HomeMy WebLinkAboutA121 2nd FL Reflected Ceiling PlanLEGEND
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4',
FLUORESCENT, PARABOLIC FLUORESCENT, PARABOLIC
LIGHT FIXTURE, 2'x2', LIGHT FIXTURE, 2'x2',
FLUORESCENT. PARABOLIC FLUORESCENT. PARABOLIC
UNDERMOUNT LIGHTING:
---CONFIRM SPECIFICATION &
QUANTITY W/TENANT
8 EXITIIGHTFIXTURE ® EXIT LIGHT FIXTURE
EMERGENCY LIGHT ® EMERGENCY EIGHT FIXTURE
FIXTURE
LIGHT SWITCH w LIGHT SWITCH
$N3 LIGHT SWITCH,&WAY $3 LIGHT SWITCH,&WAY
$ND LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER
i — LIGHTCIRCUIT -- LIGHTCIRCUIT
CEIUNG GRID, -~ CEIUNG GRID,
SUSPENDED, 7X _ __ __' _ SUSPENDED, 7X2'
RELOCATED ® EXISTING DIFFUSER, LAY41N, 2'x2'
DIFFUSER, LAY IN, Tx2'
RELOCATED EXISTING DIFFUSER, LAY IN, 1'x4'
® DIFFUSER. LAY IN. 1'x4'
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS &
�MECHANT1ICAL DIFFUSER RELOCATION
RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�SJ'�D*S41WML_
DATE: \ 05/30/19
AREA NOT IN CONTRACT
AREA OF WORK
GENERAL NOTES
I. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING
GRIDIS2x2AT8'-8"A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIRANY
DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH
EXISTING.
2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED PER NEMA
AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN
EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50
PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS
WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE.
4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS NEW OR RELOCATED" ARE
=P79i 1101401AIM90712SAINrw]IA7RwZNAIPPCR78:P]TP[wPRlai
DEMOLITION PUN, THE DESIGN INTENT 15 LESS THAN 50%OF THE LIGHTS ARE
ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING
THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE
90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION, IF ADJUSTMENT 15 REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY
SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED
TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO
BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED
AREA 15 DETECTED, PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN
OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE
WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG
MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES
ARE SHOWN ADJACENT ON PLAN,
7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN
THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR
RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT
EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING.
ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST
COMPLY WITH ALL APPLICABLE CODES,
B. PROVIDE SEPARATE PRICE FOR 2'X4'LED LAY -IN FIXTURES THROUGHOUT;
CONFIRM SPECIFICATION WITH PROPERTY MANAGEMENT. IF SEPARATE PRICE IS
ACCEPTED, LAYOUT IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF
ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY
SDI.
MECHANICAL NOTES
MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE AND B
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT 15 BEING ADDED; MECHANICAL CONTRA(TORIS iO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
PLAN NOTES
8
CONTROL ENTRY 201, OPEN OFFICE 209& 213 LIGHTING WITH
3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES
AS REQUIRED.
OR02PROVIDE SWITCH AT THIS LOCATION FOR UNDER COUNTER
LIGHTING.
PROVIDE ETHER INDIVIDUAL AC UNIT OR AT MINIMUM A
M01 THERMOSTATICALLY CONTROLLED EXHAUST AT THE LOCATION.
COORDINATE ALL DETAILS WITH TENANT.
REFLECTED CEILING PLAN
0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTF
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
M
O
NNO
N z
Z i
LU W
H
LU
WYU
Z
RRRRR� QS �
L Q
ZZ0
Waw
Wiz
Ln
to
ISSUE
DATE DESCRIPTION
03/25/19 REVIEW SET
04/10/19 PERMITSET
REVISIONS
MARK DATE I DB DESCRIPTION
N0.
AR10700017
STATE OF
PROJECT NUMBER
2019.097
DRAWN BY
NP
2ND FLOOR
REFLECTED
CEILING PLAN
IN Al21