STANDARD
MOUNTING HEIGHTS
CODE REQUIREMENTS
FINISHED CEILING
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OFTHE
SPECIFICATIONS & DRAWINGS AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES,
EXIT SIGN LOCATION. WALL OR
A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO
a
CEILING MOUNTED AS SCHEDULED.
THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE OF THE
OWNER, SUBJECT TO THE RECEIPT OF AN AFFADAVIT OR LETTER FROM THE GOVERNING
M.D. ARCHITECTS, PC
LIFE SAFETY DEVICES; CENTER
NOTE:
BODY AND OWNER'S PRIOR APPROVAL OF ANY ADDITIONAL COST TO BE INCURRED. ALL
9084 TECHNOLOGY DRIVE
ABOVE ELEC. DE VICES, SIGNS OR
p ALL COVER PLATES TO
DO
PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE
FISHERS, IN 4803&
FEC BELOW.
BE COLOR: WHITE.
SE CURED AND PAID FOR BY THE CONTRACTOR INVOLVED.
lEL:317558.2822
DOOR FRAME I WALL OPENING
FAX 317.553.2827
wM¢mdarchbobs cam
WHERE OCCURS
APPLICABLE CODES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING:
WALL MOUNTED SIGNAGE, WHERE
SCHEDULED.
EO EO
y r
o o
DOOR LATCH, PANIC DEVICE
w
Lit
n
no
THERMOSTAT, TELEPHONE, INTERCOM
BUILDING CODE 2014 INDIANA BUILDING CODE (COMPRISED FROM 2012 INTL. BUILDING CODE)
— —
SWITCHES, OCCUPANCY SENSOR,
MECHANICAL CODE: 2014 INDIANA MECHANICAL CODE (COMPRISED FROM 2012 INTL. MECHANICAL CODE)
a s
=
FIRE ALARM
a K
PLUMBING CODE: 2012 INDIANA PLUMBING CODE (COMPRISED FROM 20HINTL. PLUMBING CODE)
0
CARD READER, DOOR CONTROL
0 0 e =
DEVICES
z
ELECTRICAL CODE: 20D9INDIANA ELECTRICAL CODE (COMPRISED FROM NFPA 70 2005)
VOICEIDATNPOWER DEVICES
4
FIRE
CIRCUIT
SECURITY
I
ENERGY CODE: 2010 INDIANA ENERGY CONSERVATION CODE (COMPRISED FROM ASHRAE 90.12007)
EXTINGUISHER
BREAKER BOX
CONTROLS
LOCATE DEVICES AS DIMENSIONED.
WHERE NOT DIMENSIONED,
ACCESSIBILITY 2014 INDIANA BUILDING CODE (CHAPTER II ACCESSIBILITY) (COMPRISED FROM 678
LOCATE 6"FROM DOOR/WALL
6"U.O.N.
CODE: IAC 13-2612 CHAPTER II)
OPENING OR AT NEAREST WALL
ALL NEW OR ALTERED SWITCHES, CONTROLS, SECURITY KEYPADS,
FIRE CODE: 2014 INDIANA FIRE CODE (COMPRISED FROM 2012 INTL FIRE CODE)
STUD FROM LOCATION SHOWN ON
CREDITDEBITCARD SWIPES, ELECTRONIC LOCKSETS, PUBLICALLY
FLOOR PLAN.
ACCESSED T-STATS, COAT HOOKS, WALL PHONES, ETC WILL COMPLY
WITH THE REACH QUALIFICATION STANDARDS OF ICCIANSI Al 117,1
SECTIONS 308 AND 3D9.
