E-2 Power Plan-SS-082318
NOTES: OI OUTLETS ARE EXISTING TO REMAIN - RELOCATE TO LOCATION AS SHOWN. OTHER EXISTING OUTLETS NOT SPECIFICALLY SHOWN (EC. TO VERIFY) CAN REMAIN IN PLACE. REUSE EXISTING CIRCUITS IN EXISTING ELECTRICAL PANELS. O2 REMOVE EXISTING DATA / NETWORK J-BOXES 4 WIRING. REPLACE w/NEW AT LOCATIONS 4 QUANTITIES SHOWN. O3 OUTLETS FOR TELLER PODS / RECEPTION POD TO REUSE EXISTING CIRCUITS IN EXISTING PANELS DEDICATED TO PREVIOUS OCCUPANTS TELLER LINE STATIONS. ® EXISTING J-BOX FOR BUILDING SIGNAGE TO REMAIN, REUSE EXISTING SIGNAGE CIRCUITS IN EXISTING PANEL FOR NEW BUILDING SIGNAGE. O5 4" UNDERGROUND CONDUIT TO J-BOX AT EACH POD, STUB UP FROM EXISTING MECHANICAL / ELECTRICAL ROOM (LEAVE Vi SPACE AT EACH POD) (TYPJ. O EXISTING MAIN DISTRIBUTION PANEL / 400A wAUIREWAY 4 MAIN DISCONNECT AND 200A PANEL BREAKER TO REMAIN. EXISTING 200A ELECTRICAL PANEL (FED FROM EXISTING WIREWAY) TO REMAIN. 8 EXISTING LIGHTING CONTRACTOR PANEL (EXISTING SITE LIGHTING, EXTERIOR LIGHTS, 4 SIGNAGE) TO REMAIN. O NEW OUTLET ON EXISTING CIRCUIT. 10 3P, 30AMP, 600 VAC DISCONNECT SWITCH FOR CONNECTION TO CONDENSER UNIT (MATCH EXISTING). FUSE PER UNIT NAME PLATE. II 3P, 20AMP, 600 VAC DISCONNECT SWITCH FOR CONNECTION TO AIR HANDLER UNIT (MATCH EXISTING). FUSE PER UNIT NAME PLATE. 12 G.C. TO COORDINATE 34"x4'x4' PLYWOOD PHONE BACKBOARD w/GROUND AT STANDING HEIGHT AT SERVICE ENTRANCE (VERIFY EXISTING BACKBOARD. REPLACE AND / OR RELOCATE AS NEEDED). 13 NEW INTERNALLY ILLUMINATED / LED TRAFFIC CONTROL SIGNS ABOVE DRIVE-THRU LANES (2) - REUSE EXISTING DRIVE-THRJ SIGNAGE CIRCUITS IN EXISTING PANELS. 14 AREA SMOKE DETECTOR WIRED INTO DETECTION / ALARM SYSTEM. 15 FIRE COMMAND CENTER 16 FIRE COMMAND PANEL BATTERY / POWER SYSTEM. IT NEW THROUGH -WALL ITM IN EXISTING OPENING. REUSE EXISTING ITM CIRCUIT IN EXISTING PANEL. IS 4" UNDERGROUND CONDUIT FROM NETWORK CONTROL CABINET TO TELLER PODS. STUB UP 'INSIDE' POD. 1ST I" POWER CONDUIT 4 2" DATA CONDUIT UNDERGROUND TO EXISTING MECHANICAL / ELECTRICAL ROOM -REUSE EXISTING DRIVE-THRJ ATM CIRCUIT IN EXISTING PANEL. ©0 ACCESS CARD READER 4 WIRING - RUN WIRING THROUGH JAMB TO LATCH PLATE CONTACT (EC. TO COORDINATE W/IMCU I.T.). MOUNT READER ADJACENT TO DOOR TOP OF READER AT +4'-0" AFF. (READER FOR REAR DOOR TO BE MOUNTED ON BUILDING EXTERIOR AND RATED FOR EXTERIOR USE). 21 4" CONDUIT FROM SECURE ENTRY SCANNING: UNIT - STUB UP AT RECEPTION POD FOR CONNECTION TO MASTER OVERRIDE SWITCH, ALSO RUN TO STUB AT TELLER POD FOR CONNECTION TO SLAVED OVERRIDE SWITCH. