SAN. F.U.
SAN. F.U.
WATER F.U. WATER F.U.
FIXTURES
EACH
TOTAL
EACH
TOTAL
WATER CLOSET
1
4.0
4.0
5C
5.0
LAVATORY
1
1.0
1.0
2C
2.0
FLOOR DRAIN
2
2.0
4.D
-
-
SINK
4
2.0
8.0
2.0
8.0
REFRIGERATOR
2
-
-
0.25
0.5
DISHWASHER
1
2.0
2.0
4.0
4.0
COFFEE
1
-
-
0,25
0.5
EWC
1
-
-
0.25
0.25
TOTAL
19.0
20.25
SERVICE SIZE
RED.
VENT
WASTE WATER
0
0 0
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City offlCannel
' V"CJNI
SHUT - OFF VALVF
F"',
10'-0" MIN.
CEARANCE FROM INTAKES
VENT PIPE THRU ROOF DETAIL
NOT TO SCALE
PRIMER VALVE
TRIBU➢ON UNIT(S1 AS REQUIRED
2 SERVING MU PLE TRAPS
TO OTHER FLOOR DRAINS
(WHERE APPLICABLE)
CEILING ORS
UNDER COUNTER
DRAIN
TRAP PRIMER DETAIL
NOT TO SCALE
SEWER
DECK
TOP BEAM ALL -THREAD ROD.
SEAL C-CLAMP LENGTH AS REQUIRED
F STEEL FOR PIPE SLOPE
BAR JOIST
PROVIDE COPPER
OR NON-METALLIC
ADJUSTABLE COATING WHERELNGER FOR
BAND HANGER HANGERS CONTACT FOUR INCH
FOR PIPING BARE COPPER PIPEFOUR INCH
OR LESS� �j i
BALL
SWING TYPE CHECK
HOT WATER SUPPLY
FROM SYSTEM
DO NOT HANG PIPE PROVIDE GALVANIZED STEEL SADDLE FOR ALL
LARGER THAN 3" FROM INSULATED PIPE LARGER THAN 3/4". VERIFY
BOTTOM OF JOISTS. INSULATION THICKNESS WHEN SIZING HANGERS.
PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE.
DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE
VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN
CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES.
HANGER SPACING FOR PIPE SIZE: COPPER: 4"=12' 3"=11' 2-1/2"=10'
2"=9' 1-1/2"=8' 1-1/4"=7' 1"=6' 3/4"=6'1/2"=5'. CAST IRON: 10'
AND ONE NEAR ALL JOINTS. STEEL' 4"=14' 3" =12' 2-1/2"=11' 2"=10'
1-1/2"=9' 1"=7' 3/4"=6' 1/2"=5'. LOCATE HANGERS AS CLOSE AS
POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL
STRUTS BETWEEN JOISTS IF REOUIRED.LOCATE HANGERS TO TAKE LOAD
OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING
DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS
REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON
OR STEEL IS NOT ACCEPTABLE. REFFE TO CODES FOR FURTHER
INFORMATION.
PIPE SUPPORT DETAILS
NOT TO SCALE
VALVE EQUAL TO ARMSTRONG CIRCUIT
HOT WATER RETUR
TO WATER HEATER
ALL BRONZE DANUAL BALANCING
SFTTFR
HOT WATER RETURN BALANCING STATION
NOT TO SCALE
NOTE: PROVIDE BALL VALVES ON BRANCH PIPING.
1
L,(
1 1 /2'V
SAN TF=
SANITARY DRAIN/WATER SUPPLY UNIT DETAIL
NOT TO SCALE
NOTE: PROVIDE BALL VALVES ON BRANCH PIPING.
1 i qua
WATER SUPPLY UNIT DETAIL
NOT TO SCALE
gOa
.11. ARCHITECTS, PC
a184 TECHNOLOGY DRIVE
HSHERS, IN 4W38
TEL 917558.2822
FAX S17,MS.La27
rm ivilarchimcre.am
SP_ NC=R
�NGINEEMNG_
1533 EAST NORTHFIELD DRIVE
SUITE 400
BWWW SPENCGERMEP CON
- UNION
i
:TEND AND CONNECT TO NEAREST
G LINE OF APPROPRIATE SIZE
ET 04u3932
'A SO ., STATE OF
1A/AT013 LICATCO E3I0IAIr r%08rA11
NOT TO SCALE
<q
€_
s
zQ
as
OLZ
o1�p
L3r
3
ogLL
ova
oli
�m
DATE: 05/30/19