Loading...
HomeMy WebLinkAbout19060022 State ReleaseELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.aov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project Information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are riot compatible to view this report Project number Release date ""�De� CONSTRUCTION DESIGN RELEASE 408213 05/31/19 a�""'RState Form 41191 (R9/5.98) �w Construction type Occupancy classification -Report Printed on: May 31, 2019 II-B, SPK B, REM h" 1Scope of release Indiana Department of Homeland Security INDIANA 02 ARCH ELEC MECH DIVISION OF FIRE & BUILDING SAFETY F PLUM PLAN REVIEW DIVISION ;ti . ) Type of release 402 W. Washington St., Room E245 A CCC.,, Standard Indianapolis, IN 46204 N00sIER SAFE7Y_ Avallable At Your Local Licence Branch Project name To: Owner/Architect I Engineer SUPPORT HOOSIER SAFETY Keating Douglas Law Schott Design Kevin Hugh Boyle AR10700017 street address 450 East 96th St. 550 Congressional Blvd Suite 175 suite 125 Indianapolis IN 46240 City County lax & e-mail: 3176609170,studlob@schottdosign.com CARMEL HAMILTON 'jte plans, -specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of is Fire Prevention and Building Safety Commission The project is released for construction subject to, but not necessarily limited ifo, the conditions sted below. THIS IS NOT A BUILDING PERMIT �II required local pennils and ticenses�must be obtained prior to beginning construction work. All onstruction work must be in full compliance +/wth all applicebje Mate rnlles: Any pmange's in the released plans and/or specificationstmust be filed with ind released by this Office before any wor Is altered This please may ba suspWed or revoked if it is determined to be issued inlerror, in violation -f any rules of the Commission or if It Is based on`Incorrect or insufficient information! Thts�release shall expire by Ilmltatlon,::and be ome null and aid, if the work authorized Is not commenced within one (1) year from the above dale. ,ONDITIONS: late :(A1A & Al B) In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans nd specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Jommission. Providing false informatiop constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fie up to $10,000. i accordance with Section 19 of the General Administrative Ryles (675 IAC 12-6-19) a complete set of plans and specifications the conform exactly to the design that was released by the office of the slate building commissioner shall. be maintained on the construction jobs to as well as a opy of the design release. ' 14B Thisrpr _ject has been revIlevied under the 2014 Indiana Building Code. 4GO4124E The proposed building, addition, or remodel shall not put the existing building in noncon ipliance or into further noncompliance in accordance with 675 IAC 12-4-12. 4G0603AF ' Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in'accordance with 675 IAC 12 6 3(a), 675' IAC 12-6- 7(g)(17), and 675 IAC 13 1 8. (N F P.A. 13) 14W1104A Required means of egress shall be maintatried during construction and demoittion, remodeling or alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5). 9E11027B Where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be installed to prevent damage in accordance with Section 110.27(B), IEC (675 IAC 17-1.8). 14B1100HC The current code for handicapped accessibility in use in the State of Indiana is Chapter 11 of the Indiana Building Code (675 IAC 13-2.6) and ICC standard A117.1, 2009 edition (675 IAC 13-2.6). AREL Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Page 1/2 ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http:llwww.in.gov/dhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans Use Internet Browser to View this report, other browsers are not compatible to view this report Please be advised that If an administrative review of this action is desired, a written petition for review must be filed at the above address with the Fire Prevention and Building Safely Commission identifying the matter for which a review Is sought no later than eighteen (18) days from the above - stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you choose to petition, and the before -mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will be final, and you must comply with Its requirements. mianderson@dhs.in.gov Address (name,title of local officlal,street,clty,state and ZIP code DEPT OF COMMUNITY SERVICE JIM BLANCHARD ONE CIVIC SQUARE CARMEL, IN 46032 t J� I s Director, Division of Fire and Building Safety Page 212