CODE SUMMARY
wiw
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS)
OCCUPANCY CLASSIFICATION
BUSINESS)
CHANGE OF OCCUPANCY CIASS2
NO
TOTAL BUILDING AREA
19.568 SF/FLOOR
X
1 590RIES
=
97.840 SF
TOTAL PROJECTAREA
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
5,332 SF
SPACE TYPE AREA SF PER OCC UPANT OCCUPLOAD
GEN. OFFICE
5,332 SF
100
54
TOTAL OCCUPANTS IN PROJECTAREA 54
REQUIRED:2 PROVIDED:2 Iiiiiiiim
SPRINKLER SYSTEM) YES/NO)
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
19,568 SF
ACCESSORYAREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
EXEMPT (SEE REFLECTED CEILING PLAN)
BUILTBEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
il-B
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT. BUILDING STAIR LOCATION
TFe FIRE EXTINGUISHER
® EXITSIGN
I& EMERGENCY LIGHT
— — — TRAVEL DISTANCE
AREA NOT IN CONTRACT
AREA OF WORK
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 05/30/19
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES,
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
S. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
I2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXITSIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
LIFE SAFETY PLAN
0 4' 8' 16,
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DEIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
CV
M
O
r n �O
V Z
oZ
ZN
W LU
H
LU
LU U
z F-
�z ` Z
Wad
W 7
�
n
SSUE
DATE DESCRIPTION
03/25/19 REVIEW SET
04/10/19 PERMITSET
REVISIONS
MAR DATE DB DESCRIPTION
N0.
AR10700017
STATE OF
PROJECT NUMBER
2019.097
DRAWN BY
NP
2ND FLOOR
LIFE SAFETY
IN <D L100