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 06/05/19 i EXIT EXISTING MAIN DISTRIBUTION PANEL wAIAIN DISCONNECT SWITCH EXISTING 400A / 120/206V 3P, 4W METERBASi_ EXISTING TRANSFORMER PROVIDE SERVICE EXISTING INCOMING SERVICE CONDUCTORS-4 VC 5CA-E ----- I CONFERENCE ROOM I 12 F I I 3 �II LINE OF TOWER ROOF EXISTING 200A RATED PANEL TO REMAIN EXISTING LIGHT CONTROL PANEL TO REMAIN EXISTING 200A PANEL BREAKER EXISTING IN DISCONN T SWITC EXISTINGE IAREWAY H OUT TO EXISTING EQUIPMENT OUTLETS, ETC. — EXISTING SERVICE GROUNDS TO REMAIN RVICE RISER DIAGRAi"li1 NOTES: I. ALL RECEPTACLES ABOVE COUNTER ARE TO BE RELOCATED TO +48 AFF. TO CENTER OF BOX. 2. ALL WIRING MUST BE IN CONDUIT. ALL WIRING ABOVE CEILING MUST BE INSTALLED PER CODE REQUIREMENTS FOR PLENUM CONDITIONS. 3. ITM / ATM UNITS TO BE INSTALLED PER MANUFACTURER REQUIREMENTS. 4. COFFEE COUNTER OUTLET AT +I8" AFF. (INSIDE COUNTER) w/GROMMET / OPENING IN COUNTERTOP FOR PLUGS / WIRE5. 5. EXISTING OUTLETS TO REMAIN. COMBINE EXISTING WIRING FOR DUPLEX CUTLETS TO CREATE NEW QUAD OUTLETS IF NEEDED. REUSE EXISTING CIRCUITS IN EXISTING PANELS. 6. EACH AREA SMOKE DETECTOR TO BE LABELED BY ENTRY SYSTEM INSTALLATION TECHNICIANS w/ELECTRONIC ADDRESS ID FROM FIRE ALARM PANEL (FIRE DEPARTMENT WILL BE ABLE TO TRACK 4 ID A SPECIFIC ZONE). LEGEND 10 DUPLEX OUTLET (EXISTING RELOCATED) 10 QUADPLEX OUTLET (EXISTING RELOCATED) © COMPUTER / NETWORK CONNECTION - 44 BOX dill COVER ® CEILING MOUNTED COMPUTER / NETWORK CONNECTION QU JUNCTION BOX I@a GROUND FAULT INTERRUPTING OUTLET ® AREA SMOKE DETECTOR ALARM WIRE CONNECTION (EC. TO PULL ALARM WIRE TO ® LOCATION SHOWN FOR CONNECTION TO MONITORING DEVICE - COORDINATE w/IMCU I.T.) CEILING MOUNTED ALARM WIRE CONNECTION OM MASTER OVERRIDE SWITCH FOR SECURE ENTRY SHUTDOWN Os SLAVED OVERRIDE SWITCH (TO MASTER) FOR SECUIRE ENTRY SHUTDOWN NEW DRIVE-THRU SIGNAGE CONTROL BOX - EC. TO COORDINATE w/IMCU I.T. $u.+wN Av,oc�.Ezcs, I,.c. A.,ii'i E 5142 Madison Avenue, Suite 4 Indianapolis, IN 46227 (317) 783-2343 No. STATE OF ROBERT E. BEAMAN N AR00033778 PROJECT Ill 1801 A DRAWN BY: bai CHK. BY: DATE: AUGUST 21, 2018 REVISIONS: 1801 A / alc / NOV. 8, 2018 LINE OF LOWER v AHU-3 ROOF © OFFICE 02 OFFICE #I RR •I RR �2 8 l 6 3 1 2 1 2 a o 0 l j 1'OR'FR PLAN L------------- ---- �J P WER PLAN I QQ __ --_ ©1 r— ---- 0 2 4 5 R-2 — — --- ----- — .-ram IO 10 E 2 rl C l-3 GU-2 CU-I