BUILDING INFORMATION
OCCUPANCY: B- BUSINESS (PER SECTION 303)
N
CONSTRUCTION TYPE: TYPE B(NON SPRINKLEREO)(PER SECTION 6D23)
M
O
OCCUPANT LOAD: 1,589 s 1. 1100 sl PER OCCUPANT (PER CHAPTER 10, TABLE 1 DD41.2)
= 16OCCUPANTS
Z
]1] EXIT REOUIRED; [1] PROVIDED
—
_J
\ J
T ILLJ
MAY, TRAVEL
DISTANCE:=2DD-D"(1 D16.2,'B'OCCUPANCY- NON-SPRINKLERED)
MAX COMMON PATH PER IBC 1014.3THERE IS NO COMMON PATH OF TRAVEL RESTRICTIONS
U
OF EGRESS TRAVEL: BECAUSE ONLY ONE EXIT IS REQUIRED.
�/
\Ul
Q
`
Z
O
MAX. DEAD END PER IBC 1018.4 DEAD END CORRIDORS DO NOT APPLY BECAUSE
CORRIDOR:
ONLY ONE EXIT IS REQUIRED.
m
MIN.EGRESS16XO.2"(FACTORPERSEC710N1016.2-MN.44-)
CORRIDOR WIDTH:H:
W
Q
-3.7 USE 44"MIN.
MIN. DISTANCE PER IBC TABLE 1015.1, ONLYONE EXITISREQUIRED
O
BETWEEN EXITS:
(n
ILL
Z
PROJECT NOTES
/1
L.L
W
RENOVATION FOR CONVERSION OF EXISTING VACANT INTERIOR SPACE FOR PHARMACY
Z
0
W Q
o
W
D/�
PLUMBING COUNT NOTES (PER 2902.1)
L.L
B-BUSINESS OCCUPANCY OWNER -PROVIDED MAX: 13 OCCUPANTS 7 WOMEN, 7 MEN(1:1 RATIO)
_J
0
WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
L0
NOT REQUIRED PER NOT REQUIRED PER NOT REQUIRED PER IBC
N
IBC 2902.2, EXCEPTION 2 IBC 2912.2, EXCEPTION 2 TABLE 29021, EXCEPTION F
N
1 PROVIDED (UNISEX) 1 PROVIDED (UNISEX)
SERVICESNK
-
NOT REQUIRED PER IBC
�
TABLE 29D21, EXCEPTION G
----
- PER IBC 1014.3 THERE IS NO COMMON PATH OF
TRAVEL RESTRICTIONS BECAUSE ONLY ONE
.----" _
EXIT IS REQUIRED.
_----
- PER IBC 1005Z 13 IF A DOOR OPENS INTO A PATH
FIRE -RATED CONSTRUCTION REQUIREMENTS TYPE V-BCONSTRUCTION
OF EGRESS, HALF THE MINIMUM WIDTH MUST BE
xxnxlM
STRUCTURE OR ELEMENT HOURLY RATING U.L DESIGN NUMBER
MAINTAINED.
`�++{{a TARE:
INT.B EXT. NON -LOAD BEARING WALLS OHR. (PER 607.602) N/A
fad- 1`
No.1 bo •5 a
LL
UTI
dgxwxax100
DJACENT SUITE
3'-10"
N.I.C.1--�
I
6
WALL LEGEND
FEC
EXISTING WALLS TO REMAIN
— 1,
NEW WALL CONSTRUCTION, NO&INSULATED
NEW PARTIAL HEIGHT INSULATED WALL
—
CONSTRUCTION
WALLS BY BIOLOGICS
N
EXIT
CDC
o
W
EXISTING DOOR TO REMAIN
z
`.
h
0
z
1
p
y [ NEW DOOR TO BE INSTALLED
IIIIIIII J//I
'a
s
¢ A ■
� ` r
O �
z Oa
FEC = FIRE EXTINGUISHER CABINET
W
0
U
5a
B-BUSINESS
FE -SURFACE MOUNTED FIRE
EXTINGUISHER
RELEASED FOR CONSTRUCTION
17583 SF / 100
w m
w
a�o
� LO =
a
PATH OF EGRESS
omi=
E�w
Subject to
= ---
16 OCCUPANTS
compliance with all regulations
ow
CDP � �s>
d Stile and local Codes
w
¢w „3 3
City of caimel
, CODE PLAN