Loading...
HomeMy WebLinkAbout190523 PURE Pharmacy Permit 04-A11WALL PARTITION TYPES WALL LEGEND EXISTING WALLSTO REMAIN ARCHITECTURAL SYMBOL LEGEND64 PI FARF NETF IF ANY HA]ARDOI LA nPi IO IR STORED WITH NON -HAZARDOUS DRUG STERILE/ NON STERILE) THEN THE RELEASED FOR CONSTRUCTION ED AS HAZARDOUS DRUG. THE PASS THRU IS PROVIDED BETWEEN THE N-S AT US ROOM ONLY THE CONSIDERATION THAT THE OWNER WILL USING W FADE ROOM OR WORK ROOM AND NOT AS COMPOUNDING ROOM.. IN THE Subject to compliance with all regulations 9ED AS A COMPOUNDING ROOM THE PASSTHRU SHOULD NOT BE USED AND of State and local Codes iSMENT OF RISK PROCEDURES. City of Cannel (� �VT�T1\0*V.:TIDA�L \ DATE: 05/30/19 INEEN (N) GONG. Po-4,000PS1 — SAWCUT SLAB AS SHOWN (E)2'SAND --� ,l (E) COMPACTED FILL (E) VAPOR RETARDER (N)TAPEISEAL JOINTS PER BELOW - 1/2Yia. X 12 SMOOTH ROD IN DRILLED HOLES AT 19"G C. 43 @ 19" O.C. CENT. (N) 43 @ 19" O.C. IN) TAPEISEAL JOINTS PER BELOW BELOWIL VAPOR RETARDER PER BELOW PIPE PER PLUMBING I ELECTRICAL PLANS (E) CRUSHED ROCK 1. AFTER REMOVAL OF EXISTING MASONRY WALL, CHIP AWAY TOP OF EXISTING FOUNDATION WALL (OR BOTTOM OF EXISTING SLAB ON GRADE(&0,0), 2. DRILL HOLE INTO EXISTING S.O.G. TO ACCEPT NEW SMOOTH DOWEL PER"SMOOTH DOWEL" TABLE ABOVE. A. DRILL HOLE DIAMETER EQUAL TO DOWEL DIAMETER PLUS 1116. B. CLEAN HOLE OF DUST &DEBRIS. C. GREASE END OF SMOOTH DOWEL AND INSERT INTO HOLE IN EXISTING S.O. G. 3. WRAP DOWEL WITH SLEEVE OR PREATTACHED POLYETHYLENE GOVERN G TO ASSSURE SLIPPAGE IN PLACE IN THE NEW S.O.G. 4. PROPERLY CLEAN AND PREPARE EXISTING SUBSTRATE PRIOR TO CONCRETE PLACEMENT. 5. APPLY BOND BREAK PRIOR TO CONCRETE PLACEMENT. 6. POUR NEW SLAB ON GRADE. 7. IF EDGE OF EXISTING SLAB IS UNEVEN, SAW -CDT 1-1/2' DEEP AT 4" AWAY FROM EDGE OF EXISTING SO. G. AND BREAK OUT CONCRETE. EPDXY GROUT EVEN WITH TOP OF EXISTING S.O.G. & NEW S.O.G. (aka KEY -IN). SMOOTH DOWELS INFORMATION SLAB THICKNESS DOWEL SIZE LENGTH EMBED SPACING 4" & 5" 519" 19" 9 ill 6"&7' 3/4" 19, 9" 12' 9"&91 1" 19, 91 12' 10" 14 /4" 19, 9" 12' � FLOOR DETAIL - SLAB PATCH (TYPICAL) A1.1 1 12" = V-0" MODULAR CONSTRUCTION TREATED 2X WOOD BLOCKING BY CONTRACTOR AS REQUIRED ABOVE CEILING FOR SUPPORT OF NEW WALLS. EXIST. GYP WOOD TRUSS LINE OF 112' X 112' STEEL ANGLE, 1/16" THICK STRUCTURE 410-16 x 2" TEK 3 SCEWS, TYPICAL METAL MODULAR WALL STARTER TRACK LINE OF ARMSTRONG ACT CEILING SYSTEM CEILING MODULAR WALL PANEL METAL STUD HAT & COVER W/ 410-16 x 314" TEK 3 SCREWS z a > �. FOAM INSULATION _ 12" GYP BOARD, BOTH SIDES _ — PVC COATING, BOTH SIDES 410-16 x 2' TAPCON SCREWS METAL MODULAR FLOOR TRACK LINE OF STRUCTURE .