HomeMy WebLinkAboutE111 2nd FL. Electric PlanPOWER CUILEI, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX BOX, BLANK COVER PLA PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION, POWER POLE BY OTHERS. POWER CHILLI, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX BOX, BLANK COVER PLATE FLOOR BOX WITH POWER FLOOR BOX WITH POWER FI® AND DATA, FLUSH &b AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH ® JU NCTION BOX AND J b JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION b OUTLET (PROVIDE BOX b PULL STRING ONLY OUTLET DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City d Camel �VT�SJ'�D*S41WML_ DATE: \ 05/30/19 ® AREA NOT INC( ❑ AREA OF WORK GENERAL NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED I B'MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. PLAN NOTES OE01 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANTS SECURITY CONTRACTOR, SEE DOOR SCHEDULE FOR MORE DETAILS. E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. E03 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. E05 COORDINATE EXACTSERVER ROOM REQUIREMENTS WITH TENANT. E06 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 66' A.F.F. THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC.. AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. CV L') CD ZNZ N J W WCC L LU WYU Z�� v�Q Zz0 Waw W3Z n LO ISSUE DATE DESCRIPTION 03/25/19 REVIEW SET 04/10/19 PERMITSET REVISIONS MAR DATE DB OESCRIP110N N0. AR10700017 STATE OF PROJECT NUMBER 2019.097 DRAWN BY NP 2ND FLOOR ELECTRICAL PLAN ELECTRICALPLAN 0 2'4'4' 8'8' 16' N