HomeMy WebLinkAboutA111 2nd FL Architectural Floor PlanARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
mr
WALL
WALL
PARTIAL HEIGHT WALL
®
PARTIAL HEIGHT WALL
®
�o
WINDOW/SIDELIGHT
n¢
WINDOW/SIDELIGHT
®
DOORANDFRAME
(SEE DOOR SCHEDULE(
77
DOOR AND FRAME
NOT: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE WI UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE R ISTANT/GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
F STANDARD WALL
3`/e" METAL STUDS AT 16" O.C.;
ONE LAYER OF 6% TYPE "XGYPSUM BOARD
EACH SIDE:
EXTEND WALL TO UNDERSIDE OF CEILING
RA WALL WITH INSULATION
36/ " METAL STUDS AT 16" O.C.:
ONE LAYER OF s% TYPE 'X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE
CEILING
I�DEMISING WALL TO DECK
WITH INSULATION
3Sy" METAL STUDS AT 16" O.C.;
ONE LAYER OF %" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL
H DEMISING WALL WITH SECURITY MESH
3s%" METAL STUDS AT 16" O.C.;
ONE LAYER OF 6/e TYPE 'X' GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" SOUND BATT INSULATION
EACH SIDE OF WALL ABOVE CEILING;
PROVIDE METALSECURIIY MESH ON TOP OF
WALL ABOVE CEILING TO DECK
R PARTIAL HEIGHT WALL
3`/e" METAL STUDS AT 16" O.C.;
ONE LAYER OF S% TYPE "X'GYPSUM BOARD EACH SIDE:
SEE ELEVATION FOR WALL HEIGHT;
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED;
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�LJ'�B*S41WML
DATE: 05/30/19
WALL
THICKNESS
METAL STUD
EXISTING WIN
MULLION
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
n WALL AT MULLION DETAIL
AI I I NOT TO SCALE
AREA NOT IN CONTRACT
AREA OF WORK
GENERAL NOTES
I. SEE ELECTRICAL PUN FOR INTENDED FURNITURE LAYOUT
2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 40R LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
PLAN NOTES
AOI ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR FRILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
A02 NEW SEMI RECESSED CABINET FOR FIRE EXTINGUISHER TO BE
PROVIDED AND INSTALLED BY CONTRACTOR, ENSURE EXISTING
FIRE EXTINGUISHER IS IN GOOD WORKING CONDITION AND
INSTALLED IN ACCORDANCE WITH NFPA 10.
PROVIDE (5) WHITE MELAMINE ADJUSTABLE SHELVES ON KV
A03 BRACKETS AND STANDARDS. PROVIDE BUCKING IN EXISTING
WALLS AS REQUIRED.
A04 ENSURES ERVER ROOM MEASURES 10-0"CLEAR IN NORTH -SOUTH
DIRECTION.
A08 CASED OPENING TO BE CENTERED ON WALL AS SHOWN.
OPROVIDE PLYWOOD PHONE BOARD, 4'XB'XJ", PAINTED WITH FIRE
A08 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH, VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
A07 PROVIDE FINISHED DRYWALL FINISH AT THIS SIDE OF WALL. NO
PAINT OR VINYL BASE REQUIRED,
PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
A08 TENANT'S WALL MOUNTED FURNITURE; COORDINATE EXACT
LOCATION WITH TENANT,
P01 PROVIDE POTABLE HOT AND COLDWATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
ppp PROVIDE WATER LINE FOR COFFEE, WATER COOLER, AND
REFRIGERATOR. CONFIRM LOCATION WITH TENANT.
ARCHITECTURAL PLAN
0 2' 4' 8' 16'
%�
MIS DRAWING, AND ME IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT ME WRITTEN
CONSENT OF SCH07 DESIGN.
CN4
70
CD
NNO
A/
L/
Q
ZNZ
J
SNEERER W SW
= L
LU
LU U
ZIII E_
aaaiiiiiw Q (Do
L z
ZZ0
Wad
Wiz
REVISIONS
MAR DATE DB DESCRIPTION
N0.
AR10700017
STATE OF
PROJECT NUMBER
2019.097
DRAWN BY
NP
2ND FLOOR
ARCHITECTURAL
FLOOR PLAN
NC A111