� INTEGRAL COVE BASE BY CONTRACTOR / ,_ _ f- FLOORING BY CONTRACTOR ALL WORK SHOWN IN THIS DETAIL TO BE DONE BY BIOLOGICS MODULAR, UNLESS NOTED OTHERWISE MIN COMMENTS WRH SOUND NO SOUND STUD WALL FIRE UL TAC ATTENUATION ATTENUATION WIDTH WIDTH RATING LISTING RTING DESIGNATION DESIGNATION (w/Insul) B NON I MODULAR WALL N/A 3-1/9" 3" RATED NIA NIA SYSTEM MODULAR WALL 410-16 x ZTEK 3 SCREWS, TYPICAL METAL MODULAR WALL STARTER TRACK MODULAR WALL PANEL WO 519'GYP. BOARD BOTH SIDES BY CONTRACTOR WOODSTUDS URALPL PLAN OREINFOREFER TO ARCHITECTURAL PLAN FOR MORE INFORMATION. COORDINATE LOCATION WITH BIOLOGICS. 7 PLAN DETAIL- MODULAR WALL CONNECTION A7.1 3" =1'-0', UNEOF � STRUCTURE �,�'BRACE TO STRUCTURE ABOVE LINE OF T� z l 7 2X WOOD STUD TOP PLATE PROVIDE SOUND BATT INSULATION AS REQUIRED g 2XWOOD STUD FRAMING AT I6"O.C. 5/&" TYPE-X GYP. BOARD BOTH SIDES 2 X WOOD STUD BOTTOM PLATE LINE OF STRUCTUREURATED� SEALANTS BACKER ROD. CON7INI MN WITH SOUND NOSOUND STUD WALL FIRE UL STC ATTENUATION ATTENUATION WIDTH WIDTH RATING LISTING RATING DESIGNATION DESIGNATION A3i A3 NON 312' 4314" RATED N/A NA kI A6 NON 512, 63/4" RATED N/A N/A TYPICAL WALL (611 PAST CLG.) FA LINE OF CEILING 1 61/4 61/4"X1-1/7SOLID SURFACE CAP Still, REFER TO FINISH LEGEND FOR INFORMATION a 2X WOOD NAILER 5I6" GYP. BOARD BOTH � SLOES u LINE OF STRUCTURE 2X DBL PLATE WOOD NAILER LOW WALL w/ SS CAP f=J C MIN WITH SOUND NO SOUND STUD WALL HIRE UL STC COMMENTS ATTENUATION ATTENUATION WIDTH WIDTH RATING LISTING RATINGDESIGNATION DESIGNATION 03 NON N/A &1/2' 43/4" RATED N/A N/A � NON NIA 5112, 6314" RATED NIA NIA NEW WALL CONSTRUCTION, NON -INSULATED — NEW PARTIAL HEIGHT INSULATED WALL CONSTRUCTION — WALLS BY BIOLOGICS EXISTING DOOR TO REMAIN tC NEW DOOR TO BE INSTALLED O ARCHITECTURAL PLAN KEYNOTES 1. WALL MOUNTED SINK WITH EYEWASH ATTACHMENT. BIOLOGICS TO PROVIDE BLOCKING. CONTRACTOR INSTALLED. 2. EXISTING OPENING TO REMAIN. REMOVE EXISTING FRPME. PATCH AND FINISH EXPOSED FACES WITH GYP BOARD AND PAINT AS INDICATED IN FINISH PLAN. 3. UNDERCOUNTER FRIDGE PROVIDED AND INSTALLED BY OWNER. 4. DISHWASHER PROVIDED & INSTALLED BY CONTRACTOR. KENMORE OR EQUAL MAX. 2X2X210" (H). GC TO PROVIDE SUBMITTAL TO ARCHDECT FOR APPROVAL BEFORE PNV PURCHASE. 5. FULL SIZE FRIDGE PROVIDED AND INSTALLED BY OWNER. fi. CLEAN ROOM 18" x 18" PASS THRU BOX CONTRACTOR PROVIDED AND INSTALLED. MODEL NO CAP 18WF8. CONTACT CLEAN AIR PRODUCTS 1-800-4239T28. GC TO PROVIDE SUBMITTAL TO ARCHITECT FOR APPROVAL BEFORE ANY PURCHASE. BLOCKING ON WALL REQUIRED. ] COUNTER TOP COMPOUNDING HOOD BY OWNER, INSTALLED BY CONTRACTOR. & STERILE WORK AREA BY BIOLOGICS. 9 TALL CABINET PROVIDED AND INSTALLED BY OWNER. 10. BENCH PROVIDED AND INSTALLED BY OWNER. 11, OFFICE FURNITURE PROVIDED AND INSTALLED BY OWNER. 12 BREAK ROAM FURNDURE PROVIDED AND INSTALLED BY OWNER. 