Loading...
HomeMy WebLinkAboutA121 2nd FL Reflected Ceiling PlanLEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x2', LIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC FLUORESCENT. PARABOLIC UNDERMOUNT LIGHTING: ---CONFIRM SPECIFICATION & QUANTITY W/TENANT 8 EXITIIGHTFIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT ® EMERGENCY EIGHT FIXTURE FIXTURE LIGHT SWITCH w LIGHT SWITCH $N3 LIGHT SWITCH,&WAY $3 LIGHT SWITCH,&WAY $ND LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER i — LIGHTCIRCUIT -- LIGHTCIRCUIT CEIUNG GRID, -~ CEIUNG GRID, SUSPENDED, 7X _ __ __' _ SUSPENDED, 7X2' RELOCATED ® EXISTING DIFFUSER, LAY41N, 2'x2' DIFFUSER, LAY IN, Tx2' RELOCATED EXISTING DIFFUSER, LAY IN, 1'x4' ® DIFFUSER. LAY IN. 1'x4' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & �MECHANT1ICAL DIFFUSER RELOCATION RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�SJ'�D*S41WML_ DATE: \ 05/30/19 AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES I. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRIDIS2x2AT8'-8"A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIRANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE. 4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS NEW OR RELOCATED" ARE =P79i 1101401AIM90712SAINrw]IA7RwZNAIPPCR78:P]TP[wPRlai DEMOLITION PUN, THE DESIGN INTENT 15 LESS THAN 50%OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION, IF ADJUSTMENT 15 REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA 15 DETECTED, PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN, 7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES, B. PROVIDE SEPARATE PRICE FOR 2'X4'LED LAY -IN FIXTURES THROUGHOUT; CONFIRM SPECIFICATION WITH PROPERTY MANAGEMENT. IF SEPARATE PRICE IS ACCEPTED, LAYOUT IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. MECHANICAL NOTES MECHANICAL WORK IS LIMITED TO A DESIGNBUILDSCOPE AND B OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT 15 BEING ADDED; MECHANICAL CONTRA(TORIS iO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, PLAN NOTES 8 CONTROL ENTRY 201, OPEN OFFICE 209& 213 LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. OR02PROVIDE SWITCH AT THIS LOCATION FOR UNDER COUNTER LIGHTING. PROVIDE ETHER INDIVIDUAL AC UNIT OR AT MINIMUM A M01 THERMOSTATICALLY CONTROLLED EXHAUST AT THE LOCATION. COORDINATE ALL DETAILS WITH TENANT. REFLECTED CEILING PLAN 0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTF DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. N M O NNO N z Z i LU W H LU WYU Z RRRRR� QS � L Q ZZ0 Waw Wiz Ln to ISSUE DATE DESCRIPTION 03/25/19 REVIEW SET 04/10/19 PERMITSET REVISIONS MARK DATE I DB DESCRIPTION N0. AR10700017 STATE OF PROJECT NUMBER 2019.097 DRAWN BY NP 2ND FLOOR REFLECTED CEILING PLAN IN Al21