HomeMy WebLinkAboutL100 - 2nd Fl Life Safety2 3 4 5 6 7 B 9 10 11 12 13 14 15 16 CODE SUMMARY wiw SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS) OCCUPANCY CLASSIFICATION BUSINESS) CHANGE OF OCCUPANCY CIASS2 NO TOTAL BUILDING AREA 19.568 SF/FLOOR X 1 590RIES = 97.840 SF TOTAL PROJECTAREA OCCUPANCY CALCULATIONS NUMBER OF EXITS 5,332 SF SPACE TYPE AREA SF PER OCC UPANT OCCUPLOAD GEN. OFFICE 5,332 SF 100 54 TOTAL OCCUPANTS IN PROJECTAREA 54 REQUIRED:2 PROVIDED:2 Iiiiiiiim SPRINKLER SYSTEM) YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 19,568 SF ACCESSORYAREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILTBEFORE 1978? NO BUILDING CONSTRUCTION TYPE il-B LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT. BUILDING STAIR LOCATION TFe FIRE EXTINGUISHER ® EXITSIGN I& EMERGENCY LIGHT — — — TRAVEL DISTANCE AREA NOT IN CONTRACT AREA OF WORK RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 05/30/19 LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES, 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. S. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. I2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16, THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DEIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. CV M O r n �O V Z oZ ZN W LU H LU LU U z F- �z ` Z Wad W 7 � n SSUE DATE DESCRIPTION 03/25/19 REVIEW SET 04/10/19 PERMITSET REVISIONS MAR DATE DB DESCRIPTION N0. AR10700017 STATE OF PROJECT NUMBER 2019.097 DRAWN BY NP 2ND FLOOR LIFE SAFETY IN <D L100