13. WALL MOUNTED TELEVISION. MOUNTED ON BULKHEAD WALL. PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. REFER INTERIOR ELEVATIONS FOR DETAILS 14. ALIGN 15. INFILL EXISTING DOOR OPENING. MATCH EXISTING ADJACENT WALL TYPE. REFER FINISH PLAN FOR INTERIOR FINISHES. 16 INFILL EXISTING DOOR OPENING. MATCH EXISTING ADJACENT WALL TYPE. REFER BIOLOGICS DRAWINGS FOR FINISHES. 17 MOBILE STORAGE CART PROVIDED AND INSTALLED BY OWNER. 1& FIRE EXTINGUISHER CABINET PROVIDED AND INSTALLED BY CONTRACTOR. 19 FLOOR MOUNTED COMPOUNDING HOOD PROVIDED BY OWNER, INSTALLED BY BIOLOGICS. 20, ALL CONNECTIONS BETWEEN MODULAR WALL AND CEILING TO BE SEALED AND CAULKED BY BIOLOGICS MODULAR. 21, NEW LOCATION OF ELECTRICAL PANEL REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION. ALL FLOORING WORK BY CONTRACTOR. D.C. T0. COORDINATE WITH THE OWNER &BIOLOGIC$ MODULAR FOR PROVISIONS OF THEIR EQUIPMENT. CONTACTJULIPN KARRAS, AT (31704569191) FOR WORK BY BIOLOGICS IN THE STERILE AREA (ROOMS 113,1128111) 101 DOOR TAG, REFER TO DOOR SCHEDULE. 1p1 DOOR TAG (IN RED, FOR AMODULAA DOOR), REFER TO DOOR SCHEDULE. WINDOW TAG, REFER TOA5.0 ELEVATION TARGET 11 WALLTVPE, REFER WALL PARTRION DETAILS DETAIL NUMBER IM 1 10 SHEET NUMBER ENLARGED PLAN OR DETAIL SECTION NUMBER 411 SIM SHEET NUMBER ELEVATION NUMBER SHEET NUMBER SEE SHEET A1.1 FOR ELEVATION SYMBOLS Q REVISION TAG WALL PARTITION NOTES A. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION, OR A COMBINATION OF BOTH DESIGNATIONS. B. WALL TAG DESIGNATION INDICATES WALL TYPE (SHOWN AS ACPPRAL LETTER), THICKNESS (SHOWN AS A NUMBER, REFER TO LEGEND BELOW), IF INSULATED (SHOWN WITH AN AND IF IT IS A RATED WALL (SHOWN WITH AN "f') NUMERIC CHARACTER STUD WIDTH 3 512' 6 612' 6 F114" REFER TO SPECIFICATIONS FOR MINIMUM STUD THICKNESS, MAXIMUM SPACING AND ALLOWABLE LIMITING HEIGHT DEFLECTION CRITERIA FOR GYPSUM BOARD ASSEMBLIES. C. IF NO SYMBOL DESIGNATION IS PROVIDED, THE WALL TYPE SHALL BE AN D. NOT ALL WALL TYPES LISTED WILL BE USED ON THIS PROJECT. REFER TO FLOOR PLANS AND NOTES FOR CORRECT WALL IDENTIFICATION & LOCAIIIXJ. E. "LINE OF STRUCTURE' INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE EXACT CONSTRUCTION CONDITIONS OR GEOMETRY. F. ALL DIMENSIONS ARE FROM FINISH FACE TO FINISH FACE OR FACE OF MASONRY. REFER TO PARTITION MATRICES FOR PPATRION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN. G. ALTHOUGH WALL STUD SIZES ARE LISTED FOR AREAS WHERE STUDS EXTEND TO STRUCTURE ABOVE OR HIGH AREAS, CONTRACTOR TO VERIFY SIZE INDICATED IS ADEQUATE FOR HEIGHT LISTED. PROVIDE ADEQUATELY SIZED STUD FRAMING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO FABRICATIONANSTALLATION. H. ALL INTERIOR NONBEARINGSTUDS TO BE DESIGNED FOR ADEFLECTION EQUAL TO BUT NOT GREATER THAN L/240, UNLESS FULL WALL FINISH IS DETERMINED TO BE