HomeMy WebLinkAboutE111 2nd FL. Electric PlanPOWER CUILEI, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
BOX, BLANK COVER PLA
PROVIDE JUNCTION BOX
ABOVE CEILING FOR
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
POWER CHILLI, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
BOX, BLANK COVER PLATE
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
FI®
AND DATA, FLUSH
&b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JU NCTION BOX AND
J b
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
b
OUTLET (PROVIDE BOX
b
PULL STRING ONLY
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42'
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City d Camel
�VT�SJ'�D*S41WML_
DATE: \ 05/30/19
® AREA NOT INC(
❑ AREA OF WORK
GENERAL NOTES
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED I B'MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
PLAN NOTES
OE01 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANTS SECURITY CONTRACTOR, SEE DOOR SCHEDULE
FOR MORE DETAILS.
E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
E03 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
E05 COORDINATE EXACTSERVER ROOM REQUIREMENTS WITH TENANT.
E06 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO
CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 66'
A.F.F.
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC.. AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
CV
L')
CD
ZNZ
N J
W WCC
L
LU
WYU
Z��
v�Q
Zz0
Waw
W3Z
n
LO
ISSUE
DATE DESCRIPTION
03/25/19 REVIEW SET
04/10/19 PERMITSET
REVISIONS
MAR DATE DB OESCRIP110N
N0.
AR10700017
STATE OF
PROJECT NUMBER
2019.097
DRAWN BY
NP
2ND FLOOR
ELECTRICAL PLAN
ELECTRICALPLAN
0 2'4'4' 8'8' 16' N