FRAGILE OR BRITTLE, THEN DEFLECTION TO BE LI360 EXAMPLES OF FRAGILE FINISHES WOULD INCLUDE BUT NOT LIMITED TO ANY TYPE OF WALL TILE, PLASTER, OR PLASTER SKIM COAT. I. PROVIDE MOISTURE RESISTANT BOARD IN LIEU OF GYPSUM WALL BOARD IN ALL WET AREAS. INSTALL 519" CEMENT 80ARD (DUROCK OR EQUAL) AT ALL TILE WALL APPLICATIONS. J. REFER TO TOILET ACCESSORIES SHEET AND CASEWORK DETAILS FOR MOUNTING INFORMATION. K. REFER TO FINISH PLANS & SCHEDULES FOR FINAL WALL FINISHES. L. SEALANT: a NON -RATED PARTITIONS SHALL USE ACOUSTICAL SEALANT. M. ALL INTERIOR PARTITIONS SHALL HAVE ASTC RATING OF 46 UNLESS OTHERWISE INDICATED. PROVIDE ACOUSTIC GATT INSULATION AND SOUND SEALANT AT ALL INTERIOR GYPSUM HOARD PARTITIONS UNLESS NOTED OTHERWISE. N. WHERE GWBISNDEXTENDS TO DECK OR ON ONE SIDE ONLY WITH ACOUSTICAL INSULATION, PROVIDE VAPOR BARRIER TO HOLD INSULATION IN PLACE. 0, INSULATION: HEAD CONDITIONS AT FLOOR/ROOF DECK a NON -RATED PPATRIONSRC-0UIRING SOUND ATTENUATION SHALL USE SOUND ATTENUATION BLANKETS (SAB). P. FOR PPATRIONS INDICATED TO RECEIVE SOUND ATTENUATION BLANKETS (SPBI, EXTEND SAB TO FULL HEIGHT OF PARTITION UNLESS OTHERWISE INDICATED. FLOOR TRACK TO BE SET IN CONTINl10US BED OF SEALANT. ARCHITECTURAL GENERAL NOTES A G.C. SHALL COORDINATE WORK DESCRIBED IN ARCHITECTURAL SCOPE WITH THAT OF ALL OTHER TRADES. B. REVIEW DOCUMENTS, FIELD VERIFY EXACT SIZE AND LOCATIONS OF ALL EXISTING WORK PRIOR TO CONSTRUCTION. IN THE EVENT OF CONFLICTS OR OMISSIONS, CONTACT THE ARCHITECT. C. DO NOT SCOPE DRAWINGS. D. PROVIDE A PORTABLE FIRE EXTINGUISHER, WITH ABATING OF NOT LESS THAN 2-A, WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. PROVIDE SEMI -RECESSED TYPE CABINETS. E. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2' IN HEIGHT, INCLUDING AT DOOR THRESHOLDS. LEVEL CHANGES NOT EXCEEDING 1l4"MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2. F. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS. G. ALL DIMENSIONS ARE FROM FlNISH FACE TO FINISH FACE, OR FACE OF MASONRY H. ALL GYPSUM BOARD TO RECEIVE A'LEVEL 4'FINISH THRWGHOUT. I. CAULK JUNCTURES BETWEEN ALL DIFFERENT MATERIALS (LE. STOREFRONT AND GYPSUM BOARD). J. PROVIDE BLOCKING AT ALL WALL -MOUNTED TOILET ACCESSORIES, CABINETRY, EQUIPMENT ETC. TO ENSURE A STABLE INSTALLATION. K. PROVIDE MOISTURE RESISTANT BOARD IN LIEU OF GYPSUM WALL BOARD IN ALL WET AREAS. INSTALL 518" CEMENT BOARD (W BOCK OR EQUAL) AT ALL WALL TILE APPlCATONS. L. G.C. TO COORDINATE WITH OWNER FOR LEAD TIMES FOR OWNER PROVIDED APPLIANCES FIXTURES TO COMPLETE THE WORK IN TIMELY MANNER. a M.D. ARCHITECTS, PC 8064 TECHNOLOGY DRIVE FISHERS, IN /8038 lEL:317558.2822 FAX' 317.556.2027 wTnv.mdarchirecls cam u� ►u�1 ` J r w U � Q U M m w Q a W Q w a J In N v N i w J=]y J CO� � xo